Laserfiche WebLink
t <br />IMES Evaluation Report <br />-106 <br />Reissued May 1, 2010 <br />This report is subject to re-examinatfon in two years <br />wwwJcc-es.orq 1 (800) 423-6587 1 (562) 699-0543 <br />A Subsidiary of the international Code Council® <br />DIVISION: 07 00 00-THERMAL AND MOISTURE <br />construction types over approved sheathings capable of <br />PROTECTION <br />supporting the imposed loads, including but not limited to <br />Section: 07 46 33-Plastic Siding <br />positive and negative transverse wind load; and as <br />closures on the underside of exterior roof eaves (soffits). <br />REPORT HOLDER: <br />3,0 DESCRIPTION <br />CERTAINTEED CORPORATION <br />The vinyl sidings and soffits are extruded from polyvinyl <br />803 BELDEN ROAD <br />chloride (PVC) resins. The siding panels conform to the <br />JACKSON, MICHIGAN 49203 <br />requirements of ASTM D 3679 and are formed with an <br />(800) 233-8990 <br />upper edge having nail slots and a lower edge that hooks <br />A Lcertainteed.com <br />into the upper edge of the lower course. The accessory <br />items, used to detail the application of the product as an <br />EVALUATION SUBJECT: <br />exterior wall covering, are of the same material. <br />CERTAINTEED VINYL SIDING AND SOFFIT <br />All panels are designed with receiving legs and a nailing <br />tl8-inch-by-%-inch <br />flange with a 1 (28.58 trim by 9.53 mm) <br />ADDITIONAL LiSTEES: <br />prepurtched elongated nailing slot spaced 2 inches <br />(50.80 mm) on center. All siding panels used in horizontal <br />VINYL CARPENTRY <br />applications have weep holes prepunched at a minimum of <br />750 EAST SWEDESFORD ROAD <br />18 inches (457.2 mm) on center on the underside to <br />VALLEY FORGE, PENNSYLVANIA 19482 <br />provide ventilation and drainage. <br />(800) 233-8990 <br />The panels are available in different colors with smooth <br />finish or embossed with a matt or wood -grain texture. The <br />VYTEC <br />panels range in thickness from 0.036 inch to 0.50 inch <br />750 EAST SWEDESFORD ROAD <br />(0.91 mm to 1.27 mm). <br />VALLEY FORGE, PENNSYLVANIA 19482 <br />The accessory shapes include a fascia, "F" shaped trim, <br />(800) 233-6990 <br />"J" shaped trim, drip cap, starter strips, inside/outside <br />comers, quarter round soffit molding, undersills, soffit cove <br />WOLVERINE SIDING SYSTEMS <br />trim, and "H" divider bar. The thicknesses of accessories <br />750 EAST SWEDESFORD ROAD <br />range from 0.040 to 0.050 inch (1.02 to 1.27 mm). <br />VALLEY FORGE, PENNSYLVANIA 19482 <br />Refer to Table 1 for panel thicknesses, lengths and <br />(800) 233-8990 <br />profiles within the scope of this report. <br />1.0 EVALUATION SCOPE <br />4,0 INSTALLATION <br />Compliance with the following codes: <br />4.1 General: <br />® <br />■ 2009 International Building Code (IBC) <br />Installation of the system, including the panels, corners, <br />starter strips, trim and other accessory items, must be <br />■ 2009 International Residential Code (IRC) <br />installed in accordance with IBC Section 1405.14 or IRC <br />■ Other Codes (see Section 8.0} <br />Section R703.4, as applicable, ASTM D 4756, the <br />manufacturers published installation instructions, the <br />Properties evaluated: <br />and this report. <br />■ Exterior veneer <br />4.2 Siding Installation: <br />■ Wind load resistance -transverse <br />u s ailed over solid plywood structural <br />sheathing complying with DOC PS 1, or Exposure 1 <br />■ Types I, II, III and IV (noncombustible) construction <br />oriented strand