My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6479 Beverly Hills Dr
Zephyrhills
>
Building Department
>
Building Plans
>
6479 Beverly Hills Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 9:24:32 AM
Creation date
2/18/2025 3:38:21 PM
Metadata
Fields
Template:
Building Plans
Street #
6479
Location
Beverly Hills Dr
Contractor
Lennar Home
Building Plans - Permit #
4164
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECOND FLOOR ELECTRICAL PLAN (ALL ELEVATIONS' <br />1 /4" = 1'-0" <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST 3' FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DENS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS ORAREAS SHALL BE ON AN A.F.C.I, <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />\/-R/ MAY 2 4 k <br />VIRTUAL REVIEW ASSIST <br />Virtual Review Assist, Inc. <br />Plans Review completed and appr <br />for compliance with the 2020 FD 7 <br />Edition by Debra Anne Klahr PX2300 <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />SWITCH <br />° <br />DOORJAMB <br />DUPLEX 19 <br />OUTLET �0 <br />TRIM <br />o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />oZ <br />S <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />11 OV DUPLEX OUTLET AT 12" <br />11 OV DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />11 OV DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />11 OV DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 11 OV DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />11 OV QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />11 OV DUPLEX FLOOR OUTLET <br />OUTLET -VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />STRUCTURED WIRE OUTLET <br />-69— SWITCH AT 36" <br />Cn <br />3 WAY SWITCH AT 36" <br />4 WAY SWITCH AT 36" <br />PUSH BUTTON FOR GARAGE DOOR OPENER <br />DIMMER SWITCH AT 36" <br />—0 PUSH-BUTTON DOORBELL <br />-t- CLG MNT LT FIXTURE <br />{ CLG MNT PREWIRE - FIXTURE BY OWNER <br />?} SURFACE MNT FIXTURE <br />{ } WALL MNT FIXTURE <br />T NOTE: <br />C TUB/SHOWERND OPALEX - ALTERNATE <br />CANS MAY BE <br />I 5OW PAR30 NFL 6" WHITE BAFFLE USED IF <br />C APPROVED BY <br />60 50W MR16 4" LOW VOLTAGE OWNER <br />50W PAR20 NFL 4" MINI ROUND RECESS <br />�� 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBALL <br />{- CLG FAN PREWIRE AND SWITCH <br />Cs COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />cU-18= UNDER CABINET 18" <br />rS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= <br />SINGLE 24" FLUOR STRIP <br />=D-24= <br />DOUBLE 24" FLUOR STRIP <br />= U-36 = <br />UNDER CABINET 36" <br />= S-36 = <br />SINGLE 36" FLUOR STRIP <br />= D-36 = <br />DOUBLE 36" FLUOR STRIP <br />S-48 <br />SINGLE 48" FLUOR STRIP <br />— D-48 <br />DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />48 48"CLG MNT WRAPPED FLUOR LIGHT <br />FF24:R 24" VANITY LIGHTING <br />FFFF 36 :FFR 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />® EXHAUST FAN/LIGHT <br />0 EXHAUST FAN <br />DOUBLE FLOOD LIGHT W/ COVERS AND <br />150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />M CHIMES (DELETE W/ INTERCOM) <br />MASTER STATION <br />ELEC PANEL <br />VACUM OUTLET AT 12" <br />® CEILING RETURN AIR <br />A/C REGISTER <br />(D THERMOSTAT <br />IIB SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />E <br />50 0 <br />M <br />N <br />V O u <br />a <br />=o <br />:) o 2 <br />o <br />0LL0 aQ <br />V1 <br />U LU <br />c�c N C <br />M <br />W <br />O C <br />(' LLI <br />�iuFw.. W <br />1- � J <br />w <br />w2�p <br />� Z W Z <br />j <br />QD� JwO��<u.UOo0 <br />aCDXWOz0wO0mzZ <br />Jo <br />(� O <br />C0 <br />O <br />Z <br />.30d>zY00ZzLLLuz00W <br />0 CL <br />¢ <br />U_ <br /><0WpEP� <br />OW o D <br />Q <br />2W620 <br />o<<W <br />LL O <br />LL <br />O <br />tV <br />Z <br />OLU <br />(n 0 <br />� M O <br />U M � <br />uLL � <br />Q W QLq <br />_M <br />� <br />Z <br />� <br />U <br />z <br />W <br />W <br />J O <br />CO <br />I <br />I <br />I <br />I,X <br />I <br />I <br />L0 <br />O <br />O <br />o <br />O <br />0 <br />O <br />0 <br />N <br />0 <br />N <br />N <br />0 <br />N <br />N <br />N <br />r` <br />O <br />\ <br />\ <br />N <br />O <br />0 <br />O <br />O <br />N <br />N <br />z <br />O <br />0 <br />Wo <br />> <br />� <br />N <br />0 <br />M <br />0 <br />'It <br />o <br />to <br />I <br />I <br />00 <br />z <br />(%� <br />Q w <br />O <br />W <br />woo <br />0 <br />V <br />UVv5 <br />Lo <br />-0 <br />ozj <br />ow- <br />0 <br />rl <br />Z <br />aF-a <br />W Q <br />Lri <br />= <br />m=Hw <br />2 <br />N <br />W <br />O <br />zo= <br />W <br /><F-D <br />cM <br />QO <br />ZWO <br />Z <br />() <br />LUW <br />Z LL <br />z <br />z <br />U <br />0 <br />_0 <br />W <br />z <br />z <br />z <br />� <br />J <br />LU <br />C, <br />Lo <br />0 <br />0 <br />LAST PLOT DATE <br />• . <br />March 29, 2022 <br />z <br />0 <br />2ND FLOOR <br />-- <br />ELECTRICAL PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.