R502.5 Allowable girder spans. <br />The allowable spans of girders fabricated of dimension lumber sholl not <br />exceed the values set forth in Tables R502.5(l) and R502.5(2). <br />TABLE R502.5(l) <br />GIRDER SPANSo AND HEADER SPANSO FOR EXTERIOR BEARING WALLS <br />(Maximum spans for Douglas fir -larch, hem -fir, southern pine <br />and spruce-pine-firb and required number of jack studs) <br />GIRDERS AND HEADERS <br />SUPPORTING <br />SIZE <br />Building widthc (feet) <br />20 <br />28 <br />36 <br />SPAN <br />__d__ <br />NJ <br />SPAN <br />Njd <br />SPAN <br />Njd <br />Roof and ceiling <br />2-2x4 <br />3-6 <br />1 <br />3-2 <br />1 <br />2-10 <br />1 <br />2-2x6 <br />5-5 <br />1 <br />4-8 <br />1 <br />4-2 <br />1 <br />2-2x8 <br />1 6-10 <br />1 <br />5-11 <br />2 <br />5-4 <br />2 <br />2-2x10 <br />8-5 <br />2 <br />7-3 <br />2 <br />6-6 <br />2 <br />2-2xl2 <br />9-9 <br />2 <br />8-5 <br />2 <br />7-6 <br />2 <br />3-2x8 <br />8-4 <br />1 <br />7-5 <br />1 <br />1 6-8 <br />1 <br />3-2x10 <br />10-6 <br />1 <br />9-1 <br />2 <br />8-2 <br />2 <br />3-2x12 <br />12-2 <br />2 <br />10-7 <br />2 <br />9-5 <br />2 <br />4-2x8 <br />9-2 <br />1 <br />8-4 <br />1 <br />7-8 <br />2 <br />4-2x10 <br />11-8 <br />1 <br />10-6 <br />1 <br />9-5 <br />2 <br />4-2xl2 <br />14-1 <br />1 <br />12-2 <br />2 <br />10-11 <br />2 <br />Roof, ceiling and one <br />center -bearing floor <br />2-2x4 <br />3-1 <br />1 <br />2-9 <br />1 <br />2-5 <br />1 <br />2-2x6 <br />4-6 <br />1 <br />4-0 <br />1 <br />3-7 <br />2 <br />2-2x8 <br />5-9 <br />2 <br />5-0 <br />2 <br />4-6 <br />2 <br />2-2x10 <br />7-0 <br />2 <br />6-2 <br />2 <br />5-6 <br />2 <br />2-2x12 <br />8-1 <br />2 <br />7-1 <br />2 <br />6-5 <br />2 <br />3-2x8 <br />7-2 <br />1 <br />6-3 <br />2 <br />5-8 <br />2 <br />3-2x10 <br />8-9 <br />2 <br />7-8 <br />2 <br />6-11 <br />2 <br />3-2x12 <br />10-2 <br />2 <br />8-11 <br />2 <br />8-0 <br />2 <br />4-2x8 <br />8-1 <br />1 <br />7-3 <br />1 <br />6-7 <br />2 <br />4-2xlO <br />10-1 <br />1 <br />8-10 <br />2 <br />8-0 <br />2 <br />4-2x12, <br />11-9 <br />2 <br />10-3 <br />2 <br />9-3 <br />2 <br />Roof, ceiling and one <br />clear spon floor <br />2-2x4 <br />2-8 <br />1 <br />2-3 <br />1 <br />2-0 <br />1 <br />2-2x6 <br />3-11 <br />2 <br />3-3 <br />2 <br />2-11 <br />2 <br />2-2x 8 <br />5-0 <br />2 <br />4-2 <br />3 <br />3-9 <br />2 <br />2-2x1O <br />6-1 <br />2 <br />5-1 <br />3 <br />4-7 <br />3 <br />2-2x12 <br />7-1 <br />3 <br />5-10 <br />3 <br />5-3 <br />3 <br />3-2x8 <br />6-3 <br />2 <br />5-2 <br />2 <br />4-8 <br />2 <br />3-2x10 <br />7-7 <br />2 <br />6-4 <br />2 <br />5-8 <br />2 <br />3-2x12 <br />8-10 <br />2 <br />7-4 <br />3 <br />6-7 <br />2 <br />4- x <br />7-2 <br />1 <br />6-0 <br />2 <br />5-5 <br />2 <br />4-2x10 <br />8-9 <br />2 <br />7-4 <br />2 <br />6-7 <br />2 <br />4-2x 12 <br />10-2 <br />2 <br />8-6 <br />2 <br />7-8 <br />2 <br />Roof, ceiling and two <br />center -bearing floors <br />2-2x4 <br />2-7 <br />1 <br />2-3 <br />1 <br />2-0 <br />1 <br />2-2x6 <br />3-9 <br />2 <br />3-3 <br />2 <br />2-11 <br />2 <br />2-2x 8 <br />4-9 <br />2 <br />4-2 <br />2 <br />3-9 <br />2 <br />2-2xl0 <br />5-9 <br />2 <br />5-1 <br />2 <br />4-7 <br />3 <br />2-2x12 <br />6-8 <br />2 <br />5-10 <br />3 <br />5-3 <br />3 <br />3-2x8 <br />5-11 <br />2 <br />5-2 <br />2 <br />4-8 <br />2 <br />3-2x10 <br />7-3 <br />2 <br />6-4 <br />2 <br />5-8 <br />2 <br />3-2x12 <br />8-5 <br />2 <br />7-4 <br />2 <br />6-7 <br />2 <br />4-2x8 <br />6-10 <br />1 <br />6-0 <br />2 <br />5-5 <br />2 <br />4-2x101 <br />8-4 <br />2 <br />7-4 <br />2 <br />6-7 <br />2 <br />4-2x 12 <br />9-8 <br />2 <br />8-6 <br />2 <br />7-8 <br />1 2 <br />Roof, ceiling and two <br />clear spon floor <br />2-2x4 <br />2-1 <br />1 <br />1-8 <br />1 <br />1-6 <br />2 <br />2-2x 6 <br />3-1 <br />2 <br />2-8 <br />2 <br />2-4 <br />2 <br />2-2x 8 <br />3-10 <br />2 <br />3-4 <br />2 <br />3-0 <br />3 <br />2-2x10 <br />4-9 <br />2 <br />4-1 <br />3 <br />3-8 <br />3 <br />2-2x12 <br />5-6 <br />2 <br />4-9 <br />3 <br />1 4-3 <br />3 <br />3-2x8 <br />4-10 <br />2 <br />4-2 <br />2 <br />3-9 <br />2 <br />3-2x10 <br />5-11 <br />2 <br />5-1 <br />2 <br />4-7 <br />2 <br />3-2x 12 <br />6-10 <br />2 <br />5-11 <br />3 <br />5-4 <br />2 <br />4-2x8 <br />5-7 <br />2 <br />4-10 <br />2 <br />4 -4 <br />E2 <br />4-2xlO <br />6-10 <br />2 <br />5-11 <br />2 <br />5-3 <br />2 <br />14-2x121 <br />7-11 <br />2 <br />6-10 <br />2 <br />6-2 <br />3 <br />TABLE R502,5(2) <br />GIRDER SPANSCIAND HEADER SPANSO FOR INTERIOR BEARING WALLS <br />(MAXIMUM SPANS FOR DOI, -LARCH, HEM -FIR, SOUTHERN PINE <br />,�LAS FIR <br />AND SPRUCE -PINE -FIR AND REQUIRED NUMBER OF JACK STUDS) <br />GIRDERS AND HEADERS <br />SUPPORTING <br />SIZE <br />Building widthc (feet) <br />20 <br />28 <br />36 <br />SPAN <br />Njd <br />SPAN <br />Njd <br />SPAN <br />Njd <br />One floor only <br />2-2x4 <br />3-1 <br />1 <br />2-8 <br />1 <br />2-5 <br />1 <br />2-2x6 <br />4-6 <br />1 <br />3-11 <br />1 <br />3-6 <br />1 <br />2-2x8 <br />5-9 <br />1 <br />5-0 <br />2 <br />4-5 <br />2 <br />2-2x10 <br />7-0 <br />2 <br />6-1 <br />2 <br />5-5 <br />2 <br />2-2xl2 <br />8-1 <br />2 <br />7-0 <br />2 <br />6-3 <br />2 <br />3-2x8 <br />7-2 <br />1 <br />6-3 <br />1 <br />5-7 <br />2 <br />3-2x10 <br />8-9 <br />1 <br />7-7 <br />2 <br />6-9 <br />2 <br />3-2x12 <br />10-2 <br />2 <br />8-10 <br />2 <br />7-10 <br />2 <br />4-2x8 <br />9-0 <br />1 <br />7-8 <br />1 <br />6-9 <br />2 <br />4-2xI0 <br />10-1 <br />1 <br />8-9 <br />1 <br />7-10 <br />2 <br />4-2x12 <br />11-9 <br />1 <br />10-2 <br />2 <br />9-1 <br />2 <br />Two floors <br />2-2x4 <br />2-2 <br />1 <br />1-10 <br />1 <br />1-7 <br />1 <br />2-2x6 <br />3-2 <br />2 <br />2-9 <br />2 <br />2-5 <br />2 <br />2-2x8 <br />4-1 <br />2 <br />3-6 <br />2 <br />3-2 <br />2 <br />2-2xlO <br />4-11 <br />2 <br />4-3 <br />2 <br />3-10 <br />3 <br />2-2x12 <br />5-9 <br />2 <br />5-0 <br />3 <br />4-5 <br />3 <br />3-2x8 <br />5-1 <br />2 <br />4-5 <br />2 <br />3-11 <br />2 <br />3-2x10 <br />6-2 <br />2 <br />5-4 <br />2 <br />4-10 <br />2 <br />3-2x12 <br />7-2 <br />2 <br />6-3 <br />2 <br />5-7 <br />3 <br />4-2x8 <br />4-2 <br />2 <br />5-3 <br />2 <br />4-8 <br />2 <br />4-2xlO <br />7-2 <br />2 <br />6-2 <br />2 <br />5-6 <br />2 <br />4-2x12 <br />8-4 <br />2 <br />7-2 <br />2 <br />6-5 <br />For Sl: 1 inch = 25.4 mm, 1 foot=304.8mm <br />a. Spans are given in feet and inches. <br />b. Tabulated values assume #2 grade lumber. <br />c. Building width is measured perpendicular to the ridge. For widths between <br />those shown, spans are permitted to be interpolated. <br />d. NJ - Number of jack studs required to support each end. Where the number of <br />required jack studs equals one, the header is permitted to be supported by an <br />approved framing anchor attached to the full -height wall stud and to the <br />header. <br />R502.2.15 Bearing. The ends of each joist, beomor girder shall hove not less than 1.5 inches (38 mm) <br />of bearing on wood or metal and not less than 3 inches (76 mm) on mosonry or concrete except where <br />supported on a 1-inch-by-4-inch (25.4 mm by 102 mm) ribbon strip and nailed to the adjacent stud or <br />by the use of approved joist hangers. <br />R502.2.6.1 Floor systems [IRC R502.5.1]. Joists framing from opposite sides over a bearing support <br />sholl lop a minimum of 3 inches (76 mm) and shot[ be nailed together with a minimum three 10d face <br />�Oils. Atwood or metal splice with strength equal to or greater than that provided by the nailed lop <br />is permi ted. <br />R502.2.6.2 Joist framing [IRC R502.6.2]. Joists framing into the side of a wood girder sholl be <br />supported by approved framing anchors or on ledger strips not less than nominal 2 inches by 2 inches <br />(51 mm by 51 mm). <br />R502.2.7 Lateral restraint at Supports (IRCR502.7]. Joists shall be supported laterally at the ends <br />by full -depth solid blocking not less than 2 inches (51 mm) nominal in thickness; or by attachment to <br />a full -depth header. bond, or rim joist, or to an adjoining stud; or sholl be otherwise provided with <br />lateral support to prevent rotation. <br />Exception: Reserved. <br />R502.2.7.1 Bridging [[RC R502.7.1]. Joists exceeding a nominal 2 inches by 12 inches (51 mm by 305 an) <br />sholl be supported laterally by solid blocking, diagonal bridging (wood or metal). or a continuous <br />1-inch-by-3-inch (25.4 mm by 76 mm) strip noiled across the bottom of joists perpendicular to joists <br />at intervals not exceeding 8 feet (2438 mm). <br />R502.2.8 Drilling and notching [IRC R502.8]. Structural floor members shall not be cut, bored or <br />notched in excess of the limitations specified in this section, See Figure R502.2.8. <br />R502.2.8.1 Sown lumber[[RC R502.8.1]. Notches in solid lumber joists, rafters and beams shot) not <br />exceed one -sixth of the depth of the member, sholl not be Longer than one-third of the depth of the <br />member and shall not be located in the middle one-third of the span. Notches at the ends of the member <br />sholl not exceed one-fourth the depth of the member. The tension side of members 4 inches (102 mm) or <br />greater in nominal thickness sholl not be notched except at the ends of the members. The diameter of <br />holes bored or cut into members shalt not exceed one-third the depth of the member. Holes shall not be <br />closer than 2 inches (51 mm) to the top or bottom of the member, or to any other hole located in the <br />member. Where the member is also notched, the hole shall not be closer than 2 inches (51 mm) to the <br />notch. <br />R502.2.8.2 Engineered wood products [IRC R502.8.2). Cuts, notches and holes bored in trusses, <br />structural composite lumber, structural glue -laminated members or I -joists are prohibited except where <br />permitted by the manufacturer's recommendations or where the effects of such alterations are <br />;$; 11 nsi-I-r-A in the desi n of the mber b a re istered desi n -rofessional <br />ROOF SkEAT1411,* FASTENING SCHEOULE &,bc,d,e <br />Dd Common (0.131 x 2-1/2 inches) or Ring-&-ank (0.135, X 2-112 inc-hes) <br />(Except Where Noted) for Exposure 8, Enclosed SuIldIngs, Roof Framing Spaced 24 Inches <br />o.c. or Less <br />Roof Fastening Zone <br />Overl,-ang <br />Wind <br />Main <br />Sheathing -to -Gable <br />(saves) <br />velocitv <br />Roar <br />End -Wall FramingO <br />(3 - Second <br />Panel <br />1 <br />2 <br />3 2 3 <br />2 <br />3 <br />Gust) <br />Location <br />Fastening Schedule (Inches on center) <br />Supported Panel <br />& <br />(0 <br />6 <br />150 mph rQ <br />and and edge$ <br />3h <br />panel field <br />ep <br />4 <br />3 <br />4 <br />3 <br />Supported Panal <br />120 mph CA3 <br />and arid edges <br />6 <br />6 <br />6 <br />3 <br />Panel Field <br />12 <br />6 <br />4 <br />ro <br />4 <br />Supported Panel <br />C30 mph <br />end and colgee, <br />ro <br />6 <br />ro <br />Parel field <br />12 <br />12 <br />& <br />a. Specific qravit� (G) of lumber and panels "it be 0.42 or greater. <br />b. For Exposure 5 and a 2-foot overhang, <br />C. For median roor height 35 rest or lees, <br />d. Gable wall height or a rest or lose From top Floor calling to roof peak. <br />a. Provide adequate uplift hardware at true& -to -wall connections. Such <br />connections are be�oncl the scope of this publication, <br />r. When wind speacl is 110 mph or greater and whom madian roor height is between <br />25 and 35P Feet, use gk� ring shark malls (0.135 x 2-1/2 Inclne6AUithln 48 Inches of <br />gable end walls. (IRG Table R602.3, Footnote r) <br />g, When wind speed is 100 mph or greater, block panel edges perpendicular to <br />gabis-end-waii Framing members In the first two ba�6 or Framing. 151ocklne shall be <br />spaced a maximum or 4 rest oc. (Wood Frame Construction Manual, Section 3.5.5) <br />In. 10d ring -shank na Its (0.145x 3 inchn). <br />i. Blocking not required. <br />ROOF FASTENING ZONES FOR WINO UPLIFT <br />Zones 1,2 and 3 shown below indicate areas or the roor that maV have different Fastening <br />requirements. <br />GA15LE ENr-> WALL WALL LINE <br />Lu <br />Z <br />2 <br />-A <br />PIVERW <br />VEWA <br />2 JR.-, <br />3­ 2 <br />Cx,40 L E <br />FRCPOF <br />2- <br />-2 - <br />It <br />2 <br />:F- <br />.......... <br />\WALL LINE <br />X3 OVERHAW-4 3 OVERHAW-2 WALL LINE \ GA15LE r=NC> WALL <br />C)l6tance a -4 Ft. In moot caaes (10% or least bullollne width or 0.4 times building height, <br />whichever is smaller, but not !ass than either 49. or least building width or 3 ft.) <br />ROOF 01,4PHRAM NAILING SCHEDULE (GABLES) <br />Spec co y co I V COLLAR TIE Wo (MIN.) EVERY <br />R502.2.9 Fastening [IRC R502.91. Floor framing shall be noiled in accordance with Table R602.2(l) <br />.1 1 1 k 1 A f! n ;. U-4 f^ u art floor fromin ositive connections OTHER RAFTER T-0" OR LONGER <br />ere pos s an eam or 9 r er cons u, o KPI 1J, V <br />sholl be provided to ensure against <br />uplift and lateral displacement. <br />For SI: I inch = <br />25.4 mm, 1 pound per square <br />foot = 0,0479 <br />kN/m2. <br />R502.2.10 Framing of openings [IRC R502.10], Openings in floor froming shall be fromed with a header <br />a. Spans are given <br />in feet and inches. <br />and trimmer joists. When the header <br />joist span does not exceed 4 feet (1219 mm). the header joist may <br />b. Tabulated values <br />assume #2 grade lumber. <br />be a Single member the some size as <br />the floor joist. Single trimmer joists may be used to carry 0 <br />c. Building width <br />is measured perpendicular to <br />the ridge. <br />For widths between <br />single header joist that is iocatedwithin <br />3feet (914 mm) of the trimmer joist bearing. <br />those shown, spans <br />are permitted to be interpolated. <br />When the header joist span exceeds 4 <br />feet (1219mm), the trimmer joists ond the header joisL shall be <br />d. NJ - Number of <br />jack studs required to support <br />each end. <br />Where the number of <br />doubled and of sufficient crass section <br />to support the floor joists framing into the header. Approved <br />required jack studs <br />equals one, the header is <br />permitted to <br />be supported <br />hangers shall be used for the header <br />joist to trimmer joist connections when the header joist span <br />by an approved framing <br />anchor attached to the <br />full -height <br />wall stud and to the <br />exceeds 6 feet (1829 mm). Tail joists <br />over 12 feet (3658 mm) long sholl be supported at the header by <br />framing anchors or on ledger strips <br />not less than 2 inches by 2 inches (51 mm by 51 mm). <br />header. <br />e. Reserved. <br />R502.3 Design and construction where <br />wind speed is 100 mph or greater. Floor froming of light-frome <br />wood construction shall be designed <br />and constructed in accordance with the provisions of Section <br />24" MIN. LAP <br />R301 . 2. 1. 1, Section R502. 1. <br />`113 OR 114 REINFORCING BAR <br />$$3 4 #4 LAP SPLICE. <br />25" "IN. LAP <br />---#5 REINFORCING BAR <br />#E� LAP SPLICE. <br />In;_," mil"i I Af= <br />'CW r�%6-11NT �.o�r'%N�11'4�.4 6.'P"r�% <br />A fm &P L I C rm. <br />A')" MINJ I Ag� <br />07 LAP SPLICE. <br />InIl <br />05 REINFORCING BAR <br />STM. SO"' 5END, <br />RE5AR SPLICING 4 LAP DETAIL. <br />F=ILA5TEFR <br />I mAxl <br />r�nr <br />"A" 4_0TO-00018010104118010010 <br />VERTICAL REINFORCEMENTS <br />I SCHEDULE MASON;VTO <br />5' PLATE HEIGHT 5'-0" O.C. <br />10' PLATE HEIGHT ro'-V C.C. <br />12' PLATE HE16HT 4'-0" O.C. <br />"A" 14' PLATE HEIGHT z 2'-0" O.C. MA><. / PILASTERS im 101-011 O.C. <br />AT EACH CORNIER 4 BOTH SIDES OF DOORS 4 WINDOWS OPENING5 <br />(OVER BEFORE 4 AFTER SHEARWALL SEGMENTS, 4 <br />(9) 56R5 6 EA. SIDE OF OPENING OVER 12'-0" <br />LAP DI&TANC <br />1­7_ <br />UP, <br />Z <br />C.M.U. WALL <br />W <br />CORNER CONTINIT"r 4 WALL REINFORCEMENT. <br />BLOCKING E3ELOW RIDGE <br />25," MIN. LAP <br />Fr_ <br />(1) 05 DOWEL <br />IN CORNER <br />2Xro VERTIC;AL 5GA5 OR <NEEWALL MID-f=OINT <br />IN RAFTER UJ/ RAFTER SPAN LENGTH GREATER <br />THAN 14 FT OR LONGER. <br />CONN