board (OSB) sheathing complying with <br />■ Fire -resistance -rated construction <br />DOC PS 2, covered with an approved water -resistive <br />barrier as required by the applicable code. <br />2.0 USES <br />The method of application of the siding is by first <br />CertainTeed vinyl sidings, which are also sold under the <br />installing a starter strip horizontally, along the bottom of the <br />brand names Wolverine, Vytec and Vinyl Carpentry, are <br />building matching the lowest corner of the building. The <br />used as exterior wall coverings on buildings of all <br />starter strip is then nailed to the building every 8 inches <br />]CC -ES Evaluation Reports are not to be construed as representing aesthetics or onv other auributes not specifically addressed, nor are thev to be construed ' <br />as an endorsement of the subject of the report or a recommendation for its use. There is no aarrontr by ICC Evahration Service, LLC, <br />to atn7 f nding or other matter in this report, or as to ant product covered bt the report. <br />erpr"' s or implied, as <br />Copyright © 2010 <br />Page 1 of 6 <br />ESR-1066 i Most Widely Accepted and Trusted <br />✓ Page 2 of 6 <br />(203.2 mm) to 10 inches (254 mm) in slots provided in the <br />strip. The nails must be located in the center of the <br />mechanically fastened with noncorrosive, self -tapping, <br />slot, <br />leaving a minimum 1/32-inch (0.8 mm) space between the <br />2112-inch-long (64 mm) screws with minimum 3/8-inch- <br />diameter (9.5 mm) heads and 1/8-inch-diameter (3 mm) <br />fastener head and the face of the vinyl nailing strip, to <br />allow for expansion. <br />shafts, and with minimum %7-inch-diameter (15.88 mm) <br />nylon washers, to the exterior of a steel stud wall <br />The inside and outside corner posts are then installed on <br />constructed with 'lz-inch-thick (12.7 mm) gypsum wall <br />all building corners, and accessories are installed around <br />board on the exterior and 518-inch-thick (15.88 mm) Type X <br />all wall openings, <br />gypsum board on the interior. The assembly described in <br />The first siding panel must be locked into the starter strip <br />this section must be limited to installations exposed to <br />and nailed to the building in the center of the nailing slots <br />maximum basic wind speeds (3-second gust) of 100 miles <br />every 16 to 24 inches (406.4 mm to 609.6 mm), (Refer to <br />per hour (161 kmih) on structures a maximum of 40 feet <br />(12 192 mm) in height under the IBC. <br />Table 2 of this report.) The nails must be located in the <br />center of the slot, leaving a minimum 1/32-4nch (0.8 mm) <br />4.6 Fire -resistance -rated Construction: <br />space between the fastener head and the face of the vinyl <br />4.6.1 One -hour Fire -resistance -rated Limited Load - <br />nailing strip, to allow for expansion. Succeeding panels <br />bearing Wood Stud Wall: Wood studs must be nominal <br />shall be similarly installed, locking into the panel below, <br />2-by-4 Douglas fir marked "STD & BTR, Doug. Fir, S-Dry," <br />The horizontal siding panel ends must be overlapped <br />spaced 16 inches (406 mm) on center. The wall must be <br />1 inch (2.54 cm) at butt joints and held 114 inch (0,64 cm) <br />constructed with a single bottom plate and double top <br />clear of all vertical accessory members at wall ends and <br />Plates. The wall is a maximum of 10 feet (3.05 m) in <br />around openings. For vertical siding panel end joint <br />height with double 2-by-4 wood fire blocking located at <br />treatment, refer to the manufacturer's installation <br />8 feet (2-44 rn) above the bottom plate, Stud cavities <br />instructions. <br />must be filled with 31/2-inch-thick (88.9 mm), R-11, <br />4.3 Soffit Installation: <br />mineral wool insulation batts. The stud wall must be <br />covered on the exterior with one layer of 1/2-inch-thick <br />Siding and soffit panels may be installed as horizontal <br />(12.7 mm), exterior gypsum sheathing, and on the interior <br />soffits at a maximum span of 24 inches (610 mm), with end <br />face with a single layer of 5/8-inch-thick (15.9 mm), Type <br />joints on supports. The panels must be retained by <br />FSW, fire-resistant gypsum wall board. The exterior wall <br />F-channels, J-channels or aluminum or vinyl fascia caps, <br />sheathing must be covered with a water -resistive barrier. <br />The channels must be fastened to the fascia, nailing strip <br />The studs are assembled with two 16d smooth box nails <br />or solid wood sheathing at 16 inches (406 mm) on center, <br />°3 each end. The wall board is installed vertically with <br />1 /4-inch-long <br />with nails of sufficient length to penetrate the nailer 1 inch <br />(44.5 mm), No, 6, bugle head drywall <br />(25.4 mm) or to penetrate through the material thickness, <br />screws spaced 8 inches (203,2 mm) on center around the <br />whichever is less. The minimum No. 26 gage (0.019 inch) <br />perimeter of the board and along the studs. Vertical joints <br />aluminum fascia cap must be bent to form a minimum <br />are staggered on opposite sides of the wall. The joints <br />11/2-inch (38 mm) receiving flange at comers; channels <br />must be treated with ready -mixed joint compound and <br />shall allow for 1/4 inch (6.4 mm) of expansion at each wall <br />spark -perforated paper joint reinforcing tape. The siding <br />To permit expansion, panels are measured to length and <br />must be attached to the studs using 1'/2-inch-long <br />cut 112 inch (12.7 mm) less. The panels are first inserted <br />(38 mm) roofing nails with flat heads, spaced 8 inches <br />into the wall channels and then into the fascia channels. <br />(203 mm) on center along the stud. <br />Each panel must be secured to the fascia or to nailing <br />The axial load capacity of the wall is limited to a <br />strips at a maximum of 16 inches (406 mm) on center. <br />maximum load of 1050 pounds (476.7 kg) per stud or <br />Adjacent panels must be interlocked. Fascia caps must <br />32 percent of maximum design load calculated under the <br />then be installed over the panels, and a drip edge must be <br />AF&PA National Design Specification for Wood <br />placed over the cap to reduce moisture intrusion. For porch <br />Construction (NDS), <br />ceilings, the ceiling perimeter is framed with the J-channels <br />or F-channels, and panel placement is as set forth for <br />4.6.2 Fire -resistance -rated Walls on Buildings of Type <br />soffits. <br />V Construction under the IBC: The vinyl siding may be <br />installed over code-complying,exterior, fire-resistance- <br />4,4 Fasteners: <br />rated bearing or nonbearing walls required to be of Type V <br />Siding, soffits and accessories must be fastened to framing <br />9 <br />construction under the IBC without affecting the hourly <br />with either galvanized, aluminum or stainless steel nails <br />rating of the walls. <br />with a minimum length of 1112 inches (r 8 mm), a shaft <br />4,7 Wind Resistance: <br />diameter of 0.122 inch (3 mm), and a /16-inch-diameter <br />The design