Laserfiche WebLink
L0 <br />E <br />S <br />C71 <br />V) <br />LO <br />C14 <br />T <br />E <br />S <br />9 <br />3 <br />(S <br />THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METALLATH <br />16GAxl-1\2" LONG (3/4%1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAxl-1/2" LONG (3/4"-l" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />"ONLY APPLIES TO LENNAR TPA/JAX** <br />101-011 <br />TANK -LESS W/H <br />CORNER OF__/ I % r <br />HOME H C G <br />GARAGE SIDE 000 <br />51-011 <br />1-019 <br />STUB -OUT FOR L 9 _1 U <br />GAS METER 0 <br />0 <br />0 <br />MEASUREMENTS ARE FROM FINISHED FLOOR <br />ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL. <br />"ONLY APPLIES TO.HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2) 16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2) 16d TOENAILS <br />2" X 8- @ 16" O.C. <br />13-4- <br />(3) 16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />191-310 <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4- @ 24" O.C. <br />6-41 <br />(2) 16d TOENAILS <br />2- X 6" @ 24- O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />111-001 <br />(2) 16d TOENAILS <br />2" X 10" @ 24" O.C. <br />131-011 <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />SOUTHERN YELLOW PINE, 55 PSF LOADING <br />FILL CELL—\ STD. 900 HOOK BOND BEAM <br />'M <br />F <br />SIMPSON MGT <br />w/ (22) 1 Od <br />GIRDER TRUSS <br />NAILS TYP. <br />CONT. #5 <br />STD. 900 4�r 1 <br />CONT. #5 HOOK --------- BAR 2X TOP PLATE <br />BAR i F'� " F <br />11 - 11 1-h 1 11 11 #5 CONT. <br />FROM <br />FOUNDATION <br />F-7] TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />—PLAN FOR MORE INFO <br />—CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D ���PLYWOOD FLOOR <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />�J, <br />FOR BLOCKINGrTJI <br />::MASONRY WALL OR <br />INTERIOR BRG. WALL <br />< TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from STUDS <br />above to bearing below. <br />DOUBLE JOIST CONSTRUCTION SECTION @ INT. BRG. WALL <br />Backer and Filler Block Dimensions (Not required if both loaded equally from above) N.T.S. <br />BCI8Joist Backer Block Filler blocking <br />Thickness Filler Block Thickness 1/8'min. I Small ap 2" min. <br />Series 1/8" gap 2" max. 4" max. I Web Stiffener Fastener Schedule <br />3/4" or 7/8" Joist Been" n . q Location <br />5000s 1.8/1.7 wood panels Two 3/4" wood panels or 2 x 1 0�9 I—L Series Depth End Intermediate <br />P, 9-1/2" 2-8d 2-_8d <br />, i 3 8d <br />1-1/8" or two 112" .4 BCI 5000s@1 11-7/8"! 2-8d <br />6000s 1.8/1-7 wood panels 2 x + 5/8" or 3/4" wood panel 14" 2-8d 5-8d <br />Clinch nails <br />9-1/2"_ 2-8d 2-8d <br />1-1 /8" or two 1/2" when BCI 6000se 11 -7/8" 2-8d 3-8d <br />6500s 1.8/1.7 2 x + 5/8" or 3/4" wood panel possible <br />wood panels BCI 6500se— 14" --- 2-8d 5-8d <br />1 1) Support back of web during nailing to prevent damage to V 16" 2-8d 6-8d <br />1-1 /8" or two 1/2" 11 -17/8" 2- - 8d 3-8d <br />602.0 2 x + 5/8" or 3/4" wood panel web -flange connection. -------- I 5-8d <br />wood panels Tight fit BCI 60SO 14" 2-8d i <br />2) Block solid between joists for full length of span. 16" 2-8d 6-8d <br />2 x lumber Double 2 x lumber 3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2" 1 min. 11 - 7_/_8_-__3-16d 3-16d <br />902.0 2x4/PIywood/OSB web stiffener BCI 90s8 14" 5-16d 5-16d <br />4) Place joists together and nail from each side with 2 rows of 1 Od nails required when indicated or 4" max. 16" 6- - 16d 6-16d <br />2x CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y8" GAP @ TOP sides by 6". - Hangers with sides not containing <br />top flange of joist. WEB STIFFENER <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1 900 pif max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />0, <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />11/16" <br />code for appropriate <br />Zor--20 <br />details in <br />One 1 Od box <br />areas=20 of high <br />sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam 0 <br />Boise Joist Blocking <br />tJqPT' (10d)i nail.q at 6" f)-c- <br />Provide adequate bearing <br />for each lapped joist. <br />10d nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />­­­ I—— . MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D <br />(se, <br />(KNOCKOUT EXEMPTS) <br />(see table below) D <br />6- (see table below) <br />DO NOT cut, notch <br />or drill flanges <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 pif max. along bearing wall <br />Required on interior walls: - for vertical load transfer Plumbing <br />Men load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load, bearing wall must stack over 7f =1 <br />b oc, <br />locking and wall or beam below.* <br />Joist <br />W When joists meet over wall, provide <br />he <br />1314 <br />13/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />Use 1 Odx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />611 1. A %2" ROUND HOLEMAY 611 611 0 NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN <br />THE WEB. PROVIDE AT Tln�OUND IN <br />R <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN IY2" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %2" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />N.T.S <br />Joist hanger <br />5/81 <br />THRU <br />BOLT <br />I.0 <br />SIMPS( <br />wl (22) - <br />NAILS I <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />=_ AND QUANTITY <br />)FFASTENERS <br />TYPICAL SIMPSON META12 <br />META12 TSS INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (112" wide min.) IT71.1 I [---I I I— — <br />.T <br />Nail with 10- 10d nails. �P <br />nstall tight to top flange, W, -A <br />SLEEVE THRU STEM <br />-OR <br />SEE PLAN FOR 44 <br />0 <br />4F 4' <br />FOUNDATION INFO <br />STEM FOUNDATION <br />Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />I � V1 -2" gap <br />1/4" <br />""Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />/46 X Joist <br />.1 -1 depth <br />D <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />/-- REINF. SEE PLAN <br />/ A/CCHASE4"PVC — (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />(WHEN <br />SIMPSON H10A <br />1 REQUIRED) <br />w/ (18) 1 Od x 1 1/2" <br />NAILS I <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION� <br />4 <br />',,7L A <br />L 4 <br />4. <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION <br />4 <br />0 4 0 <br />A <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE: <br />PENETRATION PLUMBING LINE <br />4-0 - <br />4 <br />4 <br />lie. <br />SEE FND. PLN. <br />SIZE & REINF, <br />> <br />0 co <br />0 <br />04 <br />CU U_ <br />-0 C) <br />C: C\l <br />_F_ <br />M 0 M <br />IN <br />C: -0 <br />C: <br />E < <br />< <br />> <br />M <br />a) > <br />E <br />0 <br />0 <br />1L, M <br />> LIJ <br />C13 <br />2 <br />C"> <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code <br />- <br />Residential 7th Edition. Engineers signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />9) .9 <br />W <br />N u. <br />0 <br />C-, P <br />(0 LL U- <br />0 <br />C-� <br />a, <br />A CP <br />r <br />ILNJ <br />z 2 z 0 <br />04 M L <br />LL a b < g =) <br />_J <br />0 <br />z Fl <br />D <br />—0 <br />z: <br />77 <br />V) <br />C1 <br />(U (D <br />4--J ,o <br />LU <br />0 LU <br />Ln <br />U) <br />L�u <br />< <br />_J <br />U_ <br />E <br />go <br />E <br />E <br />0 <br />01 <br />03 i� <br />C: <br />N., <br />0 <br />Z z <br />9 <br />ai <br />z IZO <br />0 M <br />01 <br />Z <br />WillCD <br />co <br />8 <br />z <br />8 t: <br />.2 T— <br />Eft <br />LO <br />_J <br />LO <br />LO <br />< <br />LO <br />J <br />CN <br />C:) <br />0 <br />U) <br />M <br />co <br />T_ <br />< <br />+-A <br />0 <br />0) <br />04 <br />0 <br />LO <br />Lo CO <br />0 <br />z <br />z <br />E a <br />E <br />0 <br />C <br />_J <br />JOB <br />NO 22-02385 <br />SCALE : AS NOTED <br />SHEEr NO. <br />SN 1 <br />