AD
<br />ACCESS DOOR
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />AP
<br />ACCESS PANEL
<br />BFF
<br />BELOW FINISHED FLOOR
<br />BOT
<br />BOTTOM
<br />CLG
<br />CEILING
<br />COMB
<br />FIRE STANDPIPE COMBINATION RISER
<br />DI
<br />DUCTILE IRON PIPE
<br />D
<br />DRAIN
<br />DN
<br />DOWN
<br />EL
<br />ELEVATION
<br />EQUIP
<br />EQUIPMENT
<br />FD
<br />FLOOR DRAIN
<br />FDC
<br />FIRE DEPARTMENT CONNECTION
<br />FDV
<br />FIRE DEPARTMENT VALVE
<br />FH
<br />FIRE HYDRANT
<br />FL
<br />FLOOR
<br />FFD
<br />FLOOR FUNNEL DRAIN
<br />F
<br />FIRE MAIN
<br />FS
<br />FLOW SWITCH
<br />FSP
<br />FIRE STANDPIPE RISER
<br />GPM
<br />GALLONS PER MINUTE
<br />MAX
<br />MAXIMUM
<br />MIN
<br />MINIMUM
<br />NC
<br />NORMALLY CLOSED
<br />NIC
<br />NOT IN CONTRACT
<br />NO
<br />NORMALLY OPEN
<br />OS&Y
<br />OUTSIDE SCREW & YOKE
<br />PRV
<br />PRESSURE REDUCING VALVE
<br />SPK.
<br />SPRINKLER
<br />TS
<br />TAMPER SWITCH
<br />TYP
<br />TYPICAL
<br />UON
<br />UNLESS OTHERWISE NOTED
<br />VIF
<br />VERIFY IN FIELD
<br />DRAWING SYMBOLS
<br />_<0- POINT OF INTERFACE BETWEEN CONTRACTORS
<br />FIRE PROTECTION
<br />SYSTEM SUMMARY
<br />OWNER :
<br />LOCATION:
<br />OCCUPANCY:
<br />NUMBER OF FLOORS: THREE (3)
<br />CEILING HEIGHT: SEE ARCHITECTURAL DRAWINGS
<br />APPLICABLE CODES: NFPA 13R / NFPA 20
<br />SYSTEM COVERAGE: _,_ sq.ft.
<br />DESIGN AREA: _,_ sq.ft.
<br />DESIGN DENSITY: SEE FP DESIGN CRITERIA (THIS SHEET)
<br />SPRINKLER RESPONSE: QUICK RESPONSE
<br />FIRE MAIN: 6'
<br />WATER FLOW TEST INFORMATION
<br />STATIC PRESSURE = _ PSI
<br />RESIDUAL PRESSURE _ _ PSI
<br />FLOW = -._ GPM
<br />TEST LOCATION:
<br />TEST TAKEN BY:
<br />TEST DATE:
<br />LEGEND
<br />SPRINKLER HEAD - BRASS UPRIGHT (SEE SCHEDULE)
<br />• SPRINKLER HEAD - WHITE PENDENT (SEE SCHEDULE)
<br />SPRINKLER HEAD - WHITE SIDEWALL 200'F (SEE SCHEDULE)
<br />SPRINKLER HEAD - BRASS SIDEWALL 155-F (SEE SCHEDULE)
<br />NEW FIRE SPRINKLER PIPING
<br />VALVE IN RISER
<br />FLUSHING CONNECTION
<br />DIRECTION OF FLOW
<br />IZ TOP CONNECTION, 45 OR 90 DEG.
<br />BOTTOM CONNECTION, 45 OR 90 DEG.
<br />SIDE CONNECTION
<br />RISE OR DROP IN PIPE
<br />2�P UNION
<br />GATE VALVE
<br />-��i--� CHECK VALVE
<br />--FYI BALL VALVE
<br />I-�r-�� BUTTERFLY VALVE
<br />NOTE:
<br />THEM ARE STANDARD SYMBOLS AND GENERAL NOTES AND MAY NOT
<br />ALL APPEAR ON THE PROJECT DRAWINGS; HOWEVER WHEREVER THE
<br />SYMBOL APPEARS ON THE PROJECT DRAWNGS, TFE ITEM SHALL BE
<br />PROVIDED AND INSTALLED.
<br />FIRE PROTECTION DESIGN
<br />LIGHT HAZARD CRITERIA
<br />Fire Flow Test:
<br />Static pressure - _ psi
<br />Residual Pressure- _ psi
<br />Flow - gpm
<br />Test Date
<br />First floor Retail and Second Thru Eighth Floors
<br />* Fire Protection system to be designed to the Latest NFPA 13R (2019) and AHJ
<br />* Hazard Type: Light hazard
<br />* Sprinkler Head Design Area: 144 sq.ft.
<br />* Sprinkler Head Density: .10 gpm/sq.ft.
<br />* Sprinkler Head Response Type: Quick Response
<br />* System Coverage Area: Most remote 1500 sq.ft.
<br />* Sprinkler Head Temperature Rating: 155 degree F
<br />* All materials to be UL Listed and/or Factory Mutual approved.
<br />* All piping shall be pressure tested at 200 psi for 2 hour as per NFPA 13 (2019)
<br />* Fire sprinkler system to be centrally monitored.
<br />* Provide signed and sealed hydraulic calculations.
<br />FIRE PROTECTION DESIGN
<br />ORDINARY HAZARD CRITERIA
<br />Fire Flow Test:
<br />Static pressure - 60 psi
<br />Residual Pressure- 50 psi
<br />Flow - gpm
<br />Test Date
<br />* Parking Levels and Mechanical Rooms.
<br />* Fire Protection system to be designed to NFPA 13R (2019) and AHJ.
<br />* Hazard Type: Ordinary hazard
<br />* Sprinkler Head Design Area: 120 sq.ft.
<br />* Sprinkler Head Density: .15 gpm/sq.ft.
<br />* Sprinkler Head Response Type: Quick Response
<br />* System Coverage Area: Most remote 1500 sq.ft.
<br />* Sprinkler Head Temperature Rating: 155 degree F
<br />* All materials to be UL Listed and/or Factory Mutual approved.
<br />* All piping shall be pressure tested at 200 psi for 2 hour as per NFPA 13R (2019)
<br />* Fire sprinkler system to be centrally monitored.
<br />* Provide signed and sealed hydraulic calculations.
<br />PIPE SIZE
<br />A
<br />B
<br />C
<br />1.
<br />V-O' MAX.
<br />12'-0" MAX,
<br />NO MINIMUM
<br />1-1/4"
<br />1'-O" MAX.
<br />12'-0" MAX,
<br />NO MINIMUM
<br />1-1 /2"-$"
<br />1'-0' MAX.
<br />15'-0" MAX.
<br />NO MINIMUM
<br />NOTE
<br />1. ALL ARMOVERS GREATER THAN 12" ARE TO HAVE A HANGER. THE HANGER CLOSEST TO
<br />THE SPRINKLER SHALL BE OF THE TYPE TO PREVENT UPWARD MOVEMENT
<br />A
<br />lu LHANGER RING SPRINKLER HEAD
<br />* MAXIMUM HANGER SPACING FOR THREADED UGHTWALL STEEL PIPE IS 12'-0"
<br />FOR ALL PIPE SIZES
<br />'STEEL PIPE HANGER SPACING SCHEDULE
<br />NOT TO SCALE
<br />FIRE PROTECTION SPECIFICATIONS
<br />1.0 PIPE FITTINGS AND VALVES
<br />A. 3" AND SMALLER: BLAZEMASTER 2000 CPVC FOR FIRE SPRINKLER USE.
<br />B. 4" AND LARGER SHALL BE SCHEDULE 10 BLACK STEEL ROLL GROOVED WITH GROOVED COUPLINGS
<br />AND FITTINGS, MECHANICAL TEES AND WELDED OUTLETS.
<br />C. DRAIN PIPING SHALL BE SCHEDULE 40 WITH THREADED CAST IRON BLACK FITTINGS, NFPA 13R
<br />SPECIFIED WALL THICKNESS FOR 2-1/2" THRU 4" SIZE.
<br />1.1 CAST IRON THREADED FLANGES
<br />ASME B16.4, CLASS 125, RAISED GROUND FACE, BOLT HOLES SPOT FACED.
<br />1.2 CAST IRON THREADED FITTINGS
<br />ASME B16.4, CLASS 125, STANDARD PATTERN, WITH THREADS ACCORDING TO ASME B1.20.1, 175
<br />PSI RATED.
