My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6478 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6478 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 9:08:40 AM
Creation date
2/18/2025 3:38:01 PM
Metadata
Fields
Template:
Building Plans
Street #
6478
Location
Bar S Bar Trl
Contractor
Lennar Homes
Building Plans - Permit #
4271
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEE 3/S5 FOR <br />STANDARD <br />GABLE END <br />FRAMING <br />2X TOP PLATE TO — <br />GABLE END W/ 16d <br />NAILS @ 6" O.C. <br />2X4 STUDS @ 24" O.C.— <br />W/ SINGLE BASE & TOP <br />PLATE W/ PLYWOOD <br />SHEATHING COVERING <br />0 <br />z <br />Q <br />W <br />U) <br />0 <br />0 <br />0 <br />CL <br />J <br />_I <br />U- <br />STRUCTURAL <br />SHEATHING 7/16" MIN. <br />NAILED W/ 8d COMMONS <br />@ 3" O.C. @ EDGE & 6" <br />O.C. FIELD RUN FULL <br />SHEET FROM BOTTOM <br />OF FALSE BEAM <br />GE151 FALSE BEAM @GABLE END <br />(2) SCALE: 3/4" = V-0" <br />o <br />M LO '3 r <br />ENGINEERED ROOF PER ASCE 7-16 ROOF DESIGN ALLOWABLE COMPONENTS AND <br />RS H CLADDING WIND PRESSURES AND SUCTIONS FOR MEAN ROOF HEIGHT <_ 25 ft <br />WIND SPEED (ULTIMATE) 140.0 MPH <br />WIND SPEED (ALLOWABLE) 108.4 MPH <br />EXPOSURE CATEGORY C <br />EFFECTIVE WIND PRESSURE AND SUCTION (PSF) <br />WIND AREA (+) VALUE DENOTES PRESSURE HIP ROOF >20 TO 45 DEG. <br />(SQ FEET) I W VALUE DENOTES SUCTION [4:12]-[12:12] <br />a=oft <br />AREA ROOF 1 2e 2n 2r 3 3e 3r <br />io HIP -35.94 -49.57 -49.57 -49.57 <br />GABLE -38.22 -38.22 -60.99 -60.99 -60.99 78.58 <br />ROOF NAILING SCHEDULE/ NAILING ZONES (SHINGLE AND TILE): <br />ZONE 1: ASTM F1667 RSRS-01 (8d) NAILS @ 6" O.C. ON EDGE AND 6" O.0 IN FIELD <br />ZONE 2e, 2n, 2r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ZONE 3, 3e, 3r: ASTM F1667 RSRS-01 (8d) NAILS @ 4" O.C. ON EDGE AND 4" O.0 IN FIELD <br />ROOF SHEATHING: <br />SHINGLE: /fs" EXP. 1 (24/6) or 1%2" EXP. 1 (3 6) <br />TILE: 1%2" EXP. 1 (3Y,6) <br />NOTE: <br />1. PER CODE ASTM F1667 RSRS-01 REFERENCE TO 8d (2 %$" x 0.113") NAILS <br />2. WHERE THE SHEATHING THICKNESS IS GREATER THAN 15/32", SHEATHING SHALL BE FASTENED <br />WITH ASTM F1667 RSRS-03 10d (2'/2" x 0.131") NAILS OR ASTM F1667 RSRS-04 (3" x .120") NAILS <br />3. GABLES- DROP GABLE END & (1) ADDITIONAL DROPPED TRUSS 2x4 #2 SYP OUTLOOKER <br />RAFTER W/ BLOCKING @ 16" O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING <br />@ 16" O.0 FIRST 4 BAYS WITH (2) 12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS <br />W/ BLOCKING PER NAILING SCHEDULE. <br />V V V <br />CJ <br />-- <br />..., Lp <br />Q <br />--- <br />n <br />Q <br />it <br />; <br />CJ3 <br />CJ5 <br />N <br />Q <br />O <br />Q <br />O <br />Q <br />F- <br />CD <br />¢ <br />F- <br />Q <br />. F-. <br />Q <br />Q <br />r <br />Q <br />Q <br />M <br />Q <br />F- <br />Q <br />F-M <br />Q <br />Q <br />(7 <br />LO <br />co N 000 <br />m m m m M (� <br />MLJ <br />SIM <br />GE1 <br />_ <br />FE <br />FG1I k0 18 <br />D1 <br />EJ7 <br />I (2) 2x12 #2 SYP WD. BM. w/ <br />FLITCH PLATE. BOTT. OF B' <br />SIMPSON HU410 w/ (18) TITEN <br />EJ7 1/4" x 2 3/4" & (10) 1 Od NAILS <br />EJ7 <br />EJ7 <br />EJ7 <br />EJ7 <br />I <br />CJ5 <br />CJ3 <br />II <br />EJ7 <br />nI <br />EJ7 <br />EJ7 <br />EJ7 <br />X <br />(2)_ <br />EJ7V <br />II <br />I <br />EJ7VA <br />I <br />I <br />cb EJ7VA 0 <br />I � <br />Q <br />X (2) <br />EJ7VA <br />CJ5V <br />CJ3V <br />CJ1V <br />EJ7V <br />EJ7V <br />EJ7V <br />Is <br />EJ7V <br />I <br />°I <br />EJ7V <br />II <br />n <br />( EJ7V <br />I <br />A7 <br />M LO <br />U U U (2) <br />IL <br />o <br />TYP <br />A <br />1 <br />S5 <br />a=4ft <br />GABLE ROOF > 20 TO 45 DEG. <br />[4:12]-[12:12] <br />TYP. BM <br />TO CO. <br />CORNER <br />7/16" OSB <br />0. @ 6-8" <br />UPLIFT CONNECTION CROSS-REFERENCE <br />MARK SIMPSON STRONG TIE USP MANUFACTURING, INC. <br />Q <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />CONNECTOR <br />CAPACITY <br />FASTENERS <br />SYP <br />SPF <br />SYP <br />SPF <br />A <br />META12 <br />1420 <br />9 - 10d x 1 1/2" <br />HTA20 <br />1870 <br />1585 <br />10 - 10d x 1 112" <br />A (2) <br />(2)META12 <br />1875 (1)PLY <br />1795(2)PLY <br />9 - 10d x 1 1/2" <br />B <br />HETA16 <br />1810 <br />9 - 10d x 1 1/2" <br />HTA16 <br />1870 <br />1585 <br />10 - 10d x 1 1/2" <br />C <br />H2.5A <br />565 <br />535 <br />10 - 8d <br />RT7A <br />585 <br />515 <br />10 - 8d x 1 1/2" <br />D <br />H3 <br />400 <br />320 <br />8 - 8d <br />RT3 <br />345 <br />305 <br />8 - 8d x 1 1/2" <br />E <br />META20 <br />1450 <br />7 - 10d x 1 1/2" <br />HTA20-18 <br />1625 <br />1400 <br />10 - 10d x 1 1/2" <br />F <br />HHETA20 <br />2120 <br />10 - 10d x 1 1/2" <br />HTTA20 <br />2375 <br />11 - 10d x 1 1/2" <br />G <br />H10A <br />1040 <br />1015 <br />18 - 10d x 1 1/2" <br />RT16A <br />1020 <br />1160 <br />9 - 10d x 1 1/2% 8-10d <br />H <br />FGTR <br />4725 <br />3400 <br />w/ (18) 1/4" x 3" SIDS <br />WOOD SCREWS AND (2) <br />1/2" x 5" TITEN HD ACHOR <br />BOLTS <br />RFUS <br />7100 <br />--- <br />w/ (12) WS3 WOOD <br />SCREWS AND (4) 3/4" x 6" <br />WEDGE -BOLTS <br />J <br />HTT5 <br />4350 <br />3740 <br />5/8" ANCH. / (26) 10dx1-1/2" <br />HTT5 <br />5795 <br />5/8" ANCH. /(26)10d x1-1/2 <br />K <br />HD313 * <br />3130 <br />3050 <br />5/8" DIA. BOLTS <br />TDX2-TZ <br />3295 <br />--- <br />2 - 5/8" DIA. BOLTS <br />L <br />VGT R/L <br />2225 <br />1600 <br />w/ (16) 1/4" x 3" SIDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />X 2 1/2" SIDS WOOD <br />SCREWS & (1) 5/8" ATR <br />M <br />VGT - F <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SIDS <br />WOOD SCREWS AND <br />HDU4-SDS2.5 w/ (10) 1/4" <br />x 2 1/2" SDS WOOD <br />SCREWS & (1) 5/8" ATR <br />N <br />LUS26 <br />1165/1060 ** <br />1005/915 ** <br />8 - 10d x 3" <br />JUS26 <br />1000/1080** <br />--- <br />8 - 10d <br />P <br />HUS26 <br />1320/3235 ** <br />1335/2820 ** <br />20 - 16d x 3 112" <br />HUS26 <br />2035/3400 <br />--- <br />(20)16d x 3-1/2" <br />Q <br />HUS28 <br />1760/4095 ** <br />1720/3125 ** <br />30 - 16d x 3 1/2" <br />HUS28 <br />2950/5090 <br />--- <br />30d -16d x 3-1/2" <br />R <br />MTS12 <br />990 <br />860 <br />14 - 10d x 1 1/2" <br />MTW12 <br />1195 <br />1005 <br />14-10d x 1-1/2" <br />S <br />VGT - M <br />4940 <br />3555 <br />w/ (16) 1/4" x 3" SIDS <br />WOOD SCREWS AND (1) <br />5/8" ATR EPDXIED w/ <br />SIMPSON SET w/ 12" MIN. <br />EMBEDMENT. <br />T <br />(2) LGT3 <br />6570-M 6960-F <br />4730-M 5010-F <br />w/ (24) 1/4" x 3" SIDS <br />SCREWS & (8) 3/8" x 5" <br />TITEN HD (2 PLY) OR (52) <br />16D SINKERS FOR FRAME <br />U <br />MGT <br />3965 <br />3330 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ SIMPSON "SET" <br />EPDXY <br />MUGT15 <br />4175 <br />22 -10d x (1) 5/8" ATR w/ 12" <br />EMBED w/ USP CIA-7000C <br />EPDXY <br />V <br />(2) LGT2 <br />4060-M 3770-F <br />3500-M 3240-F <br />`N/ (2) D INKERS <br />(14) 1/4" x 2 1/4" TITENS <br />(2 PLY) OR (28) 16D <br />SINKERS FOR FRAME <br />LUGT2 <br />3100-M 4520-F <br />3100-M 3800-F <br />w/ (32) 16D SINKERS & <br />(10) 1/4" x 3" WEDGE- <br />BOLTS (2-PLY) OR (32) 16 <br />SINKERS FOR FRAME <br />"X" HTS 20 1310 1245 24-10d x 1 112" HTW20 1530 1285 24-10d x 1 1/2" <br />SP1 555 535 10-10d SPT22 735 8-10d <br />SP2 11010 605 12-10d SPT24 1090 12-10d <br />HCP2 1 590 555 12-10d x 1 1/2" HHCP2 680 1 570 1 (20)1 Old x 1-1/2" <br />* MINIMUM 3" MEMBER <br />REACTIONS ARE FOR ROOF LOADS ONLY <br />*** DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH COULD FORCE THE PLATE OFF OF THE TRUSS. <br />ALL EPDXY ANCHORS SHALL USE SIMPSON "SET" OR USP CIA-7000C (SEE MANUFACTURES SPECS) <br />NOTE: DOUBLE FELT REQ'D ON ROOF PITCHES 3/12 & LOWER. REVISED 12-02-20 <br />LOADS -- ROOF = L / 360 FLOOR = L / 480 W/ 3/8" MAX DEFLECTION. <br />FLOOR JOIST SPACING SHALL BE MAX OF 19.2" OC FOR HARDWOOD & TILE AREA'S & 24" <br />OC FOR CARPET AREA'S <br />DROP HIP DETAIL <br />2-0-0 MAXIUM SPACING ON VERTICALS OF (8) TRUSS <br />1-8-8 CLEAR GAP BETWEEN (B) TRUSSES (+/- 6") <br />*FASTEN EACH (B) TRUSS WEB TO EACH (A) TRUSS TOP CHORD @ EVERY INTERSECTING <br />POINT SHOWN ON THE HIP TRUSS SYSTEM BELOW. FASTEN TOP CHORDS OF EACH (B) <br />TRUSS TO THE TOP CHORDS OF (A) TRUSSES AT EVERY OTHER INTERSECTING POINT (-). <br />INTERSECTING POINT TO BE FASTENED WITH 2 -16d COMMON NAILS OR 0.128" x 3" GUN <br />NAILS. FASTEN BOTTOM CHORD OF (B) TRUSS TO