My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6439 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6439 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 2:58:28 PM
Creation date
2/18/2025 3:35:52 PM
Metadata
Fields
Template:
Building Plans
Street #
6439
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS GENERAL NOTES VERSION CHANGES INDEX OF DRAWINGS <br />ABV -ABOVE MLDG - MOULDING THE FOLLOWING TECHNICAL CODES SHALL APPLY: VERSION DESCRIPTION OF CHANGES SHT NO: TITLE <br />AFF - ABOVE FINISH FLOOR MNT - MOUNT OR MOUNTING 1.0 PLAN REVISIONS CS COVER SHEET M <br />AHU - AIR HANDLER UNIT MO - MASONRY OPENING Al FOUNDATION PLAN N <br />A/C - AIR CONDITIONING MUNT - MUNTINS 2020 FLORIDA BUILDING CODE RESIDENTIAL, PLUMBING, MECHANICAL, FUEL GAS, 2.0 PLAN REVISIONS N <br />ALUM - ALUMINUM # -NUMBER ENERGY EFFICIENCY, ACCESSIBILITY, AND NFPA 70 NATIONAL ELECTRICAL CODES 2017 A2 1ST AND 2ND FLOOR PLAN A 00 <br />Q <br />AT - ALUMINUM THRESHOLD OC - ON CENTER 3.0 TRUSS CONNECTOR REVISION A3 STAIR DETAILS i <br />AB - ANCHOR BOLT OGD - OVERHEAD GARAGE DOOR 2020 FBC PLUMBING RESIDENTIAL SECTION 604 A4 FRAMING PLANS A <br />4.0 FLORIDA BUILDING CODE 7TH EDITION (2020) UPDATE A5 EXTERIOR ELEVATIONS &ROOF PLAN - - �,ay a <br />AVG -AVERAGE OPNG -OPENING 1. TANK TYPE WATER CLOSET VOLUME A6.1 1ST FLOOR ELECTRICAL PLAN o' � ' ;�/ <br />BFE - BASE FLOOD ELEVATION OPP - OPPOSITE 1.6 GALLONS 5.0 ADDING K, L & M ELEVATIONS y Lo <br />BM -BEAM OPT - OPTIONAL A6.2 2ND FLOOR ELECTRICAL PLAN p, <br />BLK -BLOCK OH - OVER HANG 6.0 ADDED SHEETS WP2.0 AND WP2.1 TO SHEET INDEX SNO STRUCTURAL NOTES ' a M <br />2. WATER - FLOW RATE. U. , I ,,, 4 Q <br />BLDG -BUILDING OH CABS- OVERHEAD CABS SN1 STRUCTURAL NOTES <br />PUBLIC FACILITIES LAV 0.5 G.P.M. u. . z <br />BRD -BOARD PNT - PAINT FINISH o <br />S3 FOUNDATION DETAILS �. ' W w <br />BRG - BEARING PTD - PAINTED PRIVATE FACILITIES LAV 2.2 G.P.M. C�' �;, r� � <br />BTM - BOTTOM PED -PEDESTAL SHOWER HEADS 2.5 G.P.M. S4 FRAME WALL DETAILS �j, + ¢ _ <br />BUC - BUILT UP COLUMN PERF -PERFORATED S5 STRUCTURAL DETAILS t- �4,b , ` O <br />S6 WALL SECTION DETAILS 4',• - - _ _ <br />CAB - CABINET PLT -PLATE 3. ALL PLUMBING WATER LINES SS RETRO FIT DETAILS <br />CD - CONSTRUCTION DOCUMENTS PLYWD - PLYWOOD TO BE CPVC ` '�,,•,1 <br />CLG - CEILING PKT -POCKET ST STAIR DETAILS ., °. w <br />CLG HT - CEILING HEIGHT LB -POUND VTR LOCATIONS ARE APPROXIMATE AND MAY CHANGE DUE TO S11 PRECAST DETAILS w �� W <br />CEMT - CEMENTITIOUS PSF - POUNDS PER SQUARE FOOT JOBSITE CONDITIONS S12 PRECAST DETAILS Q <br />CL - CENTERLINE PSI - POUNDS PER SQUARE <br />PA 1.0 PRODUCT APPROVAL <br />COL - COLUMN PT - PRESSURE TREATED THE FOLLOWING SHALL COMPLY WITH THE 2020 FBC RESIDENTIAL PA 1.1 PRODUCT APPROVAL <br />CONC -CONCRETE PB - PUSH BUTTON CODE PA 1.2 PRODUCT APPROVAL <br />CMU - CONCRETE MASONRY UNIT REF - REFRIGERATOR PA 1.3 PRODUCT APPROVAL <br />CONST - CONSTRUCT OR CONSTRUCTION RECP -RECEPTACLE ❑ PORCHES AND BALCONIES N N L E <br />CONT - CONTINUOUS OR CONTINUES REINF - REINFORCING CHAP. 3 PA 1.4 PRODUCT APPROVAL > 0 o <br />CTR -CENTER REQD - REQUIRED PA 1.5 PRODUCT APPROVAL p m N m <br />CJ - CONTROL JOINT R/A - RETURN AIR ❑ HANDRAILS - CHAP. 3 SH 1.0 HURRICANE SHUTTERS } o Y) � M <br />DP - DEEP OR DEPTH RO - ROUGH OPENING SH 1.1 HURRICANE SHUTTERS to V -0 - M <br />DTL - DETAIL RS - ROUGH SAWN ❑ GUARDRAILS - CHAP. 3 SH 1.2 HURRICANE SHUTTERS E t <br />DIA - DIAMETER SC - SOLID CORE 0 <br />SH 1.3 HURRICANE SHUTTERS <br />DIM -DIMENSION SCP -SCUPPER ❑ STAIRS - CHAP. 3 SH 1 A HURRICANE SHUTTERS U ° < <br />DISCON - DISCONNECT SCRN -SCREEN SH 1.5 HURRICANE SHUTTERS ,N w aN <br />DW - DISHWASHER SIM -SIMILAR CHIMNEY & FIREPLACE WP 1.0 WATERPROOFING DETAILS L• o E � <br />DR -DOOR SHLVS -SHELVES ❑CHAP. 10 WP 2.0 WATERPROOFING DETAILS 70 0 ^ a <br />DBL - DOUBLE S/R - SHELF & ROD <br />DWG - DRAWING SH - SINGLE HUNG WINDOW WP 2.1 WATERPROOFING DETAILS <br />EA -EACH SGD - SLIDING GLASS DOOR ❑ EGRESS WINDOWS <br />ELEC - ELECTRICAL SPECS - SPECIFICATIONS CHAP. 3 <br />ELEV - ELEVATOR SQ FT - SQUARE FEET <br />EQ -EQUAL SQ IN - SQUARE INCH 5. ALL OPENINGS SHALL COMPLY WITH 2O20 FBC RESIDENTIAL WIND LOADS AS STATED <br />EQUP - EQUIPMENT STD -STANDARD BELOW. ATTACHMENTS OF WINDOWS, DOORS, SLIDING GLASS DOORS AND O.H. <br />EXP JT - EXPANSION JOINT STL -STEEL GARAGE DOORS ARE TO DELEGATED THE MANUFACTURER OF THESE ITEMS. THE <br />EXT - EXTERIOR STRUCT -STRUCTURAL MANUFACTURER OF THESE ITEMS SHALL SUBMIT ATTACHMENTS FOR SITE <br />FIN FLR - FINISHED FLOOR TEMP -TEMPERED INSTALLATION. <br />FIN - FIN THK - THICK OR THICKNESS <br />EW - EACH WAY TB - TOWEL BAR SEE ATTACHED SPECIFICATION SHEETS FOR MANUFACTURERS DESIGN CRITERIA <br />FG - FIXED GLASS TOC - TOP OF CONCRETE AND INSTALLATION METHODS FOR WINDOWS, DOORS, SLIDING GLASS DOORS, <br />FD - FLOOR DRAIN TOM - TOP OF MASONRY OVERHEAD GARAGE DOORS, AND ROOFING. <br />FE - FIRE EXTINGUISHER TOP - TOP OF PLATE <br />FLR -FLOOR TP - TOILET PAPER HOLDER <br />FLOUR -FLUORESCENT TYP - TYPICAL 6. ALL DOORS INTERIOR & EXTERIOR ARE 6'-8" UNLESS OTHERWISE NOTED ALL <br />FTG - FOOTING UNO - UNLESS NOTED OTHERWISE SHOWER ENCLOSURES TO BE TEMPERED GLASS LU <br />FR DR - FRENCH DOOR VAC -VACUUM LU L� w < J � g o z <br />GALV - GALVANIZED VAL - VALANCE 7. ALL WINDOWS WITHIN 24" OF DOORS (INTERIOR & EXTERIOR) AND WITHIN 18" OF FLR C7 W o 2 ¢ o a a Y o ° _o <br />I- aw0�OZO�oommZ� U <br />GA -GAUGE VERT - VERTICAL Q U ¢ a R _j W X o �' <br />CL <br />TO BE TEMPERED GLASS. (SECTION R308) Q CY CO o Z o- o o m o z <br />GB -GRAB BAR VIF -VERIFY IN FIELD � _ <br />GFI / GFCI- GROUND FAULT CIRCUIT INTERRUPTOR VTR - VENT THROUGH ROOF DIMENSIONING: O ¢ ¢ o w � ° z w z O w Ov o a. <br />Uj <br />GWB - GYPSUM WALL BOARD WC - WATER CLOSET O Z ¢ o ¢ o ~ o o <br />GYPBRD - GYPSUM BOARD WH - WATER HEATER A. DIMENSIONS INDICATED ARE TO: <br />HD -HEAD WL - WIND LOAD A.1. CMU WALL: OUTSIDE FACE OF WALL <br />HVAC - HEATING, VENTILATING, AIR CONDITIONING WP -WEATHERPROOF A.2. INTERIOR FRAMED WALLS: PLAN WEST (OR PLAN NORTH) FROM FACE OF <br />HT - HEIGHT WWM - WELDED WIRE MESH CORE -STUD <br />HB - HOSE BIB W - WIDE OR WIDTH A.2.1. DIMENSIONS ARE NOT FROM ELEMENTS ATTACHED TO CORE STUD - I.E. O <br />HC -HANDICAP WDW -WINDOW FURRING\ <br />O <br />INSUL - INSULATION W/ - WITH A.3. EXTERIOR FRAMED WALLS: TO OUTSIDE FACE OF STRUCTURAL CORE -STUD z CV <br />INT - INTERIOR WD - WOOD W <br />LVL -LAMINATED VENEER LUMBERA.4. WINDOW OPENINGS: 0� <br />A.4.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING <br />LT - LAUNDRY TUB S2 = ti <br />LGT - LIGHT A.4.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING <br />MAX - MAXIMUM A.5. DOOR OPENINGS: <br />MATL - MATERIAL A.5.1. CMU WALLS: TO LEFT SIDE OF ROUGH OPENING M O <br />MFR -MANUFACTURER A.5.2. EXTERIOR FRAMED WALLS: TO CENTER OF OPENING (n Co if <br />MECH - MECHANICAL A.5.3. INTERIOR FRAMED WALLS: ADJACENT TO SIDE WALL: 5" RETURN MEASURED J <br />MTL - METAL FROM THE FINISH FACE OF ADJACENT WALL TO INTERIOR FACE OF DOOR W V <br />FRAME - <br />MC - MEDICINE CABINET <br />MIN -MINIMUM A.5.4. INTERIOR FRAMED WALLS: AWAY FROM SIDE WALLS: DIMENSIONED TO CENTER C,rj <br />OF DOOR Q- r <br />A.6. SPECIAL AND CODE REQUIRED CLEARANCES - AS INDICATED ON PLANS OR FINISH Z U O <br />SURFACE TO FINISH SURFACE <br />SYMBOL LEGEND. B. ALIGNMENT OF WALLS AND FINIISHES AS SCHEDUDE FINISH FOR LED SHALL BE R SHOWER z� <br />BE STRAIGHT, TRUE AND <br />(� PLUMB. W J O <br />I I = STAIR CALL OUTHEIGHT OF q SHEET NUMBER STEP DOWN C. THE PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: O CO <br />INT ELEV NUMBER C.1. CODE MINIMUM - MAXIMUM DIMENSIONS AND CLEARANCES ' d' <br />CFOOTING CALL OUT - STEP DOWN ARROW SHOWS C.2. LOAD BEARING CONCRETE MASONRY UNIT WALLS SEE FOOTING SCHEDULE CALLOUT DIRECTION OF VIEW C.3. FRAMED WALLS EXTERIOR <br />ARROW SHOWS INTERIOR ELEVATION CA. FRAMED WALLS INTERIOR <br />= KEYNOTE CALL OUT l DIRECTION OF VIEW MARKER C.5. DOORS AND WINDOWSJULZ 1 23 <br />ELEV NUMBER D. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB - <br />A9 ARROW SHOWS UNLESS OTHERWISE NOTED <br />PRE -CAST LINTEL CALL SHEET NUMBER DIRECTION OF CUT E. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE <br />= OUT - SEE LENTEL EXTERIOR 1 OF MATERIAL AT THE DIMENSION POINT - UNLESS OTHERWISE NOTED <br />SCHEDULE ELEVATION MARKER Al SECTION NUMBER F. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF THE e i <br />1 <--ELEV NUMBER SHEET NUMBER STRUCTURAL MATERIAL ABOVE AS SCHEDULED <br />G. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, Virtual Revie v As ist, Inc. <br />LEDGER CALL OUT - SEE ans Review com P ete a d aRP y <br />o e <br />SHEET NUMBER CLEARANCE AND DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND <br />LEDGER SCHEDULE 4 A15 ror m � <br />LOCATION OF CUT COMPONENTS - DIMENSIONS SHALL NOT BE DETERMINED BY SCALING THE pliance with th 20 0 C t di ion <br />< -ARROW SHOWS DRAWINGS. <br />DIRECTION OF VIEW y bra Anne <br />3 <br />MULTI VIEW INTERIOR SECTION <br />ELEVATION MARKER MARKER O o o c� M <br />Lo <br />N N IN Q N N <br />I� M <br />_OO a-)� �_ N O e- <br />O Z <br />O O Q O O O I <br />O <br />N <br />� o 0 0 0 00 i <br />L� w <br />ni ri � ui co <br />' cr, >- <br />00 //� ZF- <br />W QZ <br />O W <br />-� o W 130 Lo LE <br />()L)co N NARM �° oW>- <br />Z a�a <br />r- Q W o a <br />LENNAR TAMPA DIVISION �In = m=��W <br />� <br />4600 W CYPRESS ST SUITE 200 z <br />NOTICE TO BUILDER & ALL SUBCONTRACTORS a. mg2 <br />TAMPA, FL 33607 Q ZWW <br />IT IS THE INTENT OF DESIGN PROFESSIONAL LISTED IN THE TITLE Z V az <br />813.574. 5700 BLOCK THAT THESE DOCUMENTS ARE ACCURATE, PROVIDING Z <br />LICENSED PROFESSIONALS CLEAR INFORMATION. EVERY ATTEMPT V <br />HAS BEEN MADE TO PREVENT ERRORS: THE BUILDER AND ALL O <br />SUBCONTRACTORS ARE REQUIRED TO REVIEW ALL THE O <br />INFORMATION CONTAINED IN THESE DOCUMENTS, PRIOR TO THE <br />COMMENCEMENT OF ANY WORK. THE DESIGN PROFESSIONAL ARE MM <br />NOT RESPONSIBLE FOR ANY PLAN ERRORS, OMISSIONS,OR W <br />MISINTERPRETATIONS UNDETECTED AND NOT REPORTED TO THE Q <br />DESIGN PROFESSIONAL PRIOR TO CONSTRUCTION. ALL z w <br />C s CONSTRUCTION MUST BE IN ACCORDANCE TO THE INFORMATION <br />FOUND IN THESE DOCUMENTS. ANY QUESTIONS REGARDING THE <br />INFORMATION FOUND IN THESE PLANS SHOULD BE DIRECTED TO THE N <br />DESIGN PROFESSIONAL LISTED IN THIS TITLE PAGE. NO BACK LAST PLOT DATE <br />CHARGES WILL BE CONSIDERED FOR REIMBURSEMENT BY THE May 8, 2023 <br />2551 DESIGN PROFESSIONAL WITHOUT ADVANCED NOTIFICATION AND Z O <br />APPROVAL BY THE DESIGN PROFESSIONAL. <br />J COVER SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.