6381 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6381 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:47:24 AM
Creation date
2/18/2025 3:34:03 PM
Metadata
Fields
Template:
Building Plans
Street #
6381
Location
Beverly Hills Dr
Contractor
Lennar Home
Building Plans - Permit #
4148
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P <br />7 <br />) <br />) <br />) <br />I <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150At200A INDOOR <br />PANEL CENTER <br />#14 copper to lights & outlets <br />NEMA 1 #12 Copper to 20 amp ckis <br />150 AMP/ <br />200 AMP #10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />UNDERGROUND <br />sconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />Y <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />NOte& unless otherwise noted, PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Are -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSINL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />With R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />4�3 <br />THREE-WAY SWITCH <br />�?4 <br />FOUR-WAY SWITCH <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q <br />EXHAUST FAN/LIGHT COMBINATION <br />Mn <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />® <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />^_�I^ <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />DEDICATED <br />RECEPTACL <br />FOR MICRO\ <br />RANGE HOC <br />PER SPECS <br />III_ 1.5" VTR <br />'I <br />{ <br />I <br />I <br />1 I <br />� I <br /><\ I I <br />I I <br />I { I I <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />I <br />FOR DISPOSAL <br />OPTIONAL LIGHTING <br />SCALE: Y4"=1'-0" <br />S.D <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />I I LIGHT PRE -WIRE <br />BEDROOM 2 ' <br />I � I <br />I I , <br />I I I <br />L-----------{ <br />I I <br />I <br />I <br />I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />t--------------------------------------- j <br />SWITCH FOR <br />DISPOSAL IN <br />CABINET <br />If� 11 <br />I I ALT I I <br />AC PAD <br />WP <br />GFI <br />DISC. <br />�► PER SPECS / <br />ELECTRICAL PLANS - ELEV-A <br />SCALE: Y4'=1'-0" <br />:a D <br />V <br />N <br />�00X <br />a. <br />"0 O <br />M M <br />O <br />U — <br />C aN <br />) 11) <br />(13 C <br />,-� <br />� <br />< 0 M <br />^�` <br />3 .. 0 <br />2 C I� <br />3 > ._� <br />0_0 <br />m 0 00 0 <br />CU �' V <br />UJI <br />/ <br />N <br />N <br />N <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential <br />7th Edition. Engineer's signature and seal <br />is only <br />for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />� H <br />E <br />:t <br />Q O N N J <br />Ol <br />(V 1y <br />Iii ('n F r T? J W <br />QlUM a LL Q <br />SY� <br />J LL LL d W S <br />o <br />Z tm�10 <br />OC 5 1a - � o <br />W ? a <br />t°n�pjOa d <br />d <br />Z co N ;zwcn0 <br />U0m <br />LU <br />cai m 0 ML(n <br />Z p <br />Q � <br />J <br />d N <br />N <br />W <br />E <br />_ <br />GA CDU- <br />L <br />Lij <br />U <br />0 U-1 g <br />UOL <br />W <br />'® t <br />U <br />Of <br />O <br />M <br />i <br />w <br />Z <br />ML10 _j <br />o <br />g <br />LL <br />W� <br />g� <br />�dF <br />E 8 <br />U <br />0- <br />_® <br />oM <br />H <br />_C <br />aa0 <br />%V <br />o <br />0U <br />O <br />Z14 <br />O E <br />N <br />i <br />°� i <br />ao <br />W z <br />¢w <br />d <br />M <br />z <br />Mo <br />o <br />W <br />Z6� <br />J <br />`�i <br />ib <br />S <br />5 c°Z <br />W <br />10 <br />o <br />y <br />1 <br />o <br />o <br />1:2wr� <br />2I< <br />o'. <br />U <br />O <br />G <br />6 <br />Lo <br />ai <br />rn <br />c� <br />L <br />� <br />M d' <br />O <br />Q <br />C <br />w m <br />O <br />N <br />o <br />0) <br />Ln <br />cV <br />LO <br />T <br />Q N <br />T <br />ui <br />N <br />N <br />0 <br />c <br />z <br />to <br />E °: <br />m <br />c <br />a <br />U � <br />JOB <br />NO: 22-02356 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />