My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6366 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6366 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:54:36 AM
Creation date
2/18/2025 3:33:41 PM
Metadata
Fields
Template:
Building Plans
Street #
6366
Location
Bar S Bar Trl
Contractor
Lennar Homes LLC
Building Plans - Permit #
4648
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIN <br />CONT. HANDRAIL <br />RETURN TO. <br />� WALL DETAIL. <br />A SCALE: NTS <br />STAIR CALCULATIONS: <br />TOTAL R I S E = 10'-0 3/4" <br />(16) RISERS AT 7 -9/1611 <br />10 TREADS w/ 3/4 NOSING <br />42" KNEE WALL WITH <br />1x8 CAP & CASING <br />USP MP3 CLIP EA. <br />STRINGER TO BEAM/ <br />FLOOR SYSTEM TYP. <br />16 <br />36" H. CONT. 15 <br />GRASPABLE _ ' 14 <br />RAILING /' %13 <br />CY) <br />l 12 <br />I ' <br />I .10 <br />10 <br />" 11 <br />I/ <br />42" KNEE �ICD i 10 <br />WALL WITH 9 1x TREAD <br />1x8 CAP & C.p I o;�� (TYP.) <br />CASING I 8 STORAGE <br />7 UNDER <br />I � <br />A ,-' 6 STAIRS <br />I <br />1x8 CAP & /5 2x FRAMED <br />CASING I,% 4 WALL <br />1x RISERS <br />3 (TYP.) <br />0 <br />MI'� <br />IN <br />2 (3) 2x12 2x FRAMED <br />STRINGERS <br />2x4 #2 SYP. P.T. THRUST BLOCK <br />W/(2)- 1/4"x 3 1/2" TAPCONS @ <br />161111o.c. AND 3" FROM EA. END. <br />TYP. STAIR SECTION <br />� SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDINC <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1, <br />STRINGERS w/ <br />SIMPSON A35/USP <br />MP34 CLIP TO <br />FLOOR SYSTEM OI <br />LANDING FRAMINC <br />(2) 2x HDR. <br />REQ'D @ ENC <br />LANDING FOF <br />STRINGERS 1 <br />CONNECT TC <br />SCALE: 1/2" = V-0" <br />WALL <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />GENERAL LANDING FRAMING INFO. - <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />2x4 #2 SPF STUDS @ 16" <br />O.C. TYP. @ 2nd FLOOR <br />3/4" PLYWOOD EXTERIOR WALLS <br />DECKING <br />FLOOR SYSTEM <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />J <br />S6 <br />TYP. <br />U.N.O. <br />H1 <br />6 <br />B D2 <br />25 SH <br />*EGRESS <br />I <br />OWNER <br />SUITE <br />8'-0" FLAT CLG. <br />CARPET <br />ao - - G.T. - <br />140C <br />REV 10.1.20 CAB <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />2x6 <br />SYP #2 <br />16" O.C. <br />WHEN THE TOP OF WALL IS GREATER THAN 9'-0", THEN AT <br />EACH EXTERIOR CORNER WITHIN THE 4'-0" END ZONE, THE <br />STUDS WILL BE DOUBLE STUDS @ 16" O.C. OR SINGLE STUDS <br />@ 12" O.C.' <br />THIS IS ONLY USED WITH PLASTER OR STUCCO EXTERIOR <br />FINISH <br />'• WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT. <br />REFER TO SHEATHING SCHEDULE FOR ATTACHMENTS- <br />r--------------------� <br />25'-0" 1 I <br />I I <br />I H1 <br />61 I <br />A D I <br />I <br />25 SH I I <br />*EGRESS 60" X 36" TB <br />SHOWER to <br />O <br />FIBERGLASS <br />SURROUND <br />TP <br />_/� <br />0.. <br />o A <br />2� 8 <br />l <br />IL o <br />IT <br />� ILEI F Ii11�► <br />6„ <br />4-SH <br />WIC I <br />8'-0" FLAT CL . <br />(4„ 206 CARPET I CQ <br />l ACCESS, o'�c <br />L 36'4 <br />- - - - - - ------� <br />R&S <br />r�� <br />s <br />s <br />O <br />BEDROOM <br />4 <br />w <br />T-3" <br />8'-0" FLAT CLG. <br />7. <br />CARPET <br />;n <br />0 <br />T-6' <br />8.