I ` L111111, I'111!"IFII q, I.11r. I III Jl': I : p111"Jnll1 111111r1I I 1 1ilvi i! '7wIII WWW11®1ng1impri I 1 1 i <br />ADJACENT! <br />TENANT <br />EXTERIOR <br />ADJACENT <br />TENANT <br />D1 T-MOBILE PREFERRED REFLECTED CEILING PLAN <br />1/8" = T-0" <br />i I/\ i VI\L I \J ULV'u r\I IV\7 i VI\ J i PY Li LILP•11 IVIN. <br />SEE SHEET A601 FOR SCHEDULES <br />G.C. TO FIELD VERIFY ALL CEILING HEIGHTS <br />AND NOTIFY ARCHITECTS IMMEDIATELY OF <br />ANY DISCREPANCIES OR UNFORESEEN ITEMS <br />NOT SHOWN ON DRAWINGS. <br />1. ELECTRICAL EQUIPMENT, HVAC EQUIPMENT, AND SPRINKLERS ARE TO BE MOUNTED AT POINTS IN ACP AS NOTED IN <br />SYMBOL DESCRIPTION GRAPHIC BELOW UNLESS OTHERWISE DIMENSIONED ON RCP. REFER TO EDSS INSTALL GUIDELINES FOR LIGHTING. SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br />2X2 ACT TILE 2X4 ACT TILE - - <br />____-. O ❑o SINGLE HEAD ADJUSTABLE <br />SURFACE MOUNTED 2'x2' <br />ARMSTRONG - FINE FISSURED SECOND LOOK- w <br />DESIGNER SERIES 1761, Uw' <br />COLOR: WHITE, 24"X48" TEGULAR EDGE, ARMSTRONG SINGLE HEAD ADJUSTABLE FOR <br />PRELUDE XL 15/16" TEE GRID. Q, Q. EQ. EQ. EQ. EQ. ❑O EMERGENCY OPERATION — - - <br />SURFACE MOUNTED 2'x2' FOR <br />ACP-1 2. CENTER ACT GRID WITHIN EACH ROOM UNLESS OTHERWISE NOTED. EMERGENCY OPERATION <br />---— O O DUAL HEAD ADJUSTABLE <br />3. NO CEILING REQUIRED IN JANITORS CLOSET, IF APPLICABLE. <br />4. PLACEMENT AND NUMBER OF EMERGENCY LIGHTS, NIGHT LIGHTS, AND EXIT LIGHTS ALONG WITH MOUNTING HEIGHT <br />EXISTING TILE AND 24"X48 TEE GRID. G.C. TO REPAIR AS NEEDED DUAL HEAD ADJUSTABLE FOR <br />AND REPLACE INDIVIDUAL CEILING TILES WITH NEW. IF MORE TO BE CONFIRMED BY PARTNER'S ARCHITECT/ENGINEER. SPECIFICATIONS SHOWN ARE FOR REFERENCE ONLY. O O EMERGENCY OPERATION PENDANT MOUNTED 2'x2' <br />THAN 25% OF CEILING TILES ARE DAMAGED, G.C. TO REPORT z <br />CONDITION AND COORDINATE EXTENT OF REPLACEMENT WITH 5. GC TO ADJUST PERIMETER ADJUSTABLE LIGHTS TO BE TARGETED BETWEEN 5'-9" TO 6'-3" VERTICALLY FROM FLOOR <br />PROJECT MANAGER/ARCHITECT TO WASH RETAIL WALL DISPLAYS. —---- <br />ACP-2 6. G.C. TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECTS IMMEDIATELY OF ANY DISCREPANCIES OR O O O TRIPLE HEAD ADJUSTABLE PENDANT MOUNTED 2'x2' FOR <br />UNFORESEEN ITEMS NOT SHOWN ON DRAWINGS. r EMERGENCY OPERATION <br />G.0 SHALL INSTALL CEILING <br />_ IN ACCORDANCE WITH TRIPLE HEAD ADJUSTABLE FOR <br />ARMSTRONG - DESIGNER SERIES 737, 5/8" THICK, ICC ESR 1308 O O O z CEILING MOUNTED VENTILATION FAN <br />EMERGENCY OPERATION <br />COLOR: WHITE, 24"X24" ANGLED TEGULAR EDGE, ICC ESR 1289 WITH LED LIGHT MOTION SENSOR. <br />i <br />ARMSTRONG PRELUDE XL 15/16" TEE GRID IBC SECTION 2508 GC TO CONTACT ARMSTRONG WORLD INDUSTRIES CUSTOMER - - <br />SERVICE REP FOR T-MOBILE PREFERRED PRICING AND TO LOCATE EXIT SIGN WITH BATTERY BACKUP <br />GENERAL CONTRACTOR SHALL FIELD VERIFY LOCAL DISTRIBUTOR OF ARMSTRONG PRODUCTS. GC TO CONFIRM RECESSED 2'x2' <br />ACP-3 EXISTING EGRESS LIGHTING AND PROVIDE WITH LOCAL DISTRIBUTOR ORDER IS FOR T-MOBILE PROJECT: - -- -- — <br />NEW EMERGENCY LIGHT FIXTURES AS <br />REQUIRED BY FIRE MARSHALL CONTACT SHERRY BRUNT OR BETH RINEHART — EMERGENCY LIGHTING <br />FOR NEW: 5/8" GYPSUM BOARD OVER 3 5/8" METAL CUSTOMER SERVICE REPRESENTATIVES <br />FRAMING MEMBERS @ 16" O.C. FINISH TO BE P-2. GC TO CONTACT EDSS ENERGY DESIGN SERVICE ARMSTRONG WORLD INDUSTRIES, INC. RECESSED 2'x2' FOR EMERGENCY — <br />SEE FINISH SCHEDULE SHEET A-7. SYSTEMS FOR T-MOBILE PREFERRED PRICING: PO BOX 3001 OPERATION <br />LANCASTER, PA 17604 R D TRACK LIGHTING <br />CONTACT MICHAEL NORDLOH PHONE: 800-442-4212 <br />FOR EXISTING: 5/8" GYPSUM BOARD OVER EXISTING 810-227-3377 FAX: 800-233-5598 ' SEE G1/A601 FOR T-MOBILE PREFERRED LIGHTING SCHEDULE <br />METAL FRAMING MEMBERS @ 16" O.G. FINISH TO BE MNORDLOH@EDSSENERGY.COM EMAIL: BPO_STRATEGIC ACCOUNTS@ARMSTRONG.COM AND D1/A601 FOR ALTERNATE LIGHTING SCHEDULE IACP-1 CEILING SYSTEM / FINISH <br />GYP P-2 SEE FINISH SCHEDULE SHEET A-7. 10'-6" K. F. F.J CEILING HEIGHT <br />Al CEILING SUMMARY A4 GENERAL NOTES _ A9 SHEET SYMBOLS <br />NOT ALL USED AT THIS LOCATION NOT ALL USED AT THIS LOCATION <br />Project Owner: <br />Consultant: <br />rh aarchitect <br />Architect + Master Planner <br />16043 Barbarossa Drive <br />Houston, Texas 77063 <br />E-mail: RHAarchitects@aol.com <br />Website: rharris®rhaarchitects. ret <br />Cell: (832) 545-6319 Busslnese: (281) 564-7300 Fax: (281) 564-7301 <br />- florida - arkansas - oklahoma - <br />texas - louisiana - georgia - Mississippi <br />Copyright Protected 2017 <br />Project Address: <br />SAP # 511 D <br />7333 GALL BLVD SITE:7335 <br />ZEPHYRHILLS, FL 33541 <br />No. Date Description <br />Sheet Title: <br />REFLECTED CEILING <br />PLAN <br />DRAWN BY: JN <br />DWG. DATE: 01-19-17 <br />REVIEWED BY: AM / AM <br />PROJECT NUMBER: TMO 550 <br />TEMPLATE TYPE: XX <br />SHEET: <br />A121 <br />