DOOR SCHEDULE
<br />DOOR FRAME U.L. HARDWARE/REMARKS
<br />NO. WDT HGT THK MAT FIN TYPE MAT FIN LABEL
<br />( 1q) 3'-0- 7'-0" 1 3/4" INSUL PTD. A H.M. PTD. - KEYED LATCHSET, HINGE CLOSER, STOP
<br />\_! H.M.
<br />B PAIR 7'-0" 1 3/4" INSUL PTD. B H.M. PTD. _ PANIC HARDWARE W/ ALARM, CLOSER,
<br />3'-0" H.M. WEATHERSTRIPPING, THRESHOLD
<br />4'-0" 7'-0" 1 3/4" INSUML PTD. C H.M. PTD. - KEYED LATCHSET, HINGE CLOSER, STOP (GUN ROOM)
<br />INSUL PRE- SECTIONAL OVERHEAD DOOR, MANUALLY OPERABLE
<br />(U 8'-0" 10'-0" - SECTIONAL FINISHED D STL PTD. -
<br />STEEL WEATHERSTRIPPING
<br />PAIR INSUL PANIC HARDWARE W/ ALARM, CLOSER,
<br />E 3=_0" 8'-0" 1 3/4" H.M. PTD. E H.M. PTD. - WEATHERSTRIPPING, THRESHOLD
<br />INSUL PRE_ SECTIONAL OVERHEAD DOOR, MANUALLY OPERABLE
<br />10'-0" 10'-0" - SECTIONAL FINISHED F H.M. PTD. -
<br />STEEL WEATHERSTRIPPING
<br />PAIR �" ALUM. PRE- PANIC HARDWARE W ALARM, CLOSER, ' 3,_O" 7 -0 - GLASS FINISHED G ALUM. PTD. - WEATHERSTRIPPING, THRESHOLD
<br />CH
<br />PAIR INSUL
<br />) 2'-6" 7'-0" 1 3/4" H M MD. H PTD. - PASSAGE LATCHSET, HINGE CLOSER, STOP (MAIN ELECTRICAL ROOM)
<br />2'-10"
<br />(J )
<br />�1
<br />2'-6"
<br />7'-0"
<br />1 3/4"
<br />INSUL
<br />H.M.
<br />PID.
<br />J
<br />H.M.
<br />PTD.
<br />-
<br />KEYED LATCHSET, HINGE CLOSER, STOP
<br />( K }
<br />2'-8"
<br />7'-0"
<br />1 3/4"
<br />INSUL
<br />H.M.
<br />PTD.
<br />K
<br />H.M.
<br />PTD.
<br />-
<br />PASSAGE LATCHSET, HINGE CLOSER, STOP
<br />3•_0"
<br />71_0"
<br />1 3/4."
<br />I�L
<br />PTD.
<br />A
<br />H.M.
<br />PTD.
<br />-
<br />PASSAGE LATCHSET, HINGE CLOSER, STOP
<br />36"
<br />36" 36"
<br />I
<br />I`�
<br />\
<br />\
<br />I
<br />r-
<br />\
<br />\
<br />/
<br />/
<br />ALUM - CLEAR ANODIZED ALUMINUM
<br />H.M. - HOLLOW METAL DOORS (18 GA. FLUSH STEEL)
<br />HOLLOW METAL FRAMES (16 GA. STEEL)
<br />INSUL. - POLYSTYRENE INSULATED, U VALUE _ .15
<br />GLASS - GLASS, CLEAR, SAFETY GLASS WHERE REQUIRED
<br />PTD. - PAINTED
<br />SCWD - SOLID CORE WOOD
<br />STL - STEEL
<br />10
<br />t
<br />\
<br />t
<br />\
<br />t
<br />\
<br />\00
<br />t
<br />t
<br />BUILDING CODE REQUIREMENTS
<br />1.
<br />EXISTING BUILDING IS CURRENTLY VACANT AND THE PREVIOUS TENANT WAS K-MART.
<br />2.
<br />USE AND OCCUPANCY CLASSIFICATION
<br />THE PROPOSED BUILDING MODIFICATIONS WILL NOT RESULT IN A CHANGE OF USE.
<br />EXISTING BUILDING USE GROUP = "M" MERCANTILE (PREVIOUS TENANT K-MART)
<br />PROPOSED BUILDING USE GROUP = "M" MERCANTILE (RURAL KING FARM AND HOME STORE)
<br />3.
