Laserfiche WebLink
t <br />GENERAL NOTES: <br />1. CONTRACTOR IS RESPONSIBLE FOR AND SHALL VERIFY AND <br />COORDINATE ALL DIMENSIONS AND DETAILS BEFORE PROCEEDING WITH <br />WORK. ANY DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE <br />ATTENTION OF THE ARCHITECT AND ENGINEERS. <br />2. DETAILS SHOWN IN ANY SECTION APPLY TO ALL SIMILAR SECTIONS AND <br />CONDITIONS UNLESS NOTED OTHERWISE. <br />3. CONTRACTOR SHALL FULLY BRACE AND OTHERWISE PROTECT ALL WORK <br />IN PROGRESS UNTIL THE BUILDING IS COMPLETED. <br />4. ALL STRUCTURAL ITEMS FOR THIS PROJECT HAVE BEEN DESIGNED IN <br />ACCORDANCE WITH APPROPRIATE PROVISIONS OF EACH OF THE <br />FOLLOWING: <br />A. THE FLORIDA BUILDING CODE, (SEVENTH EDITION) 2020. <br />B. CI STANDARD 318-14 BUILDING CODE REQUIREMENTS FOR <br />REINFORCED CONCRETE. <br />C. BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (TMS <br />402-16). <br />D. AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION <br />OF STRUCTURAL STEEL FOR BUILDINGS" 360-16. <br />E. NDS FOR WOOD CONSTRUCTION WITH 2O18 NDS SUPPLEMENT. <br />F. ASCE 7-16 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER <br />STRUCTURES". <br />5. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE <br />SPECIFICATIONS AND THE ARCHITECTURAL AND MECHANICAL DRAWINGS. <br />IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE <br />CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE ARCHITECT PRIOR TO <br />PERFORMING WORK. IN CASE OF CONFLICT THE MOST STRINGENT <br />CONDITION SHALL APPLY. <br />6. ALL DIMENSIONS MUST BE COORDINATED WITH ARCHITECTURAL <br />DRAWINGS AND WITH EQUIPMENT MANUFACTURER (I.E. WINDOW, DOOR, <br />AIR HANDLER, ETC.). CONTRACTOR MUST OBTAIN AN ARCHITECTURAL <br />DIRECTIVE IN CASE OF ANY CONFLICT. REFER TO ARCHITECTURAL <br />DRAWINGS FOR DIMENSIONS NOT SHOWN IN STRUCTURAL DRAWINGS. <br />7. ROOFTOP EQUIPMENT ANCHORAGE & OUTDOOR RACK MOUNTED <br />EQUIPMENT ANCHORAGE. ALL ROOF TOP EQUIPMENT CURBS, ROOF TOP <br />MECHANICAL EQUIPMENT, EQUIPMENT TIE DOWNS, AND CONNECTIONS <br />OF ALL EQUIPMENT TO OUTDOOR RACKS OR BUILDING STRUCTURE FOR <br />WIND LOADING ARE TO BE DESIGNED AND ENGINEERED BY A <br />REGISTERED SPECIALTY ENGINEER RETAINED BY THE MECHANICAL <br />EQUIPMENT SUPPLIER. SIGNED AND SEALED DRAWINGS AND <br />CALCULATIONS ARE TO BE SUBMITTED TO THE ENGINEER OF RECORD <br />FOR REVIEW AND APPROVAL. THE EQUIPMENT MANUFACTURER SHALL <br />PROVIDE THE ATTACHMENT OF THE UNIT TO THE STRUCTURE AND <br />SUBMIT TO THE ENGINEER LOADS, LOCATIONS, AND METHODS OF <br />ATTACHMENT. THE STRUCTURAL ENGINEER WILL MAKE PROVISIONS IN <br />THE DESIGN OF THE PRIMARY STRUCTURAL FRAME TO ACCOMMODATE <br />THE LOADS AND ATTACHMENTS SUBMITTED BY THE MANUFACTURER. <br />CONCRETE AND REINFORCING: <br />1. ALL CONCRETE WORK SHALL CONFORM TO THE LATEST ACI "BUILDING CODE <br />REQUIREMENTS FOR REINFORCED CONCRETE, ACI-318". <br />2. ALL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTHS AS <br />INDICATED BELOW: <br />CONCRETE MAX WATER TYPE <br />STRENGTH CEMENT RATIO AGGREGATE LOCATION USED <br />5000 PSI 0.42 STONE CONCRETE U.N.O. <br />4000 PSI 0.45 STONE FOUNDATIONS <br />3000 PSI 0.52 STONE SLAB ON GRADE <br />3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE, NEW BILLET STEEL, <br />DEFORMED