My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6272 Abbott Station Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6272 Abbott Station Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 12:33:11 AM
Creation date
2/18/2025 3:33:33 PM
Metadata
Fields
Template:
Building Plans
Street #
6272
Location
Abbott Station Dr
Contractor
Village Square Builders
Building Plans - Permit #
12813-12816
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19 IT I Pllfi11 1 _1 _ L__a.I_._��...I _..I �I_—_IIlI T.LF "if", ff"mI I, <br />ENGINEER'S NOTES <br />1. ALL WORK TO BE DONE ACCORDING TO FLORIDA BUILDING CODES. <br />2. ASSUMED SOIL BEARING CAPACITY TO BE 2500 PSF. SOIL CAPACITY TO BE VERIFIED <br />BY CONTRACTOR PRIOR TO CONSTRUCTION. INFORM ENGINEER OF VARIATIONS. <br />FOOTINGS TO BE EXCAVATED TO CLEAN SOIL, FREE OF VEGETATION AND <br />DELETERIOUS MATTER. CONCRETE SHALL BE PLACED ON AN UNDISTURBED BASE. <br />3. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION <br />PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING AND <br />ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES, BUT IS NOT <br />LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS, OR <br />TIE DOWNS THAT MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED <br />AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER COMPLETION <br />OF THE PROJECT. <br />4. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS SHALL <br />BE VERIFIED AND SHALL CONFORM TO THE ARCHITECTURAL DRAWINGS. <br />5. CONCRETE : <br />MINIMUM COMPRESSIVE CONCRETE STRENGTH TO BE 3000 PSI IN 28 DAYS. ALL <br />CONCRETE SHALL BE "READY MIXED" AND IN ACCORDANCE WITH A.S.T.M. <br />SPECIFICATION C-94. ALL CONCRETE MODULAR UNITS SHALL HAVE A <br />COMPRESSIVE STRENGTH OF 1900 PSI WITH TYPE M OR S MORTAR, 2000 PSI. <br />6. SLAB ON FILL : <br />INTERIOR CONCRETE SLABS POURED ON FILL TO BE POURED OVER WATERPROOF <br />MEMBRANES. ALL SLABS TO BE REINFORCED WITH 6X6 10/10 WELDED WIRE MESH. <br />7. LUMBER : <br />1. STORE LUMBER OFF GROUND. KEEP WELL VENTILATED AND COVERED. <br />2. CURRENT EDITION, ASSOCIATION GRADING RULES GOVERN. <br />3. ALL LUMBER SHALL BEAR GRADE MARK OF AN ASIC BOARD OF REVIEW AGENCY. <br />4. ANY SPECIES ALLOWED UNLESS OTHERWISE NOTED. <br />5. SIZES ARE NOMINAL. ACTUAL SIZES SHALL CONFORM TO AMERICAN <br />LUMBER STANDARD PS 20-70. <br />6. MOISTURE CONTENT OF LUMBER 2" OR LESS IN THICKNESS SHALL BE <br />19% OR LESS AT THE TIME OF INSTALLATION. <br />STRUCTURAL LUMBER TO HAVE 1120 PSI FIBER STRESS IN CONFORMANCE TO <br />AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) SPECIFICATIONS. ALL <br />LUMBER AGAINST MASONRY OR CONCRETE TO BE PRESSURE TREATED. <br />8. TERMITE TREATING : <br />SOIL BELOW STRUCTURE TO BE TERMITE TREATED TO A DISTANCE OF 5'-0" <br />BEYOND THE PERIMETER LINES OF THE BUILDING. <br />9. ALL STEEL SHALL BE 40 KSI WITH A MINIMUM CLEAR COVER OF 3" AGAINST <br />SOIL, AND SHALL HAVE A MINIMUM LAP OF 40 TIMES THE DIAMETER OF THE REBAR. <br />10. 