LINTELS FOR WALLS 0 `O � � <br />NO <br />DOWEL AT LOCATIONS O <br />WHERE OPENING SHOULD HAVE A 'Pik NOTES: O <br />CONFLICTS W/ TYP. CAPACITY OF 1500 r^ _ - _ _ __ _ .._ ___.. __ _ N U a) ^ t I <br />WALL REINF. PLF, U.N.O. ? 1. VERTICAL WALL REINFORCING SHALL ALIGN WITH Z W 0" LO 0" <br />MAX. SPACING 25'-0" VERTICAL FOUNDATION DOWELS. DOWELS SHALL w J o • ap 00 cy <br />LINTELS FOR WALLS BE PLACED AS SHOWN ON DETAILS WITH }} ¢W W j �}� 0 I� g <br />SHOULD HAVE A r NOTE NOTE' STANDARD ACI HOOK DIRECTLY ON TOP OF J > O <br />CAPACITY OF 1500 #7 BOTTOM LAYER OF FOOTING REINFORCING. REFER m W Ir O _, NOTE #5 TYP O W o a) x <br />PLF, U.N.O. <br />SCHEDULE <br />ON PLAN ,} <br />,;: <br />-r i . - <br />W - <br />U(nW�j 0 c 0 <br />PROVIDELINTEL / i-. L _- O W <br />CM WALL REIN <br />SLOT AT END TO _. ___ ;, r_., __r- _. :_ I_. _" PLACED AS SHOWN ON DETAILS GROUT CELLS O m <br />F <br />0 48" 8" " " ALLOW FOR VERT. ; - - I € € FULL THAT CONTAIN REINFORCEMENT. T z W ~ O O <br />TYPICAL VERTICAL WALL REINFOR 0 BE <br />MIN. MIN. 8 8 BAR REINF. TO PASS " z <br />MIN. MIN. 6 HOOK AT 3. REFER CMU LINTEL SCHEDULE FOR SIZE, <br />w PRECAST LINTEL BY THRU CONTINUOUS. - -_.1_ ___ _ _ �__ ! . _ i.._. _ _ NOTE #4 TYP. - -0" O.C. LOCATION AND QUANTITY OF LINTEL (n 0 N c <br />8' <br />cn PRECAST MANUF. i._. _... _ _ MAX. _0 <br />d REINFORCEMENT. o 0 w <br />IF OPENING IS ABOVE b - - - 4. VERTICAL REINFORCING BARS MAY BE SPLICED H N - CL <br />CEILING USE LINTEL & PRECAST LINTEL BY I , i _r _ -0" TO 8'-0" LE N V z_ (n z_ o <br />IF OPENING IS BELOW a I I PRECAST MANUF. a r _ �.__ ._ - ! Q w � <br />i T .,._ _, 5 R F- V <br />IN 6' NGTHS <br />CEILING USE U-BLOCK w co <br />�i r q , L I <br />._ __..._i._--. __ �,_ _ . _ ; TRUSS HORIZONTAL <br />AT 16" REINFORCING <br />ABOVEGRADEAND 8" U z W N <br />AS SHOWN IN DETAIL I L z z J c M <br />4-005 2 € _ NOTE #8 TYP. 1 r.. NOTES 1, #2 O.C. BELOW GRADE UNLESS OTHERWISE NOTED O O W O Q O � 0 <br />�.-. - U (n <br />z ADD L VERTICAL _I z_I _ . TYPICA CONTROL JOINTS. W O W O <br />c� o ON PLANS AND DETAILS. DISCONTINUE AT Z 0 <br />z BAR ON EACH c� r € _.Y._ . NOTE #9 TYP. _ . _, .. U z <br />o I I SIDE OF OPENING I x- 6. O <br />r . _ . , € CONTRACTOR SHALL USE THE LOW LIFT METHOD O a) <br />--`. _ ... -___�_ ..�_ _..7. j Y._... _. _ O t <br />-- _ -I I Q M OF GROUTED MASONRY CONSTRUCTION UNLESS Q v a �- <br />_.._ T _. PROVIDED AT EACH VERTICAL - - <br />PROVIDE LINTEL w CLEAN OUTS R N V O <br />REINFORCING BAR. P Y O I� <br />FIN. FLOOR <br />G _.._ } ._ t__• € a W o z H tr s N 0 <br />AT OPENINGS THAT SEE PLAN 2'-0" 2'-0" �y { W o 7. REFER TO PLANS AND DETAILS FOR SIZE AND F W 3 to v } _0 <br />g to I LOCATION OF BOND BEAMS AND QUANTITY OF Q O L L EXCEED 16" WIDE II II 9<< r " a O H O <br />-. REINFORCING. LAP REINFORCING 24 MINIMUM. <br />NOTE: DISCONTINUE BOND BEAMS AT CONTROL JOINTS. p z W Z uj <br />8. REFER LINTEL SCHEDULE NOTES FOR VERTICAL I.,_ W Z <br />II II USE HILTI KWIK-CON II 3/16 SCREWS INTO CMU WITH " BARS ADJACENT TO OPENING. Z x Z z Q <br />4- NO. 75 TRIANGLE WIRE TIE. PROVIDE CONTINUOUS 3/16 - Z - J <br />HOT DIP GALVANIZED WIRE AT MORTAR JOINTS AND ATTACH CONTROL JOINT (2)-#5 BARS TYP. 9. PROVIDE VERTICAL WALL REINFORCING IN FIRST Z Z p p d <br />• 'a : n �. . •:,.. ABOVE &BELOW W W g <br />TO TRIANGLE TIE WITH WELDED NO. 370 SEISMIC CLIP. SEE NOTE #10 CELL NEXT TO CONTROL W J �,� = z V <br />OPENING JOINTS/CORNERS/OPENINGS. TYPICAL. x Z O G Z o <br />OPENING (SEE ARCH.) 10. VERTICAL CONTROL JOINTS SHALL TERMINATE AT W Q x � o (�j o <br />FINISH MASONRY TOP OF FOOTING. a Z Z o <br />11. PROVIDE CORNER BARS TO MATCH TYPE AND w ~ w W z � o N N <br />CONNECTION TO CMU /STUD WALL QUANITY OF HORIZONTAL WALL REINFORCING, 0- xO W N w -j uJ ^ o <br />TYPICAL LINTEL TYPICAL LINTEL SCALE: 3/8" _ -0" TYPICAL. U U= w W W � z z v, c N E z <br />CMU WALL REINFORCING LAYOUT 0 W <� z a o z a: 00 <br />a- <br />OVER DUCT OPENING 4-004 OVER OPENING 4-005 4-006 4-009 ow0 w w <br />SCALE: 3/8" = 1'-0" SCALE: 3/8" 1'-O" SCALE: 3/16" 1'-O" _ = o 0 <br />O ~ F �Wm <br />W O�UO O o` wa^ E <br />LOOSE ,LINTEL SCHEDULE Z m L o 0 M a N <br />CMU LINTEL SCHEDULE k `a' Qo<U_ �¢� W <br />LAP SPLICE SCHEDULE FOR J SEE SCHEDULE z Z p Z U O z <br />SINGLE REINFORCED 8" CMU OPENING SIZE LINTEL WALL UNTEL BOTTOM TOP STIRRUPS NOTES J z FOR REINF. TYP. o <br />UP TO 4'-0" L3 1/2" X 3 1/2" X 1/4" THICKNESS DEPTH REINFORCING REINFORCING & SPACING a <br />BAR SIZE LAP SPLICE REMARKS z z CONCRETE <br />" J FILLED TYP. G p copyright <br />" " " " PCL-1 8 1-#5 N/A N/A a 0 <br />#3 1 g OVER 4 -0 - 5'-0" L4 X 3 1 /2 X 1 /4 z n z n- N kx< <br />#4 25 OVER 5'-0" - 6'-0- L4" X 3 1/2" X 5/16" MASONRY 8" MASONRY PCL-2 16" 1-#5 1-#5 #3016 Z '- ' -� <br /><' ,h. <br />#5 31 OVER 6'-0" - 7'-0" L5" X 3 1 /2" X 5/16" " � <br />#6 57 PCL-3 24 1-#5 1-#5 #3024 WALL WALL WALL <br />OVER 7'-0" - 8'-0" L6" X 3 1/2" X 5/16" " WIDTH WIDTH WIDTH U <br />#7 79 PCL-4 32 1-#5 1-#5 #3024 �_ PCL 2 P�� <br />OVER 8'-0" NOTE 6 <br />#8 112 VERTICAL REINF. PCL-5 40" 1-#5 1-#5 #3024 <br />#9 146 NOTE 8 SEE PLAN z <br />PCL-6 48" 1-#5 1-#5 #3024 <br />Z. <br />I I CT <br />VERTICAL REINF. <br />Z <br />NOTES (UNLESS NOTED) <br />1'-2" CAVITY WALL 4-�5 SEE PLAN NOTES: <br />1. PRECAST CONCRETE UNTELS CAN BE INSTALLED AT ALL OPENINGS PER <br />NOTES: 1. PROVIDE ONE ANGLE FOR EACH 4" OF MASONRY WIDTH. SCHEDULE. CAST IN PLACE CONCRETE UNTELS SHALL BE PLACED WHERE <br />2. FOR 6" MASONRY WIDTH USE L5"X 5"X 5/16" UP TO 5'-0" OPENING SHOWN ON PLANS. SUBSTITUTED UPON APPROVAL BY ENGINEER. m <br />1. LENGTH OF SPLICES ARE BASED ON FLORIDA BUILDING SIZE AND L5" X 5" X 3/8" UP TO 8'-0" OPENING SIZE. 2. GROUTED LINTEL (THROUGH) BLOCKS SHALL EXTEND A MINIMUM OF 8" • ` �;` J 1- 5 EACH <br />PRECAST LINTEL a # <br />CODE 2004. 3. BEAR LINTELS 6" MINIMUM EACH END OF OPENING. BEYOND FACE OF OPENING EACH SIDE UNLESS NOTED OTHERWISE. THE z BOND BEAM <br />TT. TEL _ W/ 1-#5 CONT. <br />2. LAP SPLICES INDICATED ARE IN INCHES. 4. ALL DOUBLE ANGLE LINTELS BACK 0 BACK SHALL BE BOLTED AT SEE ARCH. FIRST TWO VERTICAL CELLS EACH OF THE OPENING SHALL BE GROUTED Ja o COURSE TYP. <br />3. THIS SCHEDULE IS FOR 8" CONCRETE MASONRY UNITS 2'-6" O.C. MAXIMUM. MINIMUM OF 0 BOLTS PER LINTEL. AND CONTAIN 2-#5 VERTICAL EACH FACE. z z <br />(CMU) ONLY. 5. STRUCTURAL STEEL CONTRACTOR S ALL SUBMIT A COMPLETE a <br />4. SEE DETAIL FOR LAP SPLICE SCHEDULE FOR DOUBLE SCHEDULE OF LOOSE LINTELS WITH THE ERECTION PLANS SHOWING NOTE: THE FIRST CELL EACH SIDE OF THE OPENING SHALL BE z SEE SCHEDULE <br />REINFORCED 8" CMU. MARK, MASONRY OPENING, ANGLE SIZE, LENGTH AND DIMENSIONED GROUTED TO LINTEL LEVEL. SECOND CELL SHALL BE GROUTED TO ROOF o g FOR REINF. TYP. <br />SECTION. WHERE LINTEL MARKS AR USED ON PLAN, USE THE SAME LEVEL. z <br />MARK WITH SUBMARK A,B,C,D, ETC. FOR DIFFERENT LENGTH. N CONCRETE o • <br />6. W SECTION WITH 1/4" CONTINUOUS PLATE (W DEPTH = 1/12 OF SPAN; 3. SEE SPECIFIC DETAIL FOR BRICK LEDGE SUPPORT ANGLE OF LOOSE LINTEL FILLED TYP. E <br />CONTINUOUS PLATE WIDTH MASONRY LESS in) BEARING EACH END SCHEDULE. <br />LAP SPLICE SCHEDULE TO BE 8" MINIMUM. 4. CONSTRUCTION/CONTROL JOINT SHALL NOT BE LOCATED WITHIN WIDTH OF tt 0 <br />• " OPENING, NOR SHALL IT BE LOCATED WITHIN 24" OF THE OPENING ON ! w <br />7. WHERE EDGE OF OPENING IS LESS AN 1 -0 FROM COLUMN FACE, ri <br />» EITHER SIDE. �:,� <br />SINGLE REINFORCED 8 CMU EXTEND LINTEL AND CONNECT TO COLUMN. " TYP. PRECAST LINTEL SECTION ° 5. CONCRETE LINTEL BEARING EACH SIDE OF LINTEL TO BE EQUAL TO DEPTH <br />8. AT CAVITY WALLS EXTERIOR ANGLE R HAVE 5 HORIZONTAL LEG. - 1 O OF LINTEL, TYPICAL UNLESS NOTED OTHERWISE. WALL WALL WALL 0 _ <br />9. FOR ALL OPENINGS IN WALLS, SEE ARCHITECTURAL AND MECHANICAL SCALE: 3/4" - WIDTH WIDTH WIDTH g <br />DRAWINGS. <br />PCL-4 PCL-5 PCL-6 <br />14-02,3114-03-11TYPICAL PRECAST&I.P. LINTEL DETAIL 14-033 <br />SCALE. 3/4 = 1 -0 a N <br />Nt <br />X X X X M <br />FILL W/ CONC. EXTERIOR METAL STUD WALL DESIGN. NOTES: <br />• N0� 1 SIZE AND SPACING OF COLUMN TIES o v <br />SAME CAPACITY <br />CONCRETE COLUMN AS SLAB 1. CALCULATE PROPERTIES AN LOAD CAPACITIES OF a e : e ie A e 8" 1o" 12" 14" 16" 18" 20" 22" 2�4j`pOR p <br />SEE PLAN AND I : E IYIVRL <br />SCHEDULE �.� JOINT FILLER TO MEMBERS PER THE AISI SPECIFICATIONS FOR DESIGN OF �- NOTE 1 -0 `~ <br />EXTEND FULL COLD -FORMED STEEL STRU TURAL MEMBERS. #5 #308 #3010 #3010 #3010 #3010 #3010 #3010 #3010 #3010 ° - _N <br />b DEPTH OF JOINT 4 BARS 6 BARS 8 BARS � 0 - <br />2. DESIGN EXTERIOR CURTAIN ALL TO SUSTAIN WIND 0) s <br />LOADS INDICATED IN THE S HEDULE OF LOADS NOTE 1 #� #308 #3010 #3012 #3012 #3012 #3012 #3012 #3012 #3012 0 s <br />a• NOTE 1 <br />DRAWING. #7 #308 #3010 #3012 #3014 #3014 #3014 #3014 #3014 #3014 2 �O <br />} .. 