Laserfiche WebLink
gn <br />-3 r- <br />U-) <br />L0 <br />V) <br />3:j <br />-2 <br />CD, <br />C14 <br />C:1 <br />00 <br />r') <br />c"I <br />M <br />LO <br />L0 <br />Cr <br />V) <br />3j, <br />0 <br />-0 <br />C) <br />00 <br />rn <br />C14 <br />1,C) <br />L0 <br />0 <br />C) <br />E <br />0 <br />co <br />0 <br />E <br />0 <br />0 <br />.CD <br />_c_ <br />W <br />-0 <br />Q <br />C14 <br />C14 <br />C14 <br />C' <br />150A/200A INDOOR <br />ELECTRICAL SPECIFICATION PANEL CENTER <br />NOTES: <br />b # 14 copper to lights& outlets <br />,NEMA 1 00 # 12 copper to 20 amp ckts <br />50 AMP/ <br />ELECTRICAL CONTRACTOR 200 AMP 01 # 10-2 copper to WH <br />MUST VERIFY WITH THE <br />10 #10-3 copperto Dryer <br />SPECIFICATIONS FOR THE TYPE KI I <br />OF FIXTURE TO BE USED. LIGHT of <br />FIXTURES SHOWN ARE FOR METER IF <br />LOCATION PURPOSES. n 2/0 or 4/0 SER Alu <br />200 amp <br />150 amp r <br />UNDERGROUND <br />oc <br />[Disconn ct <br />POWER CO. FEED <br />INTERSYSTEK i <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVEC <br />NEC 17, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF NEC 17. <br />GENERAL ELECTRICAL NOTES. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 04.06.21 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-17, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />CODES AND THE LOCAL POWER CO. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor svrimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />F� <br />DUPLEX OUTLET ABOVE COUNTER <br />W. <br />WEATHERPROOF DUPLEX OUTLET <br />I—%- <br />PE5G F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />I <br />pi -OF <br />HALF -SWITCHED DUPLEX OUTLET <br />L.,r,,h <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6. <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />Iwo <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />FCH] <br />CHIMES (OPTIONAL) <br />�0 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />F9 <br />PUSH BUTTON SWITCH - DOOR BELL <br />@ <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />mpg <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />T <br />6�13 <br />OPT. CEILING FAN <br />(9�31 <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />PLUMBING RISER <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE:NTS <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN - ELEV-131 <br />SCALE: Y4"=l'-O" <br />C%a <br />0 <br />X <br />n <br />0 <br />0 CD <br />0 <br />,U) <br />W <br />J) <br />> <br />> <br />> (1) <br />. " <br />C14 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential <br />7th Edition. Engineet's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers <br />signature and seal. <br />U) <br />W <br />c­0 <br />'T E <br />C) to <br />C) ") 8 C'j <br />C) 04 <br />N I <br />C) <br />0 <br />0), * L� Lu <br />0 <br />IL <br />r- r-' - Lu <br />C4 C) U_ CL <br />M U_ LL CL Lu <br />Z <br />IX 0 <br />0 <br />r_ co 5 F <br />HE Lu <br />cc 0 _1 <br />Ca 04 M _, <br />W <br />021- M <br />Op <br />Z <br />LL <br />0 <br />00 - Z -1 <br />Lr) 04 LO <br />C0 <br />(N <br />< < L) <br />00 L) <br />Z <br />W <br />L <br />116 11 <br />V) <br />CD <br />4—J <br />LU <br />c:, <br />0 <br />LLJ <br />E <br />8 <br />0 <br />1Z <br />C13 <br />Z <br />< <br />LL. <br />cti E <br />CD- 0 <br />Z R <br />< <br />E U <br />CK) (6 <br />CL <br />< <br />-0 <br />Z <br />C=) <br />< z <br />�z <br />C14 <br />U) C: <br />z <br />0 <br />'.0 <br />.0 <br />Z' <br />'Z <br />Z <br />Z Z <br />Cn <br />CD <br />0 M <br />< <br />�O <br />W <br />.0 <br />z <br />C:) <br />0 <br />0 <br />2 <br />M <br />> LO <br />LO <br />LO <br />< <br />0 <br />=3 C) <br />N <br />_j <br />C) <br />T_ <br />U) 0 <br />< <br />0 <br />C14 <br />C'4 <br />C:) <br />C:) <br />64 <br />LO <br />04 <br />(N <br />E <br />6 <br />Z <br />170 <br />Z <br />E <br />cn <br />E <br />0 0 <br />0 _j <br />2? 6 <br />< <br />JOB <br />NO: <br />22-02383 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />