Laserfiche WebLink
3 <br />LO <br />m <br />LO <br />r <br />to <br />a� <br />v` <br />rn <br />0 <br />0 <br />N <br />0 <br />J <br />0 <br />Cn <br />N <br />0 <br />I <br />J <br />m <br />t[ r <br />Q <br />0 <br />0 <br />J <br />C] <br />Cn <br />LO <br />I <br />LO <br />v <br />f� <br />0 <br />0� <br />c <br />Q <br />N <br />a <br />E <br />W <br />E <br />0 <br />v <br />c <br />J <br />LZ <br />O <br />v <br />v <br />ti <br />V <br />0 <br />V <br />a <br />y <br />I <br />v <br />Y <br />O <br />0 <br />V <br />J <br />ID <br />t__ <br />CV <br />M <br />N <br />U <br />0 <br />Na <br />N <br />N <br />M <br />N <br />0 <br />Cn <br />Q <br />m <br />c <br />ELECTRICAL SPECIFICATION 150A/2 INDOOR <br />PANEL <br />C CENTER <br />NOTES: <br />00 #14 copper to lights &outlets S/I , � � Zlt 1, 11 i <br />NEMA t 10 #12 copper to 20 amp ckts y�� `V V <br />50 AMP/ <br />ELECTRICAL CONTRACTOR 200AMP 10 #10-�GI fo Y �� <br />MUST VERIFY WITH THE #10- copper 3�l UT <br />3 copper to Dryer <br />SPECIFICATIONS FOR THE TYPE <br />�T <br />OF FIXTURE TO BE USED. LIGHT I �\ <br />FIXTURES SHOWN ARE FOR METER I I JI1� <br />MO 2t, I I I <br />LOCATION PURPOSES. zoo am 2/0 or 4!0 SER Alu ��, <br />p <br />150amp �I� 2 UNDERGROUND inct 3q <br />3 032" <br />POWER CO. FEED <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING 4 <br />GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVED <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram REV.04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER CO. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4. <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUSTFAN <br />;O <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />1-0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />N TELEVISION (OPTIONAL) <br />©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />u]M ELECTRIC METER <br />owl ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER LOCATION GFI <br />WITH BUILDER <br />ff <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=V-0" <br />N <br />O <br />t .. LL <br />CD <br />— — <br />•A- <br />J <br />f,3 - <br />t� <br />f'. - L.LI . <br />CV <br />C14 <br />0 <br />CV <br />M <br />CV <br />CV <br />`%e <br />e �.b <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within <br />these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />H <br />o c <br />O C, N 3! <br />ACV C,tT # LJL <br />'S <br />V <br />0 <br />LQ <br />a)oo Lo C J , <br />oo a)Xk LL W <br />0)cnr—r <br />a <br />o J w a - <br />C�i c a to <br />vS to <br />Z@ <br />131 <br />0 <br />=I <br />o <br />1% <br />:5 :E '�' �; = 0 _j <br />(0 <br />W <br />�C1No <br />=) <br />. . CoQ <br />Z <br />IL <br />a <br />N MZ ern O <br />6 U U tUn <br />W <br />❑❑❑ <br />N h <br />0 0 <br />Z <br />(D <br />Z O Q <br />� QQN <br />Q <br />J <br />V) <br />N <br />Z v <br />c <br />Ut 0 <br />00 <br />fLI w <br />p m <br />U <br />O <br />N <br />w o <br />� N <br />U <br />w m <br />c�a <br />' — J £ <br />N O <br />I <br />L U <br />U o N <br />C �Q <br />t <br />o <br />S <br />o <br />co <br />w <br />M <br />w z <br />o S <br />z <br />¢ <br />� <br />U_ <br />Q E <br />E 0 <br />o <br />o <br />o� <br />> <br />a� <br />Zm <br />u <br />cu <br />¢� <br />XU <br />�L <br />uo <br />pV <br />a <br />o < <br />N ro <br />¢o <br />ww <br />r <br />a> 1— <br />to <br />U:)o <br />4� <br />Z <br />r <br />mi <br />F O <br />o <br />- c <br />w O <br />> z <br />cn <br />o� <br />zz <br />go <br />Q <br />�� <br />a <br />vw <br />U <br /><o <br />o1z <br />k <br />>o <br />o <br />w <br />a <br />VO <br />z¢T8)3 <br />2 C:)i <br />0 <br />> d- <br />J <br />n ' <br />L / <br />CA <br />cc <br />C) <br />=04 <br />N <br />O <br />QI <br />� <br />N <br />� <br />O <br />CD <br />Lf <br />.0 <br />N <br />M <br />LO <br />LO <br />Q <br />r <br />N <br />T <br />E <br />O <br />Z <br />N <br />Z <br />= <br />E r <br />N <br />00 <br />FL <br />U J <br />Q Q <br />J <br />JOB <br />NO: <br />22-02390 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />- <br />I I d I I - i ,a ft,1;�auiimu,u i,i :u_�L'T_117_1�1Eam, . <br />