Laserfiche WebLink
3 <br />v <br />m <br />Q� <br />Ln <br />L0 <br />c <br />c <br />0 <br />00 <br />0 <br />0 <br />0 <br />0 <br />N <br />O <br />I <br />N <br />i <br />m <br />in <br />L <br />0 <br />cn <br />0 <br />.n <br />00 <br />M <br />O <br />J <br />O <br />a0 <br />N <br />SHINGLE OR TILE ROOF PER <br />COMMUNITY SPECS - INSTALLED <br />PER MANUFACTURERS <br />SPECIFICATIONS ---, <br />12 - ��----�1 F5 <br />5� o <br />12 <br />F1 a5 <br />I <br />(+1") 6" SMOOTH I I <br />TEXTURED BAND <br />12 <br />5� <br />FIBERGLASS SHINGLE INSTALLED <br />AS PER MANUFACTUER <br />SPECIFICATIONS <br />FRONT ELEVATION - B1 <br />13'-0" RIDGE VENT <br />LEFT ELEVATION - B1 <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior Plaster. <br />Installation of these materials shall be in compliance with ASTM <br />C926 and ASTM C1063, or ASTM C1787 and the provisions of <br />this code. <br />R703.7.1 Lath. <br />Lath and Lath attachments shall be of corrosion -resistant <br />materials. Expanded metal or woven wire lath shall be attached <br />with 1-1/2" long, 11 gage nails having <br />a 7/16" head, or 1-1/2" long, 16 gage staples, spaced in <br />accordance with ASTM C1063 or C1787, or as otherwise <br />approved, (Refer to sheet SN1 for the engineered method for <br />Lath attachment.) <br />Lathing Accessories <br />Attachments shall be of corrosion -resistant materials. <br />Wood Application: 16 Ga.x1-1/2" long (3/4"-V crown) staples @ <br />6" O.C. vertically/horizontally into the framing members. <br />Masonry Application: Concrete stub nail, 3/8" (10 mm) head dia. <br />min. @ 6" O.C. vertically/horizontally or compatible adhesives, <br />exterior gun -grade, construction adhesive with V dabs @ 6" O.C. <br />or in a semi -continuous bead between the solid plaster base and <br />the solid portion of the key attachment flange. <br />Control Joints: Install control joint lathing accessories in <br />conformance with C1063. Lath shall not be continuous through <br />control joints, but shall be stopped and tied at each side. <br />All accessories shall be in accordance with the latest ASTM <br />C1063 & ASTM C1861. <br />R703.7.2 Plaster. <br />Plastering with cement plaster shall be not less than three coats <br />where applied over any type of code -approved lath and shall be <br />not less than two coats where directly applied over masonry, <br />concrete, clay brick, stone, or tile. If the plaster surface is <br />completely covered by veneer or other facing material or is <br />completely concealed, plaster application need be only two coats, <br />provided total thickness is as set in Table R702.1(1). <br />Cement plaster shall be in accordance with ASTM C926 and <br />material shall be in accordance with one of the types listed in <br />R703.7.2. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed as required in Section <br />R703.2 and, where applied over wood -based sheathing, shall <br />include a water -resistive vapor -permeable barrier with a <br />performance at least equivalent to two layers of Grade D paper. <br />The individual layers shall be installed independently such that <br />each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to <br />the water -resistive barrier is directed between the layers. <br />R703.2 Water -Resistive Barrier. <br />One layer of No. 15 asphalt felt, free from holes and breaks, <br />complying with ASTM D226 for Type 1 felt or other approved <br />water -resistive barrier shall be applied over studs or sheathing of <br />all exterior walls. No. 15 asphalt felt shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 <br />inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance <br />with the water -resistive barrier manufacturer's installation <br />instructions. The No. 15 asphalt felt or other approved <br />water -resistive barrier material shall be continuous to the top of <br />walls and terminated at penetrations and building appendages in <br />a manner to meet the requirements of the exterior wall envelope <br />as described in Section R703.1. <br />R703.4 Flashing. <br />Approved metal flashing, vinyl flashing, self -adhered membranes <br />and mechanically attached flexible flashing shall be applied <br />shingle -fashion or in accordance with the manufacturer's <br />instructions. Metal flashing shall be corrosion resistant. <br />Fluid -applied membranes used as flashing shall be applied in <br />accordance with the manufacturer's instructions. All flashing shall <br />be applied in a manner to prevent the entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. <br />Self -adhered membranes used as flashing shall comply with <br />AAMA 711. All exterior fenestration products shall be sealed at <br />the juncture with the building wall with a sealant complying with <br />AAMA 800 or ASTM C920 Class 25 Grade NS or greater for <br />proper joint expansion and contraction, ASTM C1281, AAMA 812, <br />or other approved standard as appropriate for the type of sealant. <br />Fluid -applied membranes used as flashing in exterior walls shall <br />comply with AAMA 714. The flashing shall extend to the surface <br />of the exterior wall finish. <br />Approved flashings shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry construction with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersection. <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />REV. 09.24.21 <br />00 <br />i <br />® <br />c c <br />Jj 0 <br />0 ZZ <br />0 W <br />CV <br />N <br />O <br />N <br />M <br />N <br />N <br />��'st.938d9'�Q O <br />LEyVlf,ass <br />E iN S • <br />��' 0 <br />a ` - � <br />No /50 <br />P <br />��� L <br />ate'• ST TE C' F <br />.;dB t0 <br />=N <br />�t 47tli 4ltl!" <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Cade - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />H! � <br />W v6 �oo <br />Q p N v N' J <br />LL <br />Nop <br />C1 J <br />v <br />in Lu <br />M cnr- �o �Lua <br />LL a <br />M <br />Qaj V Y <br />J LL LL0 aLu <br />Y <br />0 0 O <br />L Q W <br />� '� O 2' OJ J <br />lc <br />Z <br />ILWC/) <br />N m Z K o7 p <br />U U <br />N <br />Z O <br />U m <br />Z N O <br />0 0 <br />Z <br />N <br />z � <br />� <br />Q � <br />J <br />r <br />M <br />V) :;;I_ <br />U o <br />ELM <br />Q) <br />LLI <br />•J <br />0,,,Ci <br />U <br />F.1 <br />U <br />J <br />L <br />= L N <br />U o N <br />wi o <br />m <br />�m <br />o <br />w <br />Mz¢ <br />co <br />J <br />o <br />z <br />4 <br />� <br />l.L <br />E E <br />E � <br />w � <br />zo <br />w <br />>ry <br />¢a <br />_® <br />oa <br />— C <br />mU <br />XU <br />U <br />aF <br />wo <br />VO <br />�U <br />� <br />o � <br />0E <br />N <br />wo <br />G <br />z <br />�w <br />L <br />- (Q <br />- <br />o <br />y <br />yS <br />m O <br />Z LL <br />a�i <br />� J <br />az <br />�w <br />u) z <br />2 I <br /><. <br />< <br />2 <br />zz <br />do <br />;z <br />LL <br />ww <br />ci 3 <br /><o <br />�K <br />xo <br />�o <br />a <br />wa <br />VO' <br />za <br />O O <br />> <br />LOrn <br />.-� <br />Qom^,, <br />i <br />00 <br />J <br />O <br />C <br />O <br />O <br />Y <br />Y <br />W <br />m <br />¢ <br />O 04 <br />I <br />N <br />O <br />co <br />Li') <br />< <br />r <br />N <br />T <br />E <br />'E 00 <br />W <br />O <br />Z <br />03 <br />Z <br />ii <br />E O c <br />c <br />a <br />U � Q p <br />_J <br />JOB <br />NO: 22-02400 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.1 <br />