W1 4-106 NAILS AT T01= 4 HURRIGANE <br />C:L11= 6 50TTOM. <br />2X& (MIN.) NO. 2 'T'fm <br />VALLE�' FRAMING (TYf=. SIMPSON L5TA12 <br />(OR EQUAL) <br />2Xe NO, 2 6PF PLYWOOD SHEATHING <br />RIDGE BOARD Tr <br />(4) 10d Q RIDGE <br />E30ARD END <br />TRU65E& BELOW 6HEATHEI) PRIOR <br />To vALLEY FRAMING INSTALLATION <br />OR &'-0" O.C. TOP C;HORD <br />SiMf=SON LSTA12 STRAP OR SIMPSON A22 TIE <br />I& EA RAFTER LU/ 10-10d NAILS <br />(T`rf=.) <br />2X(o CONT. W/SLEEPER, CLIPPED <br />OR STRAPPED TO TRUSS 5ELOW <br />4r FRAMING DETAIL <br />25," MIN. LAP <br />L <br />(1) 05 DOWEL <br />IN CORNER <br />FOOTING 4 STEMWALL RRINFORCEMENT <br />TABLE 2304. 9. 1 <br />FASTENING SCHEDULE <br />CONNECTION <br />FASTENINGo,m <br />LOCATION <br />1. Joist to sill or girder <br />3-8d common (2 112" x 0. 131") <br />3-3" x 0. 131" nails <br />toeno i 1 <br />3-3" 14 gage staples <br />2. Bridging to joist <br />2-8d common (2 112" x 0. 131") <br />2-3" x 0,131" nails <br />toenail each end <br />2-3" 14 gage staples <br />3. 1"X 6" subfl car or less to each j ois t <br />2d-8d common (2 112" x 0. 131") <br />face nail <br />4. Wider than 1" X 6" subfloor to each joist <br />3d-8d common �2 112 11 x 0. 131"� <br />face noil <br />5. 2" 5ubfloor toj oist or girder <br />2d-16d common(3 112" x 0. 162'" ) <br />blind and face noil <br />6. Sole pla te toj ois t or bl ocking <br />16d ( 3 1 /2:: x 0, 135" ) a t 16" a. c. <br />3 x 0 . 131 nails at 8" o.c. <br />typical face noil <br />3" 14 gage staples per 12" <br />Sole plate to joist or blocking at braced wall panel <br />3-16d ( 3 1 /2" x 0. 135" ) a t 16" <br />4-3" x 0,131" nails at 16" O-c, <br />braced wall panels <br />4-3" 14 qaqe staples per 16" <br />7. Top plate to stud 2 16d common <br />2-16d common (3 112" x 0. 162") <br />3-3" x 0.131" noils <br />end noil <br />3-3" 14 goge staples <br />8. Stud to sole plate <br />4-8d common �2 1/2" x 0. 131"') <br />4 -3" x 0. 131 no i Is <br />toe no i 1 <br />3-3" 14 gage staples <br />2-16d common (3 112" x 0.162" <br />3-Y x 0.131" noils <br />end nail <br />3-3" 14 gage staples <br />9. Double Studs <br />1 6d ( 3 112" x 0. 162" ) a t 24" o. c. <br />3"x 0. 131" nails a t 8" o,c. <br />face nail <br />3" 14 gage staple at 8" o.c. <br />10. Double top pla tes <br />16d (3 112" x 0. 135"at 16" 0. C, <br />3 x 0 . 131" noils at 12" o.c. <br />typical face nail <br />3" 14 gage staple at 12" a. c. <br />Double top plates <br />8-16d common �3 1/2" x 0. 162" <br />12-3" x 0.131 , nails <br />lop splice <br />12-3" 14 gage typical face nail <br />11. Blocking between joists or rof ters to top plate <br />3-8d common �2 1/2" x 0. 131") <br />3-3" x 0 . 131' no I Is <br />toe nail <br />3-3" 14 gage staples <br />12. Rim joist to top plate <br />8d (2 112" x 0. 131") at 6" a. c. <br />3" x 0.131" noils at 6" o.c. <br />toe nail <br />3" 14 cioce staples at 6" o. c. <br />13. Top plates, lops and intersections <br />2-16d comma �3 112" x 0. 162") <br />3-3" x 0.131 , nails <br />face nail <br />3-3" 14 gage staples <br />14. Continuous header, two pieces <br />16d common (3 112" x 0. 162"� <br />16" o.c. along edge <br />15. Ceiling joists to plate <br />3-8d common (2 112" x 0.131") <br />5-3" x 0. 