wind pressures must be determined in <br />�11.11 mm) head. Minimum embedment into studs must be <br />accordance with Chapter 16 of the IBC, or Section R301.2 <br />/4 inch (19.05 mm). Corrosion -resistant staples may also <br />of the IRC, and must not exceed the allowable values <br />be used, where indicated in Table 2- Staples must be <br />shown in Table 2 of this report. <br />16 gage, with a minimum length of 13/4 inches (44.45 mm) <br />and a crown width of ills inch (11,11 mm), Minimum staple <br />In areas where the basic wind speed (3-second gust) <br />embedment into studs must be 3/4 inch (19.05 mm). <br />does not exceed 100 mph (45 m/s) and the building height <br />is less than or equal to 40 feet (12 192 mm) in Exposure C <br />Accessory materials such as comers, starter strips and <br />areas, instaltation must comply with the prescriptive <br />trim must be fastened in accordance with the <br />requirements of iBC Section 1465.14. <br />manufacturer's instructions. <br />In areas where the basic wind speed (3-second gust) <br />4.5 Types I, II, flu and IV (Noncombustible) <br />does not exceed 110 mph (49 m/s) in Exposure B areas <br />Construction: <br />and does not exceed 90 mph (40 m/s) in Exposure C areas <br />The vinyl siding may be installed on the exterior of <br />or 85 mph (37 m/s) in Exposure D areas, installation must <br />comply with the prescriptive requirements of IRC Section <br />buildings of any type of construction when installed over <br />R703.4. For applications in excess of the prescriptive <br />maximum 1-inch-thick (25.4 mm) expanded polystyrene <br />insulation <br />requirements, the installation must be in accordance with <br />[1 pound per cubic foot (16 kg/m3)] and <br />IRC Section R301.2.1. <br />ESR-1066 Most Widely Accepted and Trusted <br />Wind resistance of the soffit panels is outside the scope <br />of this report. <br />Resistance to positive and negative wind loads is <br />determined by structural capacity of the substrate. <br />5.0 CONDITIONS OF USE <br />The CertainTeed Vinyl Sidings and Soffits described in this <br />report comply with, or are suitable alternatives to what is <br />specified in, those codes listed in Section 1.0 of this report, <br />subject to the following conditions: <br />5.1 Installation complies with this report, the <br />manufacturer's published instructions and the <br />applicable code. In the event of a conflict between the <br />manufacturer's published installation instructions and <br />this report, this report governs. <br />5,2 The siding is limited to design wind pressures shown <br />in Table 2 of this report. <br />5.3 In jurisdictions adopting the IRC, the siding must be <br />installed in accordance with IRC Table R703.4 and <br />limited to areas where the design wind pressure does <br />not exceed the values shown in Table 2 of this report. <br />5.4 The exterior walls must be braced or sheathed to <br />resist racking loads with approved materials in <br />accordance with the requirements of the applicable <br />building code. <br />5.5 When installation is on Types I, 119 111 and IV <br />construction (IBC) and noncombustible construction <br />(UBC, BNBC and SBC), and fire -resistance -rated <br />construction, refer to Sections 4.5 and 4.6 of this <br />report, respectively. <br />5.6 The siding must be installed only on exterior walls <br />covered by a solid sheathing capable of supporting <br />the imposed loads, including but not limited to positive <br />and negative transverse wind loads. <br />5.7 