My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6557 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6557 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 10:32:57 AM
Creation date
2/18/2025 3:40:24 PM
Metadata
Fields
Template:
Building Plans
Street #
6557
Location
Bar S Bar Trl
Contractor
Lennar Homes LLC
Building Plans - Permit #
5784
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I I f ___) <br />I <br />ll <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANEL CENTER <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />UNDERGROUND IQLs <br />SERVICE BY POWER CO.---_ <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER �I <br />NEC 17, 250.94 J <br />NEMA1 <br />150 AMP/ <br />200 AMP <br />#14 to lights & outlets <br />#12 to appliances and GFI <br />#10 to WH <br />#8 to Range <br />#6 to HVAC <br />200=4/0 in 2" Conduit <br />C� 1k.�TCt <br />`4 Bare Cu Ground •Y� AU <br />#4 GROUNDING WIRE <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES . Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />I. Electrical outlet heights as measured from finished floor to center line of the box to be: 1611AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />comer counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />P4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />}—�— <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />HB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />WWI_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />C� J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />VII 2h <br />AV _VTp <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />U E-Lilt-Im I CLJ RCIJCr" 1 /1lwLC <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />lN$1� <br />VERIF METER <br />LOCATION WITH <br />BUILD R WP +H.B. <br />r --t A GFI I <br />ELECTRICAL PLAN — ELEV—B1 <br />SCALE: 14"=1'-0" <br />/ 4 i <br />C\l <br />co <br />L <br />LO <br />c r- <br />i <br />0 Q d) <br />r; O O <br />3 L' U <br />CU >✓ <br />-� <br />'tea. W <br />N <br />CV <br />0 <br />M <br />LAM- <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />a <br />E <br />o ce)8 <br />Q <br />0 <br />iA N n <br />� C9 <br />LL <br />Q <br />Cn 52 <br />C J 2 LL <br />" SS a <br />_ <br />—ern o <br />W <br />�C� O o <br />cl� Of <br />W <br />Z <br />r92" <br />,04 N Z <br />r <br />N <br />OL U <br />= <br />W <br />Cn <br />❑ ❑ <br />0 <br />Z g� <br />Z o"S <br />N <br />Z <br />CZ <br />1_ , <br />LL <br />� V <br />N <br />W m <br />V <br />O <br />V) <br />W p <br />c <br />ru <br />'_19 <br />U <br />w <br />E <br />c 8 <br />I <br />• <br />Q <br />U <br />U) <br />¢coc <br />o <br />chi <br />< <br />W <br />Z <br />c"' <br />00 <br />i <br />� <br />E <br />z o <br />uj <br />Yfly <br />¢ n <br />z® <br />E U <br />i0 <br />�_ <br />x° <br />U <br />C, Q <br />S° <br />Z <br />N <br />�a <br />ao <br />°z <br />w <br />L <br />o <br />Y� <br />m <br />C <br />- � <br />.y <br />U <br />ps0 <br />oLL <br />Z <br />Z <br />Ui J <br /><m <br />Q W <br />Zo <br />g< <br />'0 <br />W <br />C1 <br />� 3 <br />Qw <br />W <br />�� <br />01 <br />NLL <br />z <br />r� <br />= <br />O <br />O <br />w.¢ <br />�O <br />aI <br />CD <br />oa <br />z¢ <br />0§ � <br />O <br />� <br />LOrn <br />cc <br />cc <br />/� <br />aU')W1 <br />j Mo <br />M <br />Y <br />Cr <br />O <br />U) m <br />N <br />m <br />LO <br />�--+ <br />¢I <br />N <br />T <br />of <br />T— <br />LC) <br />T <br />E <br />c <br />Z <br />l0 <br />Z <br />c <br />E O <br />N <br />N <br />Lo <br />c <br />a <br />U <br />Q p <br />) <br />JOB <br />NO: <br />22-06459 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.