131" nails <br />toe no 1 1 <br />5-3" 14 gage staples <br />16. Continuous header to stud <br />4-8d common (2 112" x 0. 131") <br />toe no i I <br />CONNECTION <br />FASTENING 0, m <br />LOCATION <br />17. Ceiling joists, lops over partitions <br />3-16d common (31/7 x 0. 162")min, <br />see Sec t i on 2308. 10. 4. 1, Tob I e 2308. 10. 4. 1) <br />Table 2308. 10. 4. 1 <br />face nail <br />4-3"x 0.131" nails <br />4-3*' 14 gage staples <br />18. Ce i I i ng j . oists to parallel rafters <br />3-16d common ( 3 112" x 0. 162" ) mi n, <br />see Section 2308. 10. 4. 1, Table 2308. 10. 4. 1) <br />Table 2308. 10. 4. 1 <br />face nail <br />4-3"x 0.131" nails <br />4-3" 14 gage staples <br />19. Ra fter topla te <br />3-8d common �2 112" x 0.131") <br />(see Section 2308. 10. 1, Table 2308. 10. 1) <br />3-3" x 0. 131 . nails <br />toe nai 1 <br />3-3" 14gage s toples <br />20. 1" diagonal brace to each stud and plate <br />2-8d common 2 1/2" x 0. 13 17rY__ <br />2-3" x 0.131 noils <br />face nail <br />2-3" 14 goge sta�les <br />21. 1"x 8"sheoLhing to each bear ing wall <br />3-8d common (3 112" x 0. 162") <br />face noi 1 <br />22. Wider than 1"X 8" sheathing to each bearing <br />3-8d common (3 112" x 0. 162") <br />face noi 1 <br />23. Built-up corner studs <br />16d common,,(3 1/2" x 0. 162") <br />24" o. c. <br />3"x 0,131 noils <br />16" o.c. <br />3" 14 gage s Loples <br />16" o.c. <br />24. Built-up girder and beams <br />20d common ( 4" x 0. 192") T2ff- a. -c. <br />f <br />3" x 0.131" nail at 24" o.c. <br />face no!] at top and bottom <br />3" 14 gage staple at 24" o.c. <br />staggered on opposite sides <br />2-20d common (4" x 0. 192" ) <br />3-3" x 0,131 . nails <br />face nail at ends and at each <br />3-3" 14 gage staples <br />splice <br />25. 2" planks <br />16d cornmon( 3 1�2" x 0. 162") <br />a teach bearing <br />26. Collor tie to rafter <br />3-10d common (3- x 0. 148" ) <br />4-3" x 0.131" nails <br />face nail <br />4-3" 14 clocie stoDles <br />27. Jack rofter toh ip <br />3-10d common (3" x 0. 148") <br />4 -3" x 0. 131" nails <br />toe no i 1 <br />4-3" 14 gage staples <br />2-16d common �3 112" x 0.162") <br />3-3" x 0.131 'nails <br />face nail <br />3-3" 14 gage staples <br />28. Roof rofter to 2-by ridge beorn <br />2-16d common �3 112" x 0. 162") <br />toe nail <br />3-3" x 0.131' nails <br />3-3" 14 gage staples <br />2-16d common�,3 112" x 0. 162") <br />3-3" x 0. 131 noils <br />face nail <br />3-3" 14 gage staples <br />29. Joist to bond joist <br />3 - 16d common (3 112" x 0. 162") <br />face noil <br />5-3" x 0.131" nails <br />5-3" 14 clocle staples <br />30. Ledger strip <br />3 - 16d common (3 112" x 0.162") <br />4-3" x 0. 131" noils <br />face nail <br />4-3" 14q aq e s toples <br />31, Wood structural panels and particleboard:b <br />1/2" and <br />6dc,l <br />SubfLoor, roof and wall sheathing (to framing): <br />less <br />2 3/8" x 0, 113" no i In <br />1 3/4" 16 gageo <br />15/32" in t 0 <br />8d common (roofs in <br />19/32 q <br />110-140 mph (Exp. B) <br />19/32 to <br />3/4" <br />6 inch o,c, edges and <br />8dd or 6d e <br />intermediate. 