<br />1.3 MALLEABLE IRON THREADED FITTINGS
<br />ASME B16.3, CLASS 150, STANDARD PATTERN, WITH THREADS ACCORDING TO ASME B1.20.1.
<br />1.4 STEEL FITTINGS
<br />ASTM A 234/ A 234M, SEAMLESS OR WELDED; ASME B16.9, BUTTWELDING; OR ASME B16.11,
<br />SOCKET WELDING TYPE FOR WELDED JOINTS
<br />1.5 GROOVED END FITTINGS FOR STEEL PIPE
<br />UL LISTED AND FM APPROVED ASTM A 536, GRADE 65-45-152 DUCTILE IRON OR ASTM A 47
<br />GRADE 32510 MALLEABLE IRON, WITH GROOVES OR SHOULDERS DESIGNED TO ACCEPT GROOVED
<br />COUPLINGS.
<br />1.6 FLANGED JOINTS FOR DUCTILE IRON PIPE AND DUCTILE IRON OR CAST IRON FITTINGS
<br />AWWA C115 DUCTILE IRON OR GRAY IRON PIPE FLANGES, RUBBER GASKETS, AND HIGH STRENGTH
<br />STEEL BOLTS AND NUTS.
<br />1.7 COUPLINGS FOR GROOVED END STEEL PIPE AND GROOVED END FERROUS FITTINGS
<br />UL 213, AWWA C606, ASTM A 536 DUCTILE IRON OR ASTM A 47 MALLEABLE IRON HOUSING,
<br />WITH ENAMEL FINISH. INCLUDE SYNTHETIC RUBBER GASKET WITH CENTRAL CAVITY, PRESSURE
<br />RESPONSIVE DESIGN, ASTM A 183 CARBON STEEL BOLTS AND NUTS TO SECURE GROOVED PIPE
<br />AND FITTINGS.
<br />1.8 GENERAL
<br />UL LISTED AND/OR FM APPROVED SERVICE VALVES WITH 175 PSIG NON -SHOCK MINIMUM
<br />WORKING PRESSURE RATING. GATE VALVES: UL 262, CAST BRONZE, THREADED ENDS, SOLID
<br />WEDGE, OUTSIDE SCREW AND YOKE, RISING STEM. PROVIDE INDICATING (BUTTERFLY OR BALL)
<br />VALVES TYPE, BRONZE BODY WITH THREADED ENDS, AND INTEGRAL INDICATING DEVICE, INDICATOR
<br />SHALL BE VISUAL AND ELECTRICAL 115 VOLTS A.C., PRE -WIRED 2 CIRCUIT, SUPERVISORY SWITCH.
<br />2.0 SPRINKLERS
<br />"
<br />- GLASS BULB SPRINKLER HEADS WITH 1 2 NOMINAL
<br />PROVIDE AUTOMATIC HEAT RESPONSIVE K /
<br />ORIFICE, 5.56 "K" FACTOR 155'F TEMPERATURE RATING, INSTALL SPRINKLERS IN A UNIFORM,
<br />CONSISTENT MANNER IN ORDER TO LINE UP EACH AREA.
<br />3.0 SPRINKLER CABINETS
<br />FINISHED STEEL CABINET AND HINGED COVER, WITH 6 SPARE SPRINKLERS PLUS SPRINKLER
<br />WRENCH, SUITABLE FOR WALL MOUNTING.
<br />4.0 ALARM DEVICES
<br />COORDINATE WITH ELECTRICAL (OR FIRE ALARM) CONTRACTOR TO PROVIDE CONNECTIONS TO FIRE
<br />ALARM SYSTEM AS REQUIRED.
<br />5.0 PIPING INSTALLATIONS
<br />DEVIATIONS FROM APPROVED "PERMIT PLANS" FOR SPRINKLER PIPING REQUIRE WRITTEN
<br />APPROVAL FROM AUTHORITY WITH JURISDICTION. INSTALL UNION OR FLANGE ADJACENT TO EACH
<br />VALVE. INSTALL HANGER AND SUPPORT SPACING AND LOCATIONS FOR STEEL PIPING JOINED
<br />WITH GROOVED MECHANICAL COUPLINGS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS.
<br />FOR RIGID SYSTEMS PER NFPA 13R.
