P L U M B I N G F I X T U R E S C H E D U L E <br />ROUGH -IN SIZES <br />TAG FIXTURE DESCRIPTION TRIM/ACCESSORIES <br />REMARKS <br />W <br />V <br />CW <br />HW <br />OTHER <br />CO <br />CLEANOUT <br />PVC/CAST IRON (AS REQ'D) <br />BODY WITH RECESSED PLUG/SS PLATE <br />3/4" <br />- <br />- <br />- <br />OR EQUAL <br />12" A.F.F. MIN <br />TEE AND/OR PLUG <br />AND "AT " <br />BASE OF ALL C(TYP.) <br />REL STYLE® OF LINE; SEE <br />or RFOR <br />COORD. w/G.C. <br />SANITARY &HRA NWATER EADERSE <br />PLAN APPL C ONO <br />COG <br />CLEANOUT ON <br />ZURN Z-1406 <br />CAST IRON, NICKLE BRONZE TOP <br />4"/6" <br />- <br />- <br />- <br />OR EQUAL <br />GRADE <br />HEAVY DUTY COVER, PROVIDE CONCRETE <br />PAD WITH CHAMFER EDGES <br />FCO <br />FLOOR <br />ZURN <br />"LEVEL-TROL" <br />4"/6" <br />- <br />- <br />- <br />OR EQUAL <br />CLEANOUT <br />CAST IRON, NICKLE BRONZE TOP <br />FLUSH WITH FLOOR <br />FD1 <br />FLOOR DRAIN <br />ZURN <br />BODY ASSEMBLY WITH Z-400 "B" <br />3"/4" <br />- <br />- <br />- <br />OR EQUAL <br />NOTES 1&2 <br />STYLE STRAINER, NICKEL BRONZE TOP <br />PROVIDE CHEMICAL RESISTANT, OVAL or <br />ROUND FUNNELS ON ALL PROCESS DRAINS <br />EWC <br />ELECT. WATER <br />OASIS PV8ACSL, WALL MTD. W/BRKT <br />8GPH, 120V, 6.OA,1 /4HP, 4.6FLA <br />1-1/4- <br />1-1/2" <br />1/2- <br />- <br />OR EQUAL <br />SEE NOTE <br />COOLER <br />MOUNT AT ADA HEIGHT, S.S. TOP, FLEXIBLE <br />PROVIDE TRAP, STOPS, MTNG. HARDWARE <br />1-1/2 <br />1 BELOW <br />BUBBLER, GAVL. STEEL FRAME, BOTTLE FILLER <br />AS REQUIRED. COORD. w/EC <br />EW <br />FAUCET -MOUNT <br />CHROME -PLATED BRASS SPRAYHEAD ASSEMBLY <br />BRADLEY S19-200B <br />- <br />- <br />- <br />- <br />OR EQUAL <br />EYEWASH <br />WITH TWIN HEADS WITH PROTECTIVE COVERS <br />CHROME FINISH; COORDINATE INSTALLATION <br />MOUNT ON GOOSENECK FAUCET <br />HI ARC FAUCET <br />GRID DRAIN DEARBORN 510 TRAP <br />MR1 <br />MOP SINK <br />ZURN Z1996-24 WITH <br />MR-370 HOSE/CLAMP, MR-371 FAUCET <br />3" <br />- <br />1/2- <br />1/2" <br />OR EQUAL <br />LABEL-CW & <br />5' HOSE MIN <br />MR-373 (3 CLAMP HANGAR, MR-373 <br />HW" OVER <br />MR-374 DGE-LOK SEAL <br />FAUCETS W/ <br />NAMEPLATE <br />L1 <br />LAVATORY <br />ELJER 19" X 17", VITREOUS CHINA, 4" <br />DELTA MODEL 523-WFHGMMDF, ADA WITH <br />1-1/$" <br />1-1/I1" <br />5/r- <br />5/2r <br />OR EQUAL <br />TRUEBRO <br />WALL MOUNTED <br />CENTERS, ARM CARRIERS, ALL MOUNTING <br />CHROME FAUCET, 4" CENTER SET <br />INSUL KIT AS <br />HARDWARE AS REQ'D, ADA. <br />BRASSCRAFT CS400A, DEARBORN 760 <br />REQUIRED <br />GRID DRAIN DEARBORN 510 TRAP <br />L2 <br />LAVATORY <br />18 GA UNDERCOATED STAINLESS STEEL COUNTER <br />LKE4122 ELKAY HI ARC FAUCET, ADA WITH <br />1-1/2- <br />1-1/2- <br />1/2" <br />1/2" <br />OR EQUAL <br />TRUEBRO <br />COUNTERTOP BOWL <br />TOP SINK, 2 HOLE, 18"X18"X8"D ID BOWL DIMS <br />CHROME FAUCET, CENTER MOUNT NECK <br />21' <br />2" <br />INSUL KIT AS <br />ADA STYLE DRAIN <br />w/MOUNTING HARDWARE AS REQ'D. <br />BRASSCRAFT CS400A, DEARBORN 760 <br />REQUIRED <br />SEE NOTE 1 <br />REAR CENTER ADA <br />GRID DRAIN DEARBORN 510 TRAP <br />SS1 <br />SERVICE SINK <br />18x18x5, 18GA, S.S. DBL. BOWL <br />CHICAGO DECK MTD. FAUCET, 8" CENTERS <br />1-1/2" <br />1-1/2" <br />1/2" <br />1/2" <br />OR EQUAL <br />TRUEBRO <br />ADA APPLICATION <br />4-HOLE, SELF RIMMING, <br />HAND SPRAYER, ADA HANDLES, STANDARD <br />2 " <br />2 <br />INSUL KIT IF <br />UNDERCOATED BOWL <br />SPOUT, SUPPLY STOPS, ALL CHROME, TAIL <br />REQUIRED <br />REAR CENTER DRAIN ADA <br />PIECE & P-TRAP, INSUL. KIT ON EXPOSED <br />SEE NOTE <br />ACCESSIBLE TRAPS, w/DEEP WALL <br />1 BELOW <br />COORD. w/ARCH. PLANS, G.C. & CABINETS <br />ESCUTCHEON <br />WC1 <br />WATER CLOSET <br />ELJER, FLOOR MTD.; ELONGATED BOWL; <br />CHURCH 29522C OPEN FRONT SEAT <br />4" <br />2" <br />1 /2" <br />- <br />OR EQUAL <br />SEE NOTE <br />FLOOR MOUNTED <br />VITREOUS CHINA, 1.6 GAL FLUSH <br />WITH COVER, S.S. HINGE POST <br />1 BELOW <br />WHITE, TANK TYPE <br />WC2 <br />WATER CLOSET <br />ELJER, FLOOR MTD.; ELONGATED BOWL; <br />CHURCH 29522C OPEN FRONT SEAT <br />4" <br />2" <br />1 /2" <br />- <br />OR EQUAL <br />SEE NOTE <br />FLOOR MOUNTED <br />ADA HEIGHT WHERE REQ'D. <br />WITH COVER, S.S. HINGE POST <br />1 BELOW <br />ADA <br />VITREOUS CHINA, 1.6 GAL FLUSH <br />WHITE, TANK TYPE <br />1. SEE SHEET ARCHITECTURAL PLANS FOR FIXTURE MOUNTING HEIGHTS, MOUNT PER ADA REQUIREMENTS WHERE APPLICABLE. <br />2. FLOOR TO BE SLOPED TOWARD FLOOR DRAIN(S), COORDINATE WITH G.C. AND FLOOR FINISHER, NO EXCEPTIONS. FCO'S MOUNTED FLUSH WITH NO SLOPE. <br />3. WHERE A TRAP IS SUBJECT TO LOSS BY EVAPORATION, A TRAP PRIMER SHALL BE INSTALLED. TRAP PRIMER SHALL CONFORM TO ASSE 1018 OR ASSE 1044. <br />4. PROVIDE SHOCK ARRESTORS ON ALL QUICK CLOSING FIXTURES AS REQUIRED. (FLUSH VLV's, DISHWASHERS, WASHING MACHINES, ETC.) NOT SHOWN ON PLANS. ARRESTORS <br />SHOULD BE ACCESSIBLE FOR MAINTENANCE, PROVIDE ACCESS PANELS WHERE REQUIRED, MIN. 12xl2 FLUSH MTD. WITH LOCKABLE DOOR. <br />5. APPLICABLE EQUIPMENT SHALL BE PROVIDED WITH ASSE APPROVED BACKFLOW DEVICES, DOUBLE CHECKS, PRV AS REQUIRED IN ORDER TO PREVENT POTENTIAL <br />CONTAMINATION OF POTABLE SOURCE. <br />6. FIXTURE FLUSH VALVE MUST BE LOCATED ON THE WIDE SIDE OF FIXTURE PER NC CODE 11.6.1(4). <br />7. PC TO COORDINATE WITH OWNER AND GC FOR EQUIPMENT SUPPLIED BY OTHERS (ie., KITCHEN/SINK EQUIPMENT) TO MAKE FINAL TIE-IN'S. <br />8. PC SHALL PROVIDE BRANCH SHUT OFF VALVES ON ALL NEW WATER PIPE INSTALLED, PER 606.2.1, IPC 2003. <br />CLEANOUT W/ C. <br />TRAFFIC RATED <br />ACCESS COVER, <br />J❑SAM 58850 <br />OR EQUAL <br />GENERAL PLUMBING NOTES: <br />1. SCOPE OF WORK CONSISTS OF INSTALLING NEW PLUMBING & ALL MODELS, FIXTURES, ETC. ARE IMPLIED 'OR EQUAL' <br />WORK, FIXTURES, PIPE & EQUIP. IN AN EXISITNG SHELL <br />IN LIEU OF ANY SCHEDULED ITEM. ANY ITEM THAT IS <br />SPACE, ALL PLUMBING WORK TO BE COORDINATED WITH ALL <br />SUBSTITUTED SHOULD REFLECT THE GENERAL CRITERIA AS <br />ARCHITECTURAL WORK, PC WORK WILL INVOLVE TRACING <br />SCHEDULED. ITEMS FOUND NO LONGER PRODUCED OR <br />EXISTING SYSTEMS, SANITARY, CW, HW, HWR, VENTS AND <br />MANUFACTURED SHALL BE INCLUDED IN YOUR ESTIMATE AS <br />SPECIAL PIPING ASSOCIATED WITH THIS BUILDING. A <br />AN '❑R EQUAL' ITEM, LABELED & SUBMITTED AS NOTED, <br />COMPLETE WORKING PLUMBING SYSTEM SHALL BE ACHIEVED <br />NO CHANGE ORDERS WILL BE APPROVED FOR DEVIATING <br />THRU THE PROCESS OF THIS UPFIT. <br />FROM THIS PROCEDURE. SEE NOTE No. 3 ABOVE FOR <br />REQUIRED ESTIMATE CORRELATION AND TAKEOFF, <br />2. ALL VENTS SHALL BE LOCATED A MIN. 10'-0' FROM ANY <br />AIR INTAKE LOUVER/DAMPER 7.INSULATE <br />ALL INSTALLED WATER PIPING WITH A MINIMUM <br />OF 2' FIBERGLASS INSULATION OR 1' THK CELLULAR <br />3, PIPING ROUTED IN WALLS, CEILING, ATTIC, ETC. TO AVOID <br />FOAM STYLE INSULATION WITH NO SEAMS GLUED ENDS <br />STRUCTURE, DUCTWORK & OTHER EQUIPMENT. COORDINATE <br />AND CORNERS. USE PLENUM RATED INSULATION. <br />LOCATIONS WITH ALL DRAWINGS AND PARTICULARLY <br />ALL TRADES INVOLVED. INVESTIGATE ROUTING & C❑NFLICTS& ALL ROUGH -IN CUTTING BY PC FOR THEIR SCOPE OF WORK, <br />BEFORE COMPLETING ESTIMATING/TAKEOFF. THE LAYOUT <br />ALL PATCHING (ROUGH), BY PC, FINAL FINISHES BY GC. <br />SHOWN ON PLAN IS THE ENGINEERING INTENT, MEANING <br />THIS DESIGN TAKES INTO CONSIDERATION A MEASURE 9.NO <br />KNOWN RECORD 'AS -BUILT' PLANS/DRAWINGS FOR THIS <br />OF DIVERSITY WHILE CALCULATING. NOT ALL FITTINGS ARE <br />BUILDING EXIST. ORIGINAL PLANS WERE USED FOR LAYOUT, <br />SHOWN & 'DEAD -ON' DEVELOPED LENGTHS ARE IMP❑SSIBLE <br />TIE IN LOCATIONS ARE APPROXIMATE DUE TO VARI❑US <br />TO SHOW. CONTRACTOR'S ROUTINELY ADJUST ROUTINGS & <br />UPFITS AND CHANGES FROM ORIGINAL CONSTRUCTION, PC <br />INSTALLATION TO ACCOMMODATE A SPECIFIC FIELD CONDITION <br />SHALL INVESTIGATE ALL ROUTING BEFORE INSTALLING ANY <br />THAT IS UNKNOWN, UNFORESEEN & THEREFORE IMP❑SSIBLE <br />WORK. NOTIFY ENGINEER OF DEVIATIONS BEYOND SCOPE <br />TO ACCOUNT FOR. THIS DESIGN TAKES INTO CONSIDERATION <br />INTENT OF WORK AS SHOWN ON PLANS. NOTE 3 ABOVE. <br />THIS DIVERSITY. BY BIDDING THIS P❑RTI❑N OF WORK THE 11. <br />PIPING INVERTS SHALL BE REWORKED ON EXISTING