D8 <br />AO <br />20'-l" <br />TRUSS UPRIGHT <br />18'-10" <br />TRUSS UPRIGHT <br />THERMAL BREAK ALUM. <br />WINDOW FRAME <br />SOLID SURFACE STOOL <br />WITH 1-1/2" x 3/4" NOSE <br />WALL SECTION <br />H 1 SCALE: 3/4" = V-0" <br />TAPERED ROOF INSULATION <br />OVER 5/8" PLYWOOD DECKING <br />WRAP ROOF MEMBRANE <br />- DOWN SIDE FRAMING <br /># WRAP FRAMING IN BRAKE <br />METAL w/ DRIP EDGE <br />SIDE FRAMING / BLOCKING <br />I PER A2 / 8102 <br />............................... <br />TRUSS MEMBER PER <br />FRAMING PLAN <br />VENTED SOFFIT PANELS, FASTENED t23'-0" T/ BLOCKING <br />NV <br />TO BTM OF TRUSS @MAIN ENTRY <br />HIPARAPET <br />CANOPY SECTION <br />SCALE: 3/4" = V-0" <br />D8 <br />3 vH <br />/0' A401 <br />B5 <br />5101 <br />SHEATHING TO <br />EXTEND TO TO TI <br />OF CORNICE CAF <br />NON CORROSIVE <br />NEOPRENE WASI <br />@ 12" O.C. <br />CONTINUOUS 2xl <br />H2.5 TIE @ 32" 0.1 <br />EXTENDED CAP <br />FRAMING, TYPIC/ <br />LIGHT FIXTURE SI <br />PER ELEVATIONS <br />WRAP MEMBRANI <br />OVER TOP BLOCK <br />DOWN FACE, LINE <br />METAL FLASHING <br />EIFS BOARD @ Sl <br />TRANSITION <br />UP TO 18A 0" AFF, <br />HrrKUVHL rrvUK i U <br />FABRICATION AND DELIVERY <br />R-5 FSK BATT. INSUL. DEPTH <br />OF TRUSS VERTICAL <br />t2'-0" OVERALL, TYPICAL <br />PARAPET TOP <br />SCALE :1 1(2" = V-0" <br />18'-1" <br />T/ TRUSS UPRIGHT <br />INSTALL CLIP @ TOP & BTM <br />OF EACH PIER EDGE STUD; <br />NAIL INTO BLOCKING BTWN <br />WALL FRAMING STUDS <br />FSK FACED R5 MINIMUM < <br />BATT INSULATION TAPED <br />TO TRUSS MEMBERS AND <br />DRYWALL, TYPICAL. <br />DRAPE DOWN OVER <br />FURRING WALL AND RIGID <br />INSULATION, TYPICAL. <br />DOUBLE 2x8 TOP PLATE - <br />ANCHORED INTO C.M.U. <br />w/ 1/2" 0 HEX HEAD <br />ANCHOR w/ 5" <br />EMBEDMENT @ 24" O.C. <br />AS AN OPTION, ANCHORS <br />FOR DBL PLATES MAY BE <br />1/2" 0 THREADED ROD w/ <br />4" 1/2" EMBEDMENT w/ <br />HIL-HY70 ADHESIVE <br />TH10A CLIP @ EACH EN6, <br />TYP FOR ALL EXCEPT <br />GIRDER TRUSS; ANCHOR <br />PER TRUSS MFGR <br />SPECS. MAX UPLIFT <br />1015#S. <br />15/8" METAL FURRING — <br />STRIPS @ 16" O.C. TPE <br />@ EXT. WALLS U.N.O. <br />SEE SHEET Al03 FOR <br />WALL SUBSTRATES & <br />FIRE BLOCKING REQ'MTS <br />5/8" GYP BD INSTALL UP <br />TO TRUSS BEARING. <br />8" C.M.U., TYP @ EXT. — <br />WALLS U.N.O. <br />4" C.M.U. @ PIERS <br />1/2" CDX PLYWD OVER <br />BLOCKING w/ SPACER ON 2xl2 <br />CONT.1x6; SET TOP HIGHER THAN <br />T/ BLOCKING FOR COPING PITCH <br />CONTINUOUS 2x12 <br />FASTEN COPING OVER CONT. <br />CLEAT OVER ROOF MEMBRANE. <br />BRAKE METAL TRIM w/ DRIP @ BTM <br />OVER J-SHAPE TRIM ON 2xl2 <br />VENTED SOFFIT PANELS <br />PREFINISHED BRAKE METAL <br />TRIM w/ DRIP <br />EIFS DENTIL BEYOND <br />4" EIFS OVER PLYWOOD <br />PER TYPICAL <br />BACKER ROD & SEALANT w/ <br />WEEPS PER EIFS MFGR <br />STUCCO <br />'low <br />..................... <br />t18'-10" T/ BLOCKING <br />NV TYPICAL PARAPET <br />D8 <br />18-1 <br />,.....: <br />A401 T/ TRUSS UPRIGHT <br />2x6 TRUSS EXTENSION TO <br />=�- BE INTEGRAL PART OF <br />ROOF TRUSS AS PER MFG� <br />4" EIFS, TYPICAL <br />r <br />DRIP EDGE @ BTM OF <br />EIFS w/ FLASHING <br />FR MFGR, TYPICAL <br />ANCHOR BOLTS <br />SHALL HAVE <br />2"x2"016" PLATE <br />WASHERS, TYP. <br />PROVIDE CONTROL JOINT IN <br />STONE AT CHANGE IN <br />SUBSTRATE <br />TRUSS SPAN SHALL BE 1" <br />SHORTER THAN OUT TO <br />OUT OF C.M.U.. FACE OF <br />SHEATHING SHALL BE <br />HLUSH WITH OUTSIDE <br />FACE OF C.M.U. <br />LINTEL SEE FR'G PLAN <br />H1 <br />4101 <br />5/8" DRYWALL RETURN; <br />SEAL FULL PERIMETER <br />THERMAL BREAK ALUM. WINDOW <br />FRAME PER SHEET Al04 <br />�— MFGR'D STONE <br />VENEER ON PIER <br />SOLID SURFACE STOOL <br />WITH 1-1/2" x 3/4" NOSE <br />TYPICAL WALL CONSTRUCTION <br />FROM INSIDE WALL: <br />• 5/8" GYP BD <br />• 15/8" FURRING STUDS <br />• 1 1/2" CONTINUOUS R-13.5 <br />RIGID INSULATION <br />8" C.M.U. <br />EXTEND JOINT <br />REINF. INTO 4" PIERS <br />i @ ALL REINF. <br />LAYERS (16" O.C.), ............ <br />0'-0" <br />T/ SLAB <br />............ <br />�— EXTEND 4" CMU PILASTERS <br />TO FOOTING, TYPICAL <br />1 <br />WALL SHEATHING OR C.M.U. AS <br />APPLICABLE <br />AIR INFILTRATION BARRIER, <br />FULL HEIGHT OF WALL. <br />I FINISH COAT OVER BASE <br />COAT & REINF. MESH <br />FASTEN EIFS SYSTEM DRAINAGE <br />TRACK TO SHEATHING OVER AIR <br />BARRIER LAP & BASE FLASHING. <br />EIFS INSULATION BOARD <br />LAP AIR INFILTRATION <br />SEALANT BED UNDER <br />BARRIER OVERTOP EDGES OF <br />} FLASHING @ SILL. <br />W.R.B. & BASE FLASHING. AIR o, <br />BARRIER MUST BE INSTALLED <br />1 <br />FULL HEIGHT wl UPPER <br />SHEETS LAPPED OVER TOP <br />EDGE OF LOWER SHEETS. <br />ONE LAYER W.R.B. TO EXTEND <br />ABOVE STONE AS SHOWN. <br />BASE FLASHING TO BE INSTALLED <br />BEHIND AIR BARRIER LAP @ TOP OF °- a <br />STONE / SILL. WHERE SILL IS NOT <br />PRESENT, PROVIDE DRIP EDGE. <br />TYPICAL. <br />SILL WHERE SHOWN ON <br />ELEVATIONS <br />STONE VENEER AND MORTAR BED € <br />PER G8l A402 @ SHEATHING ° a <br />TRANSITION DETAIL <br />ENO SCALE <br />ONE LAYER WEATHER <br />RESISTIVE BARRIER. INSTALL <br />IN TWO SECTIONS: STOP a, <br />LOWER PORTION BEHIND SILL <br />FLASHING. LAP BOTTOM OF <br />UPPER PORTION OVER SILL <br />FLASHING. <br />1100, BASE FLASHING @ TOP OF SILL <br />C.M.U. SUBSTRATE <br />AIR INFILTRATION BARRIER, p <br />FULL HEIGHT. <br />SILL SUPPORT ANGLE PER a a <br />....................................... t20'-10" TI BLK'G H4 / A401 L 4 <br />MV �L- - -------- - --- <br />HIGH PARAPET STONE VENEER PER G8 / A401 I <br />@ REAR <br />LL�LU <br />i <br />t18'-10" T/ BLOCKING <br />CM <br />w a <br />TYPICAL PARAPET <br />o w = <br />A401 <br />18' 1° <br />Z <br />' <br />T/ PARAPET BEYOND <br />SEE ELEVATIONS ON <br />_ <br />SHEET A201 FOR <br />w <br />SIGNAGE <br />REQUIREMENTS <br />o <br />ti <br />ti <br />LU <br />w <br />a. <br />E8 SIM <br />o <br />A401 LL <br />o <br />0 <br />�» <br />0 <br />J <br />CONTINUE THERMAL <br />BATTS MIN 12" ABOVE <br />ZL <br />ROOF INSUL, TYP. <br />2'.0" <br />o <br />METAL FLASHIN( <br />CONTROL JOINT <br />PROVIDE 2x8 BLK'G <br />EIFS BOARD @ S <br />ALIGNED WITH <br />_._ __.. <br />BTWN TRUSSES; NAIL <br />TRANSITION <br />ROOF DECK <br />_.........:..........:...._>... <br />..................... ...................4,.-........ <br />,....;..,.w ••, m ...::x::::;:::::>:.............................. <br />��..m.,• ,:.r�: :..�r::ms«..,,�»,w <br />....... <br />ROOF DECK TO 2x8 <br />TRUSS SPA(•t,SHALL BE 1" <br />SHORTER TJNA N OUT TO <br />OUT OF C.M.�,, FACE OF <br />SHEATHING Ski. BE <br />HLUSH WITH OP�1 SIDE <br />FACE OF C.M.U.`; 'a <br />10'-3" <br />TRUSS BEARING: <br />CONTROL JOINT <br />ALIGNED w/ STRUCt.'; <br />SYSTEM CHANGE <.. <br />B5 <f <br />8'-0" <br />HEAD R.O. <br />8� <br />CONT. 2x4s NAILED TO TOP <br />CHORD OF TRUSSES <br />END WALL TRUSSES <br />PER 'MANU�ACTURER� <br />l J r, <br />.. <br />TRUSS CLIP PER TRUSS <br />TYPES, SHEET S102 <br />CEILING HT AND MATL <br />PER CEILING PLAN <br />�— INSTALL JAMB & HEAD <br />FLASHINGS AT ALL <br />WINDOWS; SEAL <br />3 f......,.. U,,, <br />2"x2"xl"x /18"THICK <br />ANGLES @ 16" O.0 <br />10# SCREW w/ 2" <br />PENETRATION MIN. <br />TYPICAL MFGR'D STONE <br />SILL AND SUPPORT BEHIND STONE VENEER, INSTALL ONE <br />3' 2" T/SILL LAYER WEATHER RESISTIVE BARRIER <br />TYPICAL U.N.O. (W.R.B.) OVER AIR INFILTRATION BARRIER <br />& C.M.0 OR SHEATHING <br />WINDOW TYPES <br />EXTEND WINDOW BASE <br />FLASHING OUT OVER ¢ GALVANIZED SELF -FURRING LATH OVER <br />SILL; SEAL BELOW S r DBL W.R.B., ANCHORED INTO C.M.U. wl <br />LUMIN 1" PENETRATION <br />him NOTE: WRAP SILL FLASHING oo <br />OVER WINDOW ROUGH w MORTAR BED w/ DEPTH PER <br />OPENING & BEHIND STONE MFGR'S INSTRUCTIONS <br />SILL, TYPICAL °° CONCEALED FLASHING & DRIP <br />EDGE @ WALL BASE <br />G8 TYPICAL STONE <br />y 401 ATTACHMENT <br />MFGR'D STONE STONE BACK-UP <br />0'-0" VENEER PER DETAIL <br />T/ SLAB v SCALE :1 1/2" = V-0" <br />VERTICAL WALL REINFORCEMENT <br />cHAI I LAP w/ BARS DOWELED INTO <br />FOOTING; SEE FOUNDATION <br />SECTIONS, TYPICAL. <br />WALL SECTION SECTION @ PIER WALL SECTION <br />H2 SCALE: 3/4" =1'-0" H 3 SCALE: 3/4" = V-0" H 4 SCALE: 3/4" =1'-0" <br />I-------------------------------------------------------------------------------- <br />NOTE: SECTIONS ABOVE INDICATE TYPICAL (NON -SHEAR WALL) FASTENING FOR WALL SHEATHING. SEE SHEAR