<br />6.0 FIELD QUALITY CONTROL
<br />FLUSH, TEST AND INSPECT SPRINKLER PIPING SYSTEMS ACCORDING TO NFPA 13 CHAPTER
<br />"SYSTEM ACCEPTANCE". REPORT TEST RESULTS PROMPTLY AND IN WRITING TO ARCHITECT AND
<br />TO THE AUTHORITY HAVING JURISDICTION. CLEANING: CLEAN DIRT AND DEBRIS FROM
<br />SPRINKLERS. REPLACE SPRINKLERS HAVING PAINT OTHER THAN FACTORY FINISH WITH NEW
<br />SPRINKLERS. CLEAN AND REUSE OF PAINTED SPRINKLERS IS PROHIBITED.
<br />7.0 SPRINKLER SYSTEM BASIS OF DESIGN
<br />ITEM DESIGN
<br />CLASSIFICATION COORDINATE WITH ARCHITECTURAL DRAWING AND CLASSIFY
<br />AREAS PER NFPA
<br />TYPE WET PIPE SPRINKLER SYSTEM
<br />SPRINKLER HEAD (SEE SCHEDULE)
<br />MANUFACTURER/MODEL
<br />TEMPERATURE RATING
<br />STATIC PRESSURE
<br />RESIDUAL PRESSURE/FLOW
<br />FIRE DEPARTMENT CONNECTION
<br />(SEE SCHEDULE)
<br />CONTRACTOR TO OBTAIN INFORMATION
<br />CONTRACTOR TO OBTAIN INFORMATION
<br />FREE STANDING 'STORZ' OR FDC COORDINATION WITH AHJ
<br />NOTES:
<br />1. SYSTEM DESIGN SHALL BE HYDRAULICALLY CALCULATED PER NFPA-13R.
<br />2. PROVIDE 200*17 TEMPERATURE SPRINKLER HEADS IN THE MECHANICAL / ELECTRICAL ROOMS.
<br />3. COORDINATE CEILING MOUNTED SPRINKLER HEADS WITH OTHER DEVICES (LIGHTS, DIFFUSERS,
<br />ACCESS PANELS, ETC.) SEE ARCHITECTURAL CEILING PLANS FOR LOCATIONS OF ALL DEVICES.
<br />4. ALL MATERIALS AND EQUIPMENT SHALL UL AND/OR FACTORY MUTUAL APPROVED WHERE
<br />APPLICABLE.
<br />FIRE SPRINKLER HEAD SCHEDULE
<br />SYMBOL
<br />NAME
<br />METAL FINISH
<br />TEMPERATURE
<br />K-FACTOR
<br />N.P.T.
<br />SIN.
<br />MANUFACTURER
<br />MODEL
<br />O
<br />UPRIGHT
<br />BRASS
<br />155' F
<br />5.6
<br />1 /2"
<br />VK300
<br />VIKING
<br />M
<br />PENDENT
<br />WHITE
<br />155' F
<br />5.6
<br />1/2"
<br />VK302
<br />VIKING
<br />M
<br />CONCEALED
<br />PENDENT
<br />WHITE
<br />155' F
<br />5.6
<br />1/2"
<br />-
<br />VIKING
<br />M
<br />DRAWING INDEX
<br />FIRE PROTECTION
<br />FP000
<br />ABBREVIATIONS, LEGENDS, GENERAL NOTES AND FIXTURE SCHEDULE
<br />FP101
<br />FIRE PROTECTION "CRITERIA" FIRST FLOOR PLAN
<br />FP102
<br />FIRE PROTECTION "CRITERIA" SECOND FLOOR PLAN
<br />FP103
<br />FIRE PROTECTION "CRITERIA' THIRD FLOOR PLAN
<br />FP401
<br />FIRE PROTECTION DETAILS
<br />FIRE PROTECTION GENERAL NOTES
<br />1. FIRE PROTECTION CONTRACTOR SHALL SUBMIT SIGNED/SEALED WORKING DRAWINGS FOR ENGINEER
<br />REVIEW AND COMMENT PRIOR TO SUBMITTING TO BUILDING DEPARTMENT/FIRE MARSHAL FOR PERMIT REVIEW.
<br />FP CONTRACTORS DRAWINGS SHALL INCLUDE:
<br />1. DETAILED DRAWINGS SHOWING LAYOUT OF HEADS, PIPING, VALVES AND LOCATION OF ALL ACCESSORIES.
<br />2. HYDRAULIC CALCULATIONS IN CONFORMANCE WITH NFPA 13R.
<br />3. SPRINKLER HEAD TYPE AND MODEL NUMBERS (NO SIDEWALL HEADS WILL BE ALLOWED).
<br />4. FIRE DEPARTMENT CONNECTIONS.
<br />5. FIRESTOPPING.
<br />2. THE FIRE PROECTION CONTRACTOR SHALL BE LICENSED IN THE STATE OF FLORIDA AS A FIRE PROTECTION,
<br />REGULARLY ENGAGED IN THE INSTALLATION OF AUTOMATIC FIRE SPRINKLER SYSTEMS AND EQUIPMENT.
<br />THE SYSTEM SHALL BE INSTALLED BY AN EXPERIENCED FIRM UTILIZING THAT FIRMS REGULARLY EMPLOYED
<br />AND FULL TIME PERSONNEL WHO ARE CERTIFIED IN THE INSTALLATION OF AUTOMATIC FIRE PROTECTION
<br />SYSTEMS IN STRICT ACCORDANCE WITH NFPA STANDARDS.
<br />3. FIRE PROTECTION WORK SHALL BE DESIGNED, INSTALLED, AND TESTED IN ACCORDANCE WITH
<br />NFPA 13R (2019), AND NFPA 20 (2019) AS ADOPTED BY THE AUTHORITY HAVING JURISDICTION.
<br />4. INCLUDE ANY INCIDENTAL APPARATUS, APPLIANCES, MATERIAL LABOR AND SERVICES NECESSARY
<br />TO MAKE NEW WORK COMPLETE IN ALL RESPECTS AND FULLY READY FOR OPERATION.
<br />5. MAKE SUCH OFFSETS AND DEVIATIONS AS MAY BE NECESSARY TO FIT THE ACTUAL SPACE CONDITIONS.
<br />6. INSTALLER SHALL COORDINATE AT SITE WITH ALL PLUMBING, HVAC, AND ELECTRICAL WORK SO AS
<br />TO NOT CONFLICT IN LOCATION WITH OTHER WORK UNDER THIS CONTRACT. CONTRACTOR SHALL
<br />ADJUST PIPE ROUTING AS NECESSARY TO AVOID CONFLICTS WITH DUCTWORK, EQUIPMENT, LIGHTING, ETC.
<br />7. INSTALLER SHALL NOT CUT ANY STRUCTURAL MEMBERS WITHOUT FIRST SECURING WRITTEN APPROVAL
<br />FROM THE ARCHITECT AND STRUCTURAL ENGINEER.
<br />8. IN GEOGRAPHICAL LOCATIONS SUBJECT TO TEMPERATURES BELOW 40'F, PROVIDE PROTECTION FOR
<br />ALL EXPOSED FIRE PROTECTION PIPING IN ACCORDANCE WITH NFPA 13R (2016).
<br />9. ALL FIRE DEPARTMENT CONNECTIONS SHALL HAVE AN AUTOMATIC BALL DRIP.
<br />10. PROVIDE TAMPER SWITCHES ON ALL VALVES THAT CAN SHUT OFF FLOW IN MAINS OR BRANCHES.
<br />CHAINS AND LOCKS IN LIEU OF TAMPER SWITCHES MAY BE USED AT OUTDOOR BACK FLOW
<br />PREVENTERS ONLY IF APPROVED BY THE AUTHORITY HAVING JURISDICTION.
<br />11. CONTRACTOR SHALL ARRANGE FOR, OBTAIN AND BEAR THE COST OF NECESSARY PERMITS, BONDS,
<br />AND FEES.
<br />12. ALL MATERIALS SHALL BE U.L LISTED AND BEAR THE U.L. LABEL
<br />13. CONTRACTOR SHALL PROVIDE A MIMINUM OF A 10 P.S.I. SAFTEY MARGIN FOR MOST REMOTE LIGHT
<br />AND ORDINARY HAZARD HYDRAULIC CALCULATIONS.
<br />14. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES, PENETRATIONS FOR PIPES, CONDUITS, OR OTHER
<br />PURPOSES THROUGH ASSEMBLIES (FLOORS, ROOF, WALLS, PARTITIONS, ETC.) WITH A REQUIRED
<br />FIRE RESISTANCE RATING FIRE STOP MATERIAL SHALL BE UL LISTED AND INSTALLED IN STRICT
<br />ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS TO MEET OR EXCEED THE FIRE RATING OF
<br />THE PENETRATED ASSEMBLY.
<br />15. BEFORE SHUTTING OFF ANY SECTION OF THE FIRE PROTECTION SYSTEM TO MAKE ADJUSTMENTS
<br />OR ADDITIONAL CONNECTIONS, COORDINATE WITH THE OWNER AND NOTIFY THE AUTHORITY
<br />HAVING JURISDICTION. PLAN THE WORK CAREFULLY AND ASSEMBLE ALL MATERIALS TO ENABLE
<br />COMPLETION IN THE SHORTEST POSSIBLE TIME. WORK SHALL BE USED TO COMPLETION WITHOUT
<br />INTERRUPTION, AND PROTECTION SHALL BE RESTORED AS PROMPTLY AS POSSIBLE.
<br />16. WHERE ELECTRICAL PANELS ARE LOCATED, PROVIDE DEFLECTORS ON ELECTRICAL EQUIPMENT TO PREVENT
<br />WETTING PANELS. SPRINKLER PIPING SHALL NOT BE INSTALLED DIRECTLY ABOVE ELECTRIC PANELS.
<br />17. PROVIDE FLUSHING CONNECTION AT END OF SPRINKLER SYSTEM WITH ACCESS PANEL
<br />ALL SPRINKLER PIPING THAT REQUIRES CHANGE IN ELEVATION DUE TO COORDINATION ROUTING OF
<br />PIPING SHALL HAVE FLUSH CONNECTION AT ALL LOWER ELEVATION. THE SPRINKLER SYSTEM SHALL
<br />BE INSTALLED WITH COMPLETE DRAINABLE SYSTEM.
<br />18. PROVIDE UPRIGHT SPRINKLER HEADS UNDER ALL EXPOSED DUCTWORK/OBSTRUCTION 48" WIDE OR
<br />LARGER, PER NFPA 13R OR AS REQUIRED TO PROVIDE COVERAGE.
<br />19. ALL SPRINKLER HEADS SHALL BE U.L LISTED AND INSTALLED IN ACCORDANCE WITH THEIR
<br />LISTING REQUIREMENTS. ALL ESCUTCHEONS AND ACCESSORIES SHALL BE METAL.
<br />20. ALL WORK IS TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1)
<br />YEAR FROM DATE OF FINAL ACCEPTANCE. ALL DEFECTS WHICH DEVELOP OR ARE DISCOVERED
<br />WITHIN THIS PERIOD SHALL BE REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE
<br />OWNER AT NO ADDITIONAL COST TO THE OWNER.
<br />21. UPON COMPLETION OF THE WORK UNDER THIS CONTRACT, THE CONTRACTOR SHALL REMOVE ALL
<br />TOOLS, APPLIANCES, SURPLUS MATERIALS, AND SCRAP. ALL IDENTIFIED EXISTING EQUIPMENT TO
<br />BE REMOVED SHALL BE TURNED OVER TO THE OWNER.
<br />22. PENDENT MOUNTED SPRINKLER HEADS SHALL BE ALIGNED WITHIN NORMAL FABRICATION AND
<br />INSTALLATION TOLERANCES AND WILL BE CENTERED IN CEILING AREAS.
<br />23. THE CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES IN ORDER TO AVOID CONFLICTS.
<br />24. COORDINATE EXACT LOCATION OF SPRINKLERS AND PIPING WITH CEILING, ELECTRICAL, MECHANICAL,
<br />AND STRUCTURAL ELEMENTS OF BUILDING. MAKE MODIFICATIONS WITHOUT ADDITIONAL COST TO THE
<br />OWNER.
<br />25. PROVIDE ALL HANGERS INCLUDING TRAPEZE HANGERS AS REQUIRED TO COMPLY WITH NFPA 13R.
<br />26. TAMPER SWITCHES AND FLOW SWITCHES TO BE PROVIDED AND INSTALLED BY FIRE PROTECTION
<br />CONTRACTOR AND CONNECTED BY FIRE ALARM CONTRACTOR. COORDINATE TO VERIFY COMPATIBILITY
<br />OF SWITCHES AND LOCATIONS.
<br />27. PROVIDE ALL DRAINS AS REQUIRED BY NFPA 13R.
