Design No. U419
<br />Nonbearing Wall Rating - 1, 2, 3 OR 4 HR.
<br />For Number of Layers 4
<br />and Hourly Ratings
<br />See Item 4
<br />3 3A 2
<br />1 4
<br />1. Floor and Ceiling Runners - (Not shown) -- Channel shaped, fabricated from min. 25 MSG (min. 20 MSG
<br />when Item 4A is used) corrosion -protected steel, min. width to accomodate stud size, with min. 1 in. long
<br />legs, attached to floor and ceiling with fasteners 24 in. OC max.
<br />2, Steel Studs -- Channel shaped, fabricated from min. 25 MSG (min. 20 MSG when Item 4A is used)
<br />corrosion -protected steel, min. width as indicated under Item 4, min. 1-1/4 in. flanges and 1/4 in. return,
<br />spaced a max of 24 in. OC. Studs to be cut 318 to 3/4 in. less than assembly height.
<br />3. Batts and Blankets* -- (Required as indicated under Item 4) - Mineral wool batts, friction fitted between
<br />studs and runners. Min. nom, thickness as indicated under Item 4. See Batts and Blankets (BKNV or
<br />BZJZ) Categories for names of classified companies.
<br />4. Gypsum Board* -- Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally.
<br />Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints
<br />in adjacent layers (multilayer systems) staggered one stud cavity. Horizontal joints need not be backed by
<br />steel framing. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be
<br />staggered. Horizontal edge joints and horizontal butt joints in adjacent layers (multilayer systems) staggered
<br />a min. of 12 in. The thickness and number of layers for the 1 hr, 2 hr, 3 hr, and 4 hr ratings are as follows:
<br />Wallboard Protection on Each Side of Wall
<br />Rating Min. Stud Depth No. of Layers and Min. Thickness of
<br />Thickness of Panel Insulation (Rem 3)
<br />1 3-1/2 1 layer, 518 in. thick Optional
<br />1 2-1/2 1 layer, 1/2 in. thick 1-1/2 in.
<br />1 1-5/8 1 layer, 314 In. thick Optional
<br />2 1-5/8 2layers, 1/2 in. thick Optional
<br />2 1-5/8 2 layers, 5/8 in. thick Optional
<br />2 3-1/2 1 layer, 3/4 in. thick 3 in.
<br />3 1-5/8 3 layers ,112 in. thick Optional
<br />3 1-5/8 2 layers, 3/4 in. thick Optional
<br />3 1-5/8 3 layers, 5/8 in. thick Optional
<br />4 1-5/8 4 layers, 5/8 in. thick Optional
<br />4 1-5/8 4layers, 112 in, thick Optional
<br />4 2-1/2 2 layers, 314 in. thick 2 in.
<br />UL DESIGN NO. U419
<br />SCALE: NOT TO SCALE
<br />1-hr. Fire Rated Assembly
<br />(seen NER 258)
<br />USG Steel J-Runner
<br />1" SHEETROCK Brand
<br />gypsum shaft wall liner
<br />Power -actuated
<br />fasteners 24" O.C. USG steel C-H
<br />(300-I. shear) stud 24" o.c.
<br />I
<br />—518" SHEETROCK
<br />Brand gypsum panels.
<br />Sealant FIRECODE C core
<br />U.S.G. CORP.
<br />NER 258
<br />SCALE: NOT TO SCALE
<br />Design No. U437
<br />Nonbearing Wall Rating -1 or 2 HR. (See Item 5)
<br />Horizontal Section
<br />7-7
<br />0
<br />Oat/
<br />J O
<br />I /�
<br />Vertical Section
<br />1. Floor and Ceiling Runners — "J"-shaped runner, min 4 in. deep with unequal legs of 1 in. and 2 in., fabricated
<br />from 20 MSG galv steel. Runners positioned with short leg toward finished side of wall. Runners attached to
<br />structural supports with steel fasteners located not greater than 2 in. from ends and spaced no more than 24 in.
<br />OC.
