Laserfiche WebLink
I <br />- I I <br />I I � <br />I `O 5'-11" <br />--' Cs EDRO M <br />BEDROOM 0 #3 <br />#4 db <br />dbG N <br />BATHROOM <br />1'-7" I #2 (,0i <br />• GFI <br />/F>-(A 17 <br />5'- " <br />/ v J AHU / \ GFI I <br />• CS / � <br />/ R►1 A. " <br />BEDROOM <br />#5 A — GFI LAUNDRdb <br />Y <br />QS LIGHT AND <br />SWITCH IN <br />TTIC <br />-ACID /* VOS --------------- P-9 4 <br />/ Lo <br />F LOFT <br />5'-10" Cs - - <br />1 BEDROOM I - <br />#6 `r <br />C <br />GFI --- -- <br />m <br />GFI ------ <br />OWNERS <br />BATHROOM TO 1ST <br />, <br />GFI FLR ELEC <br />v- <br />B <br />6'-7" <br />W.I.C. <br />I <br />I � <br />OWNERS <br />BEDROOM <br />SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS' <br />1 /411 = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH— <br />4 1/2" <br />0 <br />DOOR JAMB -----)DUPLEX <br />OUTLET ih <br />TRIM <br /><� <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oz <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />E)r 110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />--�}. TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />© STRUCTURED WIRE OUTLET <br />-�— SWITCH AT 36" <br />CID <br />3 WAY SWITCH AT 36" <br />-W— 4 WAY SWITCH AT 36" <br />-� PUSH BUTTON FOR GARAGE DOOR OPENER <br />--fl DIMMER SWITCH AT 36" <br />--� PUSH-BUTTON DOORBELL <br />CLG MNT LT FIXTURE <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />{}- SURFACE MNT FIXTURE <br />-} WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />4 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />�\ 50W MR16 4" LOW VOLTAGE OWNER <br />,08 50W PAR20 NFL 4" MINI ROUND RECESS <br />io' 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-v CLG FAN PREWIRE AND SWITCH <br />Cs COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />cU-18m UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />c S-48 — SINGLE 48" FLUOR STRIP <br />D-48— DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />® 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:R 24" VANITY LIGHTING <br />FFF 36 :F� 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />4C� DOUBLE FLOOD LIGHT W/ COVERS AND <br />L 15OW PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />03 CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />-6&7 ELEC PANEL <br />Q VACUM OUTLET AT 12" <br />14 CEILING RETURN AIR <br />01 A/C REGISTER <br />OT THERMOSTAT <br />In SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />^V) ` O N O <br />L ''C '0 <br />W U <br />V)VI -0 V CO 0t <br />� ,=v <br />CM <br />� <br />0 2 <br />QMQ <br />25 <br />� = °"g R <br />t U d^ <br />< <br />.N V W a� <br />0 0 E00 <br />V <br />wW <br />LU <br />�W a <br />�0 <br />WYO <br />`t H <br />�-JU)0: W';QJO <br />E00coQz <br />O <br />H <br />a0= <br />��a8 w�v� <br />LL Wx<0 <br />-1 <br />cnU' <br />Z <br />a$W°MQV5Z2LU25 <br />< <br />LL a o 0 <br />oQz <br />O <br />Z <br />W <br />OF- <br />M O <br />F- <br />Q U) M Lf <br />U- <br />U) <br />ti <br />z <br />U, .41f Lo <br />F— W CL M <br />Q>-000 <br />Z U F— <br />W <br />J 0 <br />Mj <br />2,12J23 <br />Virtual <br />evi <br />IA <br />I <br />silt, <br />Inc. <br />Plans Review <br />for <br />om <br />lete <br />an <br />ap <br />o <br />compliance w <br />h t <br />0 <br />0 F <br />C <br />Ed <br />tion <br />by Debra <br />nn <br />Kja <br />r b <br />LO <br />0 <br />0 <br />O <br />cl <br />NO <br />M <br />- <br />O <br />M <br />N <br />O <br />M <br />Cq <br />0 <br />IT <br />o <br />o <br />e_- <br />0 <br />o <br />Q <br />o <br />- <br />I <br />0 <br />N <br />'^ <br />W <br />o: <br />w <br />> <br />o <br />•- <br />0 <br />N <br />0 <br />.M <br />0 <br />V <br />0 <br />to <br />0 <br />CO <br />LOV <br />, <br />Mq <br />Zz <br />W <br />¢W <br />O-� <br />W1300 <br />0) <br />0 <br />U <br />00� <br />-� <br />F'- <br />O <br />� z j <br />o�0 <br />-� <br />Z <br />X—a <br />Q Q <br />_ <br />Ln <br />0 <br />F- z <br />('V <br />O <br />zo= <br />■ ■ <br />LLI <br />v7 <br />Lai <br />0 <br />ZWO <br />Q <br />V <br />gWLL <br />LL <br />Z <br />Z <br />�Z <br />0U <br />0CL <br />W <br />z <br />z <br />z <br />w <br />W <br />J <br />0 <br />LAST PLOT DATE <br />. <br />May 8, 2023 <br />O <br />2ND FLOOR <br />_J <br />ELECTRICAL PLAN <br />ABKL&M <br />