Laserfiche WebLink
A <br />D <br />FIRST FLOOR ELECTRICAL PLAN A <br />1 /411 = 1'-01 <br />1 <br />SECOND FLOOR ELECTRICAL PLAN A <br />1 /4" = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 <br />& 250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH_ <br />�4 <br />SWITCH <br />° <br />4 1/2" <br />DOOR JAMB <br />DUPLEX <br />OUTLET- <br />TRIM <br />�� <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL— <br />o <br />2� <br />---SMOKE DETECTOR <br />V-0" <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" <br />NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" <br />ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" <br />SHALL BE <br />SPLIT 110V DUPLEX OUTLET <br />MOUNTED <br />HORIZONTAL <br />AT 12" - TOP PLUG IS HOT <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />® FOR LOCATION & TYPE <br />® TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />SW STRUCTURED WIRE OUTLET <br />0 SWITCH AT 36" <br />6 3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />-� PUSH-BUTTON DOORBELL <br />-A - CLG MNT LT FIXTURE <br />JUL <br />-EB <br />CLG MNT PREWIRE - FIXTURE BY OWNER <br />}C <br />SURFACE MNT FIXTURE <br />{T} <br />WALL MNT FIXTURE <br />NOTE: <br />C\ <br />ND OPALEX - <br />ALTERNATEN <br />TUB/SHOWER <br />CANS MAY BE <br />®� <br />50W PAR30 NFL 6" WHITE BAFFLE <br />USED IF <br />APPROVED B <br />(J� <br />50W MR16 4" LOW VOLTAGE <br />OWNER plans R v <br />for camp lea n <br />lC <br />50W PAR20 NFL 4" MINI ROUND RECESS by 0 <br />`�o� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />C SMOKE DETECTOR <br />=U-18= UNDER CABINET 18" <br />=S-18- SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />-S-24- SINGLE 24" FLUOR STRIP <br />-D-24- DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />D-48 — DOUBLE 48" FLUOR STRIP <br />24 <br />24"CLG MNT WRAPPED FLUOR LIGHT <br />48 <br />48"CLG MNT WRAPPED FLUOR LIGHT <br />Fr�24:i;� <br />24" VANITY LIGHTING <br />gi—= 36 � <br />36" VANITY LIGHTING <br />48 <br />48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />EXHAUSTFAN <br />�p DOUBLE FLOOD LIGHT W/ COVERS AND <br />d 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />® CEILING MNT SPEAKER <br />® CHIMES (DELETE W/ INTERCOM) <br />�f MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />WA CEILING RETURN AIR <br />EHI A/C REGISTER <br />C THERMOSTAT <br />® SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />I <br />14 4) > IO � a <br />W L C -O U <br />i`' AMC <br />v� M M <br />V) U .0 -0— co <br />di �o zu8 <br />� <br />O Q <br />t tea^ <br />.N V w S2� <br />W L 0O E00 <br />5 <br />IC-1 <br />w (D W <br />w <br />W W J �wyj o <br />E m m J O Q C YU o J O <br />Q Q U <br />�C7xJzx Oz�o�F-�F <br />OwHoZtMOOmZ= <br />-< <br />p O <br />W 0 Z <br />cnwa�v�ww�ixx<0a-j <br />JOa z ea z owe, <br />-J w<Ow 05 wz-�U <br />a <br />< <br />OW O od Q <br />��u <br />O <br />O <br />N <br />Ow <br />0-4 <br />Ln = O <br />��-+��DO <br />O <br />Ln <br />Q J Ln <br />((; <br />LL <br />warn <br />Z <br />QO <br />F- <br />Z <br />2023 <br />w <br />� o <br />'d- <br />N <br />M <br />cM <br />Review Assist, I a <br />p ra <br />t <br />M <br />N <br />v <br />completed and <br />ith the 2020 FBC <br />7th <br />N <br />N <br />a Anne Mahr PX2 <br />00 <br />4 <br />O <br />O <br />O <br />O <br />O <br />O <br />O <br />O <br />O <br />r <br />co <br />00 <br />ao <br />o <br />N <br />CD <br />N <br />N <br />N <br />N <br />0 <br />N <br />I <br />0 <br />N <br />I <br />0 <br />CV <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />0 <br />N <br />d) <br />N <br />O <br />O <br />O <br />— <br />O <br />e- <br />o0 <br />O <br />N <br />ch <br />O <br />NO <br />N <br />� <br />�- <br />0 <br />N <br />0 <br />M <br />0 <br />� <br />0 <br />to <br />0 <br />CO <br />0 <br />r- <br />LO 4 <br />Cr <br />Z Z <br />O <br />w <br />owU) <br />O <br />L)W <br />LUa <br />M -0 <br />O0. <br />LO -0 <br />Z. <br />ZW~� <br />=mZ <br />�- <br />ZX:W <br />a <br />�2zw <br />TI <br />a. <br />Z Z <br />%� <br />w I\ <br />a <br />O <br />V�'Zz <br />-3 z <br />CV <br />Z <br />Z <br />~a0 <br />U <br />Ua <br />00 <br />W <br />zA6 <br />Q <br />z <br />Z <br />J <br />W <br />M <br />O <br />(0 <br />T— <br />LAST PLOT DATE <br />> <br />May. 8, 23 <br />1 ST & 2ND FLOOR <br />. ■ <br />z4-0 <br />0 <br />,J <br />ELECTRICAL PLAN A <br />