Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-1\2" LONG (3/4"-1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAx1-1/2" LONG (3/4%1" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF �J <br />HOME H C G <br />GARAGE SIDE 0 O O <br />5'-0" o <br />STUB -OUT FOR 0 1'-O" 0 9 <br />LO <br />GAS METER d 8 <br />04 g <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />1014" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 SIMPSON HTS20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x — <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally fWS <br />Filler blocking <br />1/8" gap <br />FILL CELL STD. 900 HOOK BOND BEAM <br />SIMPSON MGT <br />w/ (22)10d <br />w NAILS TYP. GIRDER TRUSS <br />j STD. 90° CONT. #5 <br />BAR CONT. #5 I HOOK F�� BAR 2X TOP PLATE <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION <br />@ INT. BRIG. WALL <br />N.T.S. <br />1/8" min* <br />Small ?� min. <br />2" max ) <br />gap <br />4 max. <br />Q <br />Clinch nails <br />when <br />possible I <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" Imin. <br />4) Place joists together and nail from each side with 2 rows of 10d nails required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGY8" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION <br />- Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than 15001b <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 pff max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />oversquash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />1 /1 <br />code for appropriate <br />details in <br />One 10 d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />BLOCKING PANEL, INTERIOR <br />Boise Joist Blocking Vertical load transfer =1900 plf max. along bearing wall <br />Use 3" (10d) nails at 6" o.c. Required on interior walls: - for vertical load transfer <br />Load bearing walls when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over _ <br />blocking and wall or beam below.*�7 <br />— --� <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Q�/ Provide adequate bearing Use 10dx3" nails at 6"o.c. for all joist <br />for each lapped joist. <br />blocking panel *Non -stacking walls <br />Squash block) 10dnails SECTION @INT. BRIG. WALL require additional consideration.— <br />2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />KNOCKOUTS) ALLOWED MINIMUM SPACING = 2x GREATEST <br />IN BEARING ZONES p DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />6,� A 1 2" ROUND HOLE MAY 6�. 6,� 0 NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT OUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y" <br />8 <br />11-4" <br />1'-1" <br />1' 2" <br />1' 2" <br />T -" <br />1-3" <br />V-T' <br />V-11" <br />2-4' <br />2'-t:tr' <br />32" <br />3T' <br />Arty 16" t 12 <br />T-0" <br />T-1" <br />1' 2" <br />1-2" <br />T 3" <br />T-9' <br />2'-4" <br />2"-11" <br />3' T' <br />4 2" <br />4-9' <br />6-4' <br />_ <br />S R -- 16 <br />1'47' <br />T-11" <br />1'2" <br />1, 2" <br />1' 7" <br />2-6' <br />3-7' <br />3-10" <br />4-9' <br />6 T' <br />6-4' <br />T Z" <br />20 <br />1'47' <br />1'-1" <br />1' 2" <br />1'--2" <br />zu, <br />347, <br />4'-0" <br />4-10" <br />6-11" <br />6-11" 7'11" <br />8'-11" <br />24 <br />T-U <br />1'-1" <br />1' 2,' <br />1' 3'• <br />2�' <br />3' T' <br />4'-9r' <br />5-10'" <br />T 2 <br />8' <br />9f- <br />101-9' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS, IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S. <br />Jc <br />Web Stiffener Fastener Schedule <br />Joist B ring Location <br />Series Depth End I Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />8d <br />BCI 6000s® <br />BCI 6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />1 V <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI604w <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />5/8" 9 <br />THRU <br />BOLT <br />2 X B.U.0 <br />SIMPSON MGT <br />w/(22)10d <br />NAILS TYP. <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULEFOR <br />AND QUANTITY <br />W FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />MM <br />aNINE <br />Backer block (12" wide min.) <br />Nail with 10-10d nails.in <br />stall to top flange. SLEEVE THRU STEM <br />SEE PLAN FOR •• a . • • , • <br />FOUNDATION INFO ` d' <br />STEM FOUNDATION <br />GRADE REINF. SEE PLAN <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top d <br />mount hanger load exceeds 250 lbs. a . ' L��t <br />Install tight to top flange. �� d, . <br />I II I d a I 11—I W—I <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stfter as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p T00 /depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />t: <br />(2) #5 REBAR <br />A/C CHASE 4" PVC <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />RADE <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />.. a <br />— d <br />—NA �. <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />'�— SEE FND. PLN. <br />SIZE & REINF. <br />12"BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />q d 4 <br />a e <br />co Z • ° • ' <br />d <br />SEE FND, PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />d0. <br />.a <br />G df da G <br />a d <br />� d • •a a <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />'O <br />� 0O <br />mC C\I <br />X <br />�4 MU-CL <br />Np <br />N <br />U <br />C <br />a) a) N <br />v E c <br />Z Q-C Q <br />< o ca <br />Z.3�� <br />(U <br />N <br />w ( a <br />.� <br />w <br />s <br />c>s N 0 0 <br />CU L <br />> t5 EL <br />T <br />• gyp. �4 <br />F1.04� <br />,f�','OFESSIOIIty CNN <br />r '7��l�Pftt'tt1����<x <br />To the best of the Engineers knowledge, Information and belief, <br />the stnrctural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the sinrefural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />o �E cc <br />F. <br />V <br />cc <br />j � C4 6 NC R i-R Lei. <br />L4!• <br />C 7 m S atLL W <br />0)tnnW <br />i Y <br />.44 <br />vN <br />U. <br />a W <br />WoMM0 <br />0 O <br />0 <br />Z _ <br />i <br />W cm�--, <br />§•W O <br />o <br />2Er <br />co a <br />Z N M L Z � h O <br />Z ch <br />W ❑❑❑ <br />z <br />J <br />o_ <br />z <br />(Da GDT <br />C1 <br />,tvl <br />("Cn w <br />a <br />U � cc <br />0 <br />N c= <br />�� <br />t <br />U <br />0 <br />Q N 0 <br />o <br />Mm <br />W <br />Z <br />M <br />E <br />o <br />� <br />s° <br />LL <br />a <br />�s <br />C <br />f6 <br />� <br />Z® <br />Wa <br />0 <br />�- <br />a E <br />X U <br />�` <br />�� <br />z <br />N <br />I— <br />L <br />8 <br />O <br />WW <br />L4 <br />m f <br />to <br />t_ <br />a <br />Z z <br />Z <br />°• <br />zi <br />Z <br />0�w <br />Wa <br />a= <br />2I�y <br />6 <br />�U }i <br />0 <br />� <br />� L <br />LO <br />LO <br />rn <br />m <br />co <br />W <br />L <br />� <br />C <br />O <br />v, m <br />f.-. <br />4-0 <br />+_0 <br />O <br />N <br />c <br />Lo <br />E <br />c, M <br />Z <br />l0 <br />z <br />Hl <br />E 0 co <br />E 'a <br />.. �? <br />to <br />c <br />a <br />U � ¢ p <br />JOB <br />NO: 22-02356 <br />SCALE : AS NOTED <br />SHEET NO. <br />SN 1 <br />