TO MEET <br />PC CONTRACTOR ACCEPTS THIS RESPONSIBILITY AND IS <br />SLOPE OF PIPE REQUIRED FOR NEW WORK INSTALLATION. <br />ADVISED TO ADJUST AS REQUIRED TO FACILITATE DESIGN <br />INTENT BY, INCORPORATING ANY EXTRA FITTINGS, PIPING, 12. <br />ARCHITECTURAL FLOOR PLANS ARE TO BE USED IN THE <br />C❑NSUMABLES, LABOR, MTLS, ETC. AS REQUIRED DURING <br />EVENT OF FLOOR PLAN DISCREPANCIES. PLUMBER AND HIS <br />ESTIMATING. PROVIDE ENGINEER DETAILED SHOP DWGS THAT <br />ESTIMATOR ARE RESPONSIBLE FOR USING THEIR PLANS IN <br />CORRELATE PLANS, ESTIMATE & SHOP DRAWINGS BEFORE <br />CONJUNCTION WITH THE PLUMBING OVERLAY DESIGN TO <br />ANY WORK IS INSTALLED. SUBMIT SH❑P/FABRICATION <br />FACILITATE A VIABLE ESTIMATE AND WORKING PRODUCT. <br />COORDINATION DRAWINGS FOR ALL PIPING TO BE INSTALLED, <br />IT IS THE PLUMBING CONTRACTORS RESPONSIBILITY TO <br />SHOW HVAC, SPRINKLER, LIGHTS, STRUCTURE AND CLG. GRID. <br />INVESTIGATE ALL THE DOCUMENTS OF THE DRAWING SET <br />THE PLUMBING ENGINEERED PLANS RESERVES THE RIGHT TO <br />AND ACQUIRE THEM AT THEIR COST TO ACCOMPLISH THEIR <br />HAVE PIPE AND FITTINGS ADJUSTED TO ACCOMMODATE A <br />WORK. THE ARCHITECTURAL FLOOR PLAN SHALL BE USED <br />REASONABLE FIELD CONDITION WITH❑UT PENALTY OR AN <br />AS THE FLOOR PLAN OF RECORD, <br />EXTRA COST TO THE OWNER, THE ENGINEER OR OTHER(S) <br />IN THE ABSENCE OF DOCUMENTED C❑ORDINATION PLANS 13. <br />SCHEDULE 40 PVC CAN BE USED IN NON -PLENUM <br />REQUIRED BY THE PLUMBING CONTRACTOR. <br />AREAS. CAST IRON SHALL BE USED IN PLENUMS, <br />RATED WALLS, CAVITY OR WHERE DETERMINED NECESSARY <br />4. EQUIPMENT AND PIPING SHALL BE ON GRADE AS REQUIRED <br />BY CODE OFFICIALS. <br />& SECURED VIA PIPE, CLAMPS, DR❑P-IN ANCHORS, 14. <br />PC IS REQUIRED TO SUBMIT AS -BUILT INSTALLATION DWGS. <br />RACKED, OR PIPE HANGER METHOD. SEE SPECS. <br />TO CITY AS REQUIRED THRU THE PROCESS OF INSTALLATION <br />(NOT SHOWN) <br />OF HIS WORK. ALL SUBMITTAL DATA SHALL BE PROVIDED <br />5. WATER HAMMER/ARRESTORS SHALL BE INSTALLED WHERE <br />FOR EVERY MATERIAL, FIXTURE, DEVICE, ETC. FOR THE WORK <br />QUICK CL❑SING VALVES ARE UTILIZED. INSTALL PER <br />THE PC PLANS TO INSTALL. PC SHALL ALSO SUBMIT ANY <br />MANUFACTURES SPECIFICATIONS. (NOT SHOWN) <br />DATA TO CITY AS REQUIRED BY FIELD INSPECTOR. FIXTURES <br />IN THE FIXTURE SCHEDULE ARE A GUIDE ONLY. THE <br />DESIGNER SHALL NOT BE HELD LIABLE FOR ITEMS NOT <br />SUBMITTED THRU OUR OFFICE. <br />PLUMBING LEGEND <br />COLD WATER PIPING <br />HOT WATER PIPING <br />HOT WATER RETURN PIPING <br />WASTE PIPING <br />FM <br />ELEV. SUMP FORCE MAIN <br />- - - - - <br />VENT PIPING <br />Excw- <br />EXISTING COLD WATER PIPING <br />ExHw- <br />EXISTING HOT WATER PIPING <br />- ExHWR- <br />EXISTING HOT WATER RETURN PIPING <br />ExS <br />EXISTING WASTE PIPING <br />- -ExV- - <br />VENT PIPING <br />wV <br />COMBINATION WASTE/VENT <br />LINE (OVERSIZED) <br />GAS <br />GAS PIPING <br />AIR <br />AIR PIPING <br />FLOW DIRECTION <br />C.I.P. <br />CAST IRON PIPE <br />D.I.P. <br />DUCTILE IRON PIPE <br />'X1' <br />FIXTURE SYMBOL- <br />FC❑ <br />FLOOR CLEANOUT <br />WC❑ <br />WALL CLEANOUT <br />COG <br />CLEANOUT ON GRADE <br />AFG <br />ABOVE FINISH GRADE <br />AFF <br />ABOVE FINISH FLOOR <br />BFP <br />BACKFL❑W PREVENT❑R <br />RPZ <br />PRESSURE REDUCING ZONE VALVE <br />RPZBFP <br />PRESSURE REDUCING ZONE <br />BACK FLOW PREVENT❑R <br />DCV <br />DOUBLE CHECK VALVE <br />D4 <br />BALL/GATE VALVE <br />DK <br />GLOBE VALVE <br />N <br />CHECK VALVE <br />-- <br />WALL HYDRANT / HOSE BIBB <br />UNION <br />TRAP PRIMER <br />J � <br />EXISTING 4" SANITARY <br />P.C. TO VERIFY EXACT <br />L-OCAI I T\\I-ON-/INVRT 10P9 RIOR TO BID <br />EXISTING WATERBREAK <br />HEATER TO REMAIN ROOM <br />FCO <br />MECH. <br />ROOM <br />�110CONNECT EXISTING_ IY ONSITE SS 1 <br />r F <br />/ <br />/ <br />/ <br />/ <br />/ <br />I II\ oM I a I EX <br />WC1 II 111 I / <br />I LCW --------- <br />0 II I / <br />li o11L15J1 L2 i / I 3" <br />I L VTR <br />DRAW e <br />ROOM I // I // <br />EXISTING <br />CLOSET <br />112 I I \ 1 3 HW i w B l >' EX I / <br />n SEE SCHEDULE & SPECS. KEYED PLUMBING PLAN NOTES: 0 <br />#or X KEY NOTE DESIGNATION 1. P.C. TO VERIFY EXISTING SITE PRIOR TO PLACING BID; INTENT OF DESIGN IS TO <br />TIE INTO EXISTING 4' SANITARY UNE AND HOT/COLD WATER UNES FOR NEW SINKS <br />VTR VENT THRU ROOF & WATER COOLER. CUT AND PATCH EXISTING FLOOR AS REQUIRED FOR <br />INSTALLATION. P.C. TO VERIFY EXISTING SANITARY INVERT PRIOR TO DOING ANY <br />WORK ONSITE. VERIFY FALL FOR NEW WORK. <br />2. CONNECT TO EXISTING COLD WATER SUPPLY; COORDINATE WITH EXISTING <br />CONDITONS. <br />3. COORDINATE INSTALLATION OF NEW WATER HEATER; INTENT IS INSTALL ABOVE <br />LAG BEAM ANCHOR LAY -IN CEIUNG <br />4. UNDERGROUND SANITARY UNE; COORDINATE WITH EXISTING CONDITIONS; VERIFY <br />UNDERGROUND UTILITIES PRIOR TO INSTALLATION. <br />5. CONNECT ILL WC1 & WC2 TO EXISTING SANITARY AND WATER CONNECTIONS. <br />COORDINATE WITH EXISTING CONDITIONS. <br />6. P.C. TO REMOVE EXISTING MOP SINK AND REWORK EXISTING CW/HW, VENT, AND <br />SANITARY TO FEED NEW TYPE L1 HAND SINK. COORDINATE WITH EXISTING <br />CONDITIONS. <br />HORIZONTAL RACK <br />SYSTEM <br />PIPE/INSULATION <br />CLEVIS SHIELD REW MIN. 1' <br />HANGER VERTICAL PIPE <br />RISER CLAMP <br />• <br />ALUMINUM UNI-STRUT or CHANNEL <br />TYR HANGER/SUPPORT/ANCHOR DETAIL <br />NOT TO SCALE <br />FINISH GRADE <br />16'X16'X6' THICK <br />CONIC. PAD W/ <br />CHAMFERED EDGES <br />& BROOM FINISH <br />DRAIN PIPE <br />NOTE: <br />CONIC. PAD MAY BE <br />OMITTED IF CLEANOUT <br />IS SET IN CONCRETE <br />SURFACE. <br />TYR CLEANOUT <br />NOT TO SCALE <br />FINISH GRADE <br />-IIII-IIII-IIII > _•/ .: /, <br />CLEANOUT W/ BRONZE <br />THREADED PLUG, <br />J❑SAM 58470 <br />OR EQUAL <br />Ile <br />G <br />S C <br />� � L <br />i <br />i <br />/ -IIII �II•II Ifll- <br />' �' �' IIII-IIII-IIII- <br />12'X12'X4' THICK <br />CONC. PAD W/ <br />CHAMFERED EDGES <br />& BROOM FINISH <br />DRAIN PIPE <br />��,0 <br />NEW PARTIAL SANITARY ISOMETRIC RISER <br />NO SCALE <br />�L--- L cw <br />F_ - I - - <br />I I 01 I <br />I I L1 I <br />II / <br />I / 3/4'HW <br />93/4-CW <br />-X ISTING <br />1 ESTROOM 1 <br />113 1 0 <br />I WC2 o <br />II I <br />I_ <br />CORRIDOR <br />I 114 3 \ \ <br />II <br />II � <br />II <br />HW - <br />PROCESSING <br />I ROOM <br />II I/ <br />r <br />J/ 1 <br />if I <br />I I <br />\ L2 I EX <br />DRAW <br />I <br />\ ROOM <br />107 I <br />I <br />II /I <br />I / <br />DRAW <br />ROOM I / <br />I L2 <br />I/ <br />V <br />w <br />L2 <br />TEW <br />I I <br />� I <br />I <br />FAX <br />RECEPTION <br />102 <br />Ir DASHED DENOTES <br />EXISTING WALLS <br />WAITING <br />ROOM <br />101 <br />PPLY <br />DOM <br />04 <br />� I / <br />I / <br />II / <br />I I/ <br />i� <br />/II <br />SUPF 2ES <br />PLUMBING - <br />CW/HW, VENT & SANITARY - <br />SCALE vn• = i/-o• <br />o i z' a a <br />PLUMBING DEMOLITION NOTES <br />ALL PLUMBING FIXTURES WITH EXCEPTION OF ELECTRIC WATER COOLER ON CORNER OF EXISTING RESTROOM #111 TO REMAIN; CAP AND SEAL ALL PLUMBING <br />LINES INTO REMOVED EWC, E.C. TO LOCATE EXISTING SANITARY UNES AND COORDINATE CUTTING PATCHING OF THE FLOOR TO MINIMIZE IMPACT; ALL INVERT TO <br />BE CHECKED PRIOR TO STARTING WORK; G.C. TO PATCH AND REPAIR; P.C. TO THOROUGHLY REVIEW EXISTING CONDITIONS PRIOR TO PLACING BID. <br />Talmage R. Payne, <br />Architect <br />111 Paisley Street <br />Greensboro, NC <br />27401 <br />336. <br />378.1812 <br />378.1460 fax <br />STATE OF <br />;s:nl 0 R \0 <br />Charles B. Lackey, <br />Professional Engineer <br />1848 Banking St <br />Greensboro, NC 27408 <br />336.275-6360 <br />336.275-1996 fax <br />info@gsoengineering.com <br />E?:::� <br />O <br />c.> <br />a� <br />O E <br />O <br />c <br />0 <br />12 <br />O <br />O � <br />C') <br />QLft <br />�.o <br />cc <br />Jo <br />Q.n_��tiv n <br />Patient Service <br />Center <br />7348 Gall Blvd <br />Zephyrhills, FL <br />PLUMBING PLAN <br />PROJECT # <br />DATE: <br />DRAWN BY: <br />SCALE: <br />ISSUED FOR: <br />AS SHOWN <br />PERMITTING <br />TW*a ft is the p w" of PNP Deapn ftM and is not b be <br />mpied rW ai *& wiciie>pessed wfn cmwLC2013 <br />Pi 4r, <br />