<br />DIVISION: 07 00 00-THERMAL AND MOISTURE
<br />construction types over approved sheathings capable of
<br />PROTECTION
<br />supporting the imposed loads, including but not limited to
<br />Section: 07 46 33-Plastic Siding
<br />positive and negative transverse wind load; and as
<br />closures on the underside of exterior roof eaves (soffits).
<br />REPORT HOLDER:
<br />3,0 DESCRIPTION
<br />CERTAINTEED CORPORATION
<br />The vinyl sidings and soffits are extruded from polyvinyl
<br />803 BELDEN ROAD
<br />chloride (PVC) resins. The siding panels conform to the
<br />JACKSON, MICHIGAN 49203
<br />requirements of ASTM D 3679 and are formed with an
<br />(800) 233-8990
<br />upper edge having nail slots and a lower edge that hooks
<br />A Lcertainteed.com
<br />into the upper edge of the lower course. The accessory
<br />items, used to detail the application of the product as an
<br />EVALUATION SUBJECT:
<br />exterior wall covering, are of the same material.
<br />CERTAINTEED VINYL SIDING AND SOFFIT
<br />All panels are designed with receiving legs and a nailing
<br />tl8-inch-by-%-inch
<br />flange with a 1 (28.58 trim by 9.53 mm)
<br />ADDITIONAL LiSTEES:
<br />prepurtched elongated nailing slot spaced 2 inches
<br />(50.80 mm) on center. All siding panels used in horizontal
<br />VINYL CARPENTRY
<br />applications have weep holes prepunched at a minimum of
<br />750 EAST SWEDESFORD ROAD
<br />18 inches (457.2 mm) on center on the underside to
<br />VALLEY FORGE, PENNSYLVANIA 19482
<br />provide ventilation and drainage.
<br />(800) 233-8990
<br />The panels are available in different colors with smooth
<br />finish or embossed with a matt or wood -grain texture. The
<br />VYTEC
<br />panels range in thickness from 0.036 inch to 0.50 inch
<br />750 EAST SWEDESFORD ROAD
<br />(0.91 mm to 1.27 mm).
<br />VALLEY FORGE, PENNSYLVANIA 19482
<br />The accessory shapes include a fascia, "F" shaped trim,
<br />(800) 233-6990
<br />"J" shaped trim, drip cap, starter strips, inside/outside
<br />comers, quarter round soffit molding, undersills, soffit cove
<br />WOLVERINE SIDING SYSTEMS
<br />trim, and "H" divider bar. The thicknesses of accessories
<br />750 EAST SWEDESFORD ROAD
<br />range from 0.040 to 0.050 inch (1.02 to 1.27 mm).
<br />VALLEY FORGE, PENNSYLVANIA 19482
<br />Refer to Table 1 for panel thicknesses, lengths and
<br />(800) 233-8990
<br />profiles within the scope of this report.
<br />1.0 EVALUATION SCOPE
<br />4,0 INSTALLATION
<br />Compliance with the following codes:
<br />4.1 General:
<br />®
<br />■ 2009 International Building Code (IBC)
<br />Installation of the system, including the panels, corners,
<br />starter strips, trim and other accessory items, must be
<br />■ 2009 International Residential Code (IRC)
<br />installed in accordance with IBC Section 1405.14 or IRC
<br />■ Other Codes (see Section 8.0}
<br />Section R703.4, as applicable, ASTM D 4756, the
<br />manufacturers published installation instructions, the
<br />Properties evaluated:
<br />and this report.
<br />■ Exterior veneer
<br />4.2 Siding Installation:
<br />■ Wind load resistance -transverse
<br />u s ailed over solid plywood structural
<br />sheathing complying with DOC PS 1, or Exposure 1
<br />■ Types I, II, III and IV (noncombustible) construction
<br />oriented strand board (OSB) sheathing complying with
<br />■ Fire -resistance -rated construction
<br />DOC PS 2, covered with an approved water -resistive
<br />barrier as required by the applicable code.