BARS, CONFORMING TO ASTM A-615, GRADE 60. ALL BARS SHALL BE <br />SECURELY SUPPORTED AND WIRED IN PLACE. PRIOR TO POURING CONCRETE. <br />ALL REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A-706. <br />4. ALL WELDED WIRE FABRIC (W.W.F.) IN FLAT SHEETS ONLY AND SHALL CONFORM <br />TO ASTM A-185. <br />5. UNLESS NOTED, ALL BARS MARKED CONTINUOUS SHALL BE SPLICED AT ALL LAP <br />POINTS AND CORNERS AND DEVELOPED AT NON -CONTINUOUS ENDS AS PER <br />TYPICAL DETAILS. SPLICE CONTINUOUS TOP BARS AT CENTER BETWEEN <br />SUPPORTS AND SPLICE CONTINUOUS BOTTOM BARS AT SUPPORTS. <br />6. CONCRETE COVER FOR REINFORCING BARS SHOWN IN TYPICAL DETAILS. <br />7. UNLESS NOTED, TEMPERATURE REINFORCING (ASTM A-615-60) TO BE 0.0018 X <br />CONCRETE AREA. <br />8. PROVIDE #4 @ 12" O.C., WITH STANDARD HOOK, TOP BARS IN ALL SLABS AT <br />DISCONTINUOUS ENDS UNLESS OTHERWISE NOTED ON PLANS. LENGTH OF <br />BARS 1/4 OF SPAN, MINIMUM 3'-0". UNLESS OTHERWISE NOTED PROVIDE #4 @ 12" <br />O.0 IN ALL CANTILEVERS. BAR LENGTH SHALL BE CANTILEVER SPAN PLUS 10'-0" <br />PLUS STANDARD HOOK AT CANTILEVER ENDS. <br />9. WHERE PIPE SLEEVES (UP TO 2" IN DIAMETER) PASS THROUGH CONCRETE <br />BEAMS, PROVIDE ADDITIONAL STIRRUP EACH SIDE OF SLEEVE, SLEEVES FOR <br />PIPES 2" IN DIAMETER OR LARGER MUST BE STEEL OR CAST IRON, AND THE <br />LOCATION MUST BE APPROVED BY THE STRUCTURAL ENGINEER. <br />10. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED JUST BEFORE <br />PLACING NEW CONCRETE IN ACCORDANCE WITH THE BUILDING CODE. <br />11. FOR CHAMFER OF EXPOSED CORNERS OF BEAMS AND/OR COLUMNS, SEE <br />ARCHITECTURAL DRAWINGS. <br />12. CONTRACTOR SHALL COORDINATE PLACEMENT OF, OR BOX OUT FOR, ALL PIPE <br />SLEEVES, OPENINGS, ETC, REQUIRED FOR VARIOUS TRADES. <br />13. CONTRACTOR SHALL COORDINATE AND NOTIFY OTHER TRADES IN SUFFICIENT <br />TIME TO ALLOW THEM TO SET ANCHORS, INSERTS, BOLTS, HANGERS, ETC., AS <br />REQUIRED FOR THEIR USE. <br />14. SEE ARCHITECTURAL DRAWINGS FOR DETAILS OF FLASHING REGLETS, FASCIA <br />DETAILS, ETC. <br />15. UNDER NO CIRCUMSTANCES SHALL CONCRETE BE PUMPED THROUGH <br />ALUMINUM PIPES. CONCRETE SHALL NOT BE PLACED IN CONTACT WITH <br />ALUMINUM, ALUMINUM MIXING DRUMS, TRUCK MIXERS, BUGGIES, CHUTES, <br />CONVEYORS, TREMIE PIPES, AND OTHER EQUIPMENT MADE OF ALUMINUM <br />SHALL NOT BE USED ON THIS PROJECT. <br />16. SLUMPS OF OVER 4 INCHES WILL NOT BE PERMITTED UNLESS THE HRWR <br />ADMIXTURE (SUPER PLASTICIZER) IS USED. MAXIMUM SLUMP IS THEN 8 INCHES <br />UNLESS OTHERWISE DIRECTED BY THE ENGINEER. <br />17. NO ADMIXTURE SHALL BE USED IN CONCRETE EXCEPT WITH THE PERMISSION <br />OF THE ENGINEERS AND AFTER LABORATORY DESIGN MIX APPROVAL. ALL <br />ADMIXTURES SHALL CONTAIN NO MORE CHLORIDE IONS THAN ARE PRESENT IN <br />MUNICIPAL DRINKING WATER. <br />18. WATER REDUCING ADMIXTURE SHALL CONFORM TO THE ASTM C-494, TYPE A, <br />AND SHALL BE USED IN ALL CONCRETE. <br />19. AIR ENTRAINING ADMIXTURE,SHALL CONFORM TO ASTM C260. AIR CONTENT OF <br />CONCRETE SHALL BE USED AS FOLLOWS: <br />A. FOR CONCRETE EXPOSED TO SOIL AND/OR WEATHER, 5%. <br />B. FOR INTERIOR WALLS, COLUMNS, AND SLABS, 3%. <br />20. FLY ASH - ASTMC618, TYPE, C OR TYPE F SHOULD BE USED BUT NOT TO EXCEED <br />20% CEMENTITIOUS CONTENT. <br />21. ALL EXPOSED CONCRETE SHALL RECEIVE