Laserfiche WebLink
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL' FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3Ar° Ct:MEN I <br />PLASTER <br />12 M.L D('1VLOK CM(J MA90N12Y <br />ill OCK <br />EXTREME <br />WINCKTW <br />FASTFNFR -- - <br />+; " <br />1) SCA1 AKT AT <br />4) SFAI ANT .JOINT <br />' WINCK)W Rt ICK TO <br />O1.ITSi0E EDGE OF <br />"' ', <br />MASONRY <br />WINLK)W BUCK <br />2) SCALA14T JOINT <br />5} SFAI ANT FROM <br />'' '- <br />wsinr rncr m <br />WIN CW *V FRAME <br />^ + ' <br />.t WINDOW BUCK <br />Af.'RtOSS WONt)041W BMK <br />ANU L x I L NOMASONRY <br />r <br />, <br />r <br />PER CODE <br />4 <br />9) 1001 F1) Sf-AI AN <br />`sc <br />HERCOD44rNTS <br />BF -AO 171RI IINCI <br />' <br />CLADCWi AND W(NrX-)W <br />FRAMF <br />3) SEAUWT WINDOW FRAME T( <br />WINUUW BUCK ALL THE WAY <br />AiWMI). IN(,l UDING Sll L. <br />SCS 0605 C MU INSTALLATION 6 POINT LTUC:K AND <br />FENETRATION INSTALLATION AND INTERFACE <br />JAMB, NLI. AND HEAD DETAIL <br />;PPR(,NEU SHFATHINO <br />AF'PTTOVEDHOUSEWR,AP - • <br />STRUCTALATH TWIN TRACK 2.5 <br />3)4»CEMENi PLASTER <br />12 MII (m�nl DRYI OK rXTRI Mr <br />APPROVED FLASHING TAPE <br />'Y SEALAN T SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SCS 06 02 WINDOW FIN INTERFACF WITH <br />EXTRUDED SHOULDER <br />WEATHER <br />Itt.SISI 11VE <br />BARRIr n <br />•• •'� WEATHER <br />VE BARRIER d <br />tARiLY SFCURF <br />w <br />WOOD FRAME CONSTR ":4" <br />EXTERIOR SELF -ADHERED FLASHING <br />SHEATHING nY I APPING DOWN -� <br />OVFR RIM .101ST AND UP <br />WALL UY !! IN. <br />Wl_A I HLH , , <br />RESISITIVE <br />BARRIER SFAI TOPS CX ,JOISTS <br />UNUtk L*C:KINU <br />ED FLASHING (Sir MTAJI WP07) <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Out, fold up b temporarily secure weather <br />resistive barrier above header b allow for <br />flashing installation <br />2, Self adhered flashing plus head flashing under <br />weather resistive barrier I `y <br />3. Fold weather resistive barrier back over head 2 <br />flashing and seal vAlh tale <br />SELF -ADHERED FLASHING Scale. NITS <br />FLANGED WINDOW PM <br />1 <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SI IEATI IIW3 -- <br />iipF,`N TO TP(:MNK:AI <br />1 F 11 FM ON (:1-11-1,NCA1 <br />COMPATIBILITY <br />SELr-Ao1IcRCo rLASINNG -, <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />H AWiF <br />SELF-Al)ML-HI,U FLA8HIN(; <br />NAli NG I I ANOF <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as (#� in each dBt.Tli that corresparx#s to the <br />numbere(1 items in the list of instructions Delow: <br />1. install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive harrier to form water shedding <br />laps <br />3. Self -adhered flashing cal) be substituted for building paper <br />4. Split the release paper using the ripcord (Split release uo demand, <br />embedded in the adhesive layer) - for ease of installation ancf to <br />minimi7.e scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />ddlf to to substrate using d 15qutaie piece of flashiliq material (6" x 6" <br />Minimum) <br />6 Fold as shown by arrows, <br />7. Angle of corner may vary. adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />rvwnl,r,� <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />2x FRAMEWALL-- <br />TILE FINISH-- _ <br />1l2" DUROCK - ---�� <br />E <br />AM <br />WP07 <br />8"CMU dA <br />'�-- <br />4" OR R' CMU --- <br />(PER SEAT DEPTH)- - <br />FILL t,'VITH GROUT - <br />SLOPED MUD BED-- <br />-- <br />VINYL SHOWER PAN -=-- <br />�w <br />ALAI HLR RL515 iiYL <br />RARRIFR <br />-- - -WINDOW UNIT FLASHING REQUIREMENTS <br />UUOR ROUGH Ui'ENING <br />SLOPE <br />0.3 in : 12,0 in R703.1 Gene; Z11. Jinqwith a weather reistant exterior wall envelope The exterior wall envelope shall <br />-is--t~RFnrsc,r crxJsr;< (0.6 um. 30.5 (:rn} in flashing a3 is .' <br />ADHESIVE TO BE APPLIED UNDLII ---- SELF -ADHERED FLASHING <br />TIiRfSHni D Or DOOR AND RETURN UPJAMB 6"- USE LIUUID R703.1.1 Wat:-,r rl sa t,,; , 1 r,. c-*xtt?rir,i• :.i#I envrinple mall be dosi noel and constructed in a manner that prevents the accumulation of water <br />NAIL 15HANUON4WAL. WLAIHkH EXTFRIOR <br />a <br />PRO(YCAULKING __..__.CENT. FIN. within the wa�� ,ernkiy y providing a vr�ater-TesistarTt i.arli l k�+slrind the exterio� r I:j:.idin<� as required by Section R703.2 and a means of <br />.- sIA F-A191FRI-n r I ASHING BUILDING PAPER draining to the exterior water that penetrates the exterior ciadding. <br />-- > WIRF I ATH R703.2 Wate esistive barrier, One layer of No. 115 asphalt felt, free from holes and breaks, complying with ASTM 0226 for Type 1 felt or other <br />srusFLu+rHapproved wa' (-resistive barrier shah be applied over to+�s or sheathing of all exterior Walls No. 15 asphalt felt shall be applied horizontally, <br />with the uppE- la,• - apped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 inches. Other <br />\1 <br />approved ma :.hail be installed in accordance with the water -resistive barrier manufacturers installation instructions. The No.15 asphalt <br />RIM JOIST t felt or other 3pprci red water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and building <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />FXTERIOR S FATIANG <br />+ 4'-I' RFAD OF CONSTR <br />ADHESIVE TO BE APPLIED UNDER /� <br />TI Qf .;I101 D 0(.. rX-)0R AND RFT0RI, = " <br />UP JAMB tr, UuE LIUUIO NAIL 8HANL / <br />An romi WrATIrrA PRoor cAui icnc. ,. �� <br />SECT ION -A (SLr. DETAIL WP02) <br />14EI-F-ADHERE0 FLASHING <br />SEAL TOPS OF K)IyTS <br />UNDER DL(;NNU <br />(SEC DETAIL WP07) <br />SFLF-AI)HFRFr) Fl ASHINC',Y <br />EXTERIOR DOOR WITH DFCK <br />SELF-ADHER <br />� Q <br />_�- w <br />> <br />1'4" PER PLAN h Z <br />V-0" PER PLAN _ 'v <br />SHOWER SEAT <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />.'i <br />.: <br />z <br />1UJ <br />• <br />_. <br />Lu <br />U <br />w <br />cc <br />' <br />I <br />own <br />Ix <br />w <br />� <br />Ca <br />A .0 <br />a <br />, <br />WP1 1 <br />appendages a manner to meet the requirements of the exterior wali envelope as described in Section R703.1. <br />�''f ------ I R703.7.3 Wwk2tr•-r(.,i5tive Harriers Water -resistive barriers s hall be installed as required in Section R703.2 and, where applied over wood -biased <br />sheathing, sr -1. - _ t _ p p _ rneable barrier with a performance at least equivalent to two layers of Grade D paper. The <br />2D <br />!I Irl.c�iltrj� a '•�°�:•�tl+t-r>��•t'; tvr, v3 � rat- wt ' <br />individual layers shall be ,rtst,ulied Independently such that each layer- provides a separate continuous plane and any flashing (installed in <br />accordance with Section R70:3 