My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6470 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6470 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:53:55 AM
Creation date
2/18/2025 3:37:26 PM
Metadata
Fields
Template:
Building Plans
Street #
6470
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1-A- I f "I _ I 1 II 1111 11 111111 I I I I <br />ELEC <br />METER <br />I <br />L <br />------------I <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION B <br />1 /411 = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210,52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER 2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />�- -- 4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />Ik <br />SWITCH ° <br />4 1/2" <br />DOORJAMB DUPLEX <br />OUTLET r� <br />TRIM o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL---,, j <br />oz <br />'k—_'SMOKE <br />DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" CABOVE <br />OUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />�} TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />QSTRUCTURED WIRE OUTLET <br />SWITCH AT 36" <br />Cn <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />—o DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />-} CLG MNT LT FIXTURE <br />{ CLG MNT PREWIRE - FIXTURE BY OWNER <br />SURFACE MNT FIXTURE <br />{- WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />'0 TUB/SHOWER CANS MAY BE <br />,C 50W PAR30 NFL 6" WHITE BAFFLE USEDIF <br />APPROVED BY <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />,t(D 50W PAR20 NFL 4" MINI ROUND RECESS <br />50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />-+} CLG FAN PREWIRE AND SWITCH <br />COMBINATION CARBON MONOIXED DETECTOR/ <br />cs SMOKE DETECTOR <br />O SMOKE DETECTOR <br />°U-182 UNDER CABINET 18" <br />=S-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />= U-36 = UNDER CABINET 36" <br />S-36 = SINGLE 36" FLUOR STRIP <br />D-36 = DOUBLE 36" FLUOR STRIP <br />S-48 — SINGLE 48" FLUOR STRIP <br />—D-48— DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />F;�24:;;1 24" VANITY LIGHTING <br />F;;—= 36 — 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />�j DOUBLE FLOOD LIGHT W/ COVERS AND <br />V 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />INEZ] ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />® A/C REGISTER <br />OT THERMOSTAT <br />III SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />t^o` <br />N LO <br />2 <br />W L U <br />CV) <br />M <br />4- <br />(n <br />M <br />DU m M r- <br />V Q <br />L co <br />2 <br />°Q <br />` LU <br />Oo E <br />7W <br />V <br />o a <br />LIJ <br />❑uj w0uj <br />Li f-Q X 2 __1 WW W <br />UQ <br />V <br />¢ui <br />OZOH❑ <br />o:_jO�Cr�u,U <br />f)-�OI <br />OzE O <br />¢JO <br />QO <br />OOQ Onm OZOWMzzF�" <br />LU <br />U YI'_ W <br />Z <br />aO <br />(n Z <br />�gw <br />O¢<o--UILL <br />u.¢ O i-¢u <br />O <br />O <br />Z 04 <br />OF_ <br />T 5 ti <br />F— M O <br />Q VA (M r- <br />(1) LL <br />ti <br />I —Wa.cM <br />a 00 <br />Z U F- <br />W <br />W <br />J O <br />O <br />A <br />V <br />Virtual Revi <br />�) <br />Assist, <br />A <br />I <br />I <br />Inc. <br />I <br />ans Review coml <br />tmpliance <br />etecl <br />with th <br />20 <br />an <br />D- <br />app <br />Cld <br />by Debra Anne <br />Kla <br />Sdi <br />Toro <br />r X <br />LO <br />N <br />0 <br />0 <br />o <br />N <br />0 <br />N <br />0 <br />N <br />N <br />N <br />N <br />t— <br />O <br />N <br />.— <br />N <br />O <br />O <br />N <br />O <br />sr <br />r <br />N <br />Co <br />o <br />O <br />.� <br />0 <br />o <br />N <br />N <br />N <br />o <br />I <br />I <br />' <br />Z <br />O <br />N <br />x <br />W <br />o <br />0 <br />0 <br />0 <br />0 <br />0 <br />LO <br />> <br />c- <br />N <br />M <br />4 <br />to <br />CD <br />W <br />Z} <br />~Z <br />W <br />wO <br />4_j <br />z <br />OWO <br />UOo7 <br />Lr) <br />O <br />::)zj <br />Or❑ <br />Q <br />Z <br />aixa <br />F— <br />II <br />2 <br />m = w <br />F- <br />N <br />Ir <br />EOM <br />. (.0 <br />Q <br />O <br />zwo <br />�. <br />N <br />U�Z <br />Z <br />z <br />� <br />OU <br />MMO <br />W <br />� <br />z <br />Z <br />z <br />w <br />0 <br />~ <br />LLJ V''^^J <br />0 <br />LAST PLOT DATE <br />• <br />May 8, 2023 <br />ZO <br />� <br />1ST FLOOR <br />ELECTRICAL PLAN B <br />
The URL can be used to link to this page
Your browser does not support the video tag.