SCOPE OF WORK: <br />TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC <br />SYSTEM AT THE OWNER COMMERCIAL BUILDING LOCATED AT <br />6911 GALL BLVD., ZEPHYRHILLS, FL 33542, USA. <br />THE POWER GENERATED BY THE PV SYSTEM WILL BE <br />INTERCONNECTED WITH THE UTILITY GRID THROUGH THE <br />EXISTING ELECTRICAL SERVICE EQUIPMENT. <br />THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES <br />SYSTEM SUMMARY <br />96 MISSION SOLAR MSE395SX9R (395W) MODULES <br />96 ENPHASE IQ8H-3P-72-E-US MICROINVERTERS <br />PROJECT DESCRIPTION: <br />96 X 395 MISSION SOLAR MSE395SX9R (395W) MODULES <br />ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES <br />SYSTEM SIZE: 36.48 kW AC STC <br />SYSTEM SIZE:37.92 kW DC STC <br />ARRAY AREA: ROOF#1 - 1038.24 SQ FT <br />ARRAY AREA: ROOF#2 - 1038.24 SQ FT <br />AUTHORITIES HAVING JURISDICTION <br />BUILDING : HILLSBOROUGH COUNTY <br />ZONING : HILLSBOROUGH COUNTY <br />UTILITY : N/A <br />GENERAL NOTES: <br />• THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND <br />OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE <br />MODIFICATIONS IN CONSTRUCTION DETAILS. <br />• ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR <br />INSTALLATION OF ANY EQUIPMENT AT SITE. <br />• CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL <br />PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. <br />• CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS <br />AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER <br />BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION <br />AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE <br />CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL <br />COMPENSATION. <br />• DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, <br />FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE <br />CONTRACTOR AT NO ADDITIONAL COST. <br />• THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND <br />COMPLETION OF THE WORK WITH APPROVED MATERIALS. <br />• NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE <br />ARCHITECT. <br />• CONTRACTOR SHALL OBTAIN BUILDING PERMIT. NO WORK TO START UNLESS BUILDING <br />PERMIT IS PROPERLY DISPLAYED. <br />• ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE <br />WITH THE REQUIREMENTS OF THE FL BUILDING CODE, THE DEPARTMENT OF <br />ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. <br />• IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL <br />PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. <br />THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. <br />• ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO <br />BE PAINTED BY GENERAL CONTRACTOR. <br />• THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE <br />LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. <br />• THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, <br />CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. <br />• CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. <br />APPLICABLE CODES & STANDARDS: <br />2023 FLORIDA BUILDING CODE: BUILDING <br />2023 FLORIDA BUILDING CODE: RESIDENTIAL <br />2023 FLORIDA BUILDING CODE: EXISTING BUILDING <br />2020 NATIONAL ELECTRICAL CODE (NEC) <br />DESIGN CRITERIA <br />WIND SPEED <br />138 MPH VULT <br />EXPOSURE CATEGORY <br />C <br />RISK CATEGORY <br />II <br />MOUNTING METHOD <br />ROOF MOUNT <br />GROUND SNOW LOAD <br />3 PSF <br />WIRING AND CONDUIT NOTES: <br />• ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS <br />PURPOSE AND APPROVED FOR THE SITE APPLICATIONS <br />• ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV <br />WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY M FR, <br />OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER <br />BOXES AS REQUIRED <br />• ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED <br />ACCORDING TO [NEC 690.8 (A)(1) & (13)(1)], [NEC 240] [NEC <br />690.7] FOR MULTIPLE CONDUCTORS <br />• ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT <br />SHALL BE DERATED ACCORDING TO [NEC TABLE 310.15 <br />(13)(2)(C)] BLACK ONLY** <br />• EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 900C <br />RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR <br />60OV, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT <br />WIRE FROM SHARP EDGES <br />• 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH <br />THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR <br />IDENTIFIED BY OTHER EFFECTIVE MEANS <br />• ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE <br />CIRCUIT PROTECTION <br />• VOLTAGE DROP LIMITED TO 2% <br />• AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE <br />A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, <br />NEUTRAL- WHITE/GRAY <br />ELECTRICAL NOTES: <br />• THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS <br />ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS <br />AND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(C), NEC 2020) <br />• LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP <br />CONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. <br />• NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE <br />COORDINATION REQUIREMENTS OF OTHER TRADES. <br />• ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. <br />• ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (NEC 690), NEC 2020. <br />• WIRING METHODS FOR PV SYSTEM CONDUCTORS AREN'T PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED <br />DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING <br />• BACK -FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. <br />• ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. <br />• CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN NEC 690 <br />• PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONNECTION, AND SPLICES. THE MEANS OF ID <br />CAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. (NEC 690.4), NEC 2020. <br />• MEASURE THE LINE -TO -LINE AND LINE -TO -NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY SOLAR <br />EQUIPMENT. THE VOLTAGES FOR THE 208VAC RATED. <br />N <br />s <br />0 <br />SHEET INDEX <br />PV-0 <br />PV-1 <br />PV-2 <br />PV-2A <br />PV-3 <br />PV-4 <br />PV-5 <br />PV-6 <br />PV-7 <br />to 13 <br />COVER SHEET <br />PLOT PLAN <br />ROOF PLAN & MODULES <br />BRANCH LAYOUT <br />ATTACHMENT DETAIL <br />ELECTRICAL LINE DIAGRAM <br />WIRING CALCULATIONS <br />WARNING LABELS & PLACARD <br />EQUIPMENT SPECIFICATIONS <br />1 I COMMERCIAL BUILDING PHOTO <br />PV-0 <br />SCALE: NTS <br />PROJECT SITE <br />'g8 <br />Richland <br />6911 GALL BLVD., <br />ZEPHYRMILLS, FL 33542 <br />.000waft, (54) <br />Zephyrhills LIJ)PHillsbor� <br />Zephyrhills <br />So�tti <br />2 I VICINITY MAP <br />PV-0 <br />Wildli <br />SCALE: NTS <br />TAM PA BAY <br />Lj <br />of,""4 rx <br />POWERING THE SUNSHINE STATE <br />6002 E. ADAMO DR., TAMPA, <br />FL,33619 <br />PH. NO.: (813) 398-3687 <br />Email : info@tampabaysolar.com <br />REVISIONS <br />DESCRIPTION <br />DATE <br />REV <br />ELECTRICAL <br />01/15/2024 <br />#1 <br />CHANCES <br />SETBACK <br />01/17/2024 <br />#2 <br />GIVEN <br />CHANGED <br />INVFRTFR TYPE <br />02/13/2024 <br />#3 <br />CALCULATION <br />ADDED <br />02/15/2024 <br />#4 <br />SIGNATURE WITH SEAL <br />DATE: 02/15/2024 <br />PROJECT NAME &ADDRESS <br />V <br />Z <br />N <br />0 <br />� <br />J <br />_ <br />�CY) <br />Q <br />M <br />Q <br />m <br />CO� <br />J <br />J <br />J <br />J <br />�_ <br />_j <br />w <br />V <br />Q <br />w <br />�� <br />� <br />w <br />N <br />0 <br />SHEET NAME <br />COVER SHEET <br />SHEET SIZE <br />ANSI B <br />11 " X 17" <br />SHEET NUMBER <br />PV-0 <br />