WALL DIAGRAMS ON SHEET S102 FOR SHEATHING FASTENING AT SHEAR WALLS. <br />L------------------------------------------------------------------------------� <br />TRUSS SPAN SHALL BE 1" <br />SHORTER THAN OUT TO <br />OUT OF C.M.U. FACE OF <br />SHEATHING SHALL BE <br />FLUSH WITH OUTSIDE <br />FACE OF C.M.U. <br />10'-3" <br />T/ TRUSS BEARING <br />DRAPE FSK DOWN OVER <br />FURRING WALL AND RIGID <br />INSULATION, TYP. <br />8" C.M.U. TYPICAL BELOW <br />10'-0" AFF U.N.O. <br />VERTICAL BARS CENTERED <br />IN GROUTED CORES AS <br />PER FRAMING PLAN <br />CD <br />z <br />W <br />m <br />co <br />Cn <br />WALL FINISH OVER <br />SUBSTRATE OVER <br />— FURRING STUDS OVER o <br />CONTINUOUS <br />INSULATION. SEE A103 <br />FOR SUBSTRATES AND <br />FINISHES, TYP. <br />3'-2" T/ SILL <br />3Y TYPICAL U.N.O. <br />CHORD w/ ELEVATIONS <br />ON SHEET A201 <br />E6 TYPICAL BARRIER <br />A401 TRANSITION <br />MFGR'D STONE <br />VENEER PER DETAIL <br />HORIZ JOINT REINF. <br />@ 16" O.C., TYPICAL <br />WALL SECTION <br />H 5 SCALE :3/4" = V-0" <br />A <br />TRANSITION DETAIL <br />E6 NO SCALE <br />t2'-0112" OVERALL, TYPICAL <br />V-8" <br />'OP <br />T w/ <br />TALL PIER DETAIL <br />F8 SCALE :1 1/2" =1'-0" <br />3 COAT STUCCO SYSTEM OVER ONE <br />LAYER WEATHER RESISTIVE BARRIER <br />(W.R.B.) OVER AIR INFILTRATION BARRIER <br />& C.M.0 SUBSTATE AS SHOWN OR <br />SHEATHING <br />FASTENER <br />HORIZONTAL & VERTICAL STUCCO <br />CONTROL JOINT, TYPICAL. <br />SEE ELEVATIONS FOR C.J. LOCATIONS <br />FASTENER <br />NOTE: <br />W.R.B. SHALL BE CONTINUOUS <br />BEHIND CONTROL JOINT(S) WHERE <br />STUCCO SYSTEM HAS W.R.B. <br />STUCCO DETAIL <br />H" SCALE: 3" = V-0" <br />DETAIL <br />H7 SCALE: 3" = V-0" <br />DFFIT PANEL <br />" WIDE DECORATIVE <br />I.F.S. BRACKET(S) <br />I.F.S. FRIEZE BOARD, INSTALL <br />RAINAGE MEMBRANE BEHIND <br />TAINLESS STEEL FLASHING W( <br />RIP EDGE, TYPICAL <br />EALANT, TYPICAL <br />ti <br />O <br />N <br />Z �— <br />CD <br />04 <br />LU <br />CD (UUJ ch O <br />>� <br />� � <br />O <br />LU O <br />Z V� N U <br />U � <br />J E <br />C <br />J <br />J ` <br />_ N <br />c <br />CD C <br />2 - <br />LU <br />N <br />0 m y <br />W U U) 0 <br />CD <br />a CD <br />O c J <br />LU <br />a Y a) Q >, <br />CO <br />LO 1= <br />O <br />to °aU--5 <br />N <br />U <br />LU <br />H <br />2 <br />U <br />�C <br />Z <br />H <br />DC <br />Co <br />o <br />0 o CD <br />L <br />C/) to 0 x <br />N <br />Z N TALL. <br />W <br />�.�rnrn <br />Z ti f` <br />� <br />a 0 ova <br />U) -O Ln u) <br />J o : Lo Lo <br />0 OEMA <br />All rights reserved; any copying, <br />transmittal or disclosure subject <br />to OEMA written approval. <br />♦♦ ^^ > <br />vJ � <br />Z <br />0 <br />I- <br />ti <br />W p <br />V J <br />CO <br />J ai <br />CU <br />Q <br />2017-054 <br />A401 <br />