4 inch o.c. at <br />2 3/8"x 0.113 nailP <br />component and cladding edge <br />7/8" to 1" <br />2 " 16 gogeP <br />strip #3 (referto Figure <br />8dc <br />6-3 of ASCE 7) <br />Single Floor (combinati on subfloor -underl oymen t <br />1 1/8" to 1 <br />10dd or 8de <br />to froming): <br />1/4" <br />3/4" and <br />6de <br />less <br />7/8" to 1" <br />8,e <br />1 1 /8" t 0 1 <br />10dd 8de <br />1 /4" <br />or <br />32, Panel siding( to fr aming) <br />1/2" or less <br />6df <br />5/8" <br />8d f <br />33, Fiberboard sheathing:g <br />112" <br />No. 11 goge roofing noi[h <br />6d common no i I (2"x 0 11 ?1.) <br />No. 16 gage staple h <br />25/32" <br />No. 11 gage roofing noi[ <br />8d common nail (2 1/2*x 0.13 1") <br />No. 16 gage staple 1 <br />34, Interior paneling <br />1 /4" <br />4di <br />3/8" <br />6d k <br />For SI: 1 inch =25.4 mm. <br />a. Common or box noils are permitted to be used except where otherwise stated. <br />b. Nails spaced at 6 inches on center at edges, 12 inches at intermediate supports except 6 inches at supports where spons are 48 Inches or more. For <br />nailing of wood structural panel and particleboard diaphragms and shear wolis, refer to Section 2305. Nails for wall sheathing are permitted to be <br />common, box or cosing. <br />c. Common or deformed shank (6d - 2' - 0. 113' ; 8d - 21/22 - 0. 13 12 10d - 3' - 0. 148' <br />d. Common (6d - 2' - 0. 113' ; 8d - 2112 2 x 0. 13 1 2 ; 10d - 3 2 x 0. 1482 <br />a. Deformed shank (6d - 22 x 0. 113 2 8d - 2112' x 0. 131' ; 10d - 32 x 0. 148' <br />f. Corrosion -resistant siding (6d 17 /82 . 0, 1 062 ; 8d - 23/82 xO.128') or casing (6d - 2' W 0. 0992 ; 8d - 21/2 2 w 0. 1132 ) no I I. <br />9. Fasteners spaced 3 inches on center at exterior edges and 6 inches or) center at intermediate supports, when used as structural sheathing. Spacing <br />shot] be 6 Inches <br />on center on the edges and 12 inches on center at intermediate supports for nonstructural applications. <br />h. Corrosion -resistant roofing noils with 7/16-inch-diameter head and 11/2-inch length for 1/2-inch sheathing and I 3/4-inch length for 25/32-inch <br />sheathing. <br />I. Corrosion -resistant staples with nominal 7/16-inch crown and I 1/8-inch length for 1/2-inch sheathing and I 1/2-Inch length for 25/32-inch <br />sheathing. Panel supports <br />at 16 inches (20 inches if strength axis in the long direction of the panel, unless otherwise marked). <br />j. Casing ( 21/2' X 0� 0802 ) or finish (2112' - 0. 072' ) nails spaced 6 inches on panel edges, 12 Inches at intermediate supports. <br />k. Panel supports at 24 Inches. Casing or finish nails spaced 6 inches on panel edges, 12 Inches at Intermediate supports. <br />1. For roof sheathing applications, 8d nails (21/22 x 0. 113 2 ) are the minimum required for wood structural panels. <br />m. Staples sholl have a minimum crown width of 7/16 inch. <br />n. For roof sheathing applications, fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports. <br />a. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports for subfloor and wol I sheathing and 3 inches on center at edges, 6 <br />inches at <br />inte r mediate supports for roof sheathing. <br />p, Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports. <br />2 <br />(D <br />r_ <br />.0 <br />CA <br />0 <br />E <br />0 <br />L) <br />co <br />C*4 <br />a. <br />0 <br />0 <br />