<br />2.0 USES
<br />The method of application of the siding is by first
<br />CertainTeed vinyl sidings, which are also sold under the
<br />installing a starter strip horizontally, along the bottom of the
<br />brand names Wolverine, Vytec and Vinyl Carpentry, are
<br />building matching the lowest corner of the building. The
<br />used as exterior wall coverings on buildings of all
<br />starter strip is then nailed to the building every 8 inches
<br />]CC -ES Evaluation Reports are not to be construed as representing aesthetics or onv other auributes not specifically addressed, nor are thev to be construed '
<br />as an endorsement of the subject of the report or a recommendation for its use. There is no aarrontr by ICC Evahration Service, LLC,
<br />to atn7 f nding or other matter in this report, or as to ant product covered bt the report.
<br />erpr"' s or implied, as
<br />Copyright © 2010
<br />Page 1 of 6
<br />ESR-1066 i Most Widely Accepted and Trusted
<br />✓ Page 2 of 6
<br />(203.2 mm) to 10 inches (254 mm) in slots provided in the
<br />strip. The nails must be located in the center of the
<br />mechanically fastened with noncorrosive, self -tapping,
<br />slot,
<br />leaving a minimum 1/32-inch (0.8 mm) space between the
<br />2112-inch-long (64 mm) screws with minimum 3/8-inch-
<br />diameter (9.5 mm) heads and 1/8-inch-diameter (3 mm)
<br />fastener head and the face of the vinyl nailing strip, to
<br />allow for expansion.
<br />shafts, and with minimum %7-inch-diameter (15.88 mm)
<br />nylon washers, to the exterior of a steel stud wall
<br />The inside and outside corner posts are then installed on
<br />constructed with 'lz-inch-thick (12.7 mm) gypsum wall
<br />all building corners, and accessories are installed around
<br />board on the exterior and 518-inch-thick (15.88 mm) Type X
<br />all wall openings,
<br />gypsum board on the interior. The assembly described in
<br />The first siding panel must be locked into the starter strip
<br />this section must be limited to installations exposed to
<br />and nailed to the building in the center of the nailing slots
<br />maximum basic wind speeds (3-second gust) of 100 miles
<br />every 16 to 24 inches (406.4 mm to 609.6 mm), (Refer to
<br />per hour (161 kmih) on structures a maximum of 40 feet
<br />(12 192 mm) in height under the IBC.
<br />Table 2 of this report.) The nails must be located in the
<br />center of the slot, leaving a minimum 1/32-4nch (0.8 mm)
<br />4.6 Fire -resistance -rated Construction:
<br />space between the fastener head and the face of the vinyl
<br />4.6.1 One -hour Fire -resistance -rated Limited Load -
<br />nailing strip, to allow for expansion. Succeeding panels
<br />bearing Wood Stud Wall: Wood studs must be nominal
<br />shall be similarly installed, locking into the panel below,
<br />2-by-4 Douglas fir marked "STD & BTR, Doug. Fir, S-Dry,"
<br />The horizontal siding panel ends must be overlapped
<br />spaced 16 inches (406 mm) on center. The wall must be
<br />1 inch (2.54 cm) at butt joints and held 114 inch (0,64 cm)
<br />constructed with a single bottom plate and double top
<br />clear of all vertical accessory members at wall ends and
<br />Plates. The wall is a maximum of 10 feet (3.05 m) in
<br />around openings. For vertical siding panel end joint
<br />height with double 2-by-4 wood fire blocking located at
<br />treatment, refer to the manufacturer's installation
<br />8 feet (2-44 rn) above the bottom plate, Stud cavities
<br />instructions.
<br />must be filled with 31/2-inch-thick (88.9 mm), R-11,
<br />4.3 Soffit Installation:
<br />mineral wool insulation batts. The stud wall must be
<br />covered on the exterior with one layer of 1/2-inch-thick
<br />Siding and soffit panels may be installed as horizontal
<br />(12.7 mm), exterior gypsum sheathing, and on the interior
<br />soffits at a maximum span of 24 inches (610 mm), with end
<br />face with a single layer of 5/8-inch-thick (15.9 mm), Type
<br />joints on supports. The panels must be retained by
<br />FSW, fire-resistant gypsum wall board. The exterior wall
<br />F-channels, J-channels or aluminum or vinyl fascia caps,
<br />sheathing must be covered with a water -resistive barrier.