<br />TYPE OF CONSTRUCTION
<br />EXISTING BUILDING - 118 (28) - NON-COMBUSTIBLE, UNPROTECTED
<br />THE PROPOSED INTERIOR IMPROVEMENTS WILL NOT ALTER THE EXISTING BUILDING'S TYPE 11 B CONSTRUCTION CLASSIFICATION AND ALL INDICATED
<br />CONSTRUCTION WILL BE CONSISTENT WITH TYPE
<br />118 CONSTRUCTION STANDARDS AND REQUIREMENTS.
<br />4.
<br />FIRE RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (TABLE)
<br />BUILDING ELEMENTS FIRE RATING
<br />PRIMARY STRUCTURAL FRAME NONE REQUIRED
<br />BEARING WALLS (EXTERIOR) NONE REQUIRED
<br />BEARING WALLS (INTERIOR) NONE REQUIRED
<br />NONBEARING WALLS AND PARTITIONS (EXTERIOR) NONE REQUIRED
<br />NONBEARING WALLS AND PARTITIONS (INTERIOR) NONE REQUIRED
<br />FLOOR CONSTRUCTION AND SECONDARY MEMBERS NONE REQUIRED
<br />ROOF CONSTRUCTION AND SECONDARY MEMBERS NONE REQUIRED
<br />5.
<br />FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
<br />0-HR FIRE RESISTANCE RATING WITH GREATER THAN, OR EQUAL TO, 10 FEET FIRE SEPARATION DISTANCE.
<br />6.
<br />MAXIMUM AREA OF EXTERIOR WALL OPENINGS
<br />MAXIMUM AREA OF EXTERIOR WALL OPENINGS NOT REQUIRED FOR UNPROTECTED, SPRINKLERED BUILDINGS WITH FIRE SEPARATION DISTANCES OF
<br />30 FEET OR GREATER.
<br />7.
<br />FIREBLOCKING
<br />NOT REQUIRED FOR NON-COMBUSTIBLE CONSTRUCTION.
<br />8.
<br />VENTILATION
<br />OUTSIDE AIR VENTILATION PROVIDED PER MECHANICAL CODE. ALL EXISTING AIR VENTILATION IS SCHEDULED TO REMAIN. THE SYSTEM SHALL BE
<br />RE -BALANCED PRIOR TO RECEIVING FINAL
<br />OCCUPANCY PERMIT.
<br />A NEW 18" VENT FAN SHALL BE PROVIDED AT THE NEW MERCHANDISE ASSEMBLY SHOP, REFER TO EXISTING/PROPOSED PLAN ON DRAWING Al.
<br />9.
<br />INTERIOR WALL AND CEILING FINISHES
<br />CLASS A: FLAME SPREAD 0-25, SMOKE DEVELOPED 0-450
<br />CLASS B: FLAME SPREAD 26-75, SMOKE DEVELOPED 0-450
<br />CLASS C: FLAME SPREAD 76-200, SMOKE DEVELOPED 0-450
<br />SPRINKLERED BUILDING
<br />GROUP EXIT ENCLOSURES AND EXIT PASSAGEWAYS CORRIDORS ROOMS AND ENCLOSED SPACES
<br />GROUP M CLASS B CLASS C CLASS C
<br />10.
<br />INTERIOR FLOOR FINISHES (804.1 Z 804.4V -
<br />INTERIOR FLOOR FINISHES IN EXIT ENCLOSURES, EXIT PASSAGEWAYS, CORRIDORS, AND ROOMS OR SPACES NOT SEPARATED FROM CORRIDORS BY
<br />FULL HEIGHT PARTITIONS SHALL NOT BE LESS
<br />THAN CLASS 11 AS IS REQUIRED FOR USE GROUP W. IN ALL AREAS, FLOOR FINISHES SHALL COMPLY WITH THE DOCFF-1 'PILL TEST' (CPSC 16CFR,
<br />PART 1630). FLOOR FINISHES AND
<br />COVERINGS OF A TRADITIONAL TYPE, SUCH AS WOOD, VINYL, LINOLEUM, OR TERRAZZO, AND RESILIENT FLOOR COVERING MATERIALS THAT ARE NOT COMPOSED OF FIBERS ARE EXEMPT FROM
<br />THESE REQUIREMENTS.
<br />FENCED DISPLAY (OUTSIDE) = 7,780 SQ.FT.
<br />GENERAL NOTES
<br />1. - CONTRACTOR SHALL PROVIDE A DETAILED HARDWARE SCHEDULE FOR OWNER'S APPROVAL PRIOR TO ORDERING. (POST LOCK)
<br />2. - GLAZING IN ALL DOORS SHALL BE SAFETY GLASS.