A CURING COMPOUND. THE CURING <br />COMPOUND SHALL CONFORM TO ASTM C309 AND SHALL HAVE 30% SOLIDS <br />MINIMUM. WATER/BLANKET CURING AS PER ACI RECOMMENDATION MAY BE <br />USED AS ALTERNATE. <br />GENERAL STRUCTURAL NOTES <br />FOUNDATION NOTES: <br />1. FOUNDATIONS FOR THIS PROJECT HAVE BEEN DESIGNED ASSUMING THE <br />SOIL IS SUITABLE TO SUPPORT 2000 PSF SPREAD FOOTINGS WITH <br />SETTLEMENT NOT TO EXCEED 1/8". CONTRACTOR MUST CONTACT A <br />GEOTECHNICAL ENGINEER TO DO A SOIL EXPLORATION WHICH MUST <br />INCLUDE BORINGS AT A MINIMUM RATE OF ONE FOR EVERY 3000 SQUARE <br />FOOT OF BUILDING BUT NOT LESS THAN TWO BORINGS. THE BORINGS <br />MINIMUM DEPTH SHOULD BE TWENTY FIVE FEET (25'-01 OR TWICE THE <br />LARGEST DIMENSION OF THE LARGEST FOUNDATION WHICH EVER IS <br />GREATER. THESE REQUIREMENTS MAYBE MODIFIED AT THE DISCRETION OF <br />THE GEOTECHNICAL ENGINEER. A REPORT SIGNED AND SEALED BY A <br />PROFESSIONAL GEOTECHNICAL ENGINEER MUST BE SUBMITTED TO MCE <br />PRIOR TO ANY FOUNDATION WORK. <br />2. FILL AND SUBGRADE PREPARATION SHALL BE AS NEEDED TO OBTAIN THE <br />SAFE BEARING PRESSURE INDICATED ON NOTE 1. ALL ORGANICS AND <br />UNSUITABLE SOIL SHOULD BE REMOVED AND A MINIMUM OF 98% MUST BE <br />OBTAIN UNLESS GEOTECHNICAL ENGINEER RECOMMENDATIONS ALLOW A <br />LOWER PERCENT OF COMPACTION, <br />3. ALL COLUMN AND WALL FOOTINGS SHALL BE CENTERED UNDER COLUMN <br />AND WALL CENTERLINES UNLESS OTHERWISE NOTED. <br />4. BACKFILLING AGAINST FOUNDATION WALLS SHALL BE DONE CAREFULLY <br />WITH SMALL COMPACTION EQUIPMENT, AFTER SLABS ON GROUND ARE IN <br />PLACE AND CONCRETE HAS SET. NO TRUCKS, BULLDOZERS, ETC. SHALL BE <br />ALLOWED CLOSER THAN U-0" TO ANY FOUNDATION WALL. ANY WALL 3'-0" <br />OR HIGHER MUST BE BRACED DURING THE CONSTRUCTION PROCESS. <br />5. NO FOUNDATIONS SHALL BE PLACED ABOVE 1 VERTICAL ON 2 HORIZONTAL <br />SLOPES EXTENDED FROM THE CLOSEST EDGE OF ANY UNDISTURBED SOIL <br />OR OTHER FOUNDATION STRUCTURE. BOTTOM OF FOOTINGS SHALL NOT <br />BE LESS THAN V-0" BELOW EXISTING GRADE (U.N.O.). <br />6. FOR FOUNDATIONS SIZE AND REINFORCING SEE SCHEDULE. <br />7. CONTRACTOR SHALL TREAT SOIL BENEATH BUILDING FOR TERMITES. <br />MASONRY: <br />1. DESIGN AND CONSTRUCTION SHALL CONFORM TO BUILDING CODE <br />REQUIREMENTS FOR MASONRY STRUCTURES (ASCE 7-16) / TMS 402-16. <br />2. MINIMUM NET COMPRESSIVE STRENGTH OF BLOCK ASSEMBLY SHALL <br />BE 2000 P.S.I. (fm) MORTAR FOR MASONRY SHALL BE TYPE "S" OR "M". <br />3. FOR ALL EXTERIOR AND INTERIOR BEARING, BED JOINTS ARE TO <br />0 <br />COVER 100 /o OF THE MASONRY SURFACES AND ALL HEAD JOINTS ARE <br />TO COVER 100% OF THE PROJECTED AREA OF THE FACE SHELLS. <br />4. FILL ALL CELLS AS REQUIRED WITH 3000 P.S.I. GROUT. SLUMP SHALL BE <br />8 TO 11 INCHES. SUBMIT DESIGN MIX FOR APPROVAL. <br />5. MINIMUM HORIZONTAL JOINT REINFORCING SHALL BE 9 GAGE HOT DIP <br />GALVANIZED TRUSS OR LADDER TYPE JOINT REINFORCING AT 16" O.C., <br />PROVIDE MANUFACTURE "T' AND "L" SHAPES FOR INTERSECTIONS AND <br />CORNERS, (MINIMUM LAP 8"). <br />6. MINIMUM VERTICAL REINFORCING SHALL BE (1)-#5 @ 48" OR (1)-#4 @ 32" <br />O.C., (U.N.O.). <br />7. PROVIDE ADDITIONAL VERTICAL REINFORCING BAR AT EVERY CORNER, <br />INTERSECTION, CONTROL JOINT, AND OPENING EDGES (U.N.O.). <br />8. MINIMUM SPLICE FOR VERTICAL