r�l■Y■Yul■u �I�l>�.YhVJi.V Ii1��9111�W�li��illi.:,,�.�il�;�►�:.. 7.;�....; <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES. - <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed Within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />L <br />DUPLEX CONVENIENCE OUTLET <br />PqT <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />$4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q <br />EXHAUSTFAN <br />;O <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />wl <br />ELECTRIC PANEL <br />_—MLL <br />DISCONNECT SWITCH <br />Q,�� <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />15OA1200A INDOOR <br />PANEL CENTER <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />n <br />200 amp <br />150 amp <br />#14 copper to lights & outlets <br />112 copper to 20 amp ckts <br />R10-2 copper to WH <br />s10-3 copper to Oryer <br />or 4/0 SER Alu <br />UNDERGROUND Discot <br />POWER CO. FEED <br />INTERSYSTEM Bare Cu Ground <br />BONDING UNDING WIRE <br />TERMINATION PER WITH CODE APPROVE <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />II ALT II <br />j I AC PAD I j <br />I� �I <br />OPT. <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />X <br />GFf N j <br />-7 <br />I i I i I <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />F- - - - - - - - - - - - - - - - - - - -- <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />1—r I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />3" <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />CENTER <br />GFI @ <br />44" A.F.F. <br />lil 3" VTR 1.5" VTR <br />I' <br />I I� <br />I I <br />I I <br />I I <br />� I I <br />K\ I I <br />III 3" VTR <br />I \ I I, <br />I I \\ I I <br />I � I <br />j I ice/ � I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN - ELEV-B <br />SCALE: %4'=1'-0" <br />O <br />O <br />co <br />N <br />•" >✓ <br />U M 0 <br />Y <br />C <br />O O Q) <br />�-+ <br />Q <br />O sue_ <br />n <br />V C C2 <br />`C-. <br />W <br />J <br />.1) <br />IVY <br />.L ! C <br />O O <br />v) W <br />chi <br />0 <br />N <br />N <br />0 <br />To the best of theEngineer's knowledge, information and belief, <br />the structural plans and spWfications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />Qo <br />00 <br />�pp*it <br />0 <br />N 0 � rp � I. <br />r °� u" w <br />w a <br />c � ��u- Q. <br />LL <br />� <br />Z <br />QM a <br />LL <br />o <br />L t0 00 <br />W�pjOi <br />' C < m O <br />d a <br />a <br />Z <br />L <br />N C0Z QQrA O <br />U U J y <br />Z <br />W <br />C1 <br />❑ ❑ ❑ <br />Z N M <br />Z <br />z o <br />a <br />-, - <br />z <br />E3 <br />M <br />M <br />.O <br />— LU <br />W <br />o <br />8 <br />N <br />�cn <br />cm�-_ Y <br />ru <br />w A <br />g <br />U <br />U � <br />• <br />co <br />t� <br />cn <br />E <br />20 <br />QO <br />ZZN <br />4 R <br />d O <br />N V <br />�z <br />> <br />Z <br />oa <br />00 <br />ID i <br />d <br />Haagp <br />�s <br />ZW <br />�_ <br />? <br />� <br />U <br />LL <br />y- <br />'FaQ` <br />124 <br />> U-) <br />M <br />0 <br />00 <br />co <br />:Cr <br />N <br />i••� <br />T <br />r <br />Cfl <br />CD <br />N <br />� <br />N <br />LO <br />T� <br />Q <br />N <br />T <br />E <br />R <br />E MM <br />W <br />N <br />H cV <br />o <br />Z <br />Z <br />m <br />E N <br />m <br />v ci <br />c <br />JOB <br />NO: <br />22-02374 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />