Laserfiche WebLink
ROOF FLASHING AND ROOF FLASHING <br />COMPONENTS TO BE IN ACCORDANCE <br />w/ R903.2, FLORIDA BUILDING CODE <br />7TH EDITION (2020) RESIDENTIAL <br />12 <br />�P') VARIES <br />l iL <br />5/8" OR 1/2" HIGHS <br />STRENGTH CEILING <br />BOARD PER CODE (OR 5/8" <br />GYP. TYPE "X" @ GARAGE <br />W/A HABITABLE ROOM <br />ABOVE) W/DRYWALL <br />SCREWS @ 7" O.C. <br />CEILING & 8" O.C. WALLS <br />INSULATION PER —� <br />CHART ON FLOOR <br />PLAN <br />1x2 P.T. HORIZONTAL <br />NAILER <br />STD. 90-HOOK (SEE DETAIL <br />2x BLOCKING HORIZONTALLY@ <br />2x #2 SPF STUDS INTERVALS NOT EXCEEDING <br />@16" O.C. W/ (2) 10'4' (R302.11) <br />FOR UNDERLAYMENT 16d TOENAILS T & B <br />REQUIREMENTS SEE R905.1.1 1/2" GYP. WB (MIN.) @ GARAGE SIDE IF z <br />PRE ENGINEERED WOOD APPLICABLE. <br />TRUSS @ 24" O.C, U.N.O. 2x P.T. PLATE 1/4" DIA. X 31/4" TAPCONS @ 24" O/C & ci <br />HURRICANE ANCHOR @ EACH @ 6" MAX FROM END OF 2 x PLATE <br />TRUSS (SEE UPLIFT SCHED.) W/ (2) #5 CONT. ON 3° 6,, 6 W1.4 x W1.4 N <br />METAL PL. UNDER EA. TRUSS CHAIRS (TYP.) WWF OR FIBERMESH <br />MOISTURE BARRIER ° <br />SHINGLE ROOF, SHINGLES TO A o <br />BE IN ACCORDANCE w/ ASTM =I I I =I I °' i �I <br />D7158-CLASS G or H, or ASTM TI I I T I C 1 L I *- <br />D3161-CLASS F, IN -.Al <br />° • _ I I=I II ( <br />ACCORDANCE w/ TABLE -I -' ' I I I I_I I ��I I —I I —I I — 171 I f;;:;I <br />R905.2.6.1, FLORIDA BUILDING11 <br />CODE 7TH EDITION (2020) 8 -1 III 11 i I I I I I I I= I l <br />RESIDENTIAL <br />ROOF SHEATHING - SEE <br />SCHEDULE - [RSH] - ON TYPICAL INTERIOR BEARING <br />FRAMING SHEET FOR <br />SHEATHING AND FASTENERS I WALL w/ OUT UPLIFT GG <br />ELEV. VARIESk I SEE TYP. WALL SECTION SCALE: 3/4"=V-0" S3 <br />ALUMINUM DRIP <br />EDGE <br />ALUMINUM FASCIA <br />" N.O. 2x SUB FASCIA <br />EE STRUCTURAL <br />SOFFIT SHEET SS <br />8"x8"X16" KNOCK -OUT <br />BLOCK W/ 1#5 CONT. <br />FILLED SOLID W/GROUT <br />,1_____8" C.M.U. TYPICAL <br />TYPE "S" MORTAR <br />ARCHITECTURAL <br />FINISH <br />1x2 PT WD FURRING @ 24" O.C. <br />1/2" GYPSUM WALLBOARD <br />U.N.O. <br />(1) #5 VERT. IN FILL <br />CELLS (SEE <br />FOUNDATION PLAN <br />FOR LOCATIONS) <br />1x4 P.T. BASE NAILER <br />4'l INSPECTION <br />3 1/4" BASEBOARD <br />PORT AT EACH <br />FILLED CELL TYPICAL <br />MIN. 2500 PSI CONC. SLAB <br />cf) <br />AT GARAGE CONTRACTOR <br />MIN PSI MAY VARY PER <br />TO