My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6636 Back Forty Lp
Zephyrhills
>
Building Department
>
Building Plans
>
6636 Back Forty Lp
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 11:47:53 AM
Creation date
2/18/2025 3:43:40 PM
Metadata
Fields
Template:
Building Plans
Street #
6636
Location
Back Forty Lp
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELEC <br />METER <br />L— — — — —— <br />—J <br />FIRST FLOOR ELECTRICAL PLAN (ELEVATION A <br />1 /411 = 1'-011 <br />ELECTRICAL NOTES: <br />1. GFCI'S ARE TO BE INSTALLED IN THE FOLLOWING <br />LOCATIONS AS SPECIFIED PER NFPA 70 (NEC) 2017 <br />A) BATHROOMS <br />B) GARAGES, AND ALSO ACCESSORY BUILDINGS THAT <br />HAVE A FLOOR LOCATED AT OR BELOW GRADE LEVEL <br />NOT INTENDED AS HABITABLE ROOMS AND LIMITED TO <br />STORAGE AREAS, WORK AREAS, AND AREAS OF <br />SIMILAR USE. <br />C) CRAWL SPACES AT OR BELOW GRADE. <br />D) KITCHENS - WHERE THE RECEPTACLES ARE <br />INSTALLED TO SERVE THE COUNTERTOP SURFACES. <br />E) LAUNDRY, UTILITY, AND WET BAR SINKS - WHERE <br />THE RECEPTACLES ARE INSTALLED WITHIN 6 FEET OF <br />THE OUTSIDE EDGE OF THE SINK. <br />2. ARCH FAULT OUTLETS ARE REQUIRED PER NFPA 70 <br />(NEC) 2017, INCLUDING ARTICLES 210 AND 400. <br />3. ANY CONFLICTS BETWEEN LOCATION OF <br />MECHANICAL FIXTURES ON PLANS AND THE ABILITY TO <br />LOCATE THEM IN THE FIELD MUST BE REPORTED TO THE <br />ARCHITECT PRIOR TO INSTALLATION. <br />4. RECEPTACLE OUTLETS IN GARAGE MUST BE <br />SERVED BY SEPARATE BRANCH CIRCUIT THAT DOES NOT <br />SUPPLY OTHER OUTLETS. <br />5. CM MUST BE AT LEAST T FROM BATH DOOR AND AT <br />LEAST 6' FROM KITCHEN RANGE/OVEN. <br />NOTES: <br />UNLESS OTHERWISE NOTED <br />1. ELECTRICAL OUTLET HEIGHTS AS MEASURED FROM FINISHED <br />FLOOR TO CENTERED LINE OF THE BOX TO BE: 12" AFF <br />(GENERAL) <br />KITCHEN <br />44" AFF <br />BATHROOM <br />39" AFF <br />LAUNDRY ROOM <br />36" AFF <br />EXTERIOR WATERPROOF <br />12" AFF <br />GARAGE GENERAL PURPOSE <br />42" AFF <br />RANGE <br />2" AFF <br />2. ALL TRIM PLATES & DEVICES TO BE GANGED, WHERE <br />POSSIBLE. <br />3. ELECTRICAL SWITCHES TO BE AT 42" CENTERLINE ABOVE <br />FINISHED FLOOR <br />4. ELECTRICAL PLAN IS INTENDED FOR BID PURPOSES ONLY. <br />ALL WORK SHALL. BE DONE IN STRICT ACCORDANCE WITH THE <br />NATIONAL ELECTRIC CODE, LATEST EDITION, BY A LICENSED <br />ELECTRICAL CONTRACTOR WHO SHALL BE RESPONSIBLE FOR <br />THE INSTALLATION & SIZING OF ALL ELECTRICAL, WIRING & <br />ACCESSORIES. <br />5. SMOKE DETECTORS SHALL BE INSTALLED AS DIRECTED BY <br />THE 2016 NFPA 72 NATIONAL FIRE ALARM CODE. <br />6. ALL ELECTRICAL IN THE LIVING ROOMS, DINING ROOMS, <br />SUNROOMS, FAMILY ROOMS, DFNS, LIBRARIES, SLEEPING ROOMS, <br />PARLORS AND SIMILAR ROOMS OR AREAS SHALL BE ON AN A.F.C.I. <br />PROTECT CIRCUIT PER NFPA 70 (NEC) 2017. <br />7. IN ALL AREA SPECIFIED IN NFPA 70 (NEC) 2017 210.52, ALL 125 <br />VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED <br />TAMPER -RESISTANT RECEPTACLES. <br />200A INDOOR PANEL <br />CENTER <br />#15 copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />METER <br />2/0 or 4/0 SER Alu <br />MAIN <br />0 <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />4 Bare Cu Ground <br />Footer STEEL <br />Groundrod tied to footer steel <br />OR <br />4 Bare attached to footer steel <br />GROUNDING PER 250.50 AND <br />250.52 NEC <br />TYPICAL 150-200 AMP ELECTRICAL <br />RISER DIAGRAM <br />NTS <br />ELECTRICAL DETAIL: <br />INTERCOM <br />SPEAKER <br />ALIGNED W/ <br />EDGE OF <br />SWITCH <br />io <br />SWITCH <br />° <br />4 1/2" <br />DOORJAMB <br />DUPLEX <br />OUTLET ih <br />TRIM <br />o <br />0 <br />BASE <br />NOTE: <br />ALL DIMENSIONS ARE FROM ROUGH FRAMING <br />SMOKE DETECTOR LOCATION: <br />WALL <br />aZ <br />C �' <br />SMOKE DETECTOR <br />MIN. <br />ELECTRICAL LEGEND: <br />NOTE: ALL HEIGHTS ABOVE FINISH FLOOR <br />110V DUPLEX OUTLET AT 12" <br />110V DUPLEX OUTLET AT 39" NOTE: ALL <br />RECEPTACLES <br />110V DUPLEX OUTLET AT 43" ABOVE <br />COUNTERS <br />110V DUPLEX OUTLET AT 45" SHALL BE <br />SPLIT 110V DUPLEX OUTLET MOUNTED <br />AT 12" - TOP PLUG IS HOT HORIZONTAL <br />110V QUAD OUTLET AT 12" <br />WEATHERPROOF GFCI OUTLET AT 12" <br />220V OUTLET AT 30" <br />110V DUPLEX FLOOR OUTLET <br />OUTLET - VERIFY W/MANUF. SPECS <br />FOR LOCATION & TYPE <br />TELEPHONE OUTLET AT 12" OR AS NOTED <br />TELEVISION OUTLET AT 12" - WIRE FOR <br />CABLE & SATELLITE <br />© STRUCTURED WIRE OUTLET <br />�— SWITCH AT 36" <br />� 3 WAY SWITCH AT 36" <br />-W— 4 WAY SWITCH AT 36" <br />-0 PUSH BUTTON FOR GARAGE DOOR OPENER <br />—o DIMMER SWITCH AT 36" <br />PUSH-BUTTON DOORBELL <br />-}- CLG MNT LT FIXTURE <br />{!}- CLG MNT PREWIRE - FIXTURE BY OWNER <br />{}- SURFACE MNT FIXTURE <br />{�} WALL MNT FIXTURE <br />NOTE: <br />40W A 6" ROUND OPALEX - ALTERNATE <br />TUB/SHOWER CANS MAY BE <br />0 50W PAR30 NFL 6" WHITE BAFFLE USED IF <br />APPROVED BY <br />0 50W MR16 4" LOW VOLTAGE OWNER <br />�l 50W PAR20 NFL 4" MINI ROUND RECESS Pla <br />�oZ 50W PAR20 NFL 6" RD REGRESSED BAFFLE EYEBX <br />_} CLG FAN PREWIRE AND SWITCH <br />Cos COMBINATION CARBON MONOIXED DETECTOR/ <br />SMOKE DETECTOR <br />C SMOKE DETECTOR <br />cU-18a UNDER CABINET 18" <br />cS-18= SINGLE 18" FLUOR STRIP <br />=U-24= UNDER CABINET 24" <br />=S-24= SINGLE 24" FLUOR STRIP <br />=D-24= DOUBLE 24" FLUOR STRIP <br />U-36 = UNDER CABINET 36" <br />S-36 — SINGLE 36" FLUOR STRIP <br />D-36 — DOUBLE 36" FLUOR STRIP <br />c S-48 — SINGLE 48" FLUOR STRIP <br />D-48 DOUBLE 48" FLUOR STRIP <br />24 24"CLG MNT WRAPPED FLUOR LIGHT <br />® 48"CLG MNT WRAPPED FLUOR LIGHT <br />F7F 24 :;R 24" VANITY LIGHTING <br />q;;7 36 36" VANITY LIGHTING <br />48 48" VANITY LIGHTING <br />EXHAUST FAN/LIGHT <br />C� EXHAUST FAN <br />d,p DOUBLE FLOOD LIGHT W/ COVERS AND <br />Li 150W PAR 38 FL <br />® INTERCOM SPEAKER AT 5'-0" ABV FINISH FLOOR <br />CEILING MNT SPEAKER <br />CM CHIMES (DELETE W/ INTERCOM) <br />IMEr MASTER STATION <br />1N&3 ELEC PANEL <br />VACUM OUTLET AT 12" <br />CEILING RETURN AIR <br />B A/C REGISTER <br />(TJ THERMOSTAT <br />02 SECURITY PAD <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR LOCATION PURPOSES. <br />(� N LO E <br />OP o <br />M 0 y <br />H M ao <br />E CO <br />2$ <br />0 U— o � <br />Ups <br />i <br />�N f' IJ'A QN C <br />W L 0O E .m <br />CO <br />LU <br />ILL! C7 LV <br />Q � <br />� , w �j W � O <br />� � o: z o: <br />o:Oj2�¢OoD:¢LL c��00��0 <br />(� O <br />_ <br />O <br />a(On0�OZOR6gM0z�z0 <br />�LLJ ollu:W <br />Q <br />LL <br />Z <br />0�a w�_wz� <br />8w~� �wZ¢ <br />O 0 <br />v nd <br />O w¢ o ¢w <br />1 <br />O <br />Z 04 <br />O F_ <br />U) ::) r.. <br />�F=MO <br /><u)M� <br />�U)LLti <br />LU LO <br />F-WaM <br />CL <br />00 <br />ZUf< <br />Z <br />W <br />WO <br />J <br />0 <br />Mj <br />Virtual Review q <br />Review complete <br />ist. <br />l c. <br />ante with the 20 <br />and <br />F0 <br />aPP <br />ove <br />Debra Anne Klah <br />pX <br />0 3t <br />E�' <br />iQ <br />LO <br />O <br />O <br />N <br />O <br />N <br />O <br />N <br />O <br />N <br />N <br />O <br />f`V <br />M <br />O <br />N <br />o <br />°°o <br />o <br />N <br />a <br />a <br />s <br />N <br />Z <br />�� <br />O <br />N� <br />W <br />o <br />0 <br />0 <br />0 <br />0 <br />0 <br />l <br />� <br />N <br />M� <br />VJ <br />}~ <br />zZ <br />W <br />Q w <br />C)W <br />Woo <br />cy) <br />� <br />U <br />� <br />LO <br />F_ <br />O <br />z> <br />w— <br />o 0 <br />ra <br />Z <br />r� <br />� <br />F- <br />w a <br />1� <br />N <br />mftw <br />�_2 <br />N <br />W <br />ZOM <br />W <br />CV <br />Z <br />() <br />Ix <br />w w <br />az <br />Z <br />�z <br />0U <br />a- <br />.0 <br />W <br />Z <br />Z <br />Z <br />w <br />J <br />W <br />'^ <br />O <br />LAST PLOT DATE <br />o <br />Z <br />■ <br />O <br />May 8, 2023 <br />1 ST FLOOR <br />ELECTRICAL PLAN A <br />
The URL can be used to link to this page
Your browser does not support the video tag.