Laserfiche WebLink
R502.5 Allowable girder spans. <br />The allowable spans of girders fabricated of dimension lumber shall not <br />exceed the values set forth in Tables R502.5(1) and R502.5(2). <br />TABLE R502. 5( 1) <br />GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS <br />(Maximum spans for Douglas fir -larch, hem -fir, southern pine <br />and spruce-pine-firb and required number of jack studs) <br />GIRDERS AND HEADERS <br />SUPPORTING <br />SIZE <br />Building widthc (feet) <br />20 <br />28 <br />36 <br />SPAN <br />NJd <br />SPAN <br />Njd <br />SPAN <br />NJ <br />Roof and ceiling <br />2-2x4 <br />3-6 <br />1 <br />3-2 <br />1 <br />2-10 <br />1 <br />2-2x6 <br />5-5 <br />1 <br />4-8 <br />1 <br />4-2 <br />1 <br />2-2x8 <br />6-10 <br />1 <br />5-11 <br />2 <br />5-4 <br />2 <br />2-2x10 <br />8-5 <br />2 <br />7-3 <br />2 <br />6-6 <br />2 <br />2-2xl2 <br />9-9 <br />2 <br />8-5 <br />2 <br />1 7-6 <br />2 <br />3-2x8 <br />8-4 <br />1 <br />7-5 <br />1 <br />6-8 <br />1 <br />3-2x10 <br />10-6 <br />1 <br />9-1 <br />2 <br />8-2 <br />2 <br />3-2x12 <br />12-2 <br />2 <br />10-7 <br />2 <br />9-5 <br />2 <br />4-2x8 <br />9-2 <br />1 <br />8-4 <br />1 <br />7-8 <br />2 <br />4-2x1O <br />11-8 <br />1 <br />10-6 <br />1 <br />9-5 <br />2 <br />4-2x12 <br />14-1 <br />1 <br />12-2 <br />2 <br />10-11 <br />2 <br />Roof, ceiling and one <br />center -bearing floor <br />2-2x4 <br />3-1 <br />1 <br />2-9 <br />1 <br />2-5 <br />1 <br />2-2x6 <br />4-6 <br />1 <br />4-0 <br />1 <br />3-7 <br />2 <br />2-2x8 <br />5-9 <br />2 <br />5-0 <br />2 <br />4-6 <br />2 <br />2-2x10 <br />7-0 <br />2 <br />6-2 <br />2 <br />5-6 <br />2 <br />2-2x12 <br />8-1 <br />2 <br />7-1 <br />2 <br />6-5 <br />2 <br />3-2x8 <br />7-2 <br />1 <br />6-3 <br />2 <br />5-8 <br />2 <br />3-2x10 <br />8-9 <br />2 <br />7-8 <br />2 <br />6-11 <br />2 <br />3-2x12 <br />10-2 <br />2 <br />8-11 <br />2 <br />8-0 <br />2 <br />4-2x8 <br />8-1 <br />1 <br />7-3 <br />1 <br />6-7 <br />2 <br />4-2x10 <br />10-1 <br />1 <br />8-10 <br />2 <br />8-0 <br />2 <br />4-2x12 <br />11-9 <br />2 <br />10-3 <br />2 <br />9-3 <br />2 <br />Roof, ceiling and one <br />clear span floor <br />2-2x4 <br />2-8 <br />1 <br />2-3 <br />1 <br />2-0 <br />1 <br />2-2x6 <br />3-11 <br />2 <br />3-3 <br />2 <br />2-11 <br />2 <br />2-2x8 <br />5-0 <br />2 <br />4-2 <br />3 <br />3-9 <br />2 <br />2-2x10 <br />6-1 <br />2 <br />5-1 <br />3 <br />4-7 <br />3 <br />2-2x12 <br />7-1 <br />3 <br />5-10 <br />3 <br />5-3 <br />3 <br />3-2x8 <br />6-3 <br />2 <br />5-2 <br />2 <br />4-8 <br />2 <br />3-2x10 <br />7-7 <br />2 <br />6-4 <br />2 <br />5-8 <br />2 <br />3-2x12 <br />8-10 <br />2 <br />7-4 <br />3 <br />1 6-7 <br />2 <br />4-2x8 <br />7-2 <br />1 <br />6-0 <br />2 <br />5-5 <br />2 <br />4-2x10 <br />8-9 <br />2 <br />7-4 <br />2 <br />6-7 <br />2 <br />4-2x12 <br />10-2 <br />1 2 <br />8-6 <br />2 <br />7-8 <br />2 <br />Roof, ceiling and two <br />center -bearing floors <br />2-2x4 <br />2-7 <br />1 <br />2-3 <br />1 <br />2-0 <br />1 <br />2-2x6 <br />3-9 <br />2 <br />3-3 <br />2 <br />2-11 <br />2 <br />2-2x8 <br />4-9 <br />2 <br />4-2 <br />2 <br />3-9 <br />2 <br />2-2x10 <br />5-9 <br />2 <br />5-1 <br />2 <br />4-7 <br />3 <br />2-2x12 <br />6-8 <br />2 <br />5-10 <br />3 <br />5-3 <br />3 <br />3-2x8 <br />5-11 <br />2 <br />5-2 <br />2 <br />4-8 <br />2 <br />3-2x10 <br />7-3 <br />2 <br />6-4 <br />2 <br />5-8 <br />2 <br />3-2x12 <br />8-5 <br />2 <br />7-4 <br />2 <br />6-7 <br />2 <br />4-2x8 <br />6-10 <br />1 <br />6-0 <br />2 <br />5-5 <br />2 <br />4-2x10 <br />8-4 <br />2 <br />7-4 <br />1 2 <br />6-7 <br />2 <br />4-2xl2 <br />9-8 <br />2 <br />8-6 <br />2 <br />7-8 <br />2 <br />Roof, ceiling and two <br />clear span floor <br />2-2x4 <br />2-1 <br />1 <br />1-8 <br />1 <br />1-6 <br />2 <br />2-2x6 <br />3-1 <br />2 <br />2-8 <br />2 <br />2-4 <br />2 <br />2-2x8 <br />3-10 <br />2 <br />3-4 <br />2 <br />3-0 <br />3 <br />2-2x10 <br />4-9 <br />2 <br />4-1 <br />3 <br />3-8 <br />3 <br />2-2x12 <br />5-6 <br />2 <br />4-9 <br />3 <br />4-3 <br />3 <br />3-2x8 <br />4-10 <br />2 <br />4-2 <br />2 <br />3-9 <br />2 <br />3-2x10 <br />5-11 <br />2 <br />5-1 <br />2 <br />4-7 <br />2 <br />3-2x12 <br />6-10 <br />2 <br />5-11 <br />3 <br />5-4 <br />1 2 <br />4-2x8 <br />5-7 <br />2 <br />4-10 <br />2 <br />4-4 <br />2 <br />4-2x10 <br />6-10 <br />1 2 <br />5-11 <br />2 <br />5-3 <br />2 <br />4-2x12 <br />7-11 <br />1 2 <br />6-10 <br />2 <br />6-2 <br />3 <br />For SI: 1 inch = 25.4 mm, 1 pound per square foot = 0.0479 kN/m2. <br />a. Spans are given in feet and inches. <br />b. Tabulated values assume #2 grade lumber. <br />c. Building width is measured perpendicular to the ridge. For widths between <br />those shown, spans are permitted to be interpolated. <br />d. NJ - Number of jack studs required to support each end. Where the number of <br />required jack studs equals one, the header is permitted to be supported <br />by an approved framing anchor attached to the full -height wall stud and to the <br />header. <br />e. Reserved. <br />24" MIN. LAP <br />`03 OR 04 REINFORCING 5AR <br />3 #4 LAP SPL i CE <br />25" MIN. LAP <br />REINFORCING BAR <br />#5 LAP SPL I CE <br />I�nnvrvr«.nv�.s »�R <br />pro _IV LAP SPL i CE <br />d7" MIiJ I dF <br />n r"11,rVr,V,, %-s "',r, <br />i LAP SPLICE <br />10)" <br />05 REINFORCING BAR <br />A.C.i. STD. 'BOO 150ND <br />' EBAR SPLICING 4 LAP DETAIL, <br />TABLE R602. 7(2) <br />GIRDER SPANSaAND HEADER SPANSa FOR INTERIOR BEARING WALLS <br />(MAXIMUM SPANS FOR DO GLAS FIR -LARCH, HEM -FIR, SOUTHERN PINE <br />AND SPRUCE -PINE -FIR` AND REQUIRED NUMBER OF JACK STUDS) <br />GIRDERS AND HEADERS <br />SUPPORTING <br />SIZE <br />Building widthc (feet) <br />20 <br />28 <br />36 <br />SPAN <br />NJ <br />SPAN <br />NJ <br />SPAN <br />NJ <br />One floor only <br />2-2x4 <br />3-1 <br />1 <br />2-8 <br />1 <br />2-5 <br />1 <br />2-2x6 <br />4-6 <br />1 <br />3-11 <br />1 <br />3-6 <br />1 <br />2-2x8 <br />5-9 <br />1 <br />5-0 <br />2 <br />4-5 <br />2 <br />2-2x10 <br />7-0 <br />2 <br />6-1 <br />1 2 <br />5-5 <br />2 <br />2-2x12 <br />8-1 <br />2 <br />7-0 <br />2 <br />6-3 <br />2 <br />3-2x8 <br />7-2 <br />1 <br />6-3 <br />1 <br />5-7 <br />2 <br />3-2x10 <br />8-9 <br />1 <br />7-7 <br />2 <br />6-9 <br />2 <br />3-2x12 <br />10-2 <br />2 <br />8-10 <br />2 <br />7-10 <br />1 2 <br />4-2x8 <br />9-0 <br />1 <br />7-8 <br />1 <br />6-9 <br />2 <br />4-2x10 <br />10-1 <br />1 <br />8-9 <br />1 <br />7-10 <br />2 <br />4-2x12 <br />11-9 <br />1 <br />10-2 <br />2 <br />9-1 <br />2 <br />Two floors <br />2-2x4 <br />2-2 <br />1 <br />1-10 <br />1 <br />1-7 <br />1 <br />2-2x6 <br />3-2 <br />2 <br />1 2-9 <br />2 <br />2-5 <br />1 2 <br />2-2x8 <br />4-1 <br />2 <br />3-6 <br />2 <br />3-2 <br />2 <br />2-2x10 <br />4-11 <br />2 <br />4-3 <br />2 <br />3-10 <br />3 <br />2-2x12 <br />5-9 <br />2 <br />5-0 <br />3 <br />4-5 <br />3 <br />3-2x8 <br />5-1 <br />2 <br />4-5 <br />2 <br />3-11 <br />2 <br />3-2x10 <br />6-2 <br />2 <br />1 5-4 <br />2 <br />4-10 <br />2 <br />3-2x12 <br />7-2 <br />2 <br />6-3 <br />2 <br />5-7 <br />3 <br />4-2x8 <br />4-2 <br />2 <br />5-3 <br />2 <br />4-8 <br />2 <br />4-2x10 <br />7-2 <br />2 <br />6-2 <br />2 <br />5-6 <br />2 <br />4-2x12 <br />8-4 <br />2 <br />7-2 <br />2 <br />6-5 <br />2 <br />For S1: 1 inch = 25.4 am, 1 foot=304.8mm <br />a. Spans are given in feet and inches. <br />b. Tabulated values assume #2 grade lumber. <br />c. Building width is measured perpendicular to the ridge. For widths between <br />those shown, spans are permitted to be interpolated. <br />d. NJ - Number of jack studs required to support each end. Where the number of <br />required jack studs equals one, the header is permitted to be supported by an <br />approved framing anchor attached to the full -height wall stud and to the <br />header. <br />R502.2.6 Bearing. The ends of each joist, beam or girder shall have not less than 1.5 inches (38 mm) <br />of bearing on wood or metal and not less than 3 inches (76 mm) on masonry or concrete except where <br />supported on a 1-inch-by-4-Inch (25.4 mm by 102 mm) ribbon strip and nailed to the adjacent stud or <br />by the use of approved joist hangers. <br />R502. 2.6. 1 Floor systems [ IRC R502. 6. 1]. Joists framing from opposite sides over a bearing support <br />shall lap a minimum of 3 inches (76 mm) and shall be nailed together with a minimum three 10d face <br />nails. A wood or metal splice with strength equal to or greater than that provided by the nailed lap <br />is permitted. <br />R502.2.6.2 Joist framing [IRC R502.6.2]. Joists framing into the side of a wood girder shall be <br />supported by approved framing anchors or on ledger strips not less than nominal 2 inches by 2 inches <br />(51 mm by 51 mm). <br />R502.2.7 Lateral restraint at supports [IRC R502.7]. Joists shall be supported laterally at the ends <br />by full -depth solid blocking not less than 2 inches (51 mm) nominal in thickness; or by attachment to <br />a full -depth header, band, or rim joist, or to an adjoining stud; or shall be otherwise provided with <br />lateral support to prevent rotation. <br />Exception: Reserved. <br />R502. 2. 7. 1 Bridging [ IRC R502. 7. 1]. Joists exceeding a nominal 2 inches by 12 inches (51 mm by 305 mm) <br />shall be supported laterally by solid blocking, diagonal bridging (wood or metal), or a continuous <br />1-Inch-by-3-inch (25.4 mm by 76 mm) strip noiled across the bottom of joists perpendicular to joists <br />at intervals not exceeding 8 feet (2438 mm). <br />R502.2.8 Drilling and notching [IRC R502.8]. Structural floor members shall not be cut, bored or <br />notched In excess of the limitations specified in this section. See Figure R502.2.8. <br />R502. 2. 8. 1 Sawn lumber[ IRC R502. 8. 