<br />The channels must be fastened to the fascia, nailing strip
<br />The studs are assembled with two 16d smooth box nails
<br />or solid wood sheathing at 16 inches (406 mm) on center,
<br />°3 each end. The wall board is installed vertically with
<br />1 /4-inch-long
<br />with nails of sufficient length to penetrate the nailer 1 inch
<br />(44.5 mm), No, 6, bugle head drywall
<br />(25.4 mm) or to penetrate through the material thickness,
<br />screws spaced 8 inches (203,2 mm) on center around the
<br />whichever is less. The minimum No. 26 gage (0.019 inch)
<br />perimeter of the board and along the studs. Vertical joints
<br />aluminum fascia cap must be bent to form a minimum
<br />are staggered on opposite sides of the wall. The joints
<br />11/2-inch (38 mm) receiving flange at comers; channels
<br />must be treated with ready -mixed joint compound and
<br />shall allow for 1/4 inch (6.4 mm) of expansion at each wall
<br />spark -perforated paper joint reinforcing tape. The siding
<br />To permit expansion, panels are measured to length and
<br />must be attached to the studs using 1'/2-inch-long
<br />cut 112 inch (12.7 mm) less. The panels are first inserted
<br />(38 mm) roofing nails with flat heads, spaced 8 inches
<br />into the wall channels and then into the fascia channels.
<br />(203 mm) on center along the stud.
<br />Each panel must be secured to the fascia or to nailing
<br />The axial load capacity of the wall is limited to a
<br />strips at a maximum of 16 inches (406 mm) on center.
<br />maximum load of 1050 pounds (476.7 kg) per stud or
<br />Adjacent panels must be interlocked. Fascia caps must
<br />32 percent of maximum design load calculated under the
<br />then be installed over the panels, and a drip edge must be
<br />AF&PA National Design Specification for Wood
<br />placed over the cap to reduce moisture intrusion. For porch
<br />Construction (NDS),
<br />ceilings, the ceiling perimeter is framed with the J-channels
<br />or F-channels, and panel placement is as set forth for
<br />4.6.2 Fire -resistance -rated Walls on Buildings of Type
<br />soffits.
<br />V Construction under the IBC: The vinyl siding may be
<br />installed over code-complying,exterior, fire-resistance-
<br />4,4 Fasteners:
<br />rated bearing or nonbearing walls required to be of Type V
<br />Siding, soffits and accessories must be fastened to framing
<br />9
<br />construction under the IBC without affecting the hourly
<br />with either galvanized, aluminum or stainless steel nails
<br />rating of the walls.
<br />with a minimum length of 1112 inches (r 8 mm), a shaft
<br />4,7 Wind Resistance:
<br />diameter of 0.122 inch (3 mm), and a /16-inch-diameter
<br />The design wind pressures must be determined in
<br />�11.11 mm) head. Minimum embedment into studs must be
<br />accordance with Chapter 16 of the IBC, or Section R301.2
<br />/4 inch (19.05 mm). Corrosion -resistant staples may also
<br />of the IRC, and must not exceed the allowable values
<br />be used, where indicated in Table 2- Staples must be
<br />shown in Table 2 of this report.
<br />16 gage, with a minimum length of 13/4 inches (44.45 mm)
<br />and a crown width of ills inch (11,11 mm), Minimum staple
<br />In areas where the basic wind speed (3-second gust)
<br />embedment into studs must be 3/4 inch (19.05 mm).
<br />does not exceed 100 mph (45 m/s) and the building height
<br />is less than or equal to 40 feet (12 192 mm) in Exposure C
<br />Accessory materials such as comers, starter strips and
<br />areas, instaltation must comply with the prescriptive
<br />trim must be fastened in accordance with the
<br />requirements of iBC Section 1465.14.
<br />manufacturer's instructions.
<br />In areas where the basic wind speed (3-second gust)
<br />4.5 Types I, II, flu and IV (Noncombustible)
<br />does not exceed 110 mph (49 m/s) in Exposure B areas
<br />Construction:
<br />and does not exceed 90 mph (40 m/s) in Exposure C areas
<br />The vinyl siding may be installed on the exterior of
<br />or 85 mph (37 m/s) in Exposure D areas, installation must
<br />comply with the prescriptive requirements of IRC Section
<br />buildings of any type of construction when installed over
<br />R703.4. For applications in excess of the prescriptive
<br />maximum 1-inch-thick (25.4 mm) expanded polystyrene
<br />insulation
<br />requirements, the installation must be in accordance with
<br />[1 pound per cubic foot (16 kg/m3)] and
<br />IRC Section R301.2.1.
