My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6462 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6462 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:07:55 AM
Creation date
2/18/2025 3:36:46 PM
Metadata
Fields
Template:
Building Plans
Street #
6462
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />WALL SHEATHING PER PLAN <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCREED -- <br />WEEP SCREED <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING------ <br />COUNTERFLASHING <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />FLASHING <br />PT 1X10 BLOCKING <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />CEMENT MORTAR <br />TILE ROOF PER SPECS <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 8" <br />ROOF SHEATHING <br />PER PLAN <br />11= 1 1_ni1 <br />311= 1 1-011 <br />WALL SHEATHING PER PLAN <br />STUCCO ON FRAME - 7/8" 3-COAT SAND <br />FINISH STUCCO ON SELF FURRING LATH ON <br />2- LAYERS OF WATER RESISTIVE BARRIER <br />COMPLYING WITH ASTM E2556, TYPE 1 (TYP <br />SHINGLE WATER RESISTIVE <br />BARRIER OVER WEEP SCRE <br />WEEP SCREED <br />HOLD 1/4" AIR GAP <br />BETWEEN WEEP <br />SCREED AND FLASHING— <br />CONT SELF ADHERED FLASHING TO <br />LAP FLASHING AND TURN 3" UP WALL <br />PT 1X BLOCKING <br />COUNTER FLASHING <br />0o <br />PAN FLASHING 6" MIN----___, <br />ROOF UNDERLAYMENT TO <br />TURN UP BLOCKING MIN 6"---_ <br />CONT SELF ADHERED FLASHING <br />TURN 3" UP BLOCKING <br />TILE ROOF PER SPECS---- <br />'' <br />2X NAILER SECURELY <br />FASTENED TO DECK — <br />ROOF SHEATHING <br />PER PLAN ---- <br />NOTE: <br />ALL LATH AND LATH <br />ATTACHMENTS TO BE <br />OUT OF CORROSION <br />-RESISTANT MATERIAL <br />HEAD WALL <br />: ROOF PER SPECS <br />AYMENT <br />3LE OVER <br />3E <br />iEATHING <br />N <br />3E <br />FASCIA <br />HERED WRB TO <br />: OVER WRB ON <br />:LOW <br />kCKER ROD <br />SLANT <br />'J' MOULDING <br />'F BRAKE METAL <br />ON FRAME - 7/8" <br />SAND FINISH STUCCO <br />FURRING LATH ON 2- <br />OF WATER RESISTIVE <br />COMPLYING WITH <br />556, TYPE 1 (TYP) <br />IEATHING PER PLAN <br />FLASHING REQUIREMENTS <br />FIBER CEMENT SIDING R730.1 GENERAL. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A <br />PER ELEVATIONS WEATHER -RESISTANT EXTERIOR WALL ENVELOPE. THE EXTERIOR WALL ENVELOPE 006 N 40 <br />SHALL INCLUDE FLASHING AS DESCRIBED IN SECTION R703.4. -0 > 0 <br />WALL SHEATHING PER PLAN WALL SHEATHING PER PLAN 2 0 <br />R703.1 .1 WATER RESISTANCE. THE EXTERIOR WALL ENVELOPE SHALL BE DIMENSIONED <br />SHINGLE WATER RESISTIVE AND CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION OF WATER Q O 2 <br />BARRIER OVER FLASHING FIBER CEMENT SIDING WITHIN THE WALL ASSEMBLY BY PROVIDING A WATER-RESISTANT BARRIER BEHIND THE cu -0 �— <br />PER ELEVATIONS EXTERIOR CLADDING AS REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO CD <br />THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR CLADDING. -� V .� +- <br />STARTER STRIP Cc �'< <L3 <br />SHINGLE WATER RESISTIVE (D <br />BARRIER OVER FLASHING R703.2 WATER RESISTIVE BARRIER. ONE LAYER OF NO.15 ASPHALT FELT, FREE FROM <br />HOLD 1/4" AIR GAP HOLES, COMPLY WITH ASTM D226 FOR TYPE 1 FELT OR OTHER APPROVED O O_ O <br />BETWEEN SIDING AND STARTER STRIP WATER -RESISTIVE BARRIER SHALL BE APPLIED OVER STUDS OR SHEATHING OF ALL O O O L.L <br />cu <br />FLASHING HOLD 1/4" AIR GAP EXTERIOR WALLS NO. 15 ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE O Oco0 <br />UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 INCHES. WHERE .� O <br />COUNTER FLASHING BETWEEN SIDING AND E <br />FLASHING JOINTS OCCUR, FELT SHALL BE LAPPED NOT LESS THAN 6 INCHES. OTHER APPROVED to O L ++ Q <br />CONT SELF ADHERED FLASHING TO MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE WATER -RESISTIVE 0 Q <br />LAP FLASHING AND TURN 3" UP WALL CONT SELF ADHERED FLASHING TO BARRIER MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE NO.15 ASPHALT FELT F— -0 V) �C <br />LAP FLASHING AND TURN 3" UP WALL OR OTHER APPROVED WATER -RESISTIVE BARRIER MATERIAL SHALL BE CONTINUOUS <br />FLASHING TO THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />10 <br />PT 1X10 BLOCKING— PT 1X BLOCKING APPENDAGES IN A MANNER TO MEET THE REQUIREMENTS OF THE EXTERIOR WALL <br />ENVELOPE AS DESCRIBED IN SECTION R703.1. <br />CONT SELF ADHERED FLASHING OOUNTER FLASHING <br />TURN 3" UP BLOCKING R703.7.3 WATER -RESISTIVE BARRIERS WATER -RESISTIVE BARRIERS SHALL BE <br />IoN_ .9 <br />PAN FLASHING 6" MIN INSTALLED AS REQUIRED IN SECTION R703.2 AND, WHERE APPLIED OVER WOOD -BASED <br />CEMENT MORTAR SHEATHING, SHALL INCLUDE A WATER -RESISTIVE VAPOR -PERMEABLE BARRIER WITH A <br />ROOF UNDERLAYMENT TO PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER. THE <br />TILE ROOF PER SPECS TURN UP BLOCKING MIN 6" INDIVIDUAL LAYERS SHALL BE INSTALLED INDEPENDENTLY SUCH THAT EACH LAYER <br />ROOF UNDERLAYMENT TO CONT SELF ADHERED FLASHING PROVIDES A SEPARATE CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN <br />TURN UP BLOCKING MIN 8° TURN 3" UP BLOCKING ACCORDANCE WITH SECTION R703.4) INTENDED TO DRAIN TO THE WATER -RESISTIVE <br />BARRIER IS DIRECTED BETWEEN THE LAYERS. <br />ROOF SHEATHING TILE ROOF PER SPECS \ <br />PER PLAN EXCEPTION: WHERE THE WATER -RESISTIVE BARRIER THAT IS APPLIED OVER <br />2X NAILER SECURELY WOOD -BASED SHEATHING HAS A WATER RESISTANCE EQUAL TO OR GREATER <br />FASTENED TO DECK THAN THAT OF 60-MINUTE GRADE D PAPER AND IS SEPARATED FROM THE STUCCO <br />BY AN INTERVENING SUBSTANTIALLY NON -WATER -ABSORBING LAYER OR <br />ROOF SHEATHING DESIGNED DRAINAGE SPACE. <br />PER PLAN <br />R703.4 FLASHING. APPROVED METAL FLASHING, VINYL FLASHING, SELF -ADHERED <br />MEMBRANES AND MECHANICALLY ATTACHED FLEXIBLE FLASHING SHALL BE APPLIED <br />SHINGLE -FASHION OR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />METAL FLASHING SHALL BE CORROSION RESISTANT. FLUID -APPLIED MEMBRANES USED <br />AS FLASHING SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S <br />RAKE WALL HEAD WALL RAKE WALL INSTRUCTIONS. ALL FLASHING SHALL BE APPLIED IN A MANNER TO PREVENT THE <br />ROOF TO WALL -BARREL TILE TO SIDING ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE <br />BUILDING STRUCTURAL FRAMING COMPONENTS. <br />W P 311- I 1_019 SELF -ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH MMA 711. ALL <br />EXTERIOR FENESTRATION PRODUCTS SHALL BE SEALED AT THE JUNCTURE WITH THE <br />BUILDING WALL WITH A SEALANT COMPLYING WITH AAMA 800 OR ASTM C920 CLASS 25 <br />GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, <br />ASTMC1281, MMA 812, OR OTHER APPROVED STANDARD AS APPROPRIATE FOR THE <br />TYPE OF SEALANT. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR <br />WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE <br />OF THE EXTERIOR WALL FINISH. APPROVED FLASHINGS SHALL BE INSTALLED AT THE <br />FOLLOWING LOCATIONS: <br />1. 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW <br />AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL <br />FINISH OR TO THE WATER -RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 <br />FOR SUBSEQUENT DRAINAGE. MECHANICALLY ATTACHED FLEXIBLE FLASHINGS <br />SHALL COMPLY WITH MMA 712. FLASHING AT EXTERIOR WINDOW AND DOOR <br />OPENINGS SHALL BE INSTALLED IN ACCORDANCE WITH ONE OR MORE OF THE <br />FOLLOWING: <br />1.1 THE FENESTRATION MANUFACTURER'S INSTALLATION AND FLASHING <br />INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESSED IN THE <br />FENESTRATION MANUFACTURER'S INSTRUCTIONS, IN ACCORDANCE WITH <br />THE FLASHING MANUFACTURER'S INSTRUCTIONS. WHERE FLASHING <br />INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PLAN FLASHING SHALL BE <br />INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN <br />FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT <br />WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER <br />RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE. OPENINGS USING PAN l <br />FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD 5 <br />AND SIDES. <br />1.2 IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A <br />REGISTERED DESIGN PROFESSIONAL. <br />1.3 IN ACCORDANCE WITH THE OTHER APPROVED METHODS. <br />1.4 IN ACCORDANCE WITH FMA/AAMA 100, FMA/AAMA 200, FMA/WDMA <br />250, FMA/AAMA/WDMA 300 OR FMA/AAMA/WDMA 400. <br />2.2 AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. <br />3.3 UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL <br />COPINGS AND SILLS. <br />4.4 CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />5.5 WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A <br />WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. <br />6.6 AT WALL AND ROOF INTERSECTIONS. <br />7.7 AT BUILT-IN GUTTERS. <br />ARE GENERIC AND MEANT TO SHOW <br />LS <br />WP 18 THESE <br />FLASHI GI AND WATERPROOFING METHODS O BEUSED. GENERAL <br />pL 21 2023 <br />Virtual ReviewtAssist, <br />ed approved <br />Plans Review camp <br />e <br />with the K ahU FBCPX23Ith 00 �ddion <br />,or comphyfiance <br />OeW Anne <br />CD <br />C� <br />ca <br />O <br />L <br />CL <br />IL <br />Q <br />U <br />O <br />L <br />n <br />Mcu <br />W <br />SHEET N0. <br />WP 211 <br />
The URL can be used to link to this page
Your browser does not support the video tag.