<br />28. EQUIP ALL GATE AND BUTTERFLY VALVES WITH LOCKING DEVICES AND TAMPER SWITCHES IF REQUIRED
<br />BY AUTHORITY HAVING JURISDICTION.
<br />29. INSTALL FIRE DEPARTMENT CONNECTION AND CHECK VALVE AFTER BACKFLOW PREVENTER.
<br />30. SEE CIVIL DRAWINGS FOR LOCATION OF FIRE MAINS. SHOWN HERE TO GIVE POINT OF SERVICE
<br />AND HYDRAULIC REFERENCE POINTS. FIRE PROTECTION CONTRACTOR TO COORDINATE LOCATION
<br />OF MAINS AND STUB -UPS FOR SPRINKLER RISERS WITH ALL OTHER CONTRACTORS AND MAKE
<br />ADJUSTMENTS AS NECESSARY TO PROVIDE COMPLETE SYSTEM AT NO ADDITIONAL COST TO THE
<br />OWNER.
<br />31. ALL SPRINKLER HEADS SHALL BE WHITE QUICK RESPONSE TYPE.
<br />32. CONTRACTOR SHALL PERFORM FLOW TEST AT ALL PROJECT SITE HYDRANTS.
<br />33. PROVIDE CONCEALED PENDANT SPRINKLER HEADS AND ALL "COMMON AREA" LOCATIONS.
<br />Furr,
<br />Wegman &
<br />Banks
<br />Architects, P.A. AR0006480
<br />625 EAST ORANGE ST.
<br />LAKELAND, FL 33801
<br />E-MAIL: INFO@FWBARCHITECTS.COM
<br />W W W.FW BARCHITECTS.COM
<br />PH. 863.688.1211
<br />® COPYRIGHT 202T
<br />FURR, WEGMAN & BANKS ARCHITECTS, PA
<br />THE DESIGN AND CONCEPTS DEPICTED HEREWITH ARE THE SOLE
<br />PROPERTY OF PURR, WEGMAN & BANKS ARCHITECTS, PA.
<br />NO REPRODUCTION. REVISION OR REUSE OF THIS DRAWING IS
<br />AUTHORIZED WITHOUT SPECIFIC WRITTEN PERMISSION.
<br />ALL .
<br />N01SS�'%,,
<br />04-
<br />30 31V1s
<br />-
<br />N
<br />:•�6 cg8 �•�
<br />�a 3��J
<br />' �
<br />S N •'' .�
<br />� .
<br />W411N�
<br />SCOEf;T�L5�\P.E.
<br />FL. LIC. 86539 EXP. 02-28-2023
<br />U
<br />A
<br />.: € iss �I.Ais
<br />r a�oN�
<br />� YZOM7N
<br />CN q IL Z'
<br />� s
<br />z
<br />Z
<br />O
<br />w
<br />w
<br />x
<br />I-
<br />I
<br />z
<br />O
<br />H
<br />a
<br />0
<br />W
<br />w
<br />0
<br />Z
<br />O
<br />w
<br />w
<br />Q
<br />0
<br />ar-
<br />N
<br />M
<br />"t
<br />LO
<br />CO
<br />tL
<br />(V
<br />O
<br />N
<br />U)
<br />ti
<br />W
<br />N
<br />co
<br />F_
<br />0
<br />LU
<br />Z
<br />Q
<br />J
<br />W
<br />Z
<br />rWn
<br />V
<br />Z
<br />Q
<br />Z
<br />U
<br />W
<br />Z
<br />0
<br />(D
<br />0
<br />Z
<br />Q
<br />Z
<br />00
<br />0
<br />&m
<br />~
<br />m
<br />m
<br />zZ
<br />Q
<br />�
<br />U)C
<br />o
<br />M
<br />U
<br />0
<br />O G ��
<br />O
<br />Z
<br />I- rj)-j
<br />W
<br />Z_j
<br />MI
<br />T.-O
<br />W
<br />> CL 0)a
<br />=
<br />J
<br />U) Q CD N
<br />a
<br />PROJ MGR:
<br />CKD BY:
<br />RR/SJ
<br />SN
<br />JOB NUMBER:
<br />21-19
<br />SHEET NUMBER:
<br />F.POO 0
<br />Z:\Furr Wegman & Banks Architects\211036 - Healthier Stay Pasco Dormitory\Design\211036 FPOOO.dwg, August 27, 2021 3:57 PM, SHAWN JEFFREY,