TOP CHORD OF CARRIER TRUSS WITH <br />THE SAME SPECIFIED COMMON NAILS OR GUN NAILS AT 48" OC. (+) <br />IN LIEU OF PREFABRICATED HIP PLANING TRUSSES, (B) 2x4 SO, PINE #2 OR #2 PT. STICK <br />LUMBER (LAID FLAT WISE) MAY BE USED. FOLLOW FASTENING SCHEDULE AS DEFINED <br />FOR HIP PLANING TRUSSES. R1 <br />STICK FRAMING SPLICING IS ALLOWED BETWEEN TRUSSES OR AT TRUSS wO <br />INTERSECTIONS. SPLICING <br />TO BE STAGGERED BETWEEN COMMON TRUSSES, NO CATS REQUIRED UNDER STICK <br />FRAMING SPLICING. <br />MINIMUM LENGTH OF STICK FRAMING TO BE F-0" ON A HORIZONTAL PROJECTION. <br />NOTE: SEE SHEET D1 FOR ROOF FRAMING DETAILS <br />Ifl(2) -12d TOENAILS EACH SIDE OF FLOOR TRUSS TO WALL OR BEAM <br />BELOW. TYP. AT INTERIOR BEARING U.N.O. <br />(A) <br />OR 2 PLY <br />;ARRIER <br />R <br />2 PLY CARRIER (A) <br />x CONT LEDGER <br />SEE SHEET D1 FOR <br />ROOF FRAMING <br />DETAILS <br />FRAMING PLAN - ELEV-Bl <br />SCALE: %4°=V-0" <br />(U <br />-~ L <br />L, <br />C, v <br />t�. <br />C f, '-` <br />_� n1 <br />tf <br />fV <br />O <br />N <br />N <br />0 <br />M <br />0 <br />" <br />a -�x <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />F' <br />4 <br />E ti <br />oQ �m1- <br />N V N <br />po W J <br />lL <br />0 <br />) � � Z J <br />00 in ik LL <br />ffi <br />d <br />cn r, PL ', Lu _ <br />J LaLL a- � 3: <br />z <br />C13W <br />O <br />_coy 0o <br />0::E <br />1 �,;z of 0 -1 <br />'. C3 <br />I W <br />W <br />M, < <br />� ¢ < <br />Z <br />IL <br />LLa <br />F <br />Mz° avno <br />N <br />U V <br />Z <br />0 C <br />W <br />❑O❑ <br />z N M <br />o g <br />z o Q <br />Q <br />J <br />U) <br />N <br />^ <br />M <br />z <br />o <br />W <br />4-1 <br />� <br />� <br />O— <br />N <br />w o <br />c r <br />LU <br />S � N <br />C) o y <br />c U) <br />'0 <br />r• <br />CD <br />coz <br />M <br />M <br />m <br />a <br />E <br />W O <br />z <br />d N <br />z® <br />cu <br />N <br />XOU <br />&a <br />d o <br />0OU <br />0 d <br />W w <br />L <br />wo <br />¢ <br />C/) <br />o <br />m O <br />z <br />C: <br />J <br />U <br />� <br />Q W <br />�z <br />z0 <br />U <br />Q <br />C <br />LLa <br />�w <br />W <br />do <br />oLL <br />r- <br />�3 <br />C:)w� <br />0 <br />>° <br />a <br />za <br />o� <br />c O <br />0 <br />` <br />J <br />LO <br />m <br />fA <br />r� <br />Q <br />0 <br />C) <br />Co04 <br />N <br />C) <br />ZeCr <br />r <br />U <br />_o <br />U) Y <br />m <br />m <br />¢I <br />4--+ <br />N <br />No <br />LO <br />N <br />LO <br />L <br />r <br />< <br />M <br />T— <br />E <br />'E <br />o <br />z <br />m <br />Z <br />E <br />E <br />d <br />U -j <br />Q p <br />-j <br />JOB <br />NO : <br />22-02390 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />7 <br />-- <br />
The URL can be used to link to this page
Your browser does not support the video tag.