- -F�T CLG. <br />TB <br />u)10 <br />1/2 WALL OR <br />- <br />W <br />RAILING PER SPECS <br />N <br />W <br />TECH CENTER <br />k)2 <br />11' 4" 2668 <br />5'-11" <br />7'-9" <br />2668 <br />& <br />A <br />BF <br />=_--- <br />_ _ <br />-___� <br />H1 <br />O <br />in <br />l <br />I <br />DN 16 <br />10' 10' <br />Cal <br />�� <br />Ty; <br />5068 BFj I <br />itI <br />----- <br />4 5 6 7 8 <br />-- <br />9 10 11 1213 <br />------_� <br />----------- <br />14 5 6 <br />W I <br />LAUD I <br />R&S <br />2652 <br />8'-0" FLAT C G. <br />TILE <br />------ <br />-- <br />5'-11" <br />3'-10" - 3'-11" <br />o <br />04 <br />D I <br />H <br />4068 <br />BF <br />N <br />9,_51" <br />3 '\ r <br />D2 <br />SIM. W/ (1) I <br />MSTAM36 G.T. 1 5068 <br />STRAPS @ - - BASE 11'-z" - - 2' <br />F (ni � <br />BEDROOM 2 �, BEDROOM 3 <br />8'-0" FLAT CLG. I 8 -0' FLAT CLG. <br />CARPET I CARPET <br />I *EGRESS *EGRESS <br />2 SH 25 SH I <br />OH1 9 © 39 22 D2 (1) I <br />D2 D1 D1 I <br />JAMB STUD OVER I H1 I <br />ENTRY TO BE I I <br />CONNECTED DOWN I I <br />PER DETAIL 6/D2 L------------- <br />-4" <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) -1 3/4" X 91/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />" VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />" SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />1 TYP. @ <br />)2 CORNERS <br />r D2 H1 <br />O <br />Ev <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />TUB/ SHWR <br />TILE TO 7' <br />A.F.F. <br />i" <br />v <br />D2 <br />O <br />-HANSON BOX <br />@ 36" A.F.F. <br />J <br />J <br />co <br />N <br />-DRYER VENT <br />THRU SIDE <br />WALL <br />-WIRE SHELF <br />@ +54" A.F.F. <br />TYP. <br />U.N.O. <br />3 <br />D2 <br />SIM. W/ (1) <br />MSTAM36 <br />STRAPS @ <br />BASE <br />4 <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />0 <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 / -29.1 <br />OF <br />+26.6 / -33.5 <br />GO <br />SEE SN SHEET O SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX25 <br />S.H. <br />13 <br />20 X 38 3 <br />181 X 37 4 <br />S.H. <br />14 <br />20 X 50 5 <br />181 X 50 <br />S.H. <br />15 <br />20X63 <br />182'X622 <br />S.H. <br />16 <br />20X72 <br />182X71} <br />S.H. <br />11-12 <br />27 1/4 X 26 <br />26 X 251 <br />S.H. <br />1H3 <br />27 1/4 X 38 4 <br />26 x 371 <br />S.H. <br />1 H4 <br />27 4 X 50 1 <br />26 x 50 <br />S.H. <br />1 H5 <br />27 i X 63 <br />26 X 62 1/2 <br />S.H. <br />1H6 <br />271 X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 4 X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 4 X 38 J <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 4 X 50 g <br />36 � X 50 <br />S.H. <br />25 <br />37 4 X 63 <br />36 1 X 62 1/2 <br />S.H. <br />26 <br />37 4 X 72 <br />36 4 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 2 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 J X 25 > <br />S.H. <br />33 <br />54 X 381 <br />52 J X 37 4 <br />S.H. <br />34 <br />54 X 501 <br />521 X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 J <br />S.H. <br />36 <br />54 X 72 <br />52 21 X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />LS.H. <br />Stair and Railing General Notes <br />Stairway construction shall conform to the FBC Residential 7th Edition (2020) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than <br />9/16 inch or a bevel not exceeding '/s inch. A nosing projection not less than 3/4 inch and