My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6444 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6444 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:53:34 PM
Creation date
2/18/2025 3:36:22 PM
Metadata
Fields
Template:
Building Plans
Street #
6444
Location
Bar S Bar Trl
Contractor
Lennar Homes LLC
Building Plans - Permit #
4650
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAx1-V,2"" LONG (14"-1" CROWN) <br />AfALL SHE,ATHING. <br />i 6 +�""' OI1) III"1°4'1°-1 i" <br />STAPLES "fl -� 2 VERTBET+''EEI°1 -Pat{�''IP""II,I <br />N . 1�5Ga�x"II-1'u� <br />111-� <br />-OF=SET I W I I STAPLES <br />6"" <br />TglL1 I,PCTE'D THU, N - <br />STAPLES BET1»AIEiEINI STUDS AS SHiO�"��I I _.... —. ..w.._._-a_ ®..... _..... � .�TUD�'°IS O 0, VER T INTO <br />(VOTED 7111LS®—) <br />IVI <br />ETAL LATH ATTACHMENT DETAIL <br />REV.09.24.21 - SCALE:314" V-0' <br />*DETAIL E; CEED S THE REQUIREMENTS FOR FBCP, 703.7.1 LATH' <br />"ONLY APPLIES TO LENNAR TPAJA ' <br />LATHING ACCESSORIES: <br />ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. <br />WOOD APPLICATION: 16 GA. x 1-1/2" LONG (3/4"-1" CROWN) STAPLES @ 6" O.C. <br />VERTICALLY/HORIZONTALLY INTO FRAMING MEMBERS. <br />MASONRY APPLICATION: CONCRETE STUB NAIL, 3/8" (10 MM) HEAD DIA. MIN. @ <br />6" O.C. VERTICALLY/HORIZONTALLY OR COMPATIBLE ADHESIVES, EXTERIOR <br />GUN -GRADE, CONSTRUCTION ADHESIVE WITH 1" DABS @ 6" O.C. OR IN A <br />SEMI -CONTINUOUS BEAD BETWEEN THE SOLID PLASTER BASE AND THE SOLID <br />PORTION OF THE KEY ATTACHMENT FLANGE. <br />CONTROL JOINTS: INSTALL CONTROL JOINT LATHING ACCESSORIES IN <br />CONFORMANCE WITH C1063. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS, BUT SHALL BE STOPPED AND TIED AT EACH SIDE. <br />ALL ACCESSORIES SHALL BE IN ACCORDANCE WITH THE LATEST ASTM C1063 & <br />ASTM C1861. <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />5'-0" <br />STUB -OUT FOR <br />GAS METER C — <br />O <br />N <br />H C G <br />C C C <br />a _ <br />o <br />1' -0" 0 9 ' <br />o <br />ty U <br />0 <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2) 15d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-V <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2) 16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />W <br />J <br />m <br />rD <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE I INF <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />i. + <br />+ <br />+ + + + + + + + o <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + + E0 <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + ... <br />+ + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ + <br />+ <br />+ -0" (TYP.) <br />4'-0" <br />+ <br />+ + <br />+ + <br />4'-0" <br />+ <br />+ <br />L� <br />+ + <br />+++ <br />+ + <br />+ + 9 <br />+ <br />+ <br />+ <br />+ �F1- <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + o <br />+ + <br />+ + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + + + <br />+ + <br />++ <br />+++ <br />+++++++++ <br />+ <br />140 MPH (1.1103 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + <br />4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />+ + <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH <br />r <br />— 15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />\-RIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH <br />NOTE: I---- <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp <br />5000s 1.8/1.7 <br />wood panels <br />nel <br />Two 3/4" wood panels or 2 x <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONST!Z& <br />(Not required if both load <br />Filler bl <br />1/8" gap <br />FILL CELLS STD. 90° HOOK r- BOND BEAM <br />SIMPS( <br />w/(22)' <br />NAILS 1 <br />CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. } Small gap 2" min. <br />2" <br />max. 4 max. <br />Clinch nails <br />when <br />possible 1 <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />g 2xrequired when indicated or 4" max._: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />--- <br />code for appropriate <br />1/16 <br />details in <br />4 <br />One 10d box <br />areas=20 of high <br />6 <br />or=20 sinker <br />lateral load. <br />t <br />? <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />for each lapped joist. <br />10d nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />61 <br />higher than 15001b <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.— <br />❑ CD t(0 D <br />IV <br />le 6it-5, <br />6" A 1%" ROUND HOLE MAY 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%" <br />Round Hole Diameter (in <br />2 <br />3 <br />4 <br />15 <br />6 <br />7 <br />18 <br />375 <br />10 <br />11 <br />12 <br />13 <br />Rectangular Hole Side (in) <br />- <br />2 <br />3 <br />5 <br />6 <br />8 <br />9 <br />10 <br />Any 16" joist <br />Span (t) <br />8 <br />1'-0" <br />1 1" <br />1 2' <br />" 2" <br />1'-3" <br />1' 3" <br />1'-7" <br />1 '_1 I" <br />2'" <br />2'-9" <br />3'-2" <br />3'e7" <br />12 <br />V-0" <br />V-1" <br />V-2" <br />V-2" <br />V-3" <br />V-9" <br />2'-4" <br />2 1" <br />3`-7" <br />4.-2" <br />4'-9" <br />5'-4" <br />16 <br />V-0" <br />V-1" <br />1'-2° <br />1'-2" <br />V-7" <br />2'-5" <br />3'-2" <br />3'10" <br />4'-9" <br />5,-7„ <br />6 4" <br />7.-2- <br />20 <br />V-0" <br />1' 1" <br />2" <br />1'-2" <br />2'-0" <br />3'-0" <br />4'-0" <br />4'40" <br />5'-11" <br />6'-11" <br />7'-11" <br />8'-11*` <br />24 <br />V-0" <br />1° 1" <br />�.-2" <br />V-3" <br />2'-5" <br />3'-7.' <br />4'-9" <br />5'40" <br />7'-2" <br />8'_4" <br />9'-06 <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4, SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1 Z" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S <br />Backer block (12" wide min.) <br />Nail with 10- 10d nails. <br />\Install tight to_top flange. <br />JC <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />.77 <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />BCI 5000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5- d <br />BCI 6000s0 <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60se <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11- " <br />3-16d <br />3-16dd <br />14" <br />5-16d <br />5-16d" <br />6-16d <br />6-16d <br />5/8" >0 <br />THRU <br />BOLT <br />SIMPSC <br />w/(22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />Ice <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />E AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM-/ ° <br />SEE PLAN FOR °• a . • • ° <br />FOUNDATION INFO ' 4- <br />STEM FOUNDATION <br />GRADE REINF. SEE PLAN <br />d A <br />* X �^ <br />i-Vkl UNA= 4 rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />,UN 1 1 2022 <br />V181"UAL REVIEW ASSIST <br />Virtual Review Assist, Inc. <br />Plans Rle�°�eW completed and proved <br />for corn p"zrl�^ ? with the 2020 FBC 7th <br />Edition by Debra Anne Klahr PX2300 <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />'Io LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18) 10d x 1 1/2" REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION - <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />PLUMBING LINE <br />TOP (2) #5's x 4'-0" <br />PIPE CENTERED <br />@ PVC OR SCH40 SLEEVE <br />PENETRATION <br />° I `_ <br />„III I I I,TI I I 1 1=1 d /4114 <br />111=II)E III— =1TI � ) <br />IIIIII <br />Ir SEE END. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION r PLUMBING LINE <br />- --- - - - - - - - - - - - - - - <br />\: .. . .. . .. <br />A Y <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @PIPE <br />PENETRATION PLUMBING LINE <br />FF <br />7 -�. d -�.-- °- <br />I I a <br />-III—III—I a a I—III—III- <br />11=111— \ ° —1 1=I 1, <br />III- <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />� <br />`}. <br />r't 6 <br />r F =` f -.. <br />N <br />O <br />N <br />0) <br />N <br />J vc, <br />° <br />o <br />00 <br />LO <br />`a Ads 01 05 <br />0 gg <br />aap <br />w <br />' <br />=�a <br />w <br />z <br />Q <br />V) N LO - E <br />-0M o <br />W L <br />co n <br />7 <br />"- M <br />/A��' i i O <br />E ' <br />W O B <br />o <br />O o Q <br />U <br />-t }< <br />.N W Q� N <br />N C <br />o E:m D <br />0 CL <br />W <br />L4J0/ C� W <br />0 LLl Uj W O I- <br />�Q J �Q2z0� <br />O=- <br />I-�- <br />D!Lu <br />JWO���WUOLL_JO <br />�aU'��WgZOwoomzz <br />O <br />� U) W W of Q J <br />0 Z <br />I <0LzuQ�zwZ0W0 (L <br />H Q <br />ILL <br />OLu YzQQ <br />� o o<< O <br />W ¢ O <br />LL <br />O <br />O <br />CN <br />UJ <br />0 F- <br />� U) o <br /><U)CMCO <br />2U)ILL ti <br />QUJ<Lq <br />o�0-cy) <br />r <br />aUa00 <br />z I- <br />LU <br />W <br />J0 <br />O <br />CD <br />It <br />11 <br />C) <br />C)o` <br />CD <br />o <br />0 <br />0 <br />0 <br />N <br />N <br />O <br />0 <br />C)�- <br />0 <br />O <br />I <br />I <br />I <br />' <br />Z <br />O <br />CD LO <br />Lu <br />> <br />N <br />M <br />CO co <br />Z <br />zZ <br />w <br />C)Qw <br />-E--+ <br />W <br />Z <br />000 <br />U <br />UUU) <br />^O <br />�z� <br />LO -0O <br />O1— <br />Q <br />z <br />aka <br />� <br />I- <br />��¢ <br />mr-W <br />N <br />C� <br />1.-1-2 <br />N <br />z-,0 <br />QO? <br />0 N <br />M <br />0 <br />z§0 <br />Q <br />U <br />Quo <br />� ZL- <br />z <br />�Z <br />U� <br />O0 <br />co <br />z <br />SN 1 <br />z <br />z <br />J <br />UJ <br />1`_ <br />O <br />O <br />LAST PLOT DATE <br />z 0 <br />STRUCTURAL <br />DETAILS <br />
The URL can be used to link to this page
Your browser does not support the video tag.