2"X12" HEADERS SHALL BE 2-2"X12" LAMINATED W/ 1/2" PLYWOOD <br />GLUED W/ CONSTRUCTION ADHESIVE AND NAILED W/ 5—#16D COMMONS 16" O.C. <br />11. ALL FASTENERS SHALL COMPLY WITH THE DESIGN LOADS. <br />12. CONTRACTOR SHALL HAVE MANUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE <br />AT THE TIME OF INSPECTION, FOR REVIEW BY THE BUILDING INSPECTOR, <br />TO MEET LOADS AS INDICATED. <br />FOUNDATION NOTES <br />1. THIS FOUNDATION PLAN WAS DESIGNED BASED UPON AN ALLOWABLE SOIL <br />BEARING CAPACITY OF 2500 PSF (MIN.) CONTRACTOR MUST VERIFY <br />AND COORDINATE ALL SITE WORK TO MAINTAIN MINIMUM SOIL COMPACTION <br />REQUIREMENTS. <br />2. ALL BUILDINGS ARE REQUIRED TO HAVE A PRE —CONSTRUCTION TERMITE <br />TREATMENT. <br />3. FOUNDATION SHALL CONSIST OF AN 12"X24" CONT. CONCRETE FOOTING <br />WITH (3) #5 REBARS ON ROD CHAIRS, SPACED NO MORE THAN 48 O.C. <br />FILLED CELLS WILL BE VERT. #5 RODS IN ALL CORNERS AND BESIDE <br />EACH MASONRY OPENING. THE MAX. SPACING FOR ANY FILLED CELL <br />WILL BE 6'-0" O.C. ALL RODS MUST BE BENT AND TIED TOGETHER <br />WITH A MIN. LAP OF 25". SEE WALL SECTIONS. <br />I <br />m <br />0 <br />I <br />0 <br />IVIIJIVVLI 1 fill+ l,V1 V l,. rlJ l/I II NI l7 W/2 #5 <br />REBARS CONT. SPACED 6" O.C. ON 3" <br />HIGH CHAIRS <br />8" CONCRETE BLOCK WALL - TYP <br />1" DOW BLUEBOARD INSUL. OVER J" P.T. FIRRING <br />STRIPS (POLYFILM OVER FIRRING), FINISHED W/}" <br />GYPSUM BOARD <br />STUCCO FINISH <br />WOOD BASEBOARD - TYP. <br />4" 3000 PSI CONCRETE SLAB WITH 6"X6" <br />#10/10 WWM OVER 6 MIL. POLY VAPOR BARRIER <br />OVER CLEAN COMPACTED, TERMITE TREATED SOIL. <br />FINISHED GRADE TO BE FIELD DETERMINED <br />SLOPE TO DRAIN _ <br />12"X24" FOOTING WITH (3) #5 <br />REBAR CONT. ON 3" HIGH CHAIRS <br />2 MONOLITHIC FOOTING 3 <br />B 3 SCALE: 1 /2"=1 '-0" B 3 <br />#5 VERT. REINFORCEMENT IN CONT. FILLED CELL, OVERLAPPING #5 <br />STD. HOOKED FOOTING DOWEL 25" MIN. <br />#5 STD. DOWEL W/6" HOOK INTO FOOTING <br />% , � 1. , .. � . .. <br />24" <br />TYPICAL FOOTING DETAIL <br />SCALE: 1 /2"=1 '-0" <br />60'-0" <br />26'-0" 8'-o" 26'-0" , <br />s'-4» <br />H.B. <br />r------------------------------------------------- <br />-------- ----- <br />j <br />■ <br />■ ■ 10 WINDOW ■ <br />■ <br />o <br />------------ ------------- -- <br />----- <br />---- ----------tr-------� <br />AHU IL 4... UL-------- <br />I <br />�-----------------J I I <br />I \ <br />INSTALL DRAIN LINES <br />■ <br />I -= I FOR AHU & WATER HTR. I <br />io <br />11p1 <br />IO <br />1 1 <br />I <br />N <br />7'-10" <br />II ------------------------------------------------------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />+----------' I I <br />I I `� I ,� I■ I 4" CONCRETE I <br />SLAB WITH 12" <br />DEEP MONOLITHIC <br />I ' I FOOTING, <br />BREEZEWAY ONLY <br />I■ I I ,/ I I I <br />01 <br />F.F. ELEV. —4.0" <br />I I I ,' 1■ I I <br />■ i i F'� i i BREEZEWAY <br />CONCRETE j <br />A:, <br />_ I <br />I li I <br />�O' 1 <br />olI <br />I of I I <br />z l <br />I I <br />I � I <br />I I <br />-------F <br />I I <br />I I r-------- r <br />I I II I <br />I I II I <br />I I II I <br />I L-------I <br />I <br />I I ii I <br />3 i <br />i i 1■ <br />I I <br />OFFICE A i-------� <br />i i r------- <br />I I I--------P <br />B3 <br />I <br />I <br />I I <br />I <br />I <br />I I <br />I <br />I F. F. ELEV. 0.0 <br />I I <br />I I L------- I <br />I 1 1 r <br />I <br />I <br />I I I <br />I <br />I I I I <br />I 1 F--------r <br />I I <br />I■ <br />I <br />I <br />I 1 <br />I I 1 <br />I I 1 <br />1 I 1 <br />I I <br />I Lr-------F <br />I I <br />I I <br />#5 VERT REBAR IN GROUT FILLED CELL, <br />I <br />I <br />I <br />I I I <br />I <br />I I <br />I I <br />CONT. TO BOND BEAM, ® GIRDER <br />I <br />1 I I <br />I I <br />TRUSS ABOVE, SEE 2ND. FLOOR <br />I <br />FRAMING PLAN <br />I <br />1 I I <br />I <br />I <br />I I <br />I <br />I <br />1 1 <br />1 I 1 <br />i ^r^12"X24"TFOOTING WITH (3) #5 <br />I I <br />ALL EXTERIOR <br />DIMENSIONS ARE TO <br />OUTSIDE FACE OF <br />MASONRY, U.N.O. <br />`r UI\mI IV Ill JL1'YLI\ <br />J, <br />� 1 <br />1 1 <br />■ ■1 WINDOW- 1 ■ ■ ■ ■ <br />- +---- --------------------------------------1 <br />- -- -------i 1 I <br />R --_ _ <br />AHU UU <br />■---�-- <br />jI I <br />' I i <br />o <br />I I <br />p <br />z <br />jail <br />0 <br />l i <br />� <br />1O1 <br />jpi <br />1 <br />l \ I <br />■ <br />I � I <br />I \ I <br />I \ I <br />I \\ I <br />I <br />I \ I <br />I \ I <br />I \ I <br />I <br />I ` I <br />I <br />I \ I <br />I \ I <br />I \ I <br />\ I <br />I \ I <br />I \ I <br />I <br />�ooi <br />I I�0 <br />I I Ilzi <br />I II <br />1 <br />I I <br />I <br />I <br />■ <br />■ <br />I I <br />I <br />; FUTURE I <br />I <br />I <br />OFFICE B <br />a <br />oF.F. ELEV. 0.0 i i <br />■ <br />I I <br />I <br />I m I I <br />I I I <br />I I I <br />■ <br />I I I <br />I <br />I I <br />I I I <br />I I I <br />I I I <br />I � I <br />1 FOUNDATION PLAN <br />PB 3 SCALE: 1 /4"=1 '-0" <br />T UINM 11 1\l JLTYLI\ <br />I <br />I <br />I <br />I <br />I <br />J, <br />1 <br />■ DENOTES #5 VERT. REINFORCEMENT IN GROUT <br />FILLED CELLS AT 6'-0" O.C., OVERLAP STD. <br />HOOKED FOOTING DOWELS 25" MIN. <br />H.B. <br />DENOTES HOSEBIB LOCATIONS <br />I <br />I <br />I <br />I <br />I <br />I , <br />I � <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />II <br />I <br />#5 VERT REBAR IN GROUT FILLED CELL, <br />CONT. TO BOND BEAM, ® GIRDER TRUSS <br />ABOVE, SEE 2ND. FLOOR FRAMING PLAN <br />F--1 <br />H co <br />C9 <br />w co <br />cn <br />�aX <br />. � C) <br />W <br />�+ N a <br />� a <br />w <br />cv <br />:2 vi <br />-O <br />LL v <br />� a <br />c o <br />c) U) <br />Qaaio <br />Ln N N <br />L <br />L <br />j Lm .— <br />C c <br />> -p O <br />� o <br />En <br />CIO <br />c o <br />ca N x ao <br />,�' •Q ai c� <br />0 0 U cn <br />.� c w <br />O � . <br />L p m E'I <br />W cV <br />(D Q co <br />co <br />0 J <br />J > U_ <br />m Y J <br />0 O = <br />EL IIY � <br />L.L W <br />O _j w <br />Cn IV <br />t— <br />tn U) <br />Of <br />W W <br />Z <br />coQO <br />O Q M <br />Q � � <br />C�1 M <br />Z U) T--- <br />O W °O <br />U (, <br />J Q <br />J <br />J <br />W <br />Z <br />W <br />0 <br />REVISIONS: <br />Issue Date: <br />11/11/11 <br />FOUNDATION PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.