3. LIMIT LATERAL DEFLECTIONS UNDER DESIGN LOADS TO e _ . I: ° `O N <br />r. L/800 OR 3/8" WHICH EVE IS SMALLER FOR THOSE " a ` #e #308 #3010 #3012 #3014 #3016 #3016 #3016 #3016 #3016 <br />AREAS WITH BRICK CLADDIN AND L/360 FOR ALL x 4' <br />j NOTE: ' P #9,#10 #308 #3010 #3012 #3014 #3016 #3018 #3018 #3018 #3018a <br />FTG, COL, & SLAB OTHER AREAS. <br />. � � ., 1 BARS � revisions: <br />REINFORCEMENT NOT 4. PROVIDE SLIDE CLIPS OR DEFLECTION TRACKS ON THE 12 BARS ARS #11 #14 #408 #4010 #4012 #4014 #4016 #4018 #4020 #4022 #4022 0 <br />SHOWN FOR CLARITY UNDERSIDE OF THE ELEVA D LEVELS TO ALLOW FOR A ' X X & #18 Q <br />1- 3 TOP - MAXIMUM LIVE LOAD VERTIC L DEFLECTION OF X X A = SIZE OF VERTICAL REINFORCING <br />(4 SIDES) APPROXIMATELY L/360 AT ID SPAN BETWEEN x ` a : B = LEAST DIMENSION OF COLUMN <br />r - - - - - COLUMNS. x y :. :. , I., ..- . <br />PREMOLDED JT. y PREMOLDED JOINT 5. DIAGONAL KICKERS ARE NO ALLOWED, UNLESS I ., ..... I- o Q <br />FILLER & SEALANT FILLER & SEALANT •' •'''• <br />I APPROVED IN WRITING BY ARCHITECT AND ENGINEER OF .e..._... a NOTES: <br />RECORD. NOTE 1 <br />1. THESE BARS MUST BE TIED AS SHOWN BY DASHED LINES � 9/18/2008 <br />t 6. DESIGN ALL CONNECTIONS SUSTAIN THE MAXIMUM 16 BARS WALL TYPE COLUMN WHEN "X" DISTANCE IS OVER 6 INCHES AND NEED NOT BE <br />I I DESIGN LOADS. TIED WHEN "X" IS 6" OR LESS. steel roof/wood roof <br />PIER OR FTG.-� 7. ALL DETAILS DRAWINGS SH WN ARE MINIMUMS 2'-1" STAGGER MIN. 3 SPACERS 2• MINIMUM CLEAR COVER 1 1/2" TO TIES (2" FOR EXPOSED o <br />`j- NO KEY 0 COL. - PER SPIRAL CONDITION). <br />BELOW I REQUIRED FOR PARTICULAR CONDITIONS. CONTRACTOR FOR #4 <br />L - - - - - - J POCKET (TYP.) a o 3. FOR VERTICAL COLUMN REINFORCING, SEE PLAN AND COLUMN <br />IS RESPONSIBLE TO SUBMIT SIGN AND SEALED -: - 1 -6 STAGGER ,. SCHEDULE. <br />KEYED CONSTR. DRAWINGS AND CALCULA-00 S FOR A WALL SYSTEM a • FOR 4. FOR SPIRAL SEE COLUMN SCHEDULE. drawn: sc/dm <br />JOINT (TYPICAL) - " NOTE 4 <br />THAT COMPLIES WITH THES NOTES, THE � <br />SPECIFICATIONS AND THE C NTRACT DOCUMENTS 4 BARS 5 OR MORE checked: rd <br />BARS ROUND COLUMN <br />TYPICAL CONCRETE COLUMN INCLUDING BUT NO LIMITED TO STRUCTURAL AND TIES IN ROUND COLUMN W/ SPIRALS date: 1 -15-08 <br />ISOLATION JOINT DETAIL ARCHITECTURAL DRAWINGS. o <br />� proj. no: P07-15B <br />SCALE: 1/2" = V-0" 13-0141 TYPICAL COLUMN SECTIONS & TIE SCHEDULE 3-061 <br />ARMANDO A. CASTELLON, P.E. <br />FL LI C. No. 43453 rc S3eO2 <br />Signature ate <br />TIC -11I i-T I I If t j -- - - - - - - - - 7- 111 1 i , rf_ ;, ,1, n ni i I - i I - -- I - - 1 - - 1 11 - , <br />