1]. Notches in solid lumber joists, rafters and beams shall not <br />exceed one -sixth of the depth of the member, shall not be longer than one-third of the depth of the <br />member and shall not be located in the middle one-third of the span. Notches at the ends of the member <br />shall not exceed one-fourth the depth of the member. The tension side of members 4 inches (102 mm) or <br />greater in nominal thickness shall not be notched except at the ends of the members. The diameter of <br />holes bored or cut into members shall not exceed one-third the depth of the member. Holes shall not be <br />closer than 2 inches (51 mm) to the top or bottom of the member, or to any other hole located in the <br />member. Where the member is also notched, the hole shall not be closer than 2 inches (51 mm) to the <br />notch. <br />R502.2.8.2 Engineered wood products [IRC R502.8.2]. Cuts, notches and holes bored in trusses, <br />structural composite lumber, structural glue -laminated members or I -joists are prohibited except where <br />permitted by the manufacturer's recommendations or where the effects of such alterations are <br />specifically considered in the design of the member by a registered design professional. <br />R502.2.9 Fastening [IRC R502.9]. Floor framing shall be nailed In accordance with Table R602.2(1) <br />Where posts and beam or girder construction is used to support floor framing, positive connections <br />shall be provided to ensure against uplift and lateral displacement. <br />R502.2.10 Framing of openings [IRC R502. 10]. Openings in floor framing shall be framed with a header <br />and trimmer joists. When the header joist span does not exceed 4 feet (1219 mm). the header joist may <br />be a single member the some size as the floor joist. Single trimmer joists may be used to carry a <br />single header joist that is located within 3 feet (914 mm) of the trimmer joist bearing. <br />When the header joist span exceeds 4 feet (1219 mm), the trimmer joists and the header joist shall be <br />doubled and of sufficient cross section to support the floor joists framing into the header. Approved <br />hangers shall be used for the header joist to trimmer joist connections when the header joist span <br />exceeds 6 feet (1829 mm). Tail joists over 12 feet (3658 mm) long shall be supported at the header by <br />framing anchors or on ledger strips not less than 2 inches by 2 inches (51 mm by 51 mm). <br />R502.3 Design and construction where wind speed is 100 mph or greater. Floor framing of light -frame <br />wood construction shall be designed and constructed in accordance with the provisions of Section <br />R301.2. 1.1, Section R502. 1. <br />2,-0" O PILA5TER <br />MAX. <br />• <br />"All 001ON10-010010SWIN01ON100 OO• <br />vERT i GAL RE ii FORCEI" ONTS <br />SCHEDULE MASONR1' TJ <br />8' PLATE HEIGHT = 8'-0" O.G. <br />10' PLATE HEIGHT = 6'-O" O.C. <br />12' PLATE HEIGHT = 4'-0" O.G. <br />"A" 14' PLATE HEIGHT = 2'-0" O.G. MAX. / PILASTERS 0 10'-0" O.G. <br />AT EACH CORNER 4 BOTH SIDES OF DOORS 4 WINDOWS OPENINGS <br />(OVER 5'-0"). BEFORE 4 AFTER SWEARWALL SEGMENTS, 4 <br />(2) BARS 0 EA. SIDE OF OPENING OVER 12'-0" <br />LAP DIST <br />z - <br />0 <br />� IC.M.U. WALL <br />CORNER CONT iN i TY 4 LUALL REINFORCEMENT <br />iENT <br />ROOF SHEATHING FASTENING SCHEDULE aJb c d,s <br />Sd Common (0.131 x 24,2 kxhss) or Ring -Shenk (0.135 X 2-1/2 Inches) <br />(Except lllhere Noted) for Exposure B, Enclosed Sulldkngs, Roof Framing Spaced 24 Inches <br />oz. or Less <br />Roof Fastening Zone <br />Overhang <br />Wind <br />Main <br />Sheathing -to -Gable <br />(saves) <br />Velocity <br />Roof <br />End -Wall Framingg <br />(3-Second <br />Panel <br />1 2 <br />3 2 3 <br />2 3 <br />Gust) <br />Location <br />Fastening Schedule (inches on center) <br />Supported Panel <br />6 6 <br />6 <br />6 6 <br />150 mphf9 <br />end and edges <br />3h <br />Panel field <br />6 4 <br />3 <br />4 3 <br />Supported Panel 6 6 6 6 6 <br />120 mph f9 and and edges 3 <br />Panel field 12 6 4 6 4 <br />Supported Panel 6 6 6 6 6 <br />W mph end and edges 6 <br />Panel field 12 12 6 6 6 <br />a. Specific gravity (G) of lumber and panels shall be 0.42 or greater. <br />b. For Exposure 5 and a 2-Foot overhang. <br />c. For median roof height 35 feet or less. <br />d. Gable wall height of 8 feet or lase from top floor ceiling to roof peak. <br />a. Provide adequate uplift hardware at truss -to -wall corrections. Such <br />corrections are beyond the scope of this publication. <br />f. When wind speed is 110 mph or greater and when median roof height Is between <br />25 and 35 feet, use 8d ring shank nails (0.135 x 2-1/2 inchsslulthin 48 inches of <br />gable and walls. (IRC Table R6023, footnote f) <br />g. When wind speed is 100 mph or greater, block panel edgee perpendicular to <br />gable -end -wall framing members in the first two bays of framing. Blocking shall be <br />spaced a maximum of 4 feet oz. (Wood Frame Construction Manual, Section 3b.5) <br />h 10d ring -shank nails (0.148x 3 Inches). <br />1. Blocking not required. <br />ROOF FASTENING ZONES FOR WIND UPLIFT <br />Zones 1,2 and 3 shown below Indicate areas of this roof that mag have different fastening <br />requirements. <br />GABLE END WALL <br />3 OVEFZ4AW3 --i <br />WALL LINE <br />3 OVERI-TANG <br />X3 OVERHANG "WALL LINE d 3 OVERI {ANCs -/ \ �L LINE 1 GABLE END WALL <br />Distance a-4 ft. in most cases (109t of least building width or 0.4 times building height, <br />whichever is smaller, but not lose than either 4% of least building width or 3 ft.) <br />ROOF D i APHRAI" i NAILING SCHEDULE (GAPLES) <br />COLLAR TIE 1X6 (MIN.) EVERY <br />OTHERRAFTER T-0" OR LONGER <br />BLOCKING BELOW RIDGE <br />2X(o VERTICAL SCAB OR KNEEWALL MID -POINT <br />IN RAFTER W/ RAFTER SPAN LENGTH GREATER <br />THAN 14 FT OR LONGER. <br />CONN W/ 4-imd NAILS AT TOP 4 HURRICANE <br />CLIP 6 BOTTOM. <br />2X& (MIN.) NO. 2 YP <br />VALLEY FRAMING (TYP. SIMPSON LSTA12 <br />�(OR EQUAL) <br />2X8 NO. 2 SPF <br />RIDGE BOARD <br />P�w�■OMOW] 10 92"T <br />25" MIN. LAP <br />F <br />f <br />I <br />I <br />I <br />II (1) 05 DOWEL <br />I IN COMER <br />I I <br />PLYWOOD SHEATHING <br />(4) imd -0 RIDGE <br />BOARD END <br />TRU55ES BELOW SHEATHED PRIOR <br />TO VALLEY FRAMING INSTALLATION <br />OR 6'-O" O.G. TOP CHORD <br />SIMPSON LSTA12 STRAP OR SIMPSON A22 TIE <br />a EA. RAFTER W/ 10-i0d NAILS <br />(TYP.) <br />2X6 CONT. W/BLEEPER, CLIPPED <br />OR 5TRAPPED TO TRU55 BELOW <br />m*lr FRAM iNG mr:T,41 <br />25" MIN. LAP <br />_r =1= = =__ <br />I • I <br />I <br />I(1) 05 DOWEL <br />II IN CORNER <br />FOOTING 4 STE1" iLUALL. REINFORCEMENT <br />TABLE 2304. 10. 1 <br />FASTENING SCHEDULE <br />DESCRIPTION OF BUILDING ELEMENTS <br />NUMBER AND TYPE OF FASTENER <br />SPACING <br />AND LOCATION <br />Roof <br />3-8d common 2 x 0. 131. ; or <br />3-10d box (3' x 0. 128. ); or <br />1. <br />Blocking between ceiling joists, rafters or trusses to top <br />3-3' x 0.131' nails; or <br />Each end, toenail <br />plate or other framing below <br />3-3' 14 gage staples,crown <br />2-8d common S2j" X 0. 131') <br />2-3" x 0.131 nails <br />Each end, toenail <br />Blocking between rafters or truss not at the wall top plate, <br />2-3" 14 gage staples <br />to <br />rafter or truss <br />2-16 d common 3 x 0. 162) <br />3-3" x 0.131" nails <br />End nail <br />3-3" 14 gage staples <br />16d common ( 3j" X 0. 162") 0 6" o. c. <br />3'x 0. 131" nails 0 6" o.c. <br />Face nail <br />Flat blocking to truss and web filler <br />3" 14 gage staples 0 6'o.c. <br />3-8d common S21" X 0. 131")or <br />3-I0d box (3 x 0.128')or <br />Each joist, toenail <br />2. <br />Ceiling joists to top plate <br />3-3" 0.131" nails; or <br />3-3' 14 gage staples, " crown <br />3. <br />Ceiling joist not attached to parallel rafter. <br />3-16d common (2}" X 0.131")or <br />4-I0d box (3" x 0.128")or <br />laps over partitions (no thrust) <br />4-3'x 0.131" nails; or <br />Each and, toenail <br />(see Section 2308.7.3.1. Table 2308.7.3.1) <br />4-3" 14 gage staples, ?a' crown <br />4. <br />Ceiling joist attached to parallel rafter (heel joint) (see <br />per Table 2308.7.3.1 <br />Face nail <br />Section 2308, 7. 3. 1, Table 2308. 7. 3. 1) Per Table 2308. 7. 3. 1 <br />3-IOd common 3 X 0. 148 ; or <br />4-I0d box (3" x 0.128");or <br />5. <br />Collar tie to rafter <br />4-3" 0.131' nails; or <br />Face nail <br />4-3" 14 gage staples, j6' crown <br />3-10d common 3 X 0. 148 ; or <br />4-10d box (3" x 0. 128") ; or <br />6. <br />Rafter or roof truss to top plate <br />4-3" 0.131' nails; or <br />Face nail <br />(See Section 2308.7.5, Table 2308. 7. 5) <br />4-3" 14 gage staples, j' crown <br />2-16d common 3 1/2 X 0. 162 oor <br />3-10d box (3" x 0. 128') ; or <br />3-3' 0.131" nails; or <br />3-3' 14 gage staples, j" crown; or <br />End nail <br />7. <br />Roof rafters to ridge valley or hip rafters; or roof <br />3-10d common 3 1/2" X 0.148');or <br />rafter to 2-inch ridge beam <br />3-16d box (3 1/2" x 0.135");or <br />4-10d box (3"x 0128'); or <br />Toenail <br />4-3"x 0.131" nails; or <br />4-3" 14 a e sto les crown <br />16d common 3 1 2 X 0. 162 <br />24 o. c. face <br />noil <br />lud common ;or <br />3-x 0.131' nails; or <br />I6'o.c. face <br />nail <br />8. Stud to stud (not at braced wall panels) <br />3-3" 14 gage staples, J" crown <br />16d common 3 1/2" X 0.162 ; <br />18'o.c. face <br />nail <br />9. <br />Stud to stud and abutting studs at intersecting wall <br />16d box 3 1/2- X 0.135 ;or <br />12 o.c. face <br />nail <br />3 x 0.131 nails; or <br />12"o.c. face <br />nail <br />corners (at braced wall panels) <br />3-3' 14 gage staples, &' crown <br />10. <br />Built-up header (2" to 2" header)) <br />16d common 3 1 2 X 0.162 <br />16'o.c. face <br />nail <br />16d box 3 1 2 X 0. 135 • or <br />12 o. c. face <br />nail <br />11. <br />Continuous header to stud 4-8d common (21/2. X 0. 131. ); <br />4-8d common 2 1/2- X 0. 131 ;or <br />Toenail <br />4-10d box 3 x 0. 128 <br />16d common 3 1 2 X 0. 162 ; or <br />18 o. c. face <br />nail <br />1 d common . 1 , or <br />12. <br />Top plate to top plate <br />3"x 0.131' nails; or <br />12'o.c. face <br />nail <br />3" 14 gage staples, ?6" crown <br />8-16d common 3 1/2' X 0.162 );or <br />Each side of <br />end joint, face <br />12-I0d box (3' x 0.128");or <br />nail <br />13. <br />Top plate to top plate, at end joints <br />12-3' 0.131" nails; or <br />(minimum 24' <br />lap splice length <br />12-3' 14 gage staples," crown <br />each side of <br />end joint) <br />16d common 3 1 2 X 0. 162 ; or <br />18 o. c. face <br />nail <br />14. <br />Bottom plate to joist, rim joist, band joist or blocking <br />10d box .1 ;or <br />3"x 0.131" nails; or <br />(not at braced wall panels) <br />12'o.c. face <br />nail <br />3" 14 gage staples, ?6' crown <br />2-16d common 3 1/2* X 0.162");or <br />15. <br />Bottom plate to joist, rim joist, band joist or blocking <br />3-16d box (3 1/2" x 0.135");or <br />at <br />braced wall panels <br />4-3" 0.131" nails; or <br />Toenail <br />4-3' 14 gage staples, ?S' crown <br />4-8d common 2 1 2- X 0. 131' : or <br />4-10d box (3" x 0.128`);or <br />Toenail <br />4-3" 0. 131' nails; or <br />4-3' 14 gage staples, &' crown <br />16. <br />Stud to top or bottom plate <br />2-16d common 3 1 Z X 0. 162 ); or <br />3-10d box (3" x 0.128');or <br />3-3' 0.131" nails; or <br />End nail <br />3-3' 14 gage staples, ?g' crown <br />2-16d common 3 1/2* X 0. 162 . or <br />3-10d box (3" x 0. 128");or <br />17. <br />Top or bottom plate to stud <br />3-3" 0.131" nails; or <br />End Hall <br />3-3" 14 gage staples, ?6" crown <br />2-16d common 3 1/2* X 0. 162 ; or <br />3-10d box (3- x 0. 128`) ; or <br />18. <br />Top plates, laps at corners and intersections <br />3-3" 0.131" nails; or <br />Face nail <br />3-3' 14 gage staples, J" crown <br />2-8d common 2 1/2' X 0.131 ; or <br />2-10d box (3" x 0.128");or <br />19. <br />1" brace to each stud and plat <br />2-3" 0.131" nails; or <br />Face nail <br />3-3" 14 gage staples,iV crown <br />2-8d common 2 1/2" X 0. 131 ; or <br />Face noil <br />20. <br />1'x6" sheathing to each bearing <br />3-10d box (3' x 0.128");or <br />21. <br />1"x8" and wider sheathing to each bearing <br />3-8d common 2 1/2* X 0. 131 ; or <br />3-10d box (3" x 0.128");or <br />Face noil <br />Floor <br />3-8d common (2 1/2' X 0. 131"); or <br />3-10d box (3" x 0.128");or <br />22. <br />Joist to sill, topplate, or girder <br />3-3" 0.131" nails; or <br />Toenail <br />3-3" 14 gage staples, &" crown <br />8d common 2 1/2' X 0. 131"); or <br />10d box (3" x 0. 128") ; or <br />23. <br />Rim joist, band joist, or blocking to top plate, sill or <br />3" 0.131" nails; or <br />6"o.c., toenail <br />other framing below <br />3" 14 gage staples, &" crown <br />2-8d common 2 1/2' X 0.131 ;or <br />Face nail <br />24. <br />1"x 6'subfloor or less to each ioist <br />2-10d box (3" x 0.128');or <br />25. <br />2" subfloor to Joist or Irder <br />2-16d common 3 1 2 X 0.182 <br />Face nail <br />26. <br />2" planks lank & beam - floor & roof <br />2-16d common 3 1/2" X 0& 162 <br />Each bearing, <br />face moil <br />32" o.c., face nail at top and <br />20d common (4"x 0.192") <br />bottom <br />staggered on <br />opposite sides) <br />10d common );or <br />24" o. c. , face no 1 at top and <br />27. <br />Built-up girders and beams, 2, lumber layers <br />3'x 0.131' nails; or <br />bottom <br />3" 14 gage staples, &' crown <br />staggered on <br />opposite sides) <br />2-20d common 4 X 0. 192 , or <br />3-I0d box (3' x 0.128");or <br />Ends and at each splice, face <br />3-3" 0. 131" nulls; or <br />nail <br />3-3" 14 gage staples, &" crown <br />3-16d common 3 1/2' X 0. 162 ; or <br />4-I0d box (3" x 0.128');or <br />Each joist or rafter, face nail <br />28. <br />Ledger strip supporting joists or rafters <br />4-3" 0.131- nails; or <br />4-3' 14 gage staples,&" crown <br />3-16d common 3 1/2' X 0. 162 ; or <br />4-I0d box (3" x 0.128');or <br />End nail <br />29. <br />Joist to band joist or rim joist <br />4-3" 0.131' nails; or <br />4-3" 14 gage staples, J" crown <br />3-16d common 3 1/2' X 0. 