<br />ESR-1066 Most Widely Accepted and Trusted
<br />Wind resistance of the soffit panels is outside the scope
<br />of this report.
<br />Resistance to positive and negative wind loads is
<br />determined by structural capacity of the substrate.
<br />5.0 CONDITIONS OF USE
<br />The CertainTeed Vinyl Sidings and Soffits described in this
<br />report comply with, or are suitable alternatives to what is
<br />specified in, those codes listed in Section 1.0 of this report,
<br />subject to the following conditions:
<br />5.1 Installation complies with this report, the
<br />manufacturer's published instructions and the
<br />applicable code. In the event of a conflict between the
<br />manufacturer's published installation instructions and
<br />this report, this report governs.
<br />5,2 The siding is limited to design wind pressures shown
<br />in Table 2 of this report.
<br />5.3 In jurisdictions adopting the IRC, the siding must be
<br />installed in accordance with IRC Table R703.4 and
<br />limited to areas where the design wind pressure does
<br />not exceed the values shown in Table 2 of this report.
<br />5.4 The exterior walls must be braced or sheathed to
<br />resist racking loads with approved materials in
<br />accordance with the requirements of the applicable
<br />building code.
<br />5.5 When installation is on Types I, 119 111 and IV
<br />construction (IBC) and noncombustible construction
<br />(UBC, BNBC and SBC), and fire -resistance -rated
<br />construction, refer to Sections 4.5 and 4.6 of this
<br />report, respectively.
<br />5.6 The siding must be installed only on exterior walls
<br />covered by a solid sheathing capable of supporting
<br />the imposed loads, including but not limited to positive
<br />and negative transverse wind loads.
<br />5.7 The siding may be installed on buildings of any
<br />construction type under the IBC or buildings under the
<br />IRC, and at a fire separation distance of greater than
<br />5 feet (1524 mm) in accordance with IBC Section
<br />1406,2.1.2 or IRC Table R302.1, as applicable,
<br />5.8 The sheathing must be covered with a water -resistive
<br />barrier, as required by the applicable code.
<br />5.9 The siding is manufactured in Jackson, Michigan, -
<br />Claremont, North Carolina; Joplin, Missouri; and
<br />Williamsport, Maryland, under a quality control
<br />program with inspections by Architectural Testing, Inc.
<br />(AA-676).
<br />6.0 EVIDENCE SUBMITTED
<br />6.1 Data in accordance with the ICC-ES Acceptance
<br />Criteria for Vinyl Siding (AC37), dated June 2009.
<br />6.2 Test reports in accordance with UBC 26-4, UBC 8-1,
<br />NFPA 268 and ASTM E 119.
<br />7.0 IDENTIFICATION
<br />The vinyl sidings and soffits described in this report are
<br />identified by a stamp bearing the brand name
<br />(CertainTeed, Wolverine, Vytec or Vinyl Carpentry), the
<br />product name and style, the statement "Conforms to ASTM
<br />Specification D 3679," the statement "Conforms to UBC
<br />Standard 14-2" and the evaluation report number
<br />(ESR-1066).
<br />In jurisdictions enforcing the IBC or UBC, foam plastic
<br />insulation used for noncombustible construction must be
<br />identified in accordance with IBC Section 2603.5.6 or UBC
<br />Section 2602.2.
<br />Page 3 of 6
<br />8.0 OTHER CODES
<br />8.1 Evaluation Scope:
<br />In addition to the codes referenced in Section 1.0, the
<br />products described in this report were evaluated for
<br />compliance with the requirements of the following codes:
<br />■ 2006 International Building Code° (2006 IBC)
<br />■ 2006 International Residential Code° (2006 IRC)
<br />■ 1997 Uniform Building CodeTM (UBC)
<br />■ BOCe National Building Code/1999 (BNBC)
<br />■ 1997 Standard Building Code' (SBC)
<br />The products comply with the above -mentioned codes as
<br />described in Section 2.0 through 7.0 of this report, with the
<br />revisions noted below:
<br />8.2 Uses:
<br />See Section 2.0.
<br />8.3 Description:
<br />See Section 3.0.
<br />8.4 Installation:
<br />Installation must be in accordance with 2006 IBC Section
<br />1405.13. Section 4.0 applies, with revisions as noted
<br />below.
<br />• Types I, 11, III and IV Construction (2006 IBC) and
<br />Noncombustible Construction (UBC, BNBC and
<br />SBC): See Section 4.5,except the assembly described
<br />in this section must be limited to installations exposed to
<br />maximum basic wind speeds (3-second gust) of
<br />100 miles per hour (161 km/h) on structures a maximum
<br />of 40 feet (12 192 mm) in height under the 2006 IBC
<br />and the BNBC; maximum basic wind speeds (fastest
<br />mite) of 80 miles per hour (129 km/h) on structures a
<br />maximum of 40 feet (12 192 mm) in height in Exposure
<br />C areas under the UBC; and maximum basic wind
<br />speeds of 70 miles per hour (112 km/h) on structures a
<br />maximum of 40 feet (12 192 mm) in height in Exposure
<br />C areas under Section 1606.2 of the SBC.
<br />• One -Hour Fire -resistance -rated limited Load -
<br />Bearing Wood Stud Wall: See Section 4.6.1.
<br />• Fire -Resistance -Rated Walls on Buildings of Type
<br />V Construction Under the IBC (Type 5 Under the
<br />BNBC, Type VI Under the SBC, Type V Under the
<br />UBC): See Section 4.6.2.
<br />• Wind resistance: See Section 4.7, except design wind
<br />pressures must be determined in accordance with
<br />Chapter 16 of the UBC, BNBC or SBC, as applicable or
<br />with 2006 IRC Section R301.2.1, Under the UBC, where
<br />the basic wind speed does not exceed 80 mph (35 m/s)
<br />(fastest mile) and the building height is less than or
<br />equal to 40 feet (12 192 mm) in Exposure C areas,
<br />installation must comply with the prescriptive
<br />requirements of 2006 iBC Section 1405.13, BNBC
<br />Section 1406.3.3, SBC Section 1403.9 or UBC Section
<br />1405, as applicable.
<br />For applications in excess of the prescriptive
<br />requirements, the installation must be in accordance
<br />with 2006 IRC Section R301.2.1.1.
<br />8.5 Conditions Of Use:
<br />See Section 5,0, except that (Section 5.7) a fire separation
<br />distance of greater than 5 feet must be in accordance with
<br />2006 iBC Section 704.5.
<br />ESR 1066 ` Most Widely Accepted and Trusted
<br />m.__..: _..... .,
<br />TABLE 1-VINYL SIDING AND SOFFIT
<br />PRODUCT
<br />NAME
<br />PRODUCT
<br />CODE
<br />PRODUCT
<br />STYLE
<br />�THICKNESS
<br />h)
<br />LENGTH
<br />(feet -inches)
<br />The following products are sold under the brand name CertainTeed
<br />Monogram46
<br />33101
<br />33110
<br />33111
<br />33122
<br />33103
<br />33125
<br />Double 4-inch
<br />Double 4-inch
<br />Double 4-inch
<br />Double 5-inch
<br />Double 5-inch DutchLap
<br />Double 5-inch Dutchlap
<br />0-046
<br />0.046
<br />0.046
<br />0_046
<br />0.046
<br />0,046
<br />12-6
<br />12-6
<br />12-6
<br />12-0
<br />12-0
<br />12-0
<br />Monogram 46L