CUT BLOCK OR POUR <br />MUNICIPALITY. <br />CURB DUE TO SLOPE <br />CONCRETE SLAB W/ 6X6 <br />0- <br />NOTE:EXTEND <br />W1.4XW1.4 WWF OR <br />wl <br />DECO FINISH 4" to 6" <br />"FIBERMESH" <br />BELOW GRADE <br />2 <br />E - <br />.00 <br />r, <br />- <br />o <br />00 <br />6 MIL VAPOR <br />a <br />I I— z <br />BARRIER <br />Dcli <br />COMP. SOIL. <br />(COMPACTED TO 95% I TT"'1T�1 <br />MODIFIED PROCTOR <br />ASTM D1557) <br />3" MIN. CLR. <br />(2) #5 REBAR CONT. 1'-4" (1 STORY) STD. 90 HOOK (SEE <br />ON 3" CHAIRS TYP. U.N.O. 4" 1'-8" (2 STORY) DETAIL) <br />TYPICAL WALL SECTION rA <br />SCALE: 3/4" = V-0" S3 <br />OPT: DEPRESS SLAB 5Y2" <br />DEEP AND 6" BEYOND <br />DOOR TO RECEIVE <br />PAVERS / DRIVEWAY <br />CONCRETE SLAB --\ <br />BLOCK WALL BEYOND <br />— 1411 O.H.D. RECESS <br />�• z_ <br />M � <br />• -- <br />" - <br />.. 4 00 <br />.a <br />SEE A/S3 OR J/S6I M r, <br />FOR REINF. INFO. 3" MIN. CLEARANCE <br />1'4" (1 STORY) / V-8" (1 STORY w/ DEPRESSED SLAB OPT.) <br />1' 8" (2 STOR) ) <br />GARAGE DOOR SLAB RECESS J.1 <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />7)"IF <br />I I I I <br />,1l <br />,/r <br />5/8"OR 1/2" HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 #2 SPF 5/8"OR 1/2" HIGH STRENGTH TRUSS BOTTOM CHORD OR 2x4 #2 SPF <br />(U.N.O.) (OR %" GYP. TYPE "X" @ BLOCKING @ 12" O.C. w/ (2)12d TOE NAILS e „ „ BLOCKING @ 12" O.C. w/ (2)12d TOE NAILS <br />GARAGE W/A HABITABLE ROOM <br />GARAGE W/A HABITABLE ROOM EACH END (WHEN PARALLEL) .) (OR / GYP. TYPE X„ @ EACH END (WHEN PARALLEL) <br />ABOVE) SEE UPLIFT SCHEDULE FOR UPLIFT GARAGEABOVE) SEE UPLIFT SCHEDULE FOR UPLIFT <br />S.P.F. DOUBLE CONNECTIONS. CONNECTIONS. <br />8"x8"x16" NOMINAL BLOCK WITH TOP PLATE S.P.F. DOUBLE <br />3/8" MORTAR BETWEEN COURSES SIMPSON SP2 w/ TOP PLATE <br />(12)10d NAILS 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. U.N.O. SIMPSON SP2 w/ 2"x S.P.F. (OR EQUAL) STUDS @ 16" O.C. <br />1/2" CDX PLYWOOD OR 7/16" O.S.B. (12)10d NAILS U.N.O. <br />SHEATHING REQ'D. FOR ALL 2x BLOCKING HORIZONTALLY@ INTERVALS 5/8"° x 10" "J" BOLT @ 24" O.C. w/ 2x BLOCKING HORIZONTALLY@ INTERVALS <br />EXTERIOR OR SHEAR WALLS AS NOT EXCEEDING 10'-0" (R302.11) 2"°x3/16" PLATE WASHER (TYP.) NOT EXCEEDING 1Y-0" 11) <br />INDICATED ON THE PLAN. ATTACH (ALT: 1/2"x12" TITEN HD @ 24" <br />SHEATHING W/ 8d COMMON NAILS @ O.C. OR 5/8"x10' WEDGE ANCHOR <br />4" O.C. @BOUNDARIES, 6" O.C. @ NSULATION PER CHART ON FLOOR PLAN @ 24" O.C.) NSULATION PER CHART ON FLOOR PLAN <br />3/8" MORTAR BETWEEN EDGES, AND @ 12" O.C. @FIELD <br />SLAB & BLOCK SIMPSON SP1 w/ (10)10d NAILS SIMILAR AT FOUNDATION ONLY„ SIMPSON SP1 w/ (10)10d NAILS <br />x 10" "J" BOLT @ 24" O.C. W/ IF NOTED, THIS REFERS TO THE <br />::1 F2-016" PLATE WASHER (TYP.) STEP, SIZE OF FOUNDATION AND <br />°' ELEV. 0'-0" OIL (ALT: 1/2"xl2" TITEN HD @ 24" 2x P.T. BOTTOM PLATE REINFORCEMENT AND WILL NOT 2x P.T. BOTTOM PLATE <br />O.C. OR 5/8"x10' WEDGE ANCHOR INCLUDE THE WALL <br />A.F.F. <br />zf� <br />@ 24" O.C.) 2" x 6 W1.4 x W1.4 ATTACHMENTS 2'� 6 x 6 W1.4 x W1.4 <br />WWF OR FIBERMESH WWF OR FIBERMESH <br />_ z 31/2" MIN. 31/2" MIN. <br />_ ELEV. 0 31/2 <br />_ A.F.F. o <br />2x4 CONT. U_ <br />1/2"(min.)- 4" <br />•' , ;000 <br />GARAGE DEPTH VARIES 31/2"(min.)I I — I 31/2"(min.) - 4" <br />(2) #5 CONT. 4„ 1,4, 8„ (2) #5 CONT. 4" ' '-0' g <br />GARAGE SLAB AT STEP B U.N.O. MIN. TYPICAL BEARING WALL STEP <br />TYPICAL BEARING WALL STEP SHEARWALL C @ CC <br />SCALE: 3/4"=V-0" S3 "SHEAR WALL" SCALE: 3/4"=V-0" S3 SCALE: 3/4"=V-0" S3 <br />1/2" OR 7/16" OSB MIN. PLYWOOD SHEATHING <br />NAILED W/ 8d COMMON NAILS @ 4" O/C <br />2x S.P.F. STUDS @ 16" O.C. BOUNDARIES, 6" O/C EDGES, AND 12" O/C FIELD. <br />-,01 � <br />ems• <br />2x STUD <br />SHEAR WALL REQUIRES 2x BLOCKING @ SEAMS. <br />2x STUDS @ 16" O/C <br />J <br />10 M `� s <br />LOAD BEARING OR <br />INSULATION PER FBC AND ENERGYGo`�� <br />EXTERIOR WALL <br />8 C.M.U. <br />FORM SUBMITTED WITH PERMIT <br />1"x P.T. STUD <br />2x BLOCKING HORIZONTALLY@ <br />APPLICATION <br />#5 VERT. IN FILLED CELL <br />INTERVALS NOT EXCEEDING <br />10' 0" (R302.11) <br />7/8" STUCCO FINISH PER ASTM C. 926 APPLY 3 <br />SEE CC/S3 OR N <br />LAYERS W/ TOTAL THICKNESS 7/8" OVER <br />G/S3 FOR ANCHOR <br />"J" <br />5/8"° x 10" "J" BOLT 24" O/C W/ 2"°X 3/16" <br />°� <br />METAL LATH. FIRST 2 LAYERS 3/8" THICK EACH. <br />CONTINUOUS TO FOOTER BELOW 90 HOOK DETAIL <br />BOLT INFO. <br />5/8"x6" BOLTS BOLT <br />PLATE WASHER TYPICAL <br />3RD LAYER 1/8" THICK. <br />K.O. BLOCK <br />(IF NO UP LIFT ON <br />@ 24" O.C. VERT. OR <br />WALL SEE GG/S3) <br />5/8" x 6" EPDXY BOLT OR <br />MIN. 2500 PSI CONCRETE SLAB W/ <br />SIMPSON SP1 w/ (10)10d NAILS @ EA. STUD <br />*SIMPSON SP1 <br />(6)1/4"x31/4" TAPCONS <br />SPACED EVENLY <br />6 x 6 W1.4 x W1.4 WWF OR <br />2X PT PLATE <br />20" MIN. LAP [24" MIN. LAP] <br />#5 REINFORCING <br />w/ (10)10d NAILS <br />r <br />2x P.T. PLATE <br />FIBERMESH <br />WEEP SCREED INSTALLED <br />BAR <br />TYP <br />ASSUMED FINISHED <br />E <br />PER MFR INSTRUCTIONS <br />OR #4 REINFORCING BAR <br />e i <br />GRADE <br />N � • > . <br />z_ <br />#3 & #4 LAP SPLICE <br />GRADE 40 MIN, 760ksil <br />MONO OR STEMWALL <br />z <br />° .D <br />A o <br />FINISH GRADE O0 <br />25" MIN. LAP [30"MIN. LAP] <br />[GRADE 60 MIN. <br />FOOTING MONO SHOWN L <br />FOR CLARITY <br />°O <br />- <br />_— <br />— <br />6 MIL VAPOR BARRIER — t. ° <br />— ° <br />- <br />— — I — O° <br />.- <br />N <br />#5 REINFORCING BAR <br />R 1 7/8 r <br />— <br />NOTE: <br />SEE SECTION C/S3 FOR <br />ADDITIONAL INFORMATION <br />SIMPSON SP1 w/ (10) <br />10d NAILS <br />2x P.T. PLATE <br />SPACE ANCHOR <br />a BOLTS 6" MAX FROM <br />o END OF 2" x PLATE <br />Lu p <br />U <br />° <br />� ����iIIIITI <br />W <br />2x BLOCKING HORIZONTALLY@ <br />INTERVALS NOT EXCEEDING <br />1 V-0" (R302.11) <br />1/2" GYP. WB (MIN.) @ GARAGE <br />SIDE IF APPLICABLE. <br />5/8"DIA. EXPANSION BOLT @24 " <br />O.C. W/ 7" EMBEDMENT (MIN. SHEAR <br />3500#, MIN. TENSION 2600#) <br />6x6W1.4xW1.4 N c� _ <br />WWF OR FIBERMESH <br />�11 T,11 I :o Ili—, <br />�11!�oeo�ua�� <br />—. — i #5 LAP SPLICE (2) #5 CONT. =I ILmI11,�r11 I111 II <br />NOTE: V <br />iti n e . — 36" MIN. LAP [36" MIN. LAP] ON 3" CHAIR <br />'FOR BEARING WALL _ r COMP. SOIL. (COMPACTED TO — ( ) 8" 1'�" 8" <br />W/ UPLIFT ONLY _ 95% MODIFIED PROCTOR ASTM — — NP' 10" <br />- D1557) m #6 REINFORCING BAR #5 STD. 90 HC OK <br />4" 1'4„ <br />-'#6 LAP SPLICE <br />TYPICAL INTERIOR BEARING <br />FRAME WALL TO C.M.U. WALL CONNECTION r u_� TYPICAL EXTERIOR FRAME WALL FOOTING <br />SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=V-0" S3 <br />SLAB INFORMATION. <br />11 6x6W1.4xW1.4 <br />31/2" WWF OR FIBERMESH <br />min.) 4 <br />"v GRADE <br />00 _ _ _ _ ° • <br />_ -(1) #5 REBAR w/ OPT. <br />' —T—III—III— I — t .1I I I 1=SCREEN ENCLOSURE <br />MIN. <br />TYPICAL THICKENED SLAB EDGE r�L <br />SCALE:3/4"=V-0" S3 <br />EXPANSION JOINT BLOCK WALL BEYOND <br />13" <br />O.H.D. RECESS <br />a w <br />—III—I I I OP <br />III —III .a .,,,•,�'. <br />SEE A/S3 0R J/S6— -IJ.II I I I riJ1,,, II I1-11= <br />FOR REINF. INFO. L 3" MIN. CLEARANCE <br />V-4" (1 STC RY) <br />V-8" (2 STC RY) <br />GARAGE DOOR SLAB RECESS J <br />SEE TYP. WALL SECTION FOR SCALE: N.T.S. S3 <br />ADDITIONAL INFORMATION. <br />SEE TYP. WALL SECTION FOR ADDITIONAL SCALE: 3/4"=1'-0" <br />SLAB INFORMATION. <br />P.T. 2x 1/2" GYP. BD. <br />HOLD GYP. BD. <br />1/2" FROM SLAB <br />0 CONT. BEAD SEAL0 <br />INTERIOR <br />A. . -31 /2" <br />CONCRETE NAILS W 1 1/2 <br />J EMBEDMENT @ 12" O.C. <br />STAGGERED, FROM BOTTOM <br />PLATE TO CONCRETE <br />(MIN. SHEAR 180# MIN. <br />TENSION 120#) CONCRETE SLAB <br />Aid <br />ao c <br />' Eii-_4T <br />- <br />N <br />M 6 MIL VAPOR <br />BARRIER <br />REBAR DETAILS <br />F <br />WALL w/ UPLIFT <br />rG <br />SCALE: N.T.S. <br />S3 <br />SCALE: 3/4"=1'-0" <br />S3 <br />„ VARIES <br />SEE PLAN <br />FRAME -DOWN FALSE BEAM w/ (3) SEE ROOF PLAN <br />10d NAILS TO TRUSS TOP CHORD FOR TRUSS <br />AT 24" O.C. MAX. CONNECTION INFO <br />SEE PLAN FOR <br />1 lf2 RECESS FOR <br />S.G.D. (U.N.O.) <br />6 x 6 W1.4 x W1.4 <br />WWF OR FIBERMESH <br />° <br />TOP OF BEAM IV &LAYOUT DESIGN <br />- <br />SEE ROOF PLAN <br />f, <br />c — — — —° °' ' ° '' ° c : ° <br />(2) HTS20 FOR STRUCTURAL <br />r <br />rLT�, rT�, R T� I T� . E <br />BEAM SIZE & <br />CONNECTION INFO <br />r 1 Tu..e 4 a <br />PLATE <br />0.5.8. <br />COLUMN LOCATION <br />M _ • • 7-- <br />T <br />2x4 #2 SYP P.T. FRAMING w/ <br />r_* <br />SEE A/S3/J/S6 <br />MIN 7/16" O.S.B. SHEATHING <br />z <br />ATTACHED PER NAILING <br />FOR REINF. IN. <br />OPTION #1 <br />w <br />SCHEDULE <br />a <br />SEE TYP. WALL SECTION FOR ADDITIONAL <br />J <br />SEE PLAN FOR STRUCTURAL <br />SLAB INFORMATION. <br />w <br />COLUMN SIZE AND BASE <br />o <br />W <br />CONNECTION INFO. <br />SLAB STEP & RECESS 6@ S.G.D. M <br />cn <br />SCALE:3/4"=1'-0" S3 <br />2X STUDS @ 24" O.C. U.N.O. <br />SECURE 2x4 P.T. BTM. PLATE <br />SEE DETAIL 16/D1 FOR <br />w/ 1/4"x3" TAPCONS <br />� MASONRY WALL AND <br />GARAGE <br />COLUMN TO PORCH SILL <br />AT 8" O.C. <br />PAD FOOTING <br />ATTACHMENTS & 18/D1 <br />1/2" GYPSUM WALLBOARD U.N.O. <br />FOR COLUMN TO BEAM <br />TRIM PER PLAN <br />8" MASONRY WALL <br />-- <br />W/ DRYWALL SCREWS @ 8"O.C. <br />ATTACHMENTS <br />EXTEND FILL CELLS l _ <br />TO FOUNDATION PAD d <br />INSULATION PER CHART <br />z <br />SQUARE CMU BLOCK BASE, <br />CONT. FOOTING STEEL <br />MAT REINFORCING. �' ' <br />r <br />ON