The siding may be installed on buildings of any <br />construction type under the IBC or buildings under the <br />IRC, and at a fire separation distance of greater than <br />5 feet (1524 mm) in accordance with IBC Section <br />1406,2.1.2 or IRC Table R302.1, as applicable, <br />5.8 The sheathing must be covered with a water -resistive <br />barrier, as required by the applicable code. <br />5.9 The siding is manufactured in Jackson, Michigan, - <br />Claremont, North Carolina; Joplin, Missouri; and <br />Williamsport, Maryland, under a quality control <br />program with inspections by Architectural Testing, Inc. <br />(AA-676). <br />6.0 EVIDENCE SUBMITTED <br />6.1 Data in accordance with the ICC-ES Acceptance <br />Criteria for Vinyl Siding (AC37), dated June 2009. <br />6.2 Test reports in accordance with UBC 26-4, UBC 8-1, <br />NFPA 268 and ASTM E 119. <br />7.0 IDENTIFICATION <br />The vinyl sidings and soffits described in this report are <br />identified by a stamp bearing the brand name <br />(CertainTeed, Wolverine, Vytec or Vinyl Carpentry), the <br />product name and style, the statement "Conforms to ASTM <br />Specification D 3679," the statement "Conforms to UBC <br />Standard 14-2" and the evaluation report number <br />(ESR-1066). <br />In jurisdictions enforcing the IBC or UBC, foam plastic <br />insulation used for noncombustible construction must be <br />identified in accordance with IBC Section 2603.5.6 or UBC <br />Section 2602.2. <br />Page 3 of 6 <br />8.0 OTHER CODES <br />8.1 Evaluation Scope: <br />In addition to the codes referenced in Section 1.0, the <br />products described in this report were evaluated for <br />compliance with the requirements of the following codes: <br />■ 2006 International Building Code° (2006 IBC) <br />■ 2006 International Residential Code° (2006 IRC) <br />■ 1997 Uniform Building CodeTM (UBC) <br />■ BOCe National Building Code/1999 (BNBC) <br />■ 1997 Standard Building Code' (SBC) <br />The products comply with the above -mentioned codes as <br />described in Section 2.0 through 7.0 of this report, with the <br />revisions noted below: <br />8.2 Uses: <br />See Section 2.0. <br />8.3 Description: <br />See Section 3.0. <br />8.4 Installation: <br />Installation must be in accordance with 2006 IBC Section <br />1405.13. Section 4.0 applies, with revisions as noted <br />below. <br />• Types I, 11, III and IV Construction (2006 IBC) and <br />Noncombustible Construction (UBC, BNBC and <br />SBC): See Section 4.5,except the assembly described <br />in this section must be limited to installations exposed to <br />maximum basic wind speeds (3-second gust) of <br />100 miles per hour (161 km/h) on structures a maximum <br />of 40 feet (12 192 mm) in height under the 2006 IBC <br />and the BNBC; maximum basic wind speeds (fastest <br />mite) of 80 miles per hour (129 km/h) on structures a <br />maximum of 40 feet (12 192 mm) in height in Exposure <br />C areas under the UBC; and maximum basic wind <br />speeds of 70 miles per hour (112 km/h) on structures a <br />maximum of 40 feet (12 192 mm) in height in Exposure <br />C areas under Section 1606.2 of the SBC. <br />• One -Hour Fire -resistance -rated limited Load - <br />Bearing Wood Stud Wall: See Section 4.6.1. <br />• Fire -Resistance -Rated Walls on Buildings of Type <br />V Construction Under the IBC (Type 5 Under the <br />BNBC, Type VI Under the SBC, Type V Under the <br />UBC): See Section 4.6.2. <br />• Wind resistance: See Section 4.7, except design wind <br />pressures must be determined in accordance