AN E RA BAKERY
<br />Proj. Mgr.
<br />DMF
<br />Job. Capt.
<br />DMF
<br />Drawn by
<br />PROJECT INFORMATION
<br />DRAWING INDEX
<br />GN GENERAL INFORMATION
<br />SP-1.1 SITE PLAN
<br />SP-1.2 DUMPSTER & SITE PLAN DETAILS
<br />SP-1.3 DUMPSTER ENCLOSURE DETAILS
<br />SP-1.4 ENLARGED PATIO PLAN & DETAILS
<br />SP-1.5 ENLARGED DRIVE-THRU SIGNAGE DETAILS
<br />SP-1.6 ENLARGED DRIVE-THRU SIGNAGE DETAILS
<br />E-1 ELECTRICAL SITE PLAN
<br />E-2 PROPOSED RISER DIAGRAM
<br />P-1 PLUMBING FLOOR PLAN
<br />P-2 WATER AND GAS ISOMETRIC
<br />FP-1 FIRE SPRINKLERS FLOOR PLAN
<br />FP-2 FIRE SPRINKLERS DETAILS
<br />CAFE #1693
<br />7242 GALL BLVD.
<br />ZEPHYRHILLS, FL 33541
<br />PROJECT DATA
<br />SCOPE OF WORK:
<br />ADDRESS:
<br />LAND LORD IMPROVEMENT
<br />FOR PANERA BREAD
<br />CAFE #1693
<br />7242 GALL BLVD.
<br />ZEPHYRHILLS, FL 33541
<br />APPLICABLE CODES
<br />A. 2010 FLORIDA BUILDING CODE
<br />B. 2009 BROWARD COUNTY AMENDMENTS TO FFPC
<br />C. 2010 FLORIDA PLUMBING CODE
<br />D. 2010 FLORIDA MECHANICAL CODE
<br />E. 2010 TEST PROTOCOLS FOR HIGH VELOCITY HURRICANE ZONES
<br />F. 2011 NFPA 70 NATIONAL ELECTRIC CODE
<br />G. FLORIDA STATE ENERGY CODE
<br />H. 2012 FLORIDA STATE ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION
<br />I. 2012 NFPA 101 LIFE SAFETY CODE AND ADOPTED STANDARDS
<br />J. 2012 NFPA 1 NATIONAL FIRE PREVENTION CODE ( UNIFORM FIRE CODE)
<br />K. 2012 NFPA 220 STANDARD ON TYPES OF BUILDING CONSTRUCTION
<br />ABBREVIATIONS
<br />AB
<br />ANCHOR BOLT
<br />GL
<br />GLASS
<br />PNL
<br />PANEL
<br />A/C
<br />AIR CONDITIONING
<br />GR
<br />GRADE
<br />PNT
<br />PAINT
<br />AFF
<br />ABOVE FINISH FLOOR
<br />GYP
<br />GYPSUM
<br />POL
<br />POLISHED
<br />ALUM
<br />ALUMINUM
<br />HB
<br />HOSE BIBB
<br />PREFAB
<br />PREFABRICATED
<br />APPROX APPROXIMATE
<br />HCP
<br />HANDICAP
<br />PROJ
<br />PROJECT
<br />ARCH
<br />ARCHITECTURAL
<br />HDW
<br />HARDWARE
<br />PSF
<br />POUNDS PER SQ. FOOT
<br />BD
<br />BOARD
<br />HGT
<br />HEIGHT
<br />PSI
<br />POUNDS PER SQ. INCH
<br />BLDG
<br />BUILDING
<br />HIM
<br />HOLLOW METAL
<br />PRTR
<br />PRESSURE TREATED
<br />BLK
<br />BLOCK
<br />HR
<br />HOUR
<br />PTD
<br />PAINTED
<br />BOTT
<br />BOTTOM
<br />HVAC
<br />HEATING/VENTILATING/ PVMT
<br />PAVEMENT
<br />BRG
<br />BEARING
<br />AIR CONDITIONING
<br />QTY
<br />QUANTITY
<br />BTWN
<br />BETWEEN
<br />HW
<br />HOT WATER
<br />REF
<br />REFRIGERATOR
<br />CAB
<br />CABINET
<br />IN
<br />INCH
<br />READ
<br />REQUIRED
<br />CLG
<br />CEILING
<br />INCAND
<br />INCANDESCENT
<br />REINF
<br />REINFORCING
<br />CEM
<br />CEMENT
<br />INCL
<br />INCLUDE
<br />I
<br />RETURN
<br />CL
<br />CLOSET
<br />INFO
<br />INFORMATION
<br />REV
<br />REVERSE, REVISION
<br />CLR
<br />CLEAR
<br />INSUL
<br />INSULATE -INSULATION
<br />RGD
<br />RIGID
<br />COL
<br />COLUMN
<br />INT
<br />INTERIOR
<br />RM
<br />ROOM
<br />CONC
<br />CONCRETE
<br />KIT
<br />KITCHEN
<br />RO
<br />ROUGH OPENING
<br />CONSTR CONSTRUCTION
<br />LAM
<br />LAMINATED
<br />SCHED
<br />SCHEDULE
<br />CONT
<br />CONTINUOUS
<br />LAV
<br />LAVATORY
<br />SD
<br />SOAP DISPENSER
<br />CONTR
<br />CONTRACTOR
<br />LB
<br />POUND
<br />SEP
<br />SEPARATE
<br />CT
<br />CERAMIC TILE
<br />LIN
<br />LINEAR
<br />SECT
<br />SECTION
<br />CTR
<br />CENTER
<br />LL
<br />LIVE LOAD
<br />SHLF
<br />SHELF
<br />DEG
<br />° DEGREE
<br />LT
<br />LIGHT
<br />SHT
<br />SHEET
<br />DEPT
<br />DEPARTMENT
<br />LVR
<br />LOUVER
<br />SIM
<br />SIMILAR
<br />DET
<br />DETAIL
<br />MATL
<br />MATERIAL
<br />SPEC
<br />SPECIFICATION
<br />DF
<br />DRINKING FOUNT
<br />MAX
<br />MAXIMUM
<br />SPKR
<br />SPEAKER
<br />DIA
<br />DIAMETER
<br />MECH
<br />MECHANICAL
<br />SQ
<br />SQUARE
<br />DIM
<br />DIMENSION
<br />MEMB
<br />MEMBRANE
<br />STD
<br />STANDARD
<br />DN
<br />DOWN
<br />MTL
<br />METAL
<br />STL
<br />STEEL
<br />DR
<br />DOOR
<br />MFC
<br />METAL FURRING
<br />STOR
<br />STORAGE
<br />DWG
<br />DRAWING
<br />CHANNEL
<br />SUB
<br />SUBSTITUTE
<br />EA
<br />EACH
<br />MFR
<br />MANUFACTURER
<br />SURF
<br />SURFACE
<br />EL
<br />ELEVATION
<br />MIN
<br />MINIMUM
<br />SUSP
<br />SUSPENDSYSTEM
<br />ELEC
<br />ELECTRICAL
<br />MIR
<br />MIRROR
<br />T & G
<br />TONGUE & GROOVE
<br />EQ
<br />EQUAL
<br />MISC
<br />MISCELLANEOUS
<br />TEL
<br />TELEPHONE
<br />EQUIP
<br />EQUIPMENT
<br />MO
<br />MASONRY OPENING
<br />THK
<br />THICK -THICKNESS
<br />EQUIV
<br />EQUIVALENT
<br />MR
<br />MOISTURE RESISTANT
<br />TPH
<br />TOILET PAPER HOLDER
<br />EW
<br />EACH WAY
<br />NAT
<br />NATURAL
<br />TRANS
<br />TRANSFORMER
<br />EXH
<br />EXHAUST
<br />INOT
<br />IN CONTRACT
<br />TYP
<br />TYPICAL
<br />EXIST
<br />EXISTING
<br />#
<br />NUMBER
<br />UGND
<br />UNDERGROUND
<br />EXT
<br />EXTERIOR
<br />NOM
<br />NOMINAL
<br />UL
<br />UNDERWRITERS LAB.
<br />FD
<br />FLOOR DRAIN
<br />NITS
<br />NOT TO SCALE
<br />VERT
<br />VERTICAL
<br />FIN
<br />FINISH
<br />OA
<br />OVERALL, OUTSIDE AIR
<br />W/
<br />WITH
<br />FIX
<br />OC
<br />ON CENTER
<br />WC
<br />WATER CLOSET
<br />IFIXTURE
<br />FLOOR
<br />OPG
<br />OPENING
<br />WH
<br />WATER HEATER
<br />FLUOR
<br />FLUORESCENT
<br />OPP
<br />OPPOSITE
<br />WM
<br />WIRE MESH
<br />IORIG
<br />FOOTING
<br />ORIGINAL
<br />W/O
<br />WITHOUT
<br />FURR
<br />FURRING
<br />PART
<br />PARTITION
<br />WP
<br />WATERPROOF
<br />GA
<br />PL
<br />PLATE
<br />WS
<br />WEATHER STRIPPING
<br />GALV
<br />GAGE, GAUGE
<br />PLAS
<br />PLASTER
<br />WWF
<br />WELDED WIRE FABRIC
<br />GALVANIZED
<br />PLYWD
<br />PLYWOOD
<br />GENERAL NOTES �
<br />THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY
<br />DISCREPANCIES IN WRITTING PRIOR TO SUBMITTING HIS BID.
<br />THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO THE SUBMISSION OF ANY BIDS, AND VERIFY THE ARCHITECTS DIMENSIONS,
<br />DETAILS AND INFORMATION PERTAINING TO THE PROJECT. IF ANY DISCREPANCIES, CONFLICTING INFORMATION, ERRORS OR OMISSIONS
<br />ARE PRESENT, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND OWNER IMEDIATELY !N WRITTING. ANY DISCREPANCY, OR CONFLICT
<br />NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT AND OWNER PRIOR TO THE FINAL BID SUBMISSION SHALL BE CORRECTED BY THE
<br />CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
<br />THE CONTRACTOR SHALL NOT SCALE THE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.
<br />THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL CARRY PUBLIC LIABILITY, PROPERTY, AND WORKMEN'S COMENSATION
<br />INSURANCE. VALID CERTIFICATES OF ALL SHALL BE PROVIDED.
<br />THE CONTRACTOR SHALL INCLUDE ALL WORK NECESSARY TO ASSURE THE PROJECTS COMPLIANCE WITH THE MOST STRINGENT
<br />REQUIREMENTS OF THE FLORIDA BUILDING CODE, CURRENT LOCAL EDITION, 101 AND ALL OTHER REGULATION CODES.
<br />THE CONTRACTOR SHALL OBTAIN ALL PERMITS, AND SECURE ALL CERTIFICATES OF INSPECTION AND OCCUPANCY THAT ARE REQUIRED
<br />BY THE GOVERNING JURISDICTION. THE OWNER SHALL RECEIVE A COPY OF THE PERMIT UPON ISSUANCE.
<br />THE CONTRACTOR SHALL REFERENCE THE BUILDING SHELL DRAWINGS FOR ALL INFORMATION RELATIVE TO THE BUILDING SHELL AND
<br />FOR COORDINATION OF NEW WORK.
<br />THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS/VENDORS SHALL FAMILIARIZE THEMSELVES WITH AND CONFORM TO ALL
<br />REQUIREMENTS SET FORTH BY THE BUILDING OWNER OR MUNICIPALITY RELATIVE TO THE HOURS OF WORK.
<br />THE CONTRACTOR SHALL SUBMIT A DETAILED CONSTRUCTION SCHEDULE COORDINATION ALL SUBCONTRACTORS, SUPPLIERS AND
<br />VENDORS.
<br />THE CONTRACTOR SHALL NOT ALLOW ON THE PROJECT ANY MATERIALS CONTAINING ASBESTOS, PETROLEUM OR PCB.
<br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND DISTRIBUITING ALL CUPPENT DRAWINGS TO THE
<br />SUBCONTRACTORS/VENDORS AS WELL AS SUPERVISING AND COORDINATING THE WORw, OF ALL TRADES IN ACCORDANCE WITH THE
<br />SPECIFICATIONS AND MAKING ADJUSTMENTS IN LAYOUT AS REQUIRED. THE ARCHI SHALL BE NOTIFIED PRIOR TO THE EXECUTION
<br />OF THEIR REVISIONS TO AVOID CONFLICT BETWEEN TRADES FOR PROPER EXECUTION OF 1 HE WORK.
<br />THE CONTRACTOR SHALL INSTALL ANY APPARATUS, APPLIANCE, MATERIAL OR WORK NOT SHOWN ON THE DRAWINGS BUT MENTIONED IN
<br />THE SPECIFICATIONS, OR VICE VERSA, OR ANY INCIDENTAL ACCESSORIES NECESSARY FOR COMPLETION OF THE WORK FOR OPERATION
<br />WITHOUT ADDITIONAL EXPENSE TO OWNER.
<br />THE CONTRACTOR SHALL COORDINATE ALL OWNER/TENANT SUPPLIED ITEMS AND INCORPERATE THE INSTALLATION INTO THE
<br />CONTRUCTION SCHEDULE.
<br />THE CONTRACTOR SHALL PROVIDE ANY TEMPORARY UTILITIES INCLUDING, ELECTICAL, WATER, AND TELEPHONE REQUIRED FOR THE
<br />COMPLETION OF THE PROJECT.
<br />OWNER.
<br />THE CONTRACTOR SHALL HAVE A DITIGITAL CAMERA ON SITE TO DOCUMENT ANY ISSUES THAT MAY NEED TO BE CLARIFIED. THESE
<br />PICTURES SHALL BE EMAILED TO THE ARCHITECT ALONG WITH AN RFI FOR CLARIFICATION.
<br />THE CONTRACTOR SHALL PROVIDE AT ALL TIMES PROTECTION FROM THE WEATHER AND EXCESSIVE DUST THAT MAY IN ANY WAY
<br />DAMAGE THE WORK, MATERIAL, FIXTURES, AND EQUIPMENT, OR PRESENT DANGER TO PERSONNEL. ANY WORK UNDER CONTRACT BY THE
<br />GERNERAL CONTRACTOR DAMAGED BY A FAILURE TO PROVIDE ADEQUATE PROTECTION SHALL BE REMOVED AND REPLACED WITH NEW
<br />WORK AT THE SOLE EXPENSE OF THE CONTRACTOR.
<br />THE CONTRACTOR SHALL MAINTAIN THE JOB SITE FREE FROM RUBBISH AND DEBRIS. DISPOSAL OF ALL CONSTRUCTION DEBRIS SHALL
<br />CONFORM TO BUILDING REGULATIONS.
<br />THE CONTRACTOR SHALL RUN FIRE RATED WALLS AND PARTITIONS TO UNDERSIDE OF RATED ROOF/CEILING ASSEMBLY ABOVE: TAPE
<br />AND SEAL JOINTS. PROVIDE FIRE DAMPERS AT DUCT PENETRATIONS AS REQUIRED BY CODE. TAPE AND SEAL OTHER PENETRATIONS TO
<br />MAINTAIN INTEGRITY OF FIRE -RATED PARTITION USING ONLY UL APPROVED MATERIAL.
<br />THE CONTRACTOR SHALL FINISH GYPSUM WALLBOARD ABUTTING OTHER MATERIAL WITH METAL EDGE STRIPS. CONCEAL PIPING,
<br />DUCTWORK, AND CONDUIT.
<br />THE CONTRACTOR SHALL BACK ALL ELECTRICAL CABINETS, FIRE EXTINGUISHERS, CABINETS AND OTHER RECESSED EQUIPMENT
<br />LOCATED IN FIRE -RATED WALLS WITH 5/8"TYPE'X' GYPSUM BOARD AS REQUIRED TO MAINTAIN THE RATING.
<br />THE CONTRACTOR SHALL PROVIDE BRACING OR BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED EQUIPMENT: CABINETS, GRILLES,
<br />DOORS, WINDOWS, ETC.. WOOD BLOCKING SHALL BE FIRE RETARDANT TREATED. METAL STUDS MAY BE USED IN LIEU OF WOOD
<br />BLOCKING.
<br />THE CONTRACTOR SHALL NOT CUT ANY STEEL, WOOD, OR OTHER MAIN STRUCTURAL MEMBERS WITHOUT WRITTEN APPROVAL OF THE
<br />STRUCTURAL ENGINEER.
<br />ANY ROOM, WALL, FLOOR, OR CEILING FINISH NOT SCHEDULED SHALL BE ASSUMED TO BE IDENTICNTICAL TO THE CLOSEST ROOM OF
<br />SIMILAR USE AND TYPE FOR PURPOSES OF BIDDING AND CONSTRUCTION. NOTIFY THE ARCHITECT OF ANY OBSERVED APPARENT
<br />DISCREPANCIES IN WRITTING PRIOR TO COMMENCING WITH THE WORK.
<br />ANY DETAIL NOT SPECIFICALLY REFERENCED SHALL BE ASSUMED TO BE SIMILAR TO THAT SHOWN IN THE CLOSEST POSITION WHERE A
<br />SIMILAR CONDITIONS OCCURS FOR THE PURPOSES OF BIDDING AND CONSTRUCTION. NOTIFY THE ARCHITECT IN WRITTING OF ANY
<br />OBSERVED APPARENT DISCREPANCIES PRIOR TO COMMENCING WITH THE WORK.
<br />WHERE TWO OR MORE DETAILS, MATERIALS, OR CONDITIONS OCCUR IN APPARENT CONFLICT, THE CONTRACTOR SHALL INCLUDE THE
<br />MOST COSTLY SOLUTION IN HIS BID AND NOTIFY THE ARCHITECT OF ANY APPARENT DISCREPANCIES PRIOR TO START OF
<br />CONSTRUCTION.
<br />THE CONTRACTOR SHALL PROVIDE UPON COMPLETION OF THE WORK A SET OF "AS -BUILT" NEATLY MARKED UP PLANS, THE ELECTRICAL
<br />CONTRACTORS "AS -BUILT" DRAWINGS SHALL BE INCLUDED. THESE DRAWINGS SHALL BE TRANSMITTED TO THE OWNER.
<br />DMF
<br />Revd by STATE FLORIDA
<br />RB AR0016160
<br />CT 2 5 2012
<br />-1o
<br />z
<br />z�UU U
<br />z�
<br />UOUv0zzUz
<br />wW
<br />z~
<br />w oQ
<br />_0:� W z n W
<br />W U O—
<br />�W—
<br />O W Z z z
<br />W���= zW
<br />_
<br />oLLJ o Qm
<br />Q O~ z= w z
<br />=Y)<un � Wo
<br />z CLLLI
<br />�QUQ
<br />000= n
<br />0,Wzo<z o� —
<br />mo
<br />yO�lI
<br />W
<br />�zI-
<br />0�Q
<br />�W
<br />�zw�
<br />LJ Uo0nw UU
<br />w~=�-U�z
<br />zQ w=
<br />O Uz zQ
<br />Q
<br />>U
<br />L-i~OZU LLI
<br />z
<br />O
<br />IO U
<br />� Z m � Z W d n�
<br />O = Q w Q
<br />Of
<br />U= Q
<br />U F~< 0 Z Z
<br />z� v U
<br />z U Z.Z~ O W Q C:) U
<br />WwO
<br />�U
<br />G u�-0 LL1�
<br />0cif
<br />OF—W
<br />�U W
<br />EK =Z
<br /><UO
<br />rD =U
<br />w— WD�WUn nW�n Q
<br />v,U z
<br />U=O
<br />v�UZZOzu U
<br />�<MU
<br />�__<0u�zuzUo�Q
<br />©COPYRIGHT 2012
<br />BARR ARCHITECTURAL STUDIO
<br />Revisions:
<br />W
<br />�
<br />;
<br />(v)
<br />a
<br />(.0
<br />J
<br />m
<br />J
<br />LL
<br />V.-
<br />J
<br />W
<br />J
<br />�J
<br />W
<br />_
<br />W
<br />aN�
<br />cv
<br />z
<br />U
<br />r
<br />_
<br />a
<br />w
<br />N
<br />(00
<br />Sheet Title
<br />a)
<br />c
<br />CO
<br />co
<br />m N
<br />N
<br />L� r.
<br />ai
<br />N
<br />Ln
<br />ti 0)
<br />O 4-:
<br />a)
<br />ti
<br />N
<br />0 m
<br />N 00
<br />W
<br />W
<br />�O
<br />GENERAL NOTES
<br />Seale AS NOTED
<br />Date: 10-18-12 1 Sheet No.
<br />Project No.
<br />12-1018 GN
<br />L_
<br />O
<br />C
<br />C
<br />.E
<br />C
<br />(a
<br />C
<br />O
<br />E
<br />N
<br />to
<br />C
<br />N
<br />E
<br />C
<br />O
<br />V
<br />L
<br />C
<br />O
<br />U
<br />
|