REINFORCING IS SHOWN IN DETAIL <br />4-023, SPLICE FOR HORIZONTAL JOINT REINFORCING = 12". <br />9. WALLS ARE DESIGNED TO BE BRACED BY FLOOR OR ROOF MEMBERS, <br />CONTRACTOR SHALL PROVIDE TEMPORARY BRACING DURING <br />CONSTRUCTION. <br />10. ALL CELLS BELOW FIRST FLOOR FINISHED ELEVATION MUST BE FULLY <br />GROUT FILLED. <br />11. ALL KNOCK OUT BLOCK HORIZONTAL BARS SHALL HAVE CORNER BARS <br />AT ALL CORNERS AND WALL INTERSECTIONS. SIZE AND NUMBER OF <br />CORNER BARS SHALL BE SAME AS HORIZONTAL BARS. <br />12. ALL INTERSECTING WALLS AND CORNER WALLS SHALL BE LAID IN AN <br />OVERLAPPING MASONRY BONDING PATTERN, WITH ALTERNATE UNITS <br />HAVING A BEARING OF NOT LESS THAN 3 INCHES ON UNIT BELOW. <br />PRECAST CONCRETE FRAMING NOTES: <br />1. 8" PRECAST PLANK SUPPORTED ON CAST IN PLACE CONCRETE BEAMS. <br />2. SEE DRAWING S301 TO S403 FOR DETAILS AND SECTIONS. <br />3. FOR ROOF DRAIN LOCATION, SEE ARCHITECTURAL AND MECHANICAL <br />DRAWINGS. R.D. SHALL BE INDICATED ON SHOP DRAWINGS AND THEIR <br />LOCATION APPROVED BY STRUCTURAL ENGINEER. <br />4. PRECAST SCHEDULE: <br />MIN. 28 DAYS STRENGTH (PSI) COARSE AGGREGATE <br />PLANK 5,000 STONE <br />5. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE, NEW BILLET STEEL, <br />DEFORMED BARS, CONFORMING TO ASTM A-615, GRADE 60. ALL REINFORCING <br />BARS TO BE WELDED SHALL BE DEFORMED BARS CONFORMING TO ASTM A706, <br />GRADE 60. WELDING OF REBARS SHALL BE IN ACCORDANCE WITH AWS D12.1 <br />"REINFORCING STEEL WELDING CODE". ALL BARS SHALL BE SECURELY <br />SUPPORTED AND WIRED IN PLACE PRIOR TO POURING CONCRETE. <br />6. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL PRECAST <br />COMPONENTS FOR REVIEW BY THE STRUCTURAL ENGINEER BEFORE <br />PRODUCTION. DRAWINGS SHALL BE SIGNED AND SEALED BY FLORIDA P.E. <br />7. THE CONTRACTOR SHALL CHECK ARCHITECTURAL, MECHANICAL AND <br />ELECTRICAL PLANS TO VERIFY SIZES AND LOCATIONS OF ALL OPENINGS, <br />REVEAL, DRIPS, BLACKOUTS, INSERTS, ETC. CAST INTO PRECAST MEMBERS. <br />8. THE ERECTION WORK AND STRUCTURAL STABILITY DURING THE <br />CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. <br />9. PRECASTER SHALL MAINTAIN FIRE RATING AS INDICATED IN CONSTRUCTION <br />TYPE ON THE ARCHITECTURAL DRAWINGS. THIS SHALL BE MAINTAINTED AT <br />ALL PANEL JOINTS, CONNECTIONS, SUPPORTS, AND RELATED ELEMENTS. <br />STEEL ROOF DECK: <br />1. STEEL ROOF DECK SHALL BE A MINIMUM OF 1-1/2" - 20 GAUGE WIDE RIB <br />FOR SPANS UP TO 6'-0" OR 3" TYPE N - 20 GAUGE FOR SPANS UP TO <br />12'-0". THE SIZE, TYPE AND GAUGE INDICATED ABOVE SHOULD BE USED <br />UNLESS A DIFFERENT ONE IS INDICATED IN THE ROOF FRAMING NOTES <br />OF THE ROOF PLAN DRAWING. <br />2. ALL STEEL ROOF DECK SHALL BE GALVANIZED G90 AS PER ASTM <br />SPECIFICATIONS. <br />3. ALL STEEL ROOF DECK SHALL BE CAPABLE OF SUPPORTING ALL <br />CONSTRUCTION LOADS. <br />4. ALL STEEL ROOF DECK SHALL BE CONTINUOUS OVER FOUR OR MORE <br />STRUCTURAL SUPPORTS (I.E. DECK SHOULD BE DETAILED FOR A THREE <br />SPAN CONDITION.) <br />5. STEEL ROOF DECK SHALL HAVE NESTING SIDE LAPS (ATTACHED BY <br />MECHANICAL MEANS). PROVIDE FASTENER LAYOUT AS PER TYPICAL <br />DETAIL 5-305. <br />6. IF DECK IS CUT IN SINGLE SPAN CONDITION, EACH END OF SUCH <br />SECTIONS SHALL BE WELDED TO ITS SUPPORT THROUGH WELDING <br />WASHERS IN THE BOTTOM OF EACH RIB. <br />7. IN AREAS WHERE THE DECK IS CUT AS PER NOTE 6, THE GAUGE OF THE <br />SINGLE SPAN DECK SHALL BE ADJUSTED UPWARDS AS REQUIRED BY <br />THE ENGINEER TO SUPPORT THE LOADS. <br />8. ANY ELECTRICAL WORK WEIGHING MORE THAN 5 PSF OR 50 LBS <br />CONCENTRATED SHALL BE HUNG FROM STEEL BEAMSMOISTS ONLY. <br />FOR HANGERS, SEE SPECIFICATIONS. ALL MECHANICAL WORK AND <br />PIPING SHALL BE HUNG FROM STEEL BEAMS/JOISTS. <br />9. METAL DECK CONTRACTOR TO PROVIDE 18 GAUGE RIDGE PLATE, <br />VALLEY PLATE, EDGE STRIP, ETC., AS REQUIRED. <br />10. STEEL ROOF DECK SHALL BE WELDED AT ENDS AND ALL INTERMEDIATE <br />SUPPORTING MEMBERS WITH 5/8" DIAMETER PUDDLE WELDS OR <br />ELONGATED WELDS OF EQUAL STRENGTH SPACED PER SPECIFICATIONS <br />IN THE BOTTOM OF THE RIB ACROSS THE WIDTH OF THE DECK UNIT. <br />11. CUT OUT METAL DECK WHERE BOLT PROJECTIONS INTERFERE WITH <br />METAL DECK. <br />12. DIRECTION OF METAL DECK SHOWN THUS P_ ON PLAN. <br />STRUCTURAL STEEL: <br />1. ALL STRUCTURAL STEEL WORK SHALL BE FABRICATED AND ERECTED IN <br />ACCORDANCE WITH THE LATEST A.I.S.C. SPECIFICATIONS. <br />2. STRUCTURAL STEEL SHALL CONFORM TO: <br />WIDE FLANGE (WF) <br />ASTM A992 (50 KSI) <br />SHAPES (L,T,C,PL) <br />ASTM A36 <br />STRUCTURAL TUBE (HSS) <br />ASTM A500 (46 KSI) <br />STEEL PIPE (HSS) <br />ASTM A500 (42 KSI) <br />ANCHOR BOLTS <br />ASTM F1554 (50 KSI) <br />FRAMING BOLTS <br />ASTM A325 OR A490 <br />SHEAR STUDS <br />ASTM A108 <br />WELDING ELECTRODES <br />E70XX <br />3. SHOP CONNECTIONS MAY BE WELDED OR HIGH STRENGTH BOLTED. ALL <br />BOLTS SHALL BE 3/4" DIAMETER MINIMUM. ALL CONNECTIONS SHALL <br />CONFORM TO THE TYPICAL CONNECTION DETAILS SHOWN ON THE PLANS <br />UNLESS SPECIFICALLY APPROVED BY THE ENGINEER. <br />4. ALL FIELD CONNECTIONS SHALL BE BOLTED WITH HIGH STRENGTH BOLTS, <br />SLIP -CRITICAL (FRICTION) TYPE EXCEPT WHERE SLOTTED HOLES ARE <br />SPECIFIED OR WHERE MOVEMENT OF THE CONNECTED MEMBERS IS <br />EXPECTED. IN THESE CASES PROVIDE OVERSIZED WASHER, HAND <br />TIGHTEN BOLTS, AND TACK WELD WASHER TO NUT TO VERIFY ASSEMBLY <br />IS HELD TOGETHER. <br />5. ALL WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY <br />CODE, ANS01.1, ALL WELDING SHALL BE PERFORMED USING E70XX U.N.O. <br />6. CUTS, HOLES, COPINGS, ETC. REQUIRED IN STRUCTURAL STEEL MEMBERS <br />FOR THE WORK OF OTHER TRADES SHALL BE SHOWN IN THE STRUCTURAL <br />STEEL SHOP DRAWINGS AND SHALL BE MADE IN THE SHOP. HOLES SHALL <br />BE REINFORCED AS REQUIRED BY THE ENGINEER. <br />7. BURNING OF HOLES, CUTS, ETC. IN STRUCTURAL STEEL MEMBERS IN THE <br />FIELD WILL NOT BE PERMITTED, EXCEPT WITH THE SPECIFIC APPROVAL OF <br />THE ENGINEER. <br />8. LL STEEL MEMBERS EXPOSED TO THE EXTERIOR/WEATHER (SUCH AS <br />LINTELS, DOOR JAMBS, ETC.) OR PERMANENTLY IN UNCONDITIONED SPACE <br />SHALL BE HOT DIPPED GALVANIZED. <br />9. FOR MISCELLANEOUS STEEL, SEE ARCHITECTURAL DRAWINGS. <br />10. ANY STEEL MEMBERS REQUIRED BY THE ELECTRICAL OR MECHANICAL <br />TRADES FOR THE SUPPORT OF THEIR EQUIPMENT, WHICH ARE NOT <br />SHOWN ONARCHITECTURAL OR STRUCTURAL DRAWINGS SHALL BE <br />PROVIDED BY THE TRADE REQUIRING SUCH SUPPORT. <br />11. SEE SPECIFICATIONS FOR PAINTING OF STRUCTURAL STEEL. ALL <br />FABRICATION AND ERECTION MARKS SHALL BE COVERED DURING FIELD <br />TOUCH-UP PAINTING. <br />12. WHEN STEEL MEMBERS ARE WELDED TO EMBED PLATES IN CONCRETE, <br />WELDING PROCESS SHOULD BE PERFORMED IN SUCH WAY THAT EMBED <br />PLATE DOES NOT OVERHEAT AND EXPAND. SUCH EXPANSION WILL CRACK <br />THE CONCRETE SURROUNDING THE EMBED PLATE AND MAY WEAKEN THE <br />STRUCTURAL CAPACITY OF THE CONNECTION. WE RECOMMEND TO <br />PROVIDE SEVERAL SINGLE PASSES TO BUILT UP THE WELD SIZE REQUIRE <br />WITH COOLING OFF PERIODS TO AVOID THE EMBED PLATE EXPANSION. <br />UNDER NO CIRCUMSTANCES PROVIDE MORE THAN 6" OF 1/4" WELD <br />WITHOUT ALLOWING A COOLING OFF PERIOD. <br />13. EXPOSED ENDS OF STRUCTURAL TUBES OR PIPES SHALL BE CAPPED WITH <br />A MINIMUM 1/4" PLATE U.N.O. <br />POST -INSTALLED ANCHORS <br />1. POST -INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON <br />THE CONSTRUCTION DOCUMENTS. SPECIAL INSPECTIONS ARE <br />REQUIRED PER THE PROVISIONS SET FORTH BELOW. CONTRACTOR TO <br />CONTACT MANUFACTURER'S REPRESENTATIVE FOR PROPER PRODUCT <br />INSTALLATION TRAINING ON INITIAL ANCHORS. <br />2. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE <br />SPECIFIED BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE <br />ENGINEER -OF -RECORD ALONG WITH CALCULATIONS THAT ARE <br />PREPARED & SEALED BY A REGISTERED PROFESSIONAL ENGINEER. THE <br />CALCULATIONS SHALL DEMONSTRATE THAT THE SUBSTITUTED <br />PRODUCT IS CAPABLE OF ACHIEVING THE PERTINENT EQUIVALENT <br />PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING <br />THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS <br />REQUIRED BY THE BUILDING CODE. <br />3. EXPANSION ANCHORS SHALL BE STUD TYPE WITH A SINGLE PIECE OF <br />THREE SECTION WEDGE AND ZINC PLATED IN ACCORDANCE WITH ASTM <br />B633. THE ANCHORS SHALL MEET FEDERAL SPECIFICATION FF-S-325, <br />GROUP II, TYPE 4, CLASS I FOR CONCRETE EXPANSION ANCHORS. <br />ANCHORS SHALL BE HILTI KWIK BOLT 3 AS SUPPLIED BY HILTI INC. TULSA <br />OKLAHOMA. ANCHORS SHALL BE INSTALLED IN HOLES DRILLED WITH <br />HILTI CARBIDE TIPPED DRILL BITS OR MATCHED TOLERANCE DIAMOND <br />CORE BITS. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH <br />MANUFACTURE'S RECOMMENDATIONS. <br />4. INJECTED ADHESIVE ANCHORS SHALL BE USED FOR INSTALLATION OF <br />THREADED RODS. ADHESIVE SHALL BE FURNISHED IN A SIDE BY SIDE <br />REFILL PACK WHICH KEEP COMPONENT A AND B SEPARATE. INJECTION <br />ADHESIVE SHALL BE HILTI HIT HY 200 AS SUPPLIED BY HILTI INC. TULSA <br />OKLAHOMA. ANCHOR RODS MEET ASTM F1554 (36 KSI). NUTS AND <br />WASHERS SHALL BE FURNISHED TO MEET THE REQUIREMENTS OF AN <br />ASTM F1554 (36 KSI) STEEL ROD. <br />SHOP DRAWINGS: <br />1. NO STRUCTURAL DRAWINGS SHALL BE REPRODUCED FOR USE AS SHOP <br />DRAWINGS. <br />2. ALL DIMENSIONAL COORDINATION SHALL BE DONE BY THE CONTRACTOR <br />AND/OR HIS DETAILER. <br />3. DETAILER SHALL CHECK ALL ARCHITECTURAL AND MECHANICAL <br />DRAWINGS FOR ALL ATTACHMENTS, CLIPS, OPENINGS, OR DUCT WORK <br />AFFECTING STRUCTURAL MEMBERS. ALL ITEMS SHALL BE SHOWN ON <br />SHOP DRAWINGS. <br />4. ALL SHOP DRAWINGS SHALL BE SUBMITTED ELECTRONICALLY IN PDF <br />FORMAT. DISTRIBUTION AS PER ARCHITECT INSTRUCTIONS. <br />5. PROVIDE SUFFICIENT SPACE ON SHOP DRAWINGS NEAR TITLE BOX (ABOUT <br />40 SQUARE INCHES) FOR STAMPS AND ENGINEERS COMMENTS. <br />6. THE SHOP DRAWINGS SHALL BEAR INITIALS OF DETAILER'S CHECKER AND <br />CONTRACTOR PRIOR TO SUBMISSION. <br />7. COMPLETED ERECTION PLANS SHALL BE SUBMITTED PRIOR TO OR IN <br />CONJUNCTION WITH DETAIL DRAWINGS. BUT IN NO CASE SHALL DETAIL <br />DRAWINGS BE SUBMITTED PRIOR TO ERECTION PLANS. <br />8. DETAILER SHALL SUBMIT AN INDEX OF THE DETAIL DRAWINGS WITH EACH <br />SHOP DRAWING SUBMITTAL. <br />9. SHOP DRAWINGS NOT COMPLYING WITH ALL THE ABOVE ITEMS SHALL BE <br />RETURNED FOR CORRECTIONS WITHOUT PROCESSING. <br />10. RESUBMITTED SHOP DRAWINGS SHALL HAVE THE FOLLOWING CHANGES <br />INCORPORATED: FIRST RESUBMISSION TO HAVE LETTER "A" ADDED TO <br />DRAWING <br />A. NUMBER AND ANY CHANGES MARKED ON THE DRAWING MARKED 1 AT <br />EACH ITEM CHANGED. ALL ITEMS TO BE NOTED IN REVISION BOX. <br />B. SUBSEQUENT RESUBMISSION SHALL BEAR CHANGES "B" AND 2 AND 3 <br />ETC. AS IN 11A. <br />11. CONTRACTOR SHALL HAVE SHOP DRAWINGS WHICH HAVE BEEN <br />SATISFACTORILY REVIEWED BY THE ARCHITECT AND/OR ENGINEER AND <br />CONFIRMED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY WORK. <br />12. DETAILER SHALL USE THE SAME STRUCTURAL ELEMENTS NUMBERS IN HIS <br />DETAILS AS THOSE SHOWN ON CONTRACT DRAWINGS. <br />13. SHOP DRAWINGS FOR ALL STRUCTURAL ELEMENTS SHOULD BE <br />SUBMITTED TO MCE WITH A MINIMUM TIME TO BE REVIEWED OF 10 <br />WORKING DAYS. IN CASE OF A LARGE SUBMITTAL OR MORE THAN ONE <br />SUBMITTAL FOR THE SAME PROJECT, AN ADDITIONAL WORKING DAY IS <br />REQUIRED FOR EVERY 5 DRAWINGS/SHEETS OVER 30 DRAWINGS/SHEETS. <br />THE TIME INDICATED ABOVE IS FOR MCE REVIEW ONLY, CONTRACTOR <br />MUST INCLUDE ENOUGH TIME FOR DELIVERY, ARCHITECTURAL REVIEW, <br />AND OWNERS REVIEW AND WORK THIS TIME IN THE PROJECT SCHEDULE <br />AS NEEDED. <br />14. THERE SHALL BE NO DEVIATION FROM THESE CONSTRUCTION <br />DOCUMENTS. IF ANY CHANGES ARE PROPOSED BY THE CONTRACTOR OR <br />THE PROVIDER OF THE SHOP DRAWINGS THEY SHOULD BE CLEARLY <br />INDICATED, SIGNED AND SEALED DRAWINGS AND CALCULATIONS BY A <br />FLORIDA PROFESSIONAL ENGINEER MUST BE PROVIDED. ANY CHANGES <br />WITHOUT PROPER DOCUMENTATION INDICATED ABOVE WILL RESULT IN <br />SOME REVISIONS BY THE ENGINEER OF RECORD AND/OR ARCHITECT. THE <br />COST FOR THESE REVISIONS INCLUDING ENGINEER AND ARCHITECTURAL <br />FEES SHALL BE PAID BY THE CONTRACTOR. <br />DELEGATED DESIGN <br />1. SELECT SCOPE ITEMS IN THE PROJECT ARE CUSTOM DESIGNED AND <br />ENGINEERED, THE ENGINEERING RESPONSIBILITY IS DELEGATED TO <br />THE CONTRACTOR AND RELATED SUBCONTRACTORS. <br />2. CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS <br />AND CALCULATIONS FOR SUCH ELEMENTS DESIGNATED TO BE <br />DESIGNED BY A DELEGATED ENGINEER. <br />3. DELEGATED ENGINEERING WILL ADDRESS ALL LOADING <br />REQUIREMENTS INCLUDING WIND PRESSURES IN ACCORDANCE <br />WITH THE LATEST FLORIDA BUILDING CODE. REFER TO THE <br />COMPONENTS AND CLADDING PRESSURES PROVIDED FOR DESIGN <br />PRESSURES ELEMENTS SHALL BE IN CONFORMANCE WITH. <br />4. DELEGATED ENGINEERED DRAWINGS SHALL DEFINE MATERIAL <br />THICKNESS, SIZING, CONNECTIONS, ETC. OF THE SUBMITTED <br />SYSTEM. <br />5. DELEGATED ENGINEERED DRAWINGS AND CALCULATIONS WILL BE <br />REVIEWED AS PART OF THE SUBMITTAL PROCESS. <br />6. BUILDING COMPONENTS THAT ARE NOT SPECIFIED