with <br />Chapter 16 of the UBC, BNBC or SBC, as applicable or <br />with 2006 IRC Section R301.2.1, Under the UBC, where <br />the basic wind speed does not exceed 80 mph (35 m/s) <br />(fastest mile) and the building height is less than or <br />equal to 40 feet (12 192 mm) in Exposure C areas, <br />installation must comply with the prescriptive <br />requirements of 2006 iBC Section 1405.13, BNBC <br />Section 1406.3.3, SBC Section 1403.9 or UBC Section <br />1405, as applicable. <br />For applications in excess of the prescriptive <br />requirements, the installation must be in accordance <br />with 2006 IRC Section R301.2.1.1. <br />8.5 Conditions Of Use: <br />See Section 5,0, except that (Section 5.7) a fire separation <br />distance of greater than 5 feet must be in accordance with <br />2006 iBC Section 704.5. <br />ESR 1066 ` Most Widely Accepted and Trusted <br />m.__..: _..... ., <br />TABLE 1-VINYL SIDING AND SOFFIT <br />PRODUCT <br />NAME <br />PRODUCT <br />CODE <br />PRODUCT <br />STYLE <br />�THICKNESS <br />h) <br />LENGTH <br />(feet -inches) <br />The following products are sold under the brand name CertainTeed <br />Monogram46 <br />33101 <br />33110 <br />33111 <br />33122 <br />33103 <br />33125 <br />Double 4-inch <br />Double 4-inch <br />Double 4-inch <br />Double 5-inch <br />Double 5-inch DutchLap <br />Double 5-inch Dutchlap <br />0-046 <br />0.046 <br />0.046 <br />0_046 <br />0.046 <br />0,046 <br />12-6 <br />12-6 <br />12-6 <br />12-0 <br />12-0 <br />12-0 <br />Monogram 46L <br />33114 <br />33139 <br />33126 <br />33140 <br />Double 4-inch <br />Double 4-inch <br />Double 5-inch DutchLap <br />Double 5-'inch DutchLap <br />0.046 <br />0 046 <br />0-046 <br />0.046 <br />16-8 <br />20 0 <br />16-0 <br />20-0 <br />Classic <br />36110 <br />36119 <br />36122 <br />Double 4-inch <br />Double 4'/24nch DutchLap <br />Double 5-inch <br />0.044 <br />0.044 <br />0.044 <br />12-6 <br />12-1 <br />12-0 <br />Mainstreet <br />39131 <br />39111 <br />39110 <br />39122 <br />39113 <br />39125 <br />Triple 3-inch <br />Double 4-inch <br />Double 4-inch <br />Double 5-inch <br />Double 4-inch DutchLap <br />Double 5-inch DutchLap <br />0.042 <br />0.042 <br />0.042 <br />0.042 <br />0.042 <br />0.042 <br />12-1 <br />12-6 <br />12-6 <br />12-0 <br />12-6 <br />12-0 <br />39104 <br />Single 84nch <br />0.042 <br />12-6 <br />39102 <br />6'/2-inch Beaded <br />0.042 <br />12-4 <br />Board & Batten <br />34137 <br />Single 8 Vertical <br />0.048 <br />12-6 <br />Carolina Beaded <br />34138 <br />38102 <br />Single 8 Vertical <br />6'/.-inch Beaded <br />0.048 <br />0.044 <br />10-0 <br />12-4 <br />60106 <br />Single 7-inch <br />0-050 <br />10-1 <br />Northwoods <br />60107 <br />Single 10-inch Shake <br />0-050 <br />10-0 <br />60148 Single 94nch Shake <br />The fnllnwir r-4, t. __ __jA <br />0.050 <br />10-4 <br />Restoration Smooth <br />36132 <br />Triple 34nch <br />Double 4'1zinch <br />0.044 <br />0.044 <br />12-136118 <br />12-1 <br />Classic <br />36110 <br />36119 <br />36122 <br />Double 4 inch <br />Double 41/2-inch DutchLap <br />Double 54rich <br />0.044 <br />0.044 <br />0.044 <br />12-6 <br />12-1 <br />12-0 <br />American Legend <br />Encore <br />40131 <br />40110 <br />40111 <br />40122 <br />40119 <br />40102 <br />40105 <br />43130 <br />43110 <br />43122 <br />Triple 7inch <br />Double 44neh <br />Double 4-inch <br />Double 5-inch <br />Double 4'/2-inch DutchLap <br />6'1z4nch Beaded <br />Single 8-inch <br />Triple 34nch <br />Double 4-inch 1 <br />Double 54mh <br />0.042 <br />0.042 <br />0.042 <br />0.042 <br />0.042 <br />0.042 <br />0.042 <br />0.040 <br />0.040 <br />Q 040 <br />12-1 <br />12-6 <br />12-6 <br />12-0 <br />12-1 <br />12-4 <br />12-6 <br />12-1 <br />12-6 <br />12-0 <br />43119 <br />61110 <br />Double 4'/2-inch DutchLap <br />Double 4-inch <br />0.040 <br />0.040 <br />12-1 <br />12-6 <br />Newtown <br />61122 <br />Double 5-inch <br />0,040 <br />12-6 <br />61125 <br />Double 5-inch DutchLap <br />0-040 <br />12-6 <br />ESR-1066 ` Most Widely Accepted and Trusted <br />TABLE 1-VINYL SIDING AND SOFFIT (Continued) <br />Page 5 of 6 <br />PRODUCT <br />NAME <br />PRODUCT <br />CODE <br />PRODUCT <br />STYLE <br />THICKNESS <br />(inch) <br />LENGTH <br />(feet -inches) <br />The following products are sold under the brand name Vytec <br />Nantucket <br />Double 44nch <br />.040 <br />12-3 <br />Double 4-inch Dutchlap <br />.040 <br />12-3. <br />Double 4'IL4nch Dutchlap <br />.040 <br />12-11 - <br />Beaded <br />Single 6'/24nch <br />.048 <br />12-4 <br />Proside <br />Double 44nch <br />.042 <br />12-3 <br />Double 4'Irinch <br />.042 <br />12-11 <br />Double 4'/2-inch Dutchlap <br />.042 <br />12-3 <br />Single 8-inch <br />.042 <br />12-3 <br />Triple 3 <br />Triple 3-inch <br />,042 <br />12-11 <br />Prestige <br />Double 41/24nch <br />.044 <br />12-11 <br />Double 4'/24nch Dutchlap <br />.044 <br />12-11 <br />Double 54rr-h Dutchlap <br />.044 <br />12-11 <br />Eminence <br />Double 4'lz-inch <br />.046 <br />13-4 <br />Double 4'/z4nch <br />.046 <br />20-0 <br />Double 41/2-inch Dutchlap <br />.046 <br />13-4 <br />Double 41/2-inch Dutchlap <br />046 <br />20.0 <br />Board and Batten <br />Single 6'/2 <br />76E0 <br />10-0 <br />The following products are sold under the brand name Vinyl Carpentry: <br />Triple 31/3-inch <br />InvisVent Soffit <br />46228 <br />Triple 3'/ <br />P 3-inch Vented Soffit <br />0.044 <br />12-6 <br />Triple 3' enrich <br />Soffit /Verticala <br />46229 <br />Triple 3'/ -inch Soffit i Vertical Sidi rig <br />0.044 <br />12-6 <br />IronMax Soffit/ Vertical <br />47201 <br />Double 5-inch Solid Soffit/ Vertical <br />Siding <br />0.046 <br />12-0 <br />47205 <br />Double 5-inch Fully Vented <br />0.046 <br />12-0 <br />Universal Soffit/ Vertical <br />48224 <br />Triple 44nch Fully Vented <br />0.040 <br />12-0 <br />48216 <br />Triple 44nch Solid Soffit/ Vertical <br />Siding <br />0.040 <br />12-0 <br />48220 <br />Triple 4-inch Center Vented <br />0.040 <br />12-0 <br />Beaded Soffit/ Vertical <br />46209 <br />Triple 2-inch Solid Soffit/ Vertical <br />Siding <br />0.039 <br />12-6 <br />46211 <br />Triple 2-inch Vented <br />0.039 <br />12-6 <br />Value Soffit <br />49224 <br />Triple 44nch Fully Vented <br />0.036 <br />12-0 <br />49216 <br />Triple 4-inch Solid Soffit <br />0.036 <br />12-0 <br />49220 <br />Triple 4-inch Center Vented <br />0.036 <br />12-0 <br />ESR-1066 ' Most Widely Accepted and Trusted Page 6 of 6 <br />TABLE 2-ALLOWABLE NEGATIVE WIND LOADS <br />SIDING <br />MAXIMUM STUD' <br />SPACING (inches) <br />FASTENER' <br />ALLOWABLE NEGATIVE <br />WIND LOAD (psf) <br />SBC <br />BNBC <br />IBC/IRC <br />UBC <br />Monogram 46 D5 <br />16 <br />Nail to studs <br />53 <br />53 <br />53 <br />33 <br />16 <br />Staple to studs <br />47 <br />47 <br />47 <br />29 <br />Monogram 46 D5DL <br />16 <br />Nail to studs <br />76 <br />76 <br />76 <br />47 <br />16 <br />Staple to studs <br />49 <br />49 <br />49 <br />31 <br />24 <br />Nail to studs <br />44 <br />44 <br />44 <br />28 <br />Monogram 46 D4 <br />16 <br />Nair to studs <br />91 <br />91 <br />91 <br />57 <br />16 <br />Staple to studs <br />58 <br />58 <br />58 <br />36 <br />Monogram 46L D4 <br />16 <br />Nail to studs <br />87 <br />87 <br />87 <br />54 <br />Monogram 46L D5DL <br />16 <br />Nail to studs <br />78 <br />78 <br />78 <br />49 <br />Classic D5 <br />16 <br />Nail to studs <br />67 <br />67 <br />67 <br />42 <br />16 <br />Staple to studs <br />36 <br />36 <br />36 <br />22 <br />24 <br />Nail to studs <br />49 <br />49 <br />49 <br />31 <br />Classic D4 <br />16 <br />Nail to studs <br />80 <br />80 <br />80 <br />50 <br />Mainstreet D5 <br />16 <br />Nail to studs <br />76 <br />76 <br />76 <br />47 <br />16 <br />Staple to studs <br />38 <br />38 <br />38 <br />24 <br />24 <br />Nail to studs <br />47 <br />47 <br />47 <br />29 <br />Mainstreet D5DL <br />16 <br />Nail to studs <br />62 <br />62 <br />62 <br />39 <br />16 <br />Staple to studs <br />58 <br />58 <br />58 <br />36 <br />24 <br />Nail to studs <br />42 <br />42 <br />42 <br />26 <br />24 <br />Staple to studs <br />36 <br />36 <br />36 <br />22 <br />Mainstreet D4 <br />16 <br />Nail to studs <br />53 <br />53 <br />53 <br />33 <br />16 <br />Staple to studs <br />82 <br />82 <br />82 <br />51 <br />Carolina Beaded <br />16 <br />Nail to studs <br />67 <br />67 <br />67 <br />42 <br />16 <br />Staple to studs <br />56 <br />56 <br />56 <br />35 <br />24 <br />Nail t° studs <br />36 <br />36 <br />36 <br />22 <br />24 <br />Staple to studs <br />38 <br />38 <br />38 <br />24 <br />Northwoods S7 <br />Northwoods S10 <br />16 <br />16 <br />Nail to studs <br />Nail to studs <br />60 <br />42 <br />60 <br />42 <br />60 <br />42 <br />38 <br />26 <br />Northwoods S9 <br />16 <br />Nail to studs <br />42 <br />42 <br />42 <br />26 <br />Board & Batten <br />12 <br />Nail to sheathing <br />62 <br />62 <br />62 <br />39 <br />American Legend D5 <br />16 <br />Nail to studs <br />36 <br />36 <br />36 1 <br />22 <br />16 <br />Staple to studs <br />33 <br />33 <br />33 <br />21 <br />American Legend D4 <br />16 <br />Nail to studs <br />60 <br />60 <br />60 <br />38 <br />16 <br />Staple to studs <br />58 <br />58 <br />58 <br />36 <br />Encore D5 <br />16 <br />Nail to studs <br />44 <br />44 <br />44 <br />28 <br />16 <br />Staple to studs <br />69 <br />69 <br />69 <br />43 <br />24 <br />Nail to studs <br />33 <br />33 <br />33 <br />21 <br />24 <br />Staple to studs <br />44 <br />44 <br />44 <br />28 <br />Encore D4 <br />16 <br />Nail to studs <br />64 <br />64 <br />64 <br />40 <br />16 <br />Staple to studs <br />53 <br />53 <br />53 <br />33 <br />Newtown D4 <br />16 <br />Nail to studs <br />51 <br />51 <br />51 <br />32 <br />Newtown D5 <br />16 <br />Nail to studs <br />38 <br />38 <br />38 <br />24 <br />Newtown D5DL <br />Triple 3-1/3 Soffit / Vertical <br />For Slt 1 inrh = 95 d mm 1 .,mot - <br />16 <br />12 <br />n nA7n t.n_ <br />Nail to studs <br />Nail to sheathing <br />22 <br />56 <br />22 <br />22 <br />14 <br />56 <br />56 <br />35 <br />2Studs are minimum 2-by-4 wood with a minimum specific gravity of 0.42. <br />Nails and staples must be as specified in Section 4.4. <br />m <br />U Z In <br />Z - m <br />`uJ Q <br />0 O. <br />O <br />ZCIO -__ 00 <br />Ul 0 LLN - <br />J _N <br />� ' :5 y.t0 <br />a <br />t <br />_ (D to <br />...� W in 0 �_q O fq <br />L" <br />0 0- <br />.. Q U 7- <br />m <br />N <br />Q �m <br />inn <br />X TN <br />o �m <br />ut <br />utnt FU u <br />mIL <br />o <br />air■awao■rA■ri�n■ <br />-1 <br />4 <br />II I „il�� :I161IIMI I -T- <br />