THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT, <br />METAL LATH WALL SHEATHING <br />16GAx1-1,2" LONG (3r'4„-1" CROWN') <br />I i Mdx6,C.C. ERT BETWEEN l i I 16GAx1 1/2" LONG 3/4"-1" <br />STUDS (NOTED THUS.—) - OFFSET p I I I CROWN) STAPLES a= 61' <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:-) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24,21 SCALE: 314" = 1'-01 <br />`DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR7C13.7.1 LATH- <br />­ONLY APPLIES TO LENNAR TPA,'JAX** <br />LATHING ACCESSORIES: <br />ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. <br />WOOD APPLICATION: 16 GA. x 1-1/2" LONG (3/4%1" CROWN) STAPLES @ 6" O.C. <br />VERTICALLY/HORIZONTALLY INTO FRAMING MEMBERS. <br />MASONRY APPLICATION: CONCRETE STUB NAIL, 3/8" (10 MM) HEAD DIA. MIN. @ <br />6" O.C. VERTICALLY/HORIZONTALLY OR COMPATIBLE ADHESIVES, EXTERIOR <br />GUN -GRADE, CONSTRUCTION ADHESIVE WITH 1" DABS @ 6" O.C. OR IN A <br />SEMI -CONTINUOUS BEAD BETWEEN THE SOLID PLASTER BASE AND THE SOLID <br />PORTION OF THE KEY ATTACHMENT FLANGE. <br />CONTROL JOINTS: INSTALL CONTROL JOINT LATHING ACCESSORIES IN <br />CONFORMANCE WITH C1063. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS, BUT SHALL BE STOPPED AND TIED AT EACH SIDE. <br />ALL ACCESSORIES SHALL BE IN ACCORDANCE WITH THE LATEST ASTM C1063 & <br />ASTM C1861. <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />STUB -OUT FOR "' <br />GAS METER O <br />CV <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS" <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'4" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />*TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />c7' <br />w <br />in <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + o <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ 4 <br />+ + <br />+ '-0(TP.) <br />4'-0" <br />4'-0" <br />++ <br />+ <br />+ + <br />++ <br />+ + � <br />++ <br />+ <br />+ <br />+ <br />+ + <br />++ <br />+ + <br />+ <br />+ <br />++ <br />+ <br />++ <br />++ <br />++ <br />+ ++ <br />+ <br />+ + + + + ++++ + <br />+++ <br />+ +++++ <br />+ + <br />+ + <br />++++ <br />+ + <br />+ + + + + ++ <br />+++ <br />+ <br />+ <br />+ + + + + + + + co++ <br />+ + + + + + + . + + + <br />1�1++++++ <br />+ + <br />++ <br />+ <br />+ <br />+ <br />15/32" CDX I <br />PLYWOOD OR <br />7/16" OSB <br />`—RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH ON 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH 2-3/8 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x- <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x — lumber <br />Double 2 x — lumber <br />FILL CELL <br />STD. 90° HOOK BOND BEAM <br />BOND BEAM STEP <br />- CONT. #5 <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min.) Small 2" min. <br />2" <br />gap <br />max. � 4 max. <br />Clinch nails <br />when <br />IkA�' possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4 Place joists together and nail from each side with 2 rows of 10d nails 2x4lPiywood/OSB web stiffener 2"min. <br />g required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGYa" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />t. <br />DOUBLE JOIST CONNECTION top irdsmouthcuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor col,,mn w/ lnn iQ <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />--- <br />code for appropriate <br />1116" <br />Zor-20 <br />details in <br />One 10d box <br />areas=20 of high <br />N <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking r <br />1/8" gap + <br /># 11 <br />Boise Joist Blocking <br />I lca T' N0d) nails at R" n c <br />1 i/ Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.— <br />U)OEM. J r% <br />A %" ROUND HOLE MAY DO NOT CUT HOLES <br />6 BE CUT ANYWHERE IN 6 6' CANTILEVER LARGER THAN 1Yz" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />Round Hate Diameter (in) <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />&875 <br />10 <br />11 <br />12 <br />13 <br />Rectangular Hole Side (in) <br />2 <br />3 <br />5 <br />6 <br />8 <br />9 <br />10 <br />Any 16" joist <br />Span (rt) <br />8 <br />V-0" <br />1 `-1 " <br />1 "-2" <br />1'-2" <br />V-3" <br />V-3" <br />V-7" <br />1'-11" <br />2'4" <br />2'-9" <br />3'-2- <br />3'-7- <br />12 <br />V-0" <br />V-1" <br />V-2" <br />1"-2" <br />V-3" <br />V-9" <br />2'4" <br />2"-11" <br />3'-7" <br />4'-2- <br />4'-9- <br />5'4" <br />16 <br />1'-0" <br />V-1" <br />1'-2" <br />1'-2" <br />1'-7" <br />2'-5" <br />3'-2" <br />3'-10" <br />4'-9" <br />5'-7" <br />6'4" <br />7'-2" <br />20 <br />1'-0" <br />V-1" <br />1' _2" <br />1`-2" <br />2"-0" <br />3'-0" <br />4'-0" <br />4'-10" <br />5'-11" <br />6'-11" <br />7'-11- <br />W-11- <br />24 <br />1'-0" <br />V-1" <br />1'-2" <br />1`-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />5'-10" <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BC15000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5- <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC160s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />wl(22) <br />NAILS l <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/(22)' <br />NAILS l <br />R TRUSS <br />'OP PLATE <br />l.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />Joist <br />When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to.top flange. <br />Joist <br />1111 \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mo-nt" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />•�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18) 10d x 1 1/2 ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />PLUMBING LINE <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE PVC OR SCH40 SLEEVE <br />A/C CHASE 4" PVC PENETRATION <br />SLEEVE THRU STEM <br />d ° <br />WALL 4 ° . a <br />_ I I ° <br />1-111�111=1 1-1 1 1 a. a: .111 I I <br />-111—I I I-1_ 1_I I I —I 1I- <br />_I I-1I-1I I III FINISH GRADE -III 1 —III_ <br />SLEEVE THRU STEMS <br />SEE PLAN FOR <br />FOUNDATION INFO <br />STEM FOUNDATION <br />GRADE REINF. SEE PLAN <br />a <br />. * <br />1 ,,111 �,111, <br />H/L, LI iHJt 4' VVU <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />1 1 <br />I ILI 11 L __ _� <br />Il-- SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />%rtuat Review etedt <br />plans Review com he 202 <br />fat compliance with <br />nebra Anne 'tat <br />TOP (2) #5's x 4'-0" PVC OR SCH�I SLEEVE <br />CENTERED @ PIPE PLUMBING LINE <br />i PENETRATION <br />�7 . .. .. . <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @PIPE <br />PENETRATION PLUMBING LINE <br />I —III —III: <br />a / II I ITI 1- <br />a-d------�' <br />SEE FND. PLN. <br />SIZE & REINF. <br />CM <br />N <br />0 <br />a <br />N <br />LO <br />4 <br />LO <br />®, <br />"D <br />00 <br />LO <br />U. <br />0', <br />I >e�` A <br />w <br />Ile, <br />w <br />z <br />Q <br />nN <br />W > O F� o <br />W <br />L 'r- "o o U <br />M cq N 5 <br />M <br />to <br />*- N <br />P - <br />V Q L° M <br />E L <br />2 <br />_ <br />0�8 m¢ <br />U <br />•LO` <br />p� < <br />W C1N <br />cc)O E� P <br />-TW <br />v <br />L <br />a <br />wV <br />❑w 17 wOI- <br />~X2JQWQz0zW x JQO�OOJO <br />— fncy v7LL3� <br />0:X° <br />0mZ= <br />(n00X00 <br />X— <br />a 00U_ 0 <br />(n Z <br />73 <br />JOo->zY❑Zz'lOWOo- <br />¢0W0i <br />�_gwp2U°¢ <br />OQ o 0Qz§Q <br />0 Q LL <br />0 <br />0 <br />Z N <br />OW <br />U) J ti <br />O <br />M <br />Q U) M � <br />2 U) <br />LO <br />QO <br />Z U <br />W <br />LU <br />W O <br />J <br />� <br />2023 <br />mi <br />N <br />N <br />N <br />N <br />N <br />N <br />ti <br />4'4 <br />Inc.O <br />CV <br />O <br />CV <br />O <br />nd approved <br />frBC 7th Edition <br />PX2300 <br />q <br />o <br />0 <br />c6 <br />o <br />T <br />CO <br />CO <br />CD <br />C) <br />C:) <br />NO <br />f <br />O <br />NO <br />C)C <br />0 <br />� <br />0 <br />N <br />0 <br />N <br />O <br />N <br />CV <br />CN <br />N <br />CA <br />N <br />O <br />LO <br />—1O <br />00 <br />O <br />CM <br />e� <br />r <br />CN <br />O <br />M <br />C)0 <br />C <br />0 <br />O <br />0 <br />O <br />O <br />0 <br />0 <br />LO <br />> <br />M <br />LO qt <br />N <br />d <br />LO <br />(fl <br />1` <br />1 0- <br />CO V) <br />Z z <br />O <br />w <br />�-a <br />0 (nn <br />(.) <br />1.-0�a <br />-0Owof <br />UJI <br />�a <br />Q <br />ZIXI.- <br />IX <br />=coo <br />fnLU <br />Z <br />CN <br />v <br />J <br />M <br />�zz� <br />UM)w <br />N <br />O��z <br />> <br />v�ZU) <br />. <br />z <br />�QO <br />z <br />U <br />U <br />J <br />0 <br />_011 <br />W <br />� <br />Q <br />z <br />SN1J <br />Z <br />z <br />'^ <br />LLI <br />M <br />O <br />O <br />LAST PLOT DATE <br />May. 9, 23 <br />Z O <br />STRUCTURAL <br />— J <br />DETAILS <br />