My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6597 Bar S Bar Trl
Zephyrhills
>
Building Department
>
Building Plans
>
6597 Bar S Bar Trl
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 11:15:55 AM
Creation date
2/18/2025 3:41:44 PM
Metadata
Fields
Template:
Building Plans
Street #
6597
Location
Bar S Bar Trl
Contractor
Lennar Home LLC
Building Plans - Permit #
4632
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />v <br />00 <br />roi <br />to <br />LO <br />a� <br />NC <br />C <br />0 <br />0 <br />PM <br />O <br />0 <br />J <br />N <br />0 <br />I <br />00 <br />O <br />rn <br />LO <br />v <br /><n <br />0 <br />0 <br />C) <br />J <br />to <br />N <br />O <br />I <br />A <br />LO <br />LO <br />0 <br />0 <br />0� <br />Y <br />a <br />N <br />O <br />a <br />E <br />t"2 <br />CD <br />E <br />12 <br />G <br />J <br />a> <br />O <br />v <br />0 <br />U <br />rn <br />U <br />0 <br />U <br />7 <br />z <br />N <br />Y <br />i <br />0 <br />•U <br />J <br />tZ <br />N <br />M <br />N <br />Gi <br />0 <br />0 <br />0 <br />a <br />CV <br />CV <br />0 <br />N <br />CV <br />A. <br />s <br />m <br />cn <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150A/200A INDOOR <br />PANELCENTER <br />NEMAI <br />150 AMP/ <br />200 AMP <br />MAIN <br />O <br />200 amp <br />150 amp <br />copper to lights & outlets <br />copper to 20 amp ckts <br />.2 copper to WH <br />.3 copper to Dryer <br />or 4/0 SER Alu <br />UNDERGROUNDjDisconLnectPOWER <br />CO. FEED <br />Cu Ground <br />INTERSYSTEMre <br />BONDINGNDING <br />WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF NEC 17, <br />GENERAL ELECTRICAL NOTES . <br />Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine, Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4 , <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />lO <br />EXHAUST FAN <br />Q <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH I <br />CHIMES (OPTIONAL) <br />HE9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />�M <br />ELECTRIC METER <br />WWI <br />ELECTRIC PANEL <br />I <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />�711� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />SECOND FLOOR ELECTRICAL PLAN — ELEV—Al <br />SCALE: )/4"=1'-0" <br />Cl) <br />.. <br />LO :1 <br />Q •.a <br />U <br />r• - <br />c2 <br />OO <br />- t' <br />d o w <br />C14 <br />CV <br />CD <br />CV <br />�o <br />4-. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural <br />plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential <br />7th Edition. Engineer's signature and seal is only for <br />the structural <br />engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W 00 <br />v E <br />Q <br />o" N m <br />N LL <br />V Off' C:c0 J <br />G 0? uat w <br />-o <br />Cn r r J lL a- <br />N M C) LL a <br />Y <br />u u- 0- Lu 3:_ <br />03 C o <br />ILa <br />da a <br />Z co <br />ILW��pjO' <br />N 91 Z (n Q <br />p U v—j U) <br />Z <br />W 17",❑ <br />z N M <br />O O <br />Z N <br />z � � <br />Q <br />J <br />d � <br />r` <br />M <br />V) Z Mo <br />(D <br />() o <br />W <br />� <br />U <br />OL.Uwss <br />o <br />�V) <br /><n <br />U <br />L <br />c U) d <br />®® <br />0 <br />�m <br />C7 <br />M <br />¢ <br />w <br />Z <br />M <br />w <br />zo <br />Q <br />J <br />LL. <br />cif E <br />m c <br />zo <br />>o <br />4N <br />Q <br />E ° <br />0 F <br />w'z <br />Z <br />to <br />♦— � <br />020 <br />XU <br />o0 <br />�:)U <br />o <br />N <br />d¢ <br />o <br />¢o <br />O< <br />wW <br />eJ <br />>_ <br />ra <br />U <br />� <br />mo <br />oZ <br />Z <br />ZY <br />C <br />J <br />N !D <br />a� <br />Q W <br />�z <br />ZO <br />2 <br />2U <br />Q <br />0i <br />w <br />a <br />nw <br />W <br />� <br />Qo <br />Qz <br />J <br />C:'o <br />aF <br />� <br />co <br />coV <br />zl¢ <br />r <br />03 <br />> u! <br />u! <br />N <br />t71 <br />((a <br />0 <br />L <br />LO <br />O <br />co <br />Y <br />U <br />O� <br />r ^ <br />/� <br />W <br />m <br />1 <br />}� <br /><C <br />0 <br />0')L0I <br />CVC'J <br />� <br />00 <br />LO <br />O <br />M <br />N <br />Q <br />cor <br />U <br />m <br />N <br />� ri N <br />o <br />Z <br />Z <br />E <br />c <br />c <br />a. <br />U 0 Q p <br />d) <br />JOB <br />NO : 22-02397 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.