AS DELEGATED <br />TO OTHER ENGINEERS SHALL BE SUBMITTED WITH APPROPRIATE <br />FLORIDA PRODUCT APPROVAL INFORMATION IN THE SUBMITTAL. <br />WHERE A FLORIDA PRODUCT APPROVAL DOES NOT EXIST FOR A <br />COMPONENT REQUIRING APPROVAL, THE DESIGN SHALL BE <br />DELEGATED TO AN ENGINEER ON THE CONTRACTOR'S TEAM. <br />STRUCTURAL SHEET INDEX <br />Sheet <br />Number <br />Sheet Name <br />S101 <br />GENERAL STRUCTURAL NOTES <br />S102 <br />WIND DESIGN DATA AND LOAD SCHEDULE <br />S201 <br />FOUNDATION PLAN <br />S202 <br />SLAB ON GRADE PLAN <br />S203 <br />2ND FLOOR FRAMING PLAN <br />S204 <br />3RD FLOOR FRAMING PLAN <br />S205 <br />ROOF FRAMING PLAN <br />S301 <br />TYPICAL DETAILS <br />S302 <br />TYPICAL DETAILS <br />S303 <br />TYPICAL DETAILS <br />S304 <br />TYPICAL DETAILS <br />S305 <br />TYPICAL DETAILS <br />S306 <br />TYPICAL DETAILS <br />S401 <br />SECTIONS AND DETAILS <br />S402 <br />SECTIONS AND DETAILS <br />S403 <br />SECTIONS AND DETAILS <br />S404 <br />SECTIONS AND DETAILS <br />TO THE BEST OF OUR KNOWLEDGE INFORMATION AND BELIEF, THESE <br />STRUCTURAL PLANS CONFORM TO AND SATISFY, THE FLORIDA BUILDING <br />CODE 2020 (SEVENTH EDITION), ACI 318-14 AND LOCAL CODES AS APPLICABLE <br />MASTER <br />CONSULTING <br />ail ENGINEERS, INC. <br />STRUCTURAL CONSULTANTS <br />5523 WEST CYPRESS ST., STE.200 <br />TAMPA, FLORIDA 33607-1735 <br />P 1813.287.3600 F 1813.287.3622 <br />www.mcengineers.com <br />THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS THE SOLE PROPERTY <br />OF MASTER CONSULTING ENGINEERS, INC. AND MAY NOT BE REPRODUCED, <br />COPIED, ALTERED OR USED IN ANY WAY WITHOUT THE EXPRESS WRITTEN <br />AUTHORIZATION FROM MASTER CONSULTING ENGINEERS, INC. <br />CA: 8426 PROJ NO. 2049-022 <br />© COPYRIGHT 2016 <br />Furr, <br />Wegman & <br />Banks <br />Architects, P.A. AR0006480 <br />625 EAST ORANGE ST. <br />LAKELAND, FL 33801 <br />E-MAIL: INFO@F W BARCH ITECTS.COM <br />WW W. FW BARC H ITECTS.COM <br />PH. 863.688.1211 <br />®COPYRIGHT 2021 <br />FURR, WEGMAN &BANKS ARCHITECTS, PA <br />THE DESIGN AND CONCEPTS DEPICTED HEREWITH ARE THE SOLE <br />PROPERTY OF FURR, WEGMAN & BANKS ARCHITECTS, PA. <br />NO REPRODUCTION, REVISION OR REUSE Of THIS DRAWING IS <br />AUTHORIIED WITHOUTSPECIFIC WRITTEN PERMISSION. <br />ALL RIGHTS RESERVED. <br />�OOOp�O <br />bob L00 <br />�4go�o� <br />P�°0 <br />a ��•��CEIVS•-.'� <br />F .0`0� <br />oO� <br />81 <br />'*o <br />o o <br />S EOF :441� <br />_O <br />00Q <br />QDBO <br />ROBERT L. BELL, P.E. <br />FL. LIC. No. 74081 <br />J <br />z <br />0 <br />w <br />w <br />0 <br />z <br />0 <br />a <br />U <br />U) <br />w <br />0 <br />z <br />0 <br />U) <br />w <br />w <br />Q <br />0 <br />a <br />N <br />M <br />E0 <br />1,01 <br />ti <br />N <br />O <br />N <br />N <br />00 <br />O <br />LLI <br />Q <br />0 <br />W <br />LU <br />�.- <br />U) <br />O <br />z <br />z <br />w <br />_J <br />Q <br />U <br />w <br />z <br />o <br />V� <br />O <br />J� <br />:D <br />zZ <br />W <br />O <br />J <br />(D M <br />U <br />Q <br />0 L- <br />8 <br />O 1z <br />CA � <br />= ZJ <br />O <br />W <br />0 = <br />Z <br />m Q ; <br />LLI <br />W <br />v <br />v! Q coo N <br />a <br />PROJ MGR: <br />D BY: <br />F <br />JOB NUMBER: <br />21-19 <br />SHEET NUMBER: <br />S101 <br />