<br />3. - ALL EMERGENCY EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE MADE WITHOUT
<br />THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
<br />4. - ALL DOOR HARDWARE SHALL INCLUDE LEVER OPERATED MECHANISMS.
<br />5. - PROVIDE MASTER KEYS PER OWNERS INSTRUCTIONS:
<br />A. FRONT DOORS - 1 KEY 10' COPIES (MUST HAVE AN INTERNAL THUMB LOCK TO MEET FIRE CODE) (IF STORE HAS DETEX
<br />PANIC HARDWARE, THESE DOORS WOULD BE KEYED THE SAME AS THE FRONT ENTRY AND EXIT)
<br />B. CASH OFFICE AND HR OFFICE - 1 KEY 10 COPIES
<br />C. ALL OTHER OFFICE DOORS - 1 KEY 10 COPIES
<br />6. - EXTERIOR HOLLOW METAL DOORS SHALL HAVE HANDICAP TYPE ALUMINUM THRESHOLDS (HAGER 520S OR EQUAL).
<br />7. - ALL DOUBLE DOORS SHALL HAVE MANUAL BOLTS ON EITHER LEAF DOOR.
<br />8. - ALL EXIT DOORS NEED PANIC DETEX HARDWARE FOR ALARMS WHEN USED. THERE SHOULD BE A REMOTE SPEAKER MOUNTED
<br />ON THE SALES FLOOR SIDE OF WALL FROM THE DOOR SO THE STORE ASSOCIATES CAN HEAR THE ALARM.
<br />9. GENERAL CONTRACTOR TO BUILD ITEMS
<br />A. 3 BINS FOR DOG TREATS 42"x48"
<br />B. 1 BIN FOR GRASS SEED 24"x96"
<br />C. 1 BIN FOR BIRD SEED 24"x96"
<br />D. 1 POTATO BIN STAINED WITH MINWAX SPECIAL WALNUT 42"x96"x38", 3 BINS ON TOP AND BOTTOM FOR PRODUCT
<br />E. 1 ONION BIN STAINED WITH MINWAX SPECIAL WALNUT 42"x96"08", 3 BINS ON TOP AND BOTTOM FOR PRODUCT -USE"
<br />HARDWARE CLOTH ON TOP FOR ONION BINS ONLY.
<br />ELECTRICAL NOTES
<br />1. ALL MATERIAL AND EQUIPMENT SHALL CONFORM TO THE FOLLOWING STANDARDS WHERE APPLICABLE; NATIONAL ELECTRICAL CODE (N.E.C.),
<br />UNDERWRITERS LABORATORIES (U.L), AND NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (N.E.M.A.).
<br />2. ALL INTERIOR AND EXTERIOR ELECTRICAL WORK SHALL BE DONE BY A ELECTRICAL CONTRACTOR LICENSED IN FLORIDA AND DONE IN ACCORDANCE
<br />WITH THE CURRENT ELECTRICAL CODES. CONTRACTOR SHALL CALL FOR A INSPECTIONS WHEN WORK IS COMPLETE.
<br />3. ALL WIRING SHALL BE COPPER AND INSTALLED IN CONDUIT WHERE REQUIRED BY CODE. COPPER WIRING SHALL BE A MINIMUM OF #12 AWG AND
<br />RATED AT 600 VOLTS.
<br />4. WIRE SIZES FROM #12 TO 3/0 SHALL BE THHN-THWN, AND WIRE LARGER THAN 3/0 SHALL BE THW.
<br />5. VERIFY DISCONNECT FOR BALER IS EXISTING AT THE RIGHT LOCATION, IS THE CORRECT SIZE DISCONNECT WITH THE CORRECT WIRE SIZE IN
<br />CONDUIT.
<br />6. PROVIDE CONDUIT FOR TELEPHONE LINES, DATA WIRING AND EQUIPMENT HOOK-UPS AS REQUIRED.
<br />7. ALL PANELBOARDS SHALL BE PROVIDED WITH A TYPEWRITTEN DIRECTORY.
<br />8. A. DROPS TO NEW CHECKOUT COUNTERS(6) AND SERVICE COUNTERS(3) EACH WITH A CONDUIT FOR HIGH VOLTAGE AND ONE FOR DATA.
<br />B. GC TO INSTALL ALL ELECTRICAL DROPS PER FIXTURE PLAN USING EXISTING CIRCUITS NEAREST LOCATION. TREAT AS A DESIGN BUILD FOR
<br />MINOR EC SