My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Ripple Pond Rd
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Ripple Pond Rd
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 11:47:13 AM
Creation date
2/18/2025 3:47:21 PM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Ripple Pond Rd
Contractor
Lennar Homes LLC
Building Plans - Permit #
4918
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WALL LEGEND I <br />8'-8" TOP OF MASONRY WALL <br />(GARAGE) <br />9'-4" TOP OF MASONRY WALL <br />18'-8" TOP OF MASONRY WALL <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-9'-4" TOP OF MASONRY WALL <br />(LANAI) , W/ SHAFT LINER ABOVE TO <br />BOTTOM SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-18'-8" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />-2HOUR FIRE RATED SEPARATION <br />WALL <br />-20'-0" TOP OF MASONRY WALL, W/ <br />SHAFT LINER ABOVE TO BOTTOM <br />SIDE OF DECKING <br />TYP. INTERIOR WALL <br />BEARING WALL <br />I <br />I <br />I <br />L_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ <br />(1666) <br />SYMMETRICAL <br />SYMMETRICAL <br />I <br />I <br />_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J <br />(1666) <br />2nd FLR ELECTRICAL PLAN <br />SCALE: Y4"=1'-0" <br />Riser Diagram <br />6 UNIT BUILDING <br />2/0 CU GEC <br />CONNECTED <br />TO LIFER AND <br />(2) RODS <br />450 AMP <br />SERVICE <br />00 <br />150 AMP <br />0 <br />150 AMP <br />150 AMP <br />(2) Y SCH 80 PVC CONDUITS <br />WITH (2) 500 MCM XHHW AL <br />AND (1) 350 MCM XHHW AL <br />EACH CONDUIT <br />(3) METERS PER BANK <br />(2) METER BANKS PER <br />6-UNIT BLDG. <br />(ONE ON EA. SIDE) <br />(1) 1 J" SCH 80 PVC CONDUIT <br />WITH (2) 210 XHHW AL <br />(1) #1 XHHW AL <br />(1) #4 XHHW AL <br />TYPICAL ALL UNITS <br />NOTE: <br />• ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH <br />APPLICABLE PROVISIONS OF THE NFPA 70 - 17, LOCAL CODES AND <br />THE LOCAL POWER CO. <br />• INSTALL 2" CONDUIT TO METER CAN <br />• INSTALL A MAIN 150 AMP BREAKER IN PANEL <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I-® <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />j3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />�R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />L.0 <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />�P <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G7J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />N _ O <br />O <br />t ' <br />co <br />cr) <br />a <br />v d) <br />N � Q <br />j Q. -0 <br />0 0 <br />-' r3 <br />0 LU <br />CV <br />CV <br />0 <br />N <br />rO <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />E <br />Q O CC, U <br />0 �nm�' <br />� 0 <br />Q N c V LL <br />= J LL <br />LL <br />a <br />_ <br />0 _j w <br />Z ca o <br />To c °' <br />ACV (O 0 <br />W 020)i, = <br />to <br />"Z <LL K <br />Z N OU U W <br />❑ ❑ <br />WQD <br />z N <br />z � <br />0 Q <br />Q <br />J <br />LL <br />aXV O <br />� <br />� <br />U <br />O w o <br />V) L <br />� <br />(a U) <br />U <br />~ E <br />U o N <br />cU)0 <br />101 <br />e <br />E <br />ao <br />Za <br />O-00�� <br />a <br />00UOUC <br />OZiW <br />180 <br />oro <br />Z <br />< <br />wOFw <br />m¢ <br />< <br />W <br />Z Z <br /><0 <br />w <br />Z< <br />3 <br />c <br />°r <br />O <br />'M <br />O <br />T <br />LL <br />ra <br />Q <br />I- <br />0� <br />00 <br />L <br />CO rN <br />/`\iJ0 <br />o <br />III <br />=3 O <br />Q <br />CEO <br />V J om <br />0 <br />cfl <br />Q <br />4-J <br />N <br />2 <br />O CN <br />L0 <br />� <br />� N <br />Q <br />LO <br />(� <br />E <br />c ' LO <br />N <br />Z <br />M <br />Z <br />E r' <br />M <br />a- <br />E _ <br />U _j Q 0 <br />c <br />JOB <br />NO: 22-05604-05601 <br />SCALE : AS NOTED <br />SHEET NO. <br />15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.