<br />33114
<br />33139
<br />33126
<br />33140
<br />Double 4-inch
<br />Double 4-inch
<br />Double 5-inch DutchLap
<br />Double 5-'inch DutchLap
<br />0.046
<br />0 046
<br />0-046
<br />0.046
<br />16-8
<br />20 0
<br />16-0
<br />20-0
<br />Classic
<br />36110
<br />36119
<br />36122
<br />Double 4-inch
<br />Double 4'/24nch DutchLap
<br />Double 5-inch
<br />0.044
<br />0.044
<br />0.044
<br />12-6
<br />12-1
<br />12-0
<br />Mainstreet
<br />39131
<br />39111
<br />39110
<br />39122
<br />39113
<br />39125
<br />Triple 3-inch
<br />Double 4-inch
<br />Double 4-inch
<br />Double 5-inch
<br />Double 4-inch DutchLap
<br />Double 5-inch DutchLap
<br />0.042
<br />0.042
<br />0.042
<br />0.042
<br />0.042
<br />0.042
<br />12-1
<br />12-6
<br />12-6
<br />12-0
<br />12-6
<br />12-0
<br />39104
<br />Single 84nch
<br />0.042
<br />12-6
<br />39102
<br />6'/2-inch Beaded
<br />0.042
<br />12-4
<br />Board & Batten
<br />34137
<br />Single 8 Vertical
<br />0.048
<br />12-6
<br />Carolina Beaded
<br />34138
<br />38102
<br />Single 8 Vertical
<br />6'/.-inch Beaded
<br />0.048
<br />0.044
<br />10-0
<br />12-4
<br />60106
<br />Single 7-inch
<br />0-050
<br />10-1
<br />Northwoods
<br />60107
<br />Single 10-inch Shake
<br />0-050
<br />10-0
<br />60148 Single 94nch Shake
<br />The fnllnwir r-4, t. __ __jA
<br />0.050
<br />10-4
<br />Restoration Smooth
<br />36132
<br />Triple 34nch
<br />Double 4'1zinch
<br />0.044
<br />0.044
<br />12-136118
<br />12-1
<br />Classic
<br />36110
<br />36119
<br />36122
<br />Double 4 inch
<br />Double 41/2-inch DutchLap
<br />Double 54rich
<br />0.044
<br />0.044
<br />0.044
<br />12-6
<br />12-1
<br />12-0
<br />American Legend
<br />Encore
<br />40131
<br />40110
<br />40111
<br />40122
<br />40119
<br />40102
<br />40105
<br />43130
<br />43110
<br />43122
<br />Triple 7inch
<br />Double 44neh
<br />Double 4-inch
<br />Double 5-inch
<br />Double 4'/2-inch DutchLap
<br />6'1z4nch Beaded
<br />Single 8-inch
<br />Triple 34nch
<br />Double 4-inch 1
<br />Double 54mh
<br />0.042
<br />0.042
<br />0.042
<br />0.042
<br />0.042
<br />0.042
<br />0.042
<br />0.040
<br />0.040
<br />Q 040
<br />12-1
<br />12-6
<br />12-6
<br />12-0
<br />12-1
<br />12-4
<br />12-6
<br />12-1
<br />12-6
<br />12-0
<br />43119
<br />61110
<br />Double 4'/2-inch DutchLap
<br />Double 4-inch
<br />0.040
<br />0.040
<br />12-1
<br />12-6
<br />Newtown
<br />61122
<br />Double 5-inch
<br />0,040
<br />12-6
<br />61125
<br />Double 5-inch DutchLap
<br />0-040
<br />12-6
<br />ESR-1066 ` Most Widely Accepted and Trusted
<br />TABLE 1-VINYL SIDING AND SOFFIT (Continued)
<br />Page 5 of 6
<br />PRODUCT
<br />NAME
<br />PRODUCT
<br />CODE
<br />PRODUCT
<br />STYLE
<br />THICKNESS
<br />(inch)
<br />LENGTH
<br />(feet -inches)
<br />The following products are sold under the brand name Vytec
<br />Nantucket
<br />Double 44nch
<br />.040
<br />12-3
<br />Double 4-inch Dutchlap
<br />.040
<br />12-3.