not more than 11/4 <br />inches shall be provided on stairways. The greatest nosing projection shall not exceed the smallest nosing <br />projection by more than 3/8 inch within a stairway. <br />Handralls: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be provided for those portions of open -sided walking surfaces, including stairs, ramps and landings, <br />that are located more than 30 inches measured vertically to the floor or grade below at any point within 24 inches <br />horizontally to the edge of the open side. Required guards at open -sided walking surfaces, including stairs, <br />porches, balconies or landings, shall be not less than 36 inches in height as measured vertically above the <br />adjacent walking surface or the line connecting the leading edges of the treads. Required guards shall not have <br />openings from the walking surface to the required guard height that allow passage of a sphere 4 inches in <br />diameter. <br />Under -stair protection: <br />Enclosed space under stairs that is accessed by a door or access panel shall have walls, under -stair surface and <br />any soffits protected on the enclosed side with 1/2-inch gypsum board. <br />SECOND FLOOR PLAN - ELEV-B. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classl duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M 1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic, crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST LIVING 728 S.F. <br />SECOND LIVING 1036 S.F. <br />TOTAL LIVING 1764 S.F. <br />LANAI 60 S.F. <br />GARAGE 379 S.F. <br />ENTRY 62 S.F. <br />TOTAL SQ. FT. 2265 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-19 KRAFT FACED <br />CONDITIONED CEILING R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />N <br />N 0 <br />a, <br />CL U N <br />co <br />•- <br />M U <br />r <br />C) L <br />N L <br />v � N Y <br />N N (!) <br />N -a s cr <br />C) 5 to <br />U ti <br />U (v <br />C1✓ f_L' �. <br />c <br />s u• O O <br />a [_ U 1 <br />3 .O -L5 <br />R _ 11-1 <br />IN'tiv tl1P/17/��'�� <br />..���`�\d\1;li <br />.ti, F3RQ N o <br />Ci <br />fill 11I111111�`�1�ti <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residenbal <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />H o EII c n <br />Q N N 8 cnp <br />cNp <br />i� y CDC �_J , <br />O S uu-w <br />0- <br />W cor,�- LL w <br />Y <br />y M < 0.co <br />LL LL 0. <br />W <br />00 <br />0° <br />O J <br />WZ �p <br />Z ZaixhoLLV QN� <br />W ooa <br />z <br />z� <br />zU) <br />o <br />a v <br />-1 <br />- N <br />z <br />�tit <br />-J <br />f13 w <br />OW <br />U � <br />0 <br />Q 0 <br />0c <br />N <br />� <br />w <br />Z <br />_J <br />" E <br />a� <br />Ir <br />zo <br />s <br />Z <br />g E <br />xU <br />azZ <br />N <br />t <br />a0 <br />e� <br />�& <br />I <br />c <br />co C: <br />U <br />NO <br />QL <br />Z <br />aL <br />30 <br />U <br />k <br />W <br />?� <br />w� <br />0 <br />°O <br />= <br />�U-) <br />0 <br />m <br />O <br />CO <br />N <br />CT <br />U) m <br />Q0 <br />~ <br />O <br />� <br />C00 D <br />N <br />C) <br />o <br />Ln <br />Q N <br />r <br />ai <br />w <br />N <br />00 <br />H N <br />o <br />Z <br />Z <br />E N <br />o <br />ra <br />a <br />U _J¢ p <br />� <br />JOB <br />NO: 22-02374 <br />SCALE : AS NOTED <br />SHEET NO. <br />1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.