FLOOR PLAN <br />w <br />o <br />SIZE VARIES PER PLAN <br />IllCONT. <br />BEAD SEALANT c <br />¢ <br />j <br />w/ MIN. (2) #5 VERTICALS <br />? <br />GRAD <br />> <br />_j <br />FILLED SOLID (SEE PLAN FOR <br />6 x 6 W1.4 x W1.4 N <br />LU <br />w <br />SIZE AND REINFORCEMENT) <br />c� <br />' <br />• <br />= - <br />iq <br />' <br />WWF OR FIBERMESH r� <br />LU <br />cn <br />z w <br />Haww <br />_ <br />w <br />=-- U <br />° ' <br />BRICK PAVERS or SLAB PER <br />Op o v <br />_.- <br />• rI <br />• • <br />_- = z Q <br />„ <br />COMMUNITY SPECS� <br />"' ¢ <br />0-0 FIN. FLR.jP <br />_ Tr` j-jj IT�TT—TT�TTY=TT' <br />4" 4" <br />INTERIOR WALL SLAB STEP NON-BRG.rK <br />SCALE:3/4"=1'-0" S3 <br />_I <br />_- - FOOTING v <br />BEYOND <br />PAD REINFORCEMENT <br />3 MIN. CLEARANCE <br />SEE SCHEDULE <br />FOOTING <br />00 G WIDTH D H <br />SEE SCHEDULE <br />PATIO COLUMN FTG. DETAIL N <br />SCALE: N.T.S. S3 <br />Ct r O <br />_ cmz <br />CVCC <br />CV <br />® <br />co c4 ._ . .e <br />' J) O O <br />[JJ <br />M <br />:tom L O, <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />E <br />a o 8 <br />C 7�ao N m <br />W C <br />M <br />Q N2s2s # W <br />i <br />V J LL LL S a <br />Z <br />O <br />o <br />WY <br />'0f6n� <br />Z 00 <br />IN M Z d J <br />= INOU <br />0. <br />W ❑❑ <br />M � <br />z N ce) <br />z � 8 <br />z o <br />J — <br />rZ. � <br />N <br />M <br />N z <br />'M <br />v � o <br />I <br />4-J N <br />� Lu <br />a <br />m <br />U <br />O —� ,, <br />N <br />U <br />a° <br />_® <br />o <br />E (J <br />I— r0 <br />z <br />ao <br />XU <br />oa <br />w0 <br />00 <br />Z <br />o E <br />o ra <br />as <br />ao <br />Q: <br />Q <br />&Z <br />ww <br />L <br />t6 <br />O <br />O0 <br />N <br />m <br />r 0 <br />O¢ <br />_- <br />Z <br />J <br />m <br />< ° <br />Q W <br />z <br />z <br />to <br />'S <br />�w <br />°oLL < <br />Z <br />a z <br />W <br />a <br />LL <br />Kg <br />NW <br />S� <br />$LL <br />w <br />=3 <br />�IM <br />_ <br />IJ <br />o <br />G.0 <br />Q <br />i; 3 <br />cO <br />� <br />LO <br />0 <br />Q <br />Cf Y <br />O <br />M <br />m <br />L�j <br />¢I <br />O N <br />O <br />TTLO <br />,— <br />L <br />r <br />E <br />rn <br />I <br />z° <br />r0 <br />z <br />_ <br />rA <br />E O m <br />Eca <br />CC <br />c <br />a <br />U Q CC <br />JOB <br />NO: 22-06459 <br />SCALE : AS NOTED <br />SHEET NO. <br />S3 <br />(MONO) <br />