My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (102)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (102)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:54:01 AM
Creation date
2/18/2025 3:47:08 PM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
AP C Electrical
Building Plans - Permit #
19380
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FLUSH MOUNTED IN SLAB <br />TRENCH DUCT- TURN UP AT <br />NEW EQUIPMENT PER —� <br />MANUFACTURES <br />RECOMMENDATIONS AND <br />DETAILS <br />ALL 90 DEGREE <br />TURNS TO BE <br />CHAMFERED TO 45S <br />DIVIDE INTO 3- <br />EQUAL <br />COMPARTMENTS <br />PROVIDE FLUSH <br />MOUNTED WATER <br />PROOF COVER OVER <br />TOP SURFACE OF <br />DUCT- ALIGN WITH <br />FINAL FLOOR FINISH <br />WHERE APPROVED BY OWNER AND ENGINEER SAW CUT EXISTING <br />SURFACE MOUNTED WIRE DUCT MAY BE SLAB TO INSTALL <br />SUBSTITUTED WITH FOR IN SLAB NEW TRENCH DUCT <br />INSTALLATION- LEGRAND OR EQUAL EXTENSION <br />FLOOR DUCT EXTENSION DETAIL <br />4 <br />DEMOLITION NOTES <br />GENERAL NOTES <br />I. PROVIDE A FULL TIME PERSON IN CHARGE OF MAINTAINING A CLEAN WORK AREA AND <br />WHOSE RESPONSIBILITIES SHALL INCLUDE THE FOLLOWING: <br />1. <br />CONTRACTOR IS RESPONSIBLE FOR REPAIR OF ALL EXISTING HOLES AND UNSEALED <br />PENETRATIONS IN EXISTING RATED PARTITIONS WHICH ARE INCLUDED IN THIS <br />MAINTENANCE OF NEGATIVE PRESSURE MACHINES IN THE WORK AREAS INCLUDING <br />PROJECT. REFER TO NEW WORK FLOOR PLANS FOR LOCATION. INSPECT PARTITIONS <br />PROPER OPERATION AND LOCATION, PROPER VENTING TO NON -OCCUPIED AREAS. <br />PRIOR TO BIDDING. <br />MAINTAIN A CLEAN AND DUST -FREE AREA. <br />2. <br />REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION AND ELECTRICAL DRAWINGS <br />FOR WORK OF OTHER TRADES NOT INDICATED ON ARCHITECTURAL DEMOLITION <br />MONITOR AND RECORD NEGATIVE PRESSURE READINGS FROM MANOMETERS. READINGS <br />DRAWINGS. <br />SHALL BE TAKEN EVERY TWO HOURS AND AT THE BEGINNING AND END OF EACH WORK <br />DAY. <br />3. <br />WHERE IT IS NECESSARY TO REMOVE EXISTING CEILINGS TO INSTALL NEW ABOVE CEILING <br />PIPING OR DUCTWORK, REPLACE EXISTING CEILING PANELS WITH NEW PANELS TO MATCH <br />t. PROVIDE MANOMETERS TO MONITOR NEGATIVE AIR PRESSURE IN WORK AREAS. LOCATE <br />EXISTING. REFER TO 'M'/'P'/'FP'/'MG' AND 'E' DRAWINGS FOR LOCATIONS. <br />AS DIERECTED BY ARCHITECT. <br />4. <br />REFER TO PHASING PLANS FOR PHASING REQUIREMENTS. <br />S. PRIOR TO COMMENCEMENT OF WORK, INSPECT WORK AREAS FOR WET <br />DRYWALL AND THE PRESENCE OF MOLD OR MILDEW OR OTHER HAZARDOUS MATERIAL. <br />5. <br />CONTRACTOR IS RESPONSIBLE FOR ALL EXISTING PARTITION, FLOOR, AND ROOF <br />REPORT FINDINGS TO ARCHTECT AND OWNER FOR DIRECTIONS ON REMOVAL PROCEDURES. <br />DEMOLITION NECESSARY FOR INSTALLATION OF NEW DUCTWORK, PIPING AND ROOF <br />EQUIPMENT. REFER TO 'M'/'P'/'FP'/'MG' AND 'E' DRAWINGS FOR LOCATIONS. <br />I•. PROVIDE ADHESIVE SURFACED WALK -OFF MATTS AT THE EACH ENTRANCE TO A WORK <br />AREA. <br />6. <br />WHERE EXISTING DUCTWORK OR PIPING IS REMOVED, PATCH OPENINGS REMAINING <br />IN EXISTING PARTITIONS TO MATCH EXISTING CONSTRUCTION AND RATING. REFER TO <br />i. WORK SHALL BE PERFORMED ON SCHEDULE CONVENIENT TO THE OWNER. <br />'M'/'P'/'FP'/'MG' AND 'E' DRAWINGS FOR LOCATIONS. <br />WORK INVOLVING EXCESSIVE VIBRATION, NOISE OR OTHERWISE INTERFERING WITH <br />EMERGENCY DEPARTMENT FUNCTIONS SHALL BE PERFORMED AT NIGHT OR AT <br />OTHER TIMES NOT INTERFERING WITH THE OWNER'S CONTINUING OPERATIONS. <br />3. AREAS ADJACENT TO THE PROJECT AREA SHALL BE OCCUPIED BY THE OWNER <br />DURING CONSTRUCTION. CONSTRUCT WORK SO THAT OWNER'S <br />CONTINUING OPERATIONS CAN BE MAINTAINED. ALL WORK AFFECTING PATIENT <br />OCCUPIED AREAS SHALL BE PERFORMED AT A TIME CONVENIENT TO THE OWNER. <br />MAINTAIN EMERGENCY EGRESS AND PUBLIC ACCESS TO ALL PATIENT AREAS DURING <br />EACH PORTION OF THE WORK. <br />1. PROVIDE DUST PARTITIONS BETWEEN CONSTRUCTION AREAS <br />AND OCCUPIED AREAS IN LOCATIONS INDICATED AND IN OTHER LOCATIONS <br />AS THE NEED MAY ARISE. <br />• " ZDFGDF 8. MAINTAIN NEGATIVE PRESSURE IN CONSTRUCTION AREAS DURING CONSTRUCTION. <br />------------------ <br />LOCATE, MAINTAIN AND PROVIDE TEMPORARY POWER FOR OWNER FURNISHED <br />NEGATIVE PRESSURE MACHINES. <br />SAW CUT EXISTING SLAB TO 9• REQUIRED WORK WHICH IS LOCATED OUTSIDE OF THE GENERAL CONSTRUCTION <br />LIMITS AND IN OCCUPIED AREAS SHALL BE ACCOMPLISHED SO AS NOT TO <br />INSTALL NEW TRENCH DUCT INTERFERE WITH THE OWNER'S OPERATIONS. <br />EXTENSION <br />2ND FLOOR STRUCTURE ABOVE --- -- -._ _ <br />I I I <br />SUSPENDED CEILING TO BE PROTECTED- <br />I I <br />REPLACED AS REQUIRED <br />Q � 1 <br />i <br />' �� FROSTED GLASS UPPER <br />- - -'- -'- ,--;7 CABINET FACES <br />S MILLWORK DETAILS TILED BACKSPLASH AT <br />ON SHEET A401 NEW CABINETRY <br />SOLID SURFACE COUNTERTOPS <br />0 0 <br />PREMIUM LAMINATE CABINETS <br />ON PLYWOOD SUBSTRATE <br />6" DIMENSIONAL VINYL BASE <br />NEW VINYL PLANY FLOORING <br />WALL <br />CONTRACTOR TO COORDINATE <br />INSTALLATION OF M ISCELLANIOUS <br />EQUIPMENT CONDUIT FROM <br />CONTROL RM EQUIPMENT TO <br />OVERHEAD EQUIPMENT. <br />VARIES <br />FIRE RETARDANT 2X CKING <br />AT MONITOR ARM ANY_\ <br />WALL MOUNTED EQLN ENT - <br />ACCESSORIES <br />I <br />I <br />I � <br />I I <br />I <br />I N <br />I <br />L, <br />I <br />INTEGRAL BASE INSTALLED <br />AFTER MILLWORK BASE <br />CABINET- FULLY ADHERE <br />TO TOE KICK <br />CONTROL ROOM DESKTOP <br />ICT ROOM-2 <br />PROTECT MURAL WALLS AT <br />CT ROOM LOCATIONS <br />FULL OVERLAY FULL OVERLAY _ <br />CABINET DOOR CABINET DOOR <br />DESIGN- 2 DESIGN- 2 <br />CONCEALED HINGES CONCEALED HINGES <br />PER DOOR PER DOOR <br />ADJUSTABLE <br />SOUD SURFACE SHELVES SOLID SURFACE <br />DOOR FACES- DOOR FACES - <br />TEMP GLASS io TEMP GLASS <br />WHERE SHOWN IN i I WHERE ELEVATIONS <br />IN <br />ELEVATIONS <br />S.S. PULLS AND S.S. PULLS ANC <br />HARDWARE HARDWARE <br />2'-0" <br />SOUR SURFACE co <br />COUNTERTOPSdc <br />\, S.S. UNDER \ <br />MOUNT SINK <br />s a <br />_O O <br />%'PLYWDOD I I per <br />CONSTRUCIIONAT iv N <br />UNEXPOSED <br />SURFACES <br />tp tD <br />CONTRACTOR TO PROVIDE <br />SHOPDRAWINGS FOR OWNER <br />AND ARCHITECT REVIEW PRIOR <br />TO FABRICATION. <br />CT ROOM-2 DRAWER SECT'N <br />CAB SECT'N W/ SINK CAB SECT'N <br />ADJUSTABLE <br />SHELVES <br />co <br />I <br />s <br />O <br />i <br />CV <br />ROOM FINISH SCHEDULE <br />RM NO <br />ROOM NAME <br />FLOOR <br />WALLS <br />BASE <br />CEILING <br />MATL <br />NOTES <br />N <br />S <br />E <br />W <br />MATL <br />HEIGHT <br />HEIGHT <br />101 <br />R-CONTROL ROOM <br />NEW-SVS <br />GB <br />GB <br />GB <br />GB <br />LVB <br />6 <br />22S <br />1 8 -0 <br />102 <br />R-CT ROOM-2 <br />NEW-SVS <br />MURAL <br />MURAL <br />MURAL <br />MURAL <br />LVB <br />6 <br />22S <br />I 8 -0 <br />103 <br />1 R-EQUIPMENT STORAGE <br />GB <br />GB <br />STUCCOI <br />GB <br />i LVB <br />6 <br />22S <br />1 8 -0 <br />ALL CEILING GRID PANELS WITHIN ADJACENT AREAS TO BE REPLACED WITH ARMSTRONG FINE FISSURE TO MATCH EXISTING <br />NEW FOORING TO MATCH VINYL PLANK MATERIAL AND COLOR INSTALLED THROUGHOUT THE RADIOLOGY DEPARTMENT- VERIFY <br />MANUFACTURE AND COLOR W/ OWNERS SPECIFICATIONS <br />I <br />■ <br />■ <br />■ <br />■ <br />■ <br />SAW CUT SLAB FOR SANITARY ■ <br />LINE CONNECTIONS- PA ICH i <br />SAW CUT AND REPAIR EXISTING <br />FLOOR FINISHES AS REQUIRED TO <br />INSTALL NEW SANITARY LINES TO <br />NEW SINK. SEE PLUMBING PLANS <br />FOR EXACT ROUTING AND EXISTING <br />SANITARY LINE LOCATIONS UNDER <br />SLAB. <br />VERTICAL STORAGE UNIT IN THIS <br />LOCATION TO BE RELOCATED TO CT <br />ROOM-1. CCORDINATE LOCATION - <br />NTH OWNER <br />ALL EXISTING WALLS ARE <br />LEAD LINED CONSTRUCTION. <br />ANY MODIFICATION SHALL <br />BE REPAIRED TO MATCH <br />ORIGINAL DESIGN / <br />SPECIFICATIONS. / <br />Q LEGRAND SURFACE MOUNTED WIRE DUCT SUBSTITUTIONS IN <br />EXISTING MILLWORK TO BE LEIU OF IN SLAB IS ACCEPTABLE IF APPROVED BY OWNER <br />REMOVED AND DISCARDED- PATCH AND ELECTRICAL ENGINEER PRIOR TO CONSTRUCTION. PAINT <br />REPAIR WALLS BEYOND AS A CONTRASTING COLOR TO FLOOR FINISH FOR VISUAL <br />REQUIRED. IDENTIFICATION. <br />- ---- <br />e n� ALL NON -FIXED EQUIPMENT TO B <br />REMOVED AND COORDINATE <br />STORAGE OR DISCARD WITH <br />OWNER PRIOR TO CONSTRUCTION <br />NEW CONTROL ROOM <br />FLOOR DUCT EXTENSION TO ACCOMODATE DESK TO BE <br />1'L10" NEW EQUIPMENT LOCATION- SAW CUT AND PROVIDED -OWNER TO <br />POUR IN PLACE CONCRETE FORM. COORDINATE WITH <br />I I <br />_ EQUIPMENT SUPPLIER. <br />i_--------... <br />N <br />EXISTING CT EQUIPMENT TO BE <br />REMOVED BY EQUIPMENT VENDOR 1 <br />tF <br />PRIOR TO CONSTRUCTION WITHIN 1THIS ROOM. ` ®� <br />I I I <br />I I I <br />._AI <br />L-- - -- -------- <br />F_ I <br />n I I <br />VERTICAL STORAGE UNIT IN THI -- <br />LOCATION TO BE RELOCATED T <br />CT ROOM-1. CCORDINATF L_ _ <br />F'. <br />BL nL.MV TL.v— r nu <br />FLOOR FOR NEW VINYL <br />PLANK FLOORING <br />DEMOLITION- PLAN <br />SCALE 1l4"=1'-0' <br />Lfl:l� -4 [r, <br />AR�.A OF W W <br />............................................................................................................................................,� CONSTRUCTION <br />urw uu w�rw w / <br />AND REPAIR CONC SLAB- NEW ■ <br />FLOOR FINISH AS REQUIRED i FLOOR DUCT EXTE <br />■ <br />■ <br />■ <br />■ <br />■ <br />■ <br />■ <br />■ <br />EXISTING- TIE INT <br />PARTITION COMPAf <br />X. DUCT CHASE IN FL <br />XTEND WITHIN SLAB 0 <br />OUNTED ON FLOOR SI <br />OCATION AS SHOWN. <br />e{` <br />EQUIP. ROOM <br />M <br />I <br />I <br />� <br />ENLARGE CT ROOM PLAN- FIRST FLOOR LEVEL <br />SCALE 1l4"=1'-0" <br />NO. DESCRIPTION DATE <br />0 PER OWNER/ CONTR 12-01-17 <br />O <br />M <br />Q� <br />�-1 <br />Op0 <br />O <br />M � <br />41 <br />;..4 <br />OO'' <br />r-1 <br />�1 W <br />p'�.., <br />[� <br />p p <br />» <br />o <br />O <br />M <br />� <br />N <br />14 <br />.014 <br />cid <br />O <br />W <br />� <br />,� <br />� <br />O <br />O <br />0 <br />� <br />rrE..11� <br />Fi <br />W <br />J_ <br />� <br />0� <br />U <br />d <br />J� <br />LLI <br />_j <br />w <br />F-- <br />� <br />Z <br />z <br />0 <br />J <br />x <br />W <br />U <br />it <br />ula <br />¢ <br />W <br />O <br />x <br />ri <br />W <br />C" v� <br />SEAL <br />0o0 0 <br />e4e,' <br />!_HLING g <br />Oeee AR0091800 we�� <br />v a $ti�y�`0 ! <br />GREGORY T WEHLING, AIA <br />AR 0091800 <br />SHEET TITLE: <br />Enlarged CT <br />Room -Floor Plan <br />DATE: 10/25/17 <br />SCALE: AS SHOWN <br />SHEET NO.: <br />A-1 ■ 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.