162 ; or <br />4-10d box (3" x 0.128");or <br />End nail <br />30. <br />Bridging or blocking to joist, rafter or truss <br />4-3' 0.131" nails; or <br />4-3" 14 gage staples, &" crown <br />Wood structural panels (WSP), subfloor, roof and Interior wall <br />sheathing to framing and particleboard wall sheathing to <br />framing <br />a <br />Edges <br />Intermediate <br />(inches) <br />supports <br />(inches) <br />8d common or deformed (2' x 0.113") <br />6 <br />12 <br />subfloor and wall <br />8d box or deformed (2 1/2'x 0.113') <br />6 <br />12 <br />roof <br />21'xO.113' nail (subfloor and wall) <br />6 <br />12 <br />"- <br />31. <br />3/8 1/2" <br />117 16 gage staple, ?$" crown <br />4 <br />8 <br />subfloor and wall <br />21" x 0.113, nail (roof) <br />4 <br />8 <br />1 3/4"16 gage staple,J"crown(roof) <br />3 <br />5 <br />8d common (2 1/2"x 0.131'); or <br />6 <br />12 <br />6d deformed 2"xO.113" <br />32. <br />19/32 ' - 3/4" <br />113a <br />2� x0. , nail; <br />12 <br />2 16 e eta leor 7 16 crown <br />16 <br />10d common (3" x 0. 148" ); or <br />6 <br />12 <br />33. <br />78 - 1` <br />8d deformed (2rx 0. 131") <br />Other exterior wall sheathing <br />11' galvanized roofing nail <br />(?6" head diameter);or <br />34. <br />1/2 "fiberboard sheathing b <br />11'. 18 gage staple with J"or 1" <br />3 <br />6 <br />crown <br />2-20d common 4 X 0. 192 ; or <br />35. <br />25/32. fiberboard sheathing b <br />3-I0d box (3' x 0.128");or <br />3 <br />6 <br />3-3" 0.131" nails; or <br />3-3" 14 gage staples, ?G" crown <br />Wood structural panels, combination subfloor underlayment to framing <br />8d common (2 1/2"x 0.131"); or <br />6 <br />12 <br />36, <br />4 " and less <br />6d deformed 2'xO.113' <br />'- <br />8d common (2 1/2"x 0.131'); or <br />6 <br />12 <br />37. <br />7/8 1' <br />6d deformed 2"xO.113' <br />38. <br />l j' 11" <br />10d common (3" x 0. 148') • or <br />6 <br />12 <br />8d deformed 2 1 2"xO.131" <br />Panel siding to framing <br />6d corrosion -resistant siding <br />( 11" X 0. 106") ; or <br />39. <br />1/2. or less <br />6d corrosion -resistant casing (2"X <br />6 <br />12 <br />0.099") <br />8d corrosion -resistant siding <br />40. <br />5/8' <br />(2 3/8' X 0. 128"); or <br />8d corrosion -resistant casing <br />6 <br />12 <br />(2 1/2-X 0. 113-) <br />Interior paneling <br />4d common (I 1/2"x 0.080"); or <br />8 <br />12 <br />41. <br />1" <br />4d finish 1 1/2" x 0.072" <br />42. <br />6d casing (2"x 0.099"); or <br />6 <br />12 <br />6d finish Panel supports at 24" <br />For S1: 1 inch - 25.4 mn. <br />a. Nails spaced at 6 inches at Intermediate supports where spans are 48 inches or more. For nulling of wood structural panel and <br />particleboard diaphragms and shear walls, refer to Section 2305. Nails for wall sheathing are permitted to be common, box or casing. <br />b. Spacing shall be 6 inches on center on the edges and 12 inches on center at Intermediate supports for nonstructural applications. <br />Panel supports at 16 Inches (20 inches if strength axis in the long direction of the panel, unless otherwise marked). <br />c. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule and the calling joist is <br />fastened to the top plate in accordance with this schedule, the number of toenails in the rafter shall be permitted to be reduced by <br />one nail. <br />r <br />a <br />O <br />L <br />0 <br />C <br />Q1 <br />0 <br />a) <br />0 <br />0) <br />C <br />O <br />>r <br />N <br />C <br />L <br />O <br />0 <br />00 <br />0 <br />04 <br />h- <br />2 <br />(D <br />o <br />C) <br />