<br />Double 4'IL4nch Dutchlap
<br />.040
<br />12-11 -
<br />Beaded
<br />Single 6'/24nch
<br />.048
<br />12-4
<br />Proside
<br />Double 44nch
<br />.042
<br />12-3
<br />Double 4'Irinch
<br />.042
<br />12-11
<br />Double 4'/2-inch Dutchlap
<br />.042
<br />12-3
<br />Single 8-inch
<br />.042
<br />12-3
<br />Triple 3
<br />Triple 3-inch
<br />,042
<br />12-11
<br />Prestige
<br />Double 41/24nch
<br />.044
<br />12-11
<br />Double 4'/24nch Dutchlap
<br />.044
<br />12-11
<br />Double 54rr-h Dutchlap
<br />.044
<br />12-11
<br />Eminence
<br />Double 4'lz-inch
<br />.046
<br />13-4
<br />Double 4'/z4nch
<br />.046
<br />20-0
<br />Double 41/2-inch Dutchlap
<br />.046
<br />13-4
<br />Double 41/2-inch Dutchlap
<br />046
<br />20.0
<br />Board and Batten
<br />Single 6'/2
<br />76E0
<br />10-0
<br />The following products are sold under the brand name Vinyl Carpentry:
<br />Triple 31/3-inch
<br />InvisVent Soffit
<br />46228
<br />Triple 3'/
<br />P 3-inch Vented Soffit
<br />0.044
<br />12-6
<br />Triple 3' enrich
<br />Soffit /Verticala
<br />46229
<br />Triple 3'/ -inch Soffit i Vertical Sidi rig
<br />0.044
<br />12-6
<br />IronMax Soffit/ Vertical
<br />47201
<br />Double 5-inch Solid Soffit/ Vertical
<br />Siding
<br />0.046
<br />12-0
<br />47205
<br />Double 5-inch Fully Vented
<br />0.046
<br />12-0
<br />Universal Soffit/ Vertical
<br />48224
<br />Triple 44nch Fully Vented
<br />0.040
<br />12-0
<br />48216
<br />Triple 44nch Solid Soffit/ Vertical
<br />Siding
<br />0.040
<br />12-0
<br />48220
<br />Triple 4-inch Center Vented
<br />0.040
<br />12-0
<br />Beaded Soffit/ Vertical
<br />46209
<br />Triple 2-inch Solid Soffit/ Vertical
<br />Siding
<br />0.039
<br />12-6
<br />46211
<br />Triple 2-inch Vented
<br />0.039
<br />12-6
<br />Value Soffit
<br />49224
<br />Triple 44nch Fully Vented
<br />0.036
<br />12-0
<br />49216
<br />Triple 4-inch Solid Soffit
<br />0.036
<br />12-0
<br />49220
<br />Triple 4-inch Center Vented
<br />0.036
<br />12-0
<br />ESR-1066 ' Most Widely Accepted and Trusted Page 6 of 6
<br />TABLE 2-ALLOWABLE NEGATIVE WIND LOADS
<br />SIDING
<br />MAXIMUM STUD'
<br />SPACING (inches)
<br />FASTENER'
<br />ALLOWABLE NEGATIVE
<br />WIND LOAD (psf)
<br />SBC
<br />BNBC
<br />IBC/IRC
<br />UBC
<br />Monogram 46 D5
<br />16
<br />Nail to studs
<br />53
<br />53
<br />53
<br />33
<br />16
<br />Staple to studs
<br />47
<br />47
<br />47
<br />29
<br />Monogram 46 D5DL
<br />16
<br />Nail to studs
<br />76
<br />76
<br />76
<br />47
<br />16
<br />Staple to studs
<br />49
<br />49
<br />49
<br />31
<br />24
<br />Nail to studs
<br />44
<br />44
<br />44
<br />28
<br />Monogram 46 D4
<br />16
<br />Nair to studs
<br />91
<br />91
<br />91
<br />57
<br />16
<br />Staple to studs
<br />58
<br />58
<br />58
<br />36
<br />Monogram 46L D4
<br />16
<br />Nail to studs
<br />87
<br />87
<br />87
<br />54
<br />Monogram 46L D5DL
<br />16
<br />Nail to studs
<br />78
<br />78
<br />78
<br />49
<br />Classic D5
<br />16
<br />Nail to studs
<br />67
<br />67
<br />67
<br />42
<br />16
<br />Staple to studs
<br />36
<br />36
<br />36
<br />22
<br />24
<br />Nail to studs
<br />49
<br />49
<br />49
<br />31
<br />Classic D4
<br />16
<br />Nail to studs
<br />80
<br />80
<br />80
<br />50
<br />Mainstreet D5
<br />16
<br />Nail to studs
<br />76
<br />76
<br />76
<br />47
<br />16
<br />Staple to studs
<br />38
<br />38
<br />38
<br />24
<br />24
<br />Nail to studs
<br />47
<br />47
<br />47
<br />29
<br />Mainstreet D5DL
<br />16
<br />Nail to studs
<br />62
<br />62
<br />62
<br />39
<br />16
<br />Staple to studs
<br />58
<br />58
<br />58
<br />36
<br />24
<br />Nail to studs
<br />42
<br />42
<br />42
<br />26
<br />24
<br />Staple to studs
<br />36
<br />36
<br />36
<br />22
<br />Mainstreet D4
<br />16
<br />Nail to studs
<br />53
<br />53
<br />53
<br />33
<br />16
<br />Staple to studs
<br />82
<br />82
<br />82
<br />51
<br />Carolina Beaded
<br />16
<br />Nail to studs
<br />67
<br />67
<br />67
<br />42
<br />16
<br />Staple to studs
<br />56
<br />56
<br />56
<br />35
<br />24
<br />Nail t° studs
<br />36
<br />36
<br />36
<br />22
<br />24
<br />Staple to studs
<br />38
<br />38
<br />38
<br />24
<br />Northwoods S7
<br />Northwoods S10
<br />16
<br />16
<br />Nail to studs
<br />Nail to studs
<br />60
<br />42
<br />60
<br />42
<br />60
<br />42
<br />38
<br />26
<br />Northwoods S9
<br />16
<br />Nail to studs
<br />42
<br />42
<br />42
<br />26
<br />Board & Batten
<br />12
<br />Nail to sheathing
<br />62
<br />62
<br />62
<br />39
<br />American Legend D5
<br />16
<br />Nail to studs
<br />36
<br />36
<br />36 1
<br />22
<br />16
<br />Staple to studs
<br />33
<br />33
<br />33
<br />21
<br />American Legend D4
<br />16
<br />Nail to studs
<br />60
<br />60
<br />60
<br />38
<br />16
<br />Staple to studs
<br />58
<br />58
<br />58
<br />36
<br />Encore D5
<br />16
<br />Nail to studs
<br />44
<br />44
<br />44
<br />28
<br />16
<br />Staple to studs
<br />69
<br />69
<br />69
<br />43
<br />24
<br />Nail to studs
<br />33
<br />33
<br />33
<br />21
<br />24
<br />Staple to studs
<br />44
<br />44
<br />44
<br />28
<br />Encore D4
<br />16
<br />Nail to studs
<br />64
<br />64
<br />64
<br />40
<br />16
<br />Staple to studs
<br />53
<br />53
<br />53
<br />33
<br />Newtown D4
<br />16
<br />Nail to studs
<br />51
<br />51
<br />51
<br />32
<br />Newtown D5
<br />16
<br />Nail to studs
<br />38
<br />38
<br />38
<br />24
<br />Newtown D5DL
<br />Triple 3-1/3 Soffit / Vertical
<br />For Slt 1 inrh = 95 d mm 1 .,mot -
<br />16
<br />12
<br />n nA7n t.n_
<br />Nail to studs
<br />Nail to sheathing
<br />22
<br />56
<br />22
<br />22
<br />14
<br />56
<br />56
<br />35
<br />2Studs are minimum 2-by-4 wood with a minimum specific gravity of 0.42.
<br />Nails and staples must be as specified in Section 4.4.
<br />m
<br />U Z In
<br />Z - m
<br />`uJ Q
<br />0 O.
<br />O
<br />ZCIO -__ 00
<br />Ul 0 LLN -
<br />J _N
<br />� ' :5 y.t0
<br />a
<br />t
<br />_ (D to
<br />...� W in 0 �_q O fq
<br />L"
<br />0 0-
<br />.. Q U 7-
<br />m
<br />N
<br />Q �m
<br />inn
<br />X TN
<br />o �m
<br />ut
<br />utnt FU u
<br />mIL
<br />o
<br />air■awao■rA■ri�n■
<br />-1
<br />4
<br />II I „il�� :I161IIMI I -T-
<br />
|