11 11 _11 I I III I_ 1 11 1 - I <br />GENERAL <br />K 1 r- r_% 81 PROJECT NOTES <br />C)ENERAL I 1\4 <br />GENERAL NOTES: <br />1 INTERPRETATION, ERRORS AND OMISSIONS: <br />SHOULD ANY OMISSION, DISCREPANCY, AMBIGUITY OR ERROR <br />IN THE CONTRACT DOCUMENT DRAWINGS BE DISCOVERED OR <br />SHOULD THERE BE ANY DOUBT AS TO THE MEANING OR INTENT <br />THEREOF, REPORT SUCH FINDINGS TO THE ARCHITECT IN WRITING. <br />WITHIN A REASONABLE TIME OF RECOVERY <br />IF buklN6 THE— CURSE OF CONSTRUCTION, CONFLICTS ARE <br />FOUND IN THE DRAWINGS OR EXISTING SITE CONDITIONS, <br />THE ARCHITECT WILL INTERPRET OR CONSTRUE THE DRAWING(S) <br />AND / OR EXISTING SITE CONDITIONS SO AS TO SECURE THE <br />MOST SUBSTANTIAL AND COMPLETE PERFORMANCE OF THE WORK. <br />2. DIMENSIONS ON PLANS ARE TO FINISH FACE OF WOODIMETAL STUD PARTITIONS <br />AND FACE OF CONCRETE MASONRY UNIT WALLS UNLESS NOTED OTHERWISE. <br />3. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS <br />PRIOR TO BEGINNING DEMOLITION AND/OR CONSTRUCTION- ANY DISCREPANCIES <br />BETWEEN ACTUAL CONDITIONS AND THOSE REPRESENTED IN THE CONSTRUCTION <br />DOCUMENTS SHALL BE BROUGHT TO THE ARCHITEcrs ATTENTION IMMEDIATELY. <br />4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING UTILITIES <br />PRIOR TO CONSTRUCTION SHOULD THE ASSISTANCE OF THE OWNER, ARCHITECT OR <br />ENGINEER BE REQUIRED THE CONTRACTOR SHALL ALLOW FOR THE REQUIRED NOTIFICATION <br />PERIOD IN THE CONSTRUCTION SCHEDULE- <br />5. STUD THICKNESS SHALL BE INCREASED AS REQUIRED AT PLUMBING <br />HANGERS, ELECTRICAL PANELS, ETC., WHICH EXCEED 4° FROM FINISH <br />WALL FACE TO BACK OF UNIT. <br />6. FURNISH ACCESS PANELS IN WALLS AND NON -ACCESSIBLE TYPE <br />CEILINGS WHERE SERVICE OR ADJUSTMENT 70 MECHANICAL, <br />PLUMBING OR ELECTRICAL EQUIPMENT IS REQUIRED. <br />(SEE ENGINEERING DRAWINGS FOR ANY REQUIRED ACCESS PANEL(S) <br />FOR THIS PROJECT) <br />7. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD AT 30 FEET O.C. <br />MAXIMUM PER MANUFACTURER'S RECOMMENDATION. WHERE <br />POSSIBLE, LOCATE JOINTS ABOVE DOOR FRAMES. <br />8, GYPSUM WALLBOARD IN TOILETS, AND OTHER <br />AREAS SUBJECT TO WETTING, SHALL BE MOISTURE RESISTANT <br />TYPE GIN WALLS- ON WALLS TO RECEIVE CERAMIC TILE, FINISH <br />GYPSUM WALLBOARD SHALL BE MOISTURE RESISTANT TYPE. <br />9, ALL GYPSUM WALLBOARD IN FIRE RATED WALLS SHALL BE FIRE RESISTANT <br />UL CLASSIFIED MATERIAL APPLIED IN STRICT CONFORMANCE TO THE <br />APPLICABLE FIRE TEST DESIGN WITH JOINTS ON OPPOSITE WALL FACES <br />STAGGERED. FASTENERS SHALL BE OF APPROVED TYPE AND <br />INSTALLED IN ACCORDANCE WITH APPLICABLE FIRE TEST. ALL <br />WALLBOARD JOINTS SHALL BE TAPED AND FINISHED WITH JOINT <br />COMPOUND, INCLUDING THOSE ABOVE CEILING, WHETHER FIRE RATED <br />OR NOT PENETRATION FOR PIPES, CONDUIT, DUCTS, ETC. IN EXCESS <br />OF 8' IN MAXIMUM DIMENSION SHALL BE FRAMED. PERIMETER OF <br />PENETRATIONS SHALL BE TIGHTLY PACKED WITH MINERAL FIBER SAFING <br />INSULATION. <br />w CONTRACTOR SHALL VERIFY AND COORDINATE SPECIFIC REQUIREMENTS <br />FOR OWNER -PROVIDED AND/OR INSTALLED EQUIPMENT- <br />11. ALL OTHER MAJOR TENANTS AND SHOP CONSTRUCTION IS DESCRIBED <br />WITHIN SEPARATE WORKING DRAWINGS, <br />12. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING <br />ALL WORK INCLUDED IN THE CONTRACT DOCUMENTS. ALL CORRESPONDENCE <br />FROM SUBCONTRACTORS SHALL BE ROUTED THROUGH THE GENERAL CONTRACTOR <br />13 ADJACENT WORK, INCLUDED UNDER OTHER CONSTRUCTION CONTRACTS, WHICH <br />IS DAMAMGED DURING EXECUTION OF THIS CONTRACT WORK, SHALL BE THE <br />RESPONSIBILITY OF THE GENERAL CONTRACTOR TO REPAIR PRIOR TO FINAL <br />ACCEPTANCE OF THE WORK <br />14 GENERAL CONTRACTOR SHALL REPLY WITH ALL REQUIREMENTS OF <br />CURRENT SOILS REPORT. <br />15 GENERAL CONTRACTOR TO PROVIDE ALL GOVERNMENT -REQUIRED SIGNAGE <br />NECESSARY FOR CERTIFICATE OF OCCUPANCY (FIRE LANE 5IGNAGE, <br />'DO NOT BLOCK DOOR-, ETC.) <br />W ALL FIRE RATED CONSTRUCTION SHALL CONFORM WITH U.L. TESTED <br />STANDARDS ANDIOR LOCAL REQUIREMD4TS_ <br />17. CONTRACTOR TO INCLUDE IN BID, ALL MISCELLANEOUS MATERIAL REQUIRED <br />FOR A COMPLETE INSTALLATION PER THE DESIGN INTENT AS DEFINED <br />BY THE CONTRACT DOCUMENTS. MISCELLANEOUSMATERIAL INCLUDES, BUT IS <br />NOT LIMITED TO FASTENERS, HANGERS, FURRING STRIPS, BLOCKING, TRIM <br />AND OTHER MATERIALS NOT SPECIFICALLY INDICATED ED BUT REQUIRED <br />FOR A COMPLETE INSTALLATION. <br />SITEWORK NOTES. <br />I. FOUNDATIONS HAVE BEEN DESIGNED FOR ALLOWABLE SOIL BEARING AS NOTED <br />ON STRUCTURAL DRAWINGS- THR GENERAL CONTRACTOR SHALL BE RESPONSIBLE <br />FOR COORDINATING INSPECTION OF SOIL CONDITIONS AFTER EXCAVATION WITH <br />OWNER',$ TESTING SERVICE TO DETERMINE IF BEARING CAPACITY IS <br />SUFFICIENT AND MAINTAINING EXCAVATION IN SUCH AS A WAY THAT THE BEARING <br />CAPACITY IS MAINTAINED UNTIL PLACEMENT OF FOOTING. <br />2. OVER -EXCAVATION OF FOUNDATIONS SHALL BE FILLED ONLY AS DIRECTED BY <br />THE STRUCTURAL ENGINEER. <br />3. ALL CIVIL WORK IS DEFINED UNDER SEPARATE CIVIL DOCUMENTATION <br />PROVIDED BY THE CIVIL ENGINEER. <br />4. UNLESS NOTED OTHERWISE, PROVIDE 18'x 24'CONCRITE SPLASH BLOCKS <br />AT ALL DOWNSPOUTS WHERE DOWNSPOUTS SPILL ONTO ASPHALT PAVING <br />5, REFER TO CIVIL DRAWING FOR PAVING THICKNESS, CURB TYPES, LONGITUDINAL AND <br />AND HORIZONTAL CONTROL. FOR BUILDING LOCATION SETBACKS REFER TO <br />CIVIL DRAWINGS- <br />6. REFER TO LANDSCAPE DRAWINGS FOR LANDSCAPE REQUIREMENTS - (N-1 C) <br />7. COORDINATE WATER (DOMESTIC AND FIRELINE) AND GAS METER LOCATIONS <br />WITH CIVIL ENGINEER- FIELD VERIFY ALL LOCATIONS. <br />8. FIELD COORDINATE TRANSFORMER PAD LOCATIONS WITH ELECTRICAL ENGINEER <br />REFER TO ELECTRICAL & CIVIL DRAWINGS FOR GENERAL INFORMATION <br />9. REFER TO A100 FOR SIDEWALK REQUIREMENTS <br />10, THE CONTRACTORS AND SUBCONTRACTORS SHALL COORDINATE THE WORK <br />AND PHASING OF WORK DESCRIBED HEREIN WITH THE CIVIL ENG NEERING <br />AND LANDSCAPE PLANS ISSUED SEPARATELY BY: <br />CIVIL; CDG ENGINEERS& ASSOCIATES, INC. <br />LANDSCAPE: N I.C. <br />11 CONNECTIONS TO UNDERGROUND UTILITY LINES AT 6 OUTSIDE <br />THE BUILDING SHALL BE MADE BY THE BUILDING CONTRACTOR. CONTRACTOR TO <br />PROVIDE SECONDARY RADEWAY AND CONDUCTOR FROM THE TRANSFORMER TO THE <br />PANEL AT EACH BUILDING PANEL AND LANDLORD PANEL- COORDINATE WITH <br />CIVIL UTILI TY DRAWINGS. FIELD COORDINATE AS NECESSARY. <br />CONCRETENOTES: <br />1. DESIGN LOADS AREAS SPECIFIED BY THE STRUCTURAL DRAWINGS, <br />MASONRY NOTES: <br />1. ALL MASONRY VENEER SHALL BE 100% SOLID MATERIAL AT CORBEL AND/OR <br />REVEAL TRIM WORK PRESENT ALTERNATE SOLUTION(S) TO ARCHITECT FOR APPROVAL. <br />WOOD NOTES: <br />1. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING AND PROVIDING REQUIRED <br />BLOCKING FOR ALL WALL MOUNTED EQUIPMENT AND FIXTURES FIELD COORDINATE. <br />THERMAL & MOISTURE PROTECTION NOTES:. <br />1 . ALL FLASHING DETAILS ARE TO BE IN ACCORDANCE WITH SMACNA "ARCHITECTURAL. <br />SHEET METAL MANUAL', MOST CURRENT EDITION PRESENT PROPOSED ALTERNATE <br />TO ARCHITECT FOR APPROVAL- <br />2 ALL GUTTERS, DOWNSPOUTS, GRAVEL STOPS, FASCIAS, FLASHING, LOUVERS, SCREENS, <br />METAL STRUCTURES AND ANY ROOF PENETRATIONS ARE TO BE INSTALLED AND <br />FABRICATED AS PER SMACNA STANDARDS OR IN ACCORDANCE WITH ROOFING <br />MANUFACTURE'S RECOMMENDATIONS AS REQUIRED TO OBTAIN MANUFACTURE'S <br />WARRANTIES REOUIRED BY THE SPECIFICATIONS. PRESENT PROPOSED ALTERNATE(S) <br />TO ARCHITECT FOR APPROVAL. <br />3. R-RATINGS FOR ASSEMBLIES ARE TO MEET OR EXCEED THE ENERGY EFFICIENCY <br />REQUIREMENTS OF THE CURRENT ENERGY CODE OR TENANT REQUIREMENT, <br />WHICHEVER IS GREATER. <br />4. CONTRACTOR SHALL PROVIDE FLASHING FOR ALL WINDOWS, STOREFRONT AND <br />DOOR JAMBS, SILLS & HEADS, SUBMIT SHOP DRAWINGS FOR ARCHITECT'S APPROVAL <br />PRIOR TO START OF CONSTRUCTION. <br />5 CAULK THE INTERIOR PERIMET ER AND SEAL THE EXTERIOR PERIMETER OF ALL <br />DOORS. STOREFRONTS AND WINDOWS WITH APPROVED CAULKING AND SEALANT REFER <br />TO SPECIFICATIONS FOR ACCEPTABLE MATERIALS <br />6 ALL EXTERIOR DOORS ARE TO BE WEATHERSTRIPPED WITH THRESHOLDS SET IN <br />CAULKING BED. PROVIDE RAIN GUARDS AT HEAD AS REQUIRED- SUBMIT SAMPLES TO ARCHITECT <br />FOR APPROVAL PRIOR TO BEGINNING THE WORK <br />7. GENERAL CONTRACTOR IS TO PROVIDE A THERMAL BARRIER BETWEEN THE ROOF DECK <br />AND THE INSULATION. APPROPRIATE THERMAL BARRIER IS DICTATED IN THE FOAM <br />PLASTICS INSULATION SECTION OF THE CURRENT BUILDING CODE, THERMAL <br />BARRIER MAY BE OMITTED ONLY IF THE CONTRACTOR CAN PROVIDE TEST DATA WHICH STATES <br />THAT THE INSULATION INTENDED FOR USE ON THIS PROJECT PASSES UL 1256 AND/OR FM 4450- <br />GENERAL CONTRACTOR TO PROVIDE SILL FLASHING BY WINDOW WALL MANUFACTURER. <br />FLASHING IS A REQUIRED INTEGRAL PART OF THE SPECIFIED WINDOW WALL SYSTEM. <br />P, - GENERAL CONTRACTOR TO PROVIDE BITUMINOUS DAMPROOFING OVER ALL C.M.U. WHERE <br />ARCHITECTURAL VENEER OR BRICK VENEER OCCURS. <br />0- GENERAL CONTRACTOPTO PROVIDE BITUMINOUS MEMBRANE WATER PROOFING AT ALL AREAS <br />WHERE INTERIOR FINISH GRADE IS BELOW EXTERIOR FINISH GRADE. <br />SEAL ALL PENETRATIONS AT EXTERIOR WALLS TO INSURE WEATHER TIGHTNESS. <br />DOORNOTES <br />I . HOLLOW METAL DOOR FRAMES LOCATED IN EXTERIOR BLOCK WALLS SHALL BE FILLED <br />WITH GROUT. <br />2. EXTERIOR AND INTERIOR PASSAGE DOORS WHERE OPERABLE HARDWARE IS PROVIDED <br />SHALL BE EQUIPPED WITH HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING <br />HARDWARE DEVICES HAVING A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES <br />NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR ANY WRIST -TWISTING MOTION <br />TO OPERATE. <br />3. TO AID BLIND, VISUALLY IMPAIRED PERSONS OR PERSONS WITH LOW VISION CAPABILITIES, <br />DOORS LEADING TO LOADING DOCKS OR PLATFORMS, BOILER ROOMS, STAGES, ELECTRICAL <br />EQUIPMENT ROOMS, ETC- SHALL BE MADE READILY IDENTIFIABLE TO THE TOUGH BY A <br />TEXTURED SURFACE ON THE DOOR HANDLE, KNOB, PULL OR OTHER OPERATING HARDWARE. <br />PROVIDE ALL REQUIRED ADA COMPLIANT SIGNAGE AT AREAS LISTED ABOVE. <br />FINISH NOTES: <br />I. CLEAN AND PRIME ALL SURFACES PRIOR TO PAINTING IN ACCORDANCE WITH PAINTING <br />MANUFACTURER'S RECOMMENDATIONS. PAINT ALL SIX SURFACES OF DOORS AS WELL <br />2. METAL ACCESS PANELS AND ELECTRICAL PANEL LOUVERS SHALL NOT BE PAINTED <br />WITH LATEX PAINT. PAINT PANELS WITH OIL BASED GLOSS ENAMELS MATCHING <br />MANUFACTURER'S RECOMMENDATIONS- <br />3, METAL STUD GAUGES (SEE DRAWINGS) AND BRACING REQUIREMENTS FOR INTERIOR <br />PARTITIONS SHALL BE AS RECOMMENDED AND/OR REQUIRED BY THE STUD MANUFACTURER <br />(AND ALL APPLICABLE CODES) FOR EACH SPECIFIC CONDITION UNLESS OTHERWISE NOTED. <br />4. PROVIDE DRAFT STOPPING IN CANOPIES AT INTERVALS NOT TO EXCEED 3,0o0 SF <br />9 HORIZ. AREA) AND WHERE SPECIFICALLY CALLED FOR ON DRAWINGS DRAFT STOPPING <br />HALL BE V2" GYP. RD. ON ONE SIDE OF LIGHT GAUGE METAL FRAMING. <br />PLUMBING NOTES: <br />I TOILETS SHALL BE HANDICAP ACCESSIBLE AS REQUIRED BY APPLICABLE LAWS. <br />CODES AND STATUTES- REFER TO TI DRAWINGS FOR EACH TENANT. <br />Z THE ENTIRE STRUCTURE SHALL BE SPRINKLERED (WHEN REQUIRED) IN ACCORDANCE <br />WITH TENANT SPECIFIC REQUIREMENTS AND WITH APPLICABLE CODES. <br />FIRE DEPT NOTES: <br />1. EVERY BUILDING HEREAFTER CONSTRUCTED SHALL BE ACCESSIBLE TO FIRE DEPARTMENT <br />APPARATUS BY WAY OF ACCESS ROADWAYS WITH ALL-WEATHER DRIVING SURFACE <br />OF NOT LESS THAN 20 FT. OF UNOBSTRUCTED WIDTH, WITH ADEQUATE ROADWAY TURNING <br />RADIUS CAPABLE OF SUPPORTING THE IMPOSED LOADS OF FIRE APPARATUS AND <br />HAVING A MINIMUM VERTICAL CLEARANCE OF 13 FT. 6 IN, <br />2. WHERE EXIT LIGHTS, SIGNS OR THE EXITS THEMSELVES ARE NOT VISIBLE FROM <br />THE EXIT APPROACH, DIRECTIONAL SIGNS INDICATING THE WAY OF EGRESS SHALL BE <br />PROVIDED. COORDINATE LEVEL OF SIGNAGE WITH CIVIL DRAWINGS <br />3 AS REQUIRED, SEPARATE OR EMERGENCY SOURCE OF ILLUMINATION SHALL BE PROVIDED <br />IN THE FOLLOWING OCCUPANCIES: <br />a) WINDOWLESS BUILDINGS <br />b) INTERIOR EGRESS CORRIDORS WITH NO NATURAL ILLUMINATION <br />c) OCCUPANT CAPACITIES EXCEEDING 150 PERSONS, <br />APPLICABLE CODE <br />5th ADDITION FLORIDA BUILDING CODE 2014 <br />5th ADDITION FLORIDA PLUMBING CODE 2014 <br />5th ADDITION FLORIDA MECHANICAL CODE 2014 <br />ELECTRICAL CODE :2011 NATIONAL ELECTRICAL CODE <br />5th ADDITION FLORIDA EXISTING BUILDING CODE 2014 <br />5th ADDITION FLORIDA ENERGY CONSERVATION CODE 2014 <br />5th ADDITION FLORIDA FUEL GAS CODE 2014 <br />BUILDING INFORMATION. <br />TOTAL LEASED AREA 1,620 SQ. FT. <br />TOTAL RETAIL AREA 803 SQ. FT. <br />USE GROUP: M <br />IBC SECTION 303.1 <br />CONSTRUCTION TYPE: 2-B, PROTECTED <br />IBC SECTION 602.5 <br />ALLOWABLE AREA: 6,000 SQ. FT. <br />IBC TABLE 503 <br />ACTUAL AREA: 1,620 SQ. FT. <br />FIRE PROTECTION: NOT REQUIRED, NOT PROVIDED <br />IBC SECTION 903.2,1.2 <br />FIRE ALARM: NOT REQUIRED, NOT PROVIDED <br />IBC SECTION 907.2.1 <br />OCCUPANCY: <br />IBC TABLE 1004.1.1 <br />AREA SQ. FT. <br />SF/OCC <br />OCC. LOAD <br />SALES FLOOR 803 <br />60 <br />14 <br />STORAGE/B.O.H. 817 <br />300 <br />3....... <br />17 <br />EGRESS: <br />REQ'D PROVIDED <br />EGRESSWIDTH- DOORS <br />82 x 0.2" = 16.4" 114'' <br />IBC SECTION 1005 <br />NUMBER OF EXITS: <br />2 2 <br />IBC SECTION 1015 <br />EXIT ACCESS TRAVEL DIST. 'M'USE = 200'-0" IBC TABLE 1016.1 <br />COMMON PATH OF TRAVEL 'M'USE = 75'-0" IBC SECTION 1014.3 <br />PLUMBING FIXTURES: IBC TABLE 2902.1 <br />FIXTURE RATIO (M/F) REQ'D PROVIDED <br />WC 1:500/1:500 1/1 1/1 <br />UR --- 0 1 <br />LAV 1:750 1/1 1/1 <br />0 EMobile 0 <br />AT <br />GALL BLVD & DAUGHTERY RD <br />SAP # 511 D <br />7333 GALL BLVD, SUITE #7335 <br />ZEPHYRHILLS, FL 33541 <br />VICINITY MAP <br />NOTES <br />SALES FLOOR <br />- SEE DESIGN DRAWINGS FOR SPECIFICS <br />0 NETWORKING (ONLY HALF OF THE REQUIRED RUNS) <br />0 FAX LINE RAN TO SC PRT FROM NETWORK WALL <br />0 ELECTRICAL EXACTLY AS INDICATED <br />0 LIGHTING EXACTLY AS INDICATED <br />0 CEILING GRID AND TILES AS INDICATED <br />0 FIXTURES TO BE INSTALLED BY GC OR TRIAD WILL DISCUSS) <br />0 FLOORING EXACTLY AS INDICATED (TO BE ORDERED BY GP MOBILE, - <br />GC TO PROVIDE REQUIRED QUANTITIES AND REQUESTED DELIVERY <br />DATE) <br />0 FINISHES EXACTLY AS INDICATED <br />BACK OF HOUSE <br />- REMOVE / BUILD WALLS AS NEEDED <br />- COMMERCIAL GRADE VINYL FLOORING (IF NEEDED) <br />- DUPLEX RECEPTACLE ON EACH WALL IN EVERY ROOM AND HALLWAY <br />I X DUPLEX RJ45 JACK (CAT5E CABLE) IN EACH ROOM <br />-WALL PAINT (SAME AS SALES FLOOR) <br />-VINYL BASEBOARDS <br />- FLUORESCENT LIGHT FIXTURES (IF NEEDED) <br />- STEEL EXIT DOOR SECURITY BARS INSTALLED ON OUTSIDE BACK DOOR <br />(LIKE THIS ONE <br />HTTPS-/NVNW.DOORWARE.COM/SITE/PRODUCT.CFM?ID=181024) <br />- ALL INSIDE DOORS AND FRAMES PAINTED WHITE (GLOSSY PAINT) <br />NETWORKING <br />- NETWORK WALL (4'X 4- PLYWOOD MOUNTED ON WALL NEAR <br />ELECTRICAL PANEL) <br />- 2 X FOURPLEX RECEPTACLES INSTALLED ON NETWORK WALL <br />- SU WALL MOUNTED OPEN RACK INSTALLED ON NETWORK WALL <br />0 INSTALL NETGEAR PROSAFE JGS524NA 24-PORT GIGABIT RACKMOUNT <br />SWITCH 10/100/1000 MBPS (JGS524NA) MOUNTED IN THE RACK <br />0 ETHERNET PATCH PANEL MOUNTED IN THE RACK <br />- CAMERA SYSTEM <br />0 INSTALL 8 CAMERAS (PROVIDED BY GP MOBILE) <br />0 RUN BNC W/ POWER CABLES FROM CAMERA TO NETWORK WALL <br />(PROVIDED BY GP MOBILE) <br />TURNOVER <br />- PERFORM SERVICE ON HVAC SYSTEM <br />0 CLEANING <br />0 FILTERS <br />0 CHANGE THERMOSTAT(S) (PROVIDED BY GP MOBILE) <br />- CLEAN STORE <br />0 WASH FLOORS <br />0 CLEAN FIXTURES <br />0 CLEAN RESTROOMS <br />0 CLEAN WINDOWS <br />ADDITIONAL CONTRACTORS (THAT WILL BE ON SITE DURING PROJECT) <br />-ALARM SYSTEM (ADT OR PRECISION 1) <br />- ROLL DOWN GATES (QMI) <br />- INVENTORY SAFE (BLUE DOT) <br />- SIGNS (MC SIGNS) <br />- SHOPPER TRAK (SHOPPER I RAK) <br />- INTERNET SERVICE PROVIDER <br />KEY PLAN <br />ADDRESS -. 7333 GALL <br />BLVD QITEo73f; <br />I <br />ZEPHYRHILLS, FL.' <br />PROJECT <br />LOCATION <br />PROJECT TEAM <br />PROJECT OWNER I ARCHITECT <br />Company: XXX Company: XXX <br />Address : XXX Address : XXX <br />City, State Zip XXXX City, State Zip XXXX <br />P: XXX P: XXX <br />F: F: <br />Contact: XXX Contact: XXX <br />STRUCTURAL CONTRACTOR <br />pany: XXX Company: T.B.D. <br />Addres xxx Address: XXX <br />City, <br />ity, State Zi xxx City, State Zip XXXX <br />P: XXX P: XXX <br />F: F <br />Contact: XX Contact: XXX <br />ALL WORK SHALL COMPLY WITH <br />PREVAILING CODES <br />IORIDA BUILDING CODE, <br />I%ATIONAL ELEC-RIC CODE, AND <br />CITY OF ZEPHYRHILLS ORIDINANC98 <br />MEP I CIVIL ENGINEER <br />Company: XXX \COM a Address: XXX dd r e�s , n YX" XXX <br />XXX <br />City, State Zip XXXX CiNState Zip XXXX <br />P: XXX P: <br />F: F: <br />Contact: XXX Contact: <br />N3NIVYVX3 INIVId <br />qAHcl3Z �o Ailo <br />� DRAWING INDEX <br />A100 <br />COVER SHEET <br />Al 01 <br />FIXTURE PLAN <br />Alli <br />FINISH PLAN <br />All 21 <br />REFLECTED CEILING PLAN <br />A201 <br />INTERIOR ELEVATIONS <br />A501 <br />DETAILS <br />A601 <br />SCHEDULES <br />El 01 <br />ELECTRICAL GUIDELINES PLAN <br />E501 <br />FIXTURE FEED WIRING DETAILS <br />E511 <br />FIXTURE FEED WIRING DETAILS <br />E512 <br />LIGHTING PLAN <br />r_7 <br />GC SCOPE OF WORK: <br />SCOPE OF WORK INCLUDES THE FOLLOWING: <br />• GC TO REPLACE ANY EXISTING FLOOR MATERIAL AS SHOWN ON <br />PLANS <br />• GC TO REMOVE EXISTING WALL PAINT AND RE -PAINT AS SHOWN <br />ON PLANS. <br />• GC TO INSTALL ALL DISPLAY FIXTURES AS SHOWN ON FIXTURE <br />PLAN. <br />• GC TO REPLACE GRIDS AND CEILING TILES AS SHOWN. <br />• GC TO COORDINATE WITH CITY INSPECTOR REGARDING ANY <br />ADDITIONAL WORK NEEDED TO MEET CITY/LOCAL CODE <br />REQUIREMENTS. <br />Proiect Owner: <br />Consultant: <br />rhaarclaitect <br />Architect + Master Planner <br />16043 Barbarossa Drive <br />Houston, Texas 77083 <br />E-mail: RHAcirchitectsOoolkcom <br />WebsIte: rhc3rris@rhaorchitects.net <br />PNt 01 6E�� <br />94�w gzp� I 1 11 0144 <br />C.11: (832) 545-6319 BussIness: (281) 564-7300 F­ (M) 564-7301 <br />- florida - arkansas - oklahoma - <br />texas - louislana - georgia - mississippi <br />Copyright Protected 2017 <br />Project Address: <br />SAP # 511 D <br />7333 GALL BLVD SITE:7335 <br />ZEPHYRHILLS, FL 33541 <br />No.l Date <br />Description <br />Sheet Title: <br />COVER SHEET Ill <br />\AN <br />O <br />G� PN�� <br />,vw <br />DRAWN BY: A <br />DWG. DATE: 01-19-17 1 cu OX <br />REVIEWED BY- AM / AM <br />PROJECT NUMBER TMO 550 <br />TEMPLATE TYPE XX <br />SHEET: <br />A100 <br />