<br />2, Vertical Runners — "J"-shaped runner, min 4 in. deep with unequal legs of 1 in. and 2 in., fabricated from 20
<br />MSG galv steel. Vertical runners positioned at each end of the wall with short leg toward finished side of wall.
<br />Runners attached to structural supports with steel fasteners located not greater than 2 in. from ends and spaced
<br />no more than 24 in. OC.
<br />3. Steel Studs — "C-H" -shaped studs, min 4 in. deep, with 1-1/2 in. wide flanges, fabricated from 20 MSG galv
<br />steel. Installed horizontally, with the "C" section of the studs facing down, friction fitted in the vertical "J"-shaped
<br />runners resting upon 2 by 2 in. by 20 ga. steel angles which are fastened to the side "J"-shaped runners. Studs cut
<br />to lengths to allow a 3/8 to 1/2 in. gap at each end of the wall, and spaced vertically 24 in. or 600 mm OC. As an
<br />option, the studs may be screw attached to the side "J"-shaped runners. A total of four 112 in. long pan -head steel
<br />screws are to be installed, one at each end of the stud on each side of the wall.
<br />4. Gypsum Board* —1 in. thick gypsum wallboard liner panels, supplied in nom 24 in. or 600 mm (for metric
<br />spacing) widths. Panels cut to lengths 1 in. less than the width of the wall. Once between the vertical "J"-shaped
<br />runners, the panels are centered to split equally at each end the 1 in. gap. Installed horizontally, with the long
<br />edges inserted in the "H" section of the "C-H"-shaped studs. The top edge of the liner panel shall be cut 1 in. less
<br />than opening height to allow installation past the 1 in. leg of J-runner. Free edge of panels attached to the long leg
<br />of the top and bottom "J" -runners with 1-5/8 in. long Type S or S-12 steel screws spaced no more than 12 in. OC.
<br />The width of the wall is limited to the length of the liner panels (no butt joints in the liner panels).
<br />CANADIAN GYPSUM COMPANY — Type SLX
<br />UNITED STATES GYPSUM CO — Type SLX
<br />USG MEXICO S A DE C V — Type SLX
<br />5. Gypsum Board* — 518 in. thick, 24 to 54 in. wide gypsum panels applied vertically in one (1-hr system) or two
<br />(2-hr system) layers. Vertical joints between panels need not be backed by framing. Vertical joints between layers
<br />staggered a minimum of 12 in. Horizontal joints centered over studs and staggered a minimum of 24 in. in adjacent
<br />courses and 24 in, between layers. 1-Hr System: Single layer attached to studs and vertical and horizontal
<br />"J"-shaped runners with 1 in. long Type S or S-12 steel screws spaced 8 in. OC. Joints covered with paper tape
<br />and joint compound. Exposed screw heads covered with joint compound. Joint tape and compound may be
<br />omitted when square edge panels are used. 2-Hr System: Base or inner layer attached to studs and vertical and
<br />horizontal "J"-shaped runners with 1 in. long Type S or SA 2 steel screws spaced 12 in. OC. Outer or face layer
<br />attached to studs and vertical and horizontal "J"-shaped runners with 1-5/8 in. long Type S or S-12 steel screws
<br />spaced 8 in. OC. Outer layer joints covered with paper tape and joint compound. Exposed screw heads covered
<br />with joint compound. Joint tape and compound may be omitted when square edge panels are used.
<br />CANADIAN GYPSUM COMPANY — Type AR, IP-AR, IP-X1, SCX or WRX
<br />UNITED STATES GYPSUM CO — Type AR, IP-AR, IP-X1, SCX, WRX or
<br />FRX-G
<br />USG MEXICO S A DE C V — Type AR, IP-AR, IP-X1, SCX or WRX
<br />6. Batts and Blankets* — (Optional - Not shown) — Mineral wool or glass fiber batts partially or completely filling
<br />stud cavity. Any mineral wool or glass fiber batt material bearing the UL Classification Marking as to Surface
<br />Burning Characteristics and/or Fire Resistance.
<br />*Bearing the UL Classification Mark
<br />UL DESIGN NO. U437 I
<br />SCALE: NOT TO SCALE
<br />Design No. U905
<br />Bearing Wall Rating -- 2 Hr.
<br />Nonbearing Wall Rating -- 2 Hr.
<br />�14— — — — — — — — — — — — — — — — — — — — —
<br />n o. 0
<br />3 Min.
<br />2 4
<br />Horizontal Section
<br />1. Concrete Blocks* -- Various designs. Classification D-2 (2 hr). See Concrete Blocks category for list of
<br />eligible manufacturers.
<br />2. Mortar - Blocks laid in full bed of mortar, nom. 3/8 in. thick, of not less than 2-1/4 and not more than 3-1/2
<br />parts of clean sharp sand to 1 part Portland cement (proportioned by volume) and not more than 50
<br />percent hydrated lime (by cement volume). Vertical joints staggered.
<br />3. Portland Cement Stucco or Gypsum Plaster - Add 1/2 hr. to classification if used. Where combustible
<br />members are framed in wall, plaster or stucco must be applied on the face opposite framing to achieve a
<br />max. Classification of 1-1/2 hr. Attached to concrete blocks (Item 1).
<br />4. Loose Masonry Fill -- If all core spaces are filled with loose dry expanded slag, expanded clay or shale
<br />(Rotary Kiln Process), water repellant vermiculite masonry fill insulation, or silicone treated perlite loose fill
<br />insulation add 2 hr. to classification.
<br />5. Foamed Plastic* -- (Optional - Not Shown) -1-1/2 in. thick max, 4 ft. wide sheathing attached to concrete
<br />blocks (item 1).
<br />THE DOW CHEMICAL CO -- Type Thermax
<br />*Bearing the UL Classification Mark
<br />UL DESIGN NO. U905 I
<br />SCALE: NOT TO SCALE
<br />Furr,
<br />Wegman &
<br />Banks
<br />Architects, P.A. AR0006480
<br />625 EAST ORANGE ST.
<br />LAKELAND, FL 33801
<br />E-MAIL: INFO@FWBARCHITECTS.COM
<br />WWW.FWBARCHITECTS.COM
<br />PH. 863.688.1211
<br />0 COPYRIGHT 2021
<br />FURR, WEGMAN & BANKS ARCHITECTS, PA
<br />THE DESIGN AND CONCEPTS DEPICTED HEREWITH ARE THE SOLE
<br />PROPERTY OF FURR. WEGMAN & BANKS ARCHITECTS, PA.
<br />NO REPRODUCTION, REVISION OR REUSE OF THIS DRAWING IS
<br />AUTHORIZED WITHOUT SPECIFIC WRITTEN PERMISSION.
<br />ALL RIGHTS RESERVED.
<br />Lrl
<br />(n to
<br />14 DO
<br />Z Q
<br />a (T
<br />co
<br />O E.9
<br />v._\
<br />a
<br />Z W 1�
<br />FY
<br />a _
<br />U
<br />d'
<br />a
<br />J
<br />Z
<br />O
<br />I—
<br />Lu
<br />Lu
<br />rn
<br />_
<br />I—
<br />z
<br />0
<br />0
<br />LLl
<br />0
<br />z
<br />0
<br />Lu
<br />W
<br />0
<br />aN co v LO cfl t`
<br />N
<br />O
<br />N
<br />ti
<br />N
<br />OD
<br />0
<br />W
<br />H
<br />Q
<br />H
<br />U) z
<br />(D W
<br />V
<br />z
<br />~ 0
<br />Z Z
<br />J J_J O
<br />f J� C)
<br />F z z Z
<br />LLl U) U
<br />C0 O
<br />LL D 0
<br />0�u C)C0 3:~10� Z J
<br />w 20 W
<br />LL > 0 a
<br />J U) Q (0N
<br />PROJ MGR: CKD 17
<br />ACT MAB
<br />JOB NUMBER:
<br />21-19
<br />SHEET NUMBER:
<br />L S 10 1
<br />
|