a; interidec, to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />WP02CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER WP03 Exception: `JVhf.rir the water -resistive barrier that ;s applied over :rood hasc3d sheathing has a water resistance <br />equal to or gre;,tNr than thAl. c)f 60-minute Grade D paper and is separated from the stucco by an interveninc, <br />substantiai?y ncn;•,ratr;r absorttng layer or designed drainage space - <br />MECHANICALLY FASTEN IF t�Ut3BERl:.EG I2UE3BCri1ZED ASPHALT , <br />FLASHING JG I.F.A 8 HEAD NLLL) U IN UOHNERS SELF At1HEREl> ASPHALT ADHESIVE ADD (FSIVF <br />03.4 Flash i ti and mechanically attached flexible flashing shall be applied <br />•s <br />f-LAL'>'FIWCi.tiS:l FLASHING t----SEIr-AbHEFtEdFIL.7YSHItJG--,, R7- hi( I'i t: flashing,, vinyl fla'ytlln �clt L+ +- �"�ppr,.ve rT7etra a y, y g adhered rTterT)Lirane <br />FLANGEDWINDnW shingle fas a (:oldance v1ItIW1 the r(Iarlltfa(:turer Irt,;, . ctlans. Metal flashing shall be corrosion rrrsistant. Fluid -applied nTerTTbrarle5 <br />(SEE uC r ,i, ,tilAu,, J / ^- r • - p used as flash ' ; Belt be aprAied in a ardance with the WalUfacturer's ins#c uctiorls. All flashing shall be applied in a rnarTner to prevent the <br />., SCORED entry of water ;r1tc the wale c::avit•; or pen+,:trat,r-)rl c)t ;i;atei to tf)« building str-acturaf framing components. <br />RELEASE PAPER Self -adhered r,iembranc s used :as tiashing shall comply with. AAMA 711. Ail exterior fenestration products shall be sealed at the juncture with <br />- 317LF AEk *:Kt-0 IASHwc;. t i��+,:�_ -�� the budding v.:'. ',vith a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />CXTCNO A MINIMUM 6- ^C t44 rAr•r ^ T• , I at`CK;C a <br />�GHC"iNEI►5 a+CYr*r, contraction, V TrVIC1r$1. AAKIA 8 or 0hev apptovec standard as appropriate foi the type of sealant Fluid -applied membranes used as <br />VF R T IC:AI I Y Fitt )M <br />BOTTOM oc flashing in exterior wads shall s.tth AkNIA 114. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />IHRESHO(l3 <br />shall be instal�c.,r' at the• foliowing 1o,:ations: <br />pe gs • ve Lind door Ipenings shall extend to the surface of the exterior wall <br />1 finishorlIV.) wind tra(tde ladle barrier complying with Section103.2 for subsequent drainage. Mechanically attached flexible flashings <br />2 shoe comply +.°path A6rN4A 11 Fla5hin(i at exterior v it+��lo°e arc, dour openinca shalt be installed in accordance with one or more of the <br />j following <br />5 1." The fenestration inanufaicturer's rust;nation and flashing instructions, or for applications not addressed in the fenestration <br />4 manutacturor' ; instructions in accordance with the flashing manufacturer's instructions Where flashing instructions or details are <br />not provided. pan flasi-ling shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />6 sloped in SLI0l .a n`1.111( a to 614r C t '.later to the st_Irfaee of the exterior wall finish or to the water resistive barrier for subsequent <br />c' <br />2 ` (7) 1.2 <br />Openings using pan flashing shai incorporate flashing or protection at the head and sides. <br />1.2 1.2, In nceorc,ance with the flashing design or method of a registered design professional. <br />t J� �'j SELF -ADHERED FLASHING 1.3 1.3. In a�.:corcanc:e with other approved methods. <br />Y Y V -ADHEIDE CORNER 1 A in accordance with FMAiAAI't1A 100, FMA, AAL4A 2i')0, FMAiWOMA 250 F' N:IA/AAMA,` WDMA 300 or FMAiAAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other maso-try construction vrlth frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground 3 3 Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above .all f rojF+sting tivooc' trim <br />_ 5. 5.WI re t�xterior porches, decks or stairs attach to a wall or floor assemNy of wood -frame construction. <br />i (-,,� 4 6. 6.At . all and rout intcr_,rct+cn•; <br />--- w t H t t t3 7 7.At ,n ('lutterr. <br />-ADHERE:) FLASHl14(s _ <br />H <br />HLU I- LASHING <br />,2 <br />4 <br />WP08 <br />PLASTER STOP 144 <br />CONTINUOUS BACKER <br />HCN.I (3 :�At aN r' <br />�A <br />FOUNDATION WEEP SCREED <br />IJ <br />--SIkiP(* <br />DRAINAGI PLANL WRti <br />BOND BREAK WRB <br />SF LATH <br />- WRAP OP WRri ON rO <br />Tr IF VFRTICAI <br />st JRFA(:F TO TOP OF <br />F LANGE AS AN AiR <br />BAHRI1 Ft <br />� .. <br />3-1/7 INCH FLANGE <br />THIS <br />NATU <br />DO 1'N <br />- DRIB' <br />ACCE <br />SOFFIT/CANTILEVER <br />a ar I sIs kin all er <br />Lath <br />heathing <br />Stucco <br />THESE --)L'FAILS ARL (:-IENERIC; AND MLANT TO SHOW GENERAL <br />F LAA'HING AND WA•TERPROOHNG METHODS TO BE USED. <br />_ 7b-' Plaster <br />-' in ;_c;:d_ince.with <br />ASTMC�� <br />t r%d) l CIT43tF11 <br />,ti' , ' lathe In accordance <br />withASTtwtC1063 <br />mil rJ Uui)cing l}ape( <br />�• lh`, / <br />WP09 <br />^dcea Screed <br />II)gI Illed A�l po.;ll <br />LEGEND <br />51r1.1- AUHLItLU 1 LASHING RSAI) <br />DRAINAGI-Pi ANI (DP) Wr A1iiI_R RF SL%TANT <br />RARRIFR (WRR) <br />ROW) RRFAK WEATHER RESISTANT RARRIFR ---- -- <br />tirI i- rURRING (SF) LATH <br />Pt ASTFR ACCESSORY <br />stiEATli1NC.'OW. PLYWOOD. <br />STRUCTURAL FRANING <br />S t HUt:1 Vt'LAl :;r•t r_� r Htty� ) <br />Sifill' % SAF <br />DRAINAGE PI AN(" V/Rri <br />ROND PAFAK WR8 <br />SF I AT]I <br />l' 1 <br />_ ManlJtact. Specs. <br />Mainoin <br />~` a tt •Tl f <br />O a O <br />Weep Screed <br />1 1 i2' to 2" <br />Above Roof <br />S ITBa' hing <br />�%. <br />Cement <br />in accoa <br />with ASl l <br />over WO( <br />floor <br />1 <br />•� I <br />i <br />r <br />I <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Fell hacked metal <br />lathe in accordance <br />with ASTMC 1063 <br />Building Paper <br />7116" O.S.B. <br />Sheathing <br />-v <br />N <br />} <br />U <br />o <br />. CJ] <br />U <br />+-• <br />cA <br />CL3 <br />O <br />-0 <br />O <br />co <br />-0 <br />� <br />O <br />a <br />� <br />o <br />.0 <br />LL <br />cu <br />O <br />a+. <br />O <br />> <br />•� <br />-0 <br />� <br />CD <br />Qi <br />LZ <br />O <br />♦'' <br />0O <br />t�. <br />Q <br />CZ <br />Q <br />�J <br />V J <br />0 <br />7.�i.I..I. <br />V <br />CL <br />co <br />w <br />Q <br />z <br />z <br />-, _Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufm-t. Spet,-s. <br />1Z Cementitious <br />Decorative Finish <br />All inside and <br />-'f outside comer will <br />i feed to be miter <br />rout and caulked all <br />00.butt joints need to <br />becaulked using <br />• . Stampede Vi sire. <br />caulk for II <br />AAY 2 4 2022 <br />AL VIEW ASSIST <br />I Review Assist, IncQD <br />1,3 Review cvmple'ad p ve <br />Note: <br />The building paper and metal lath IT) d' <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCAI F. NOT TO SCALE <br />pith the 2020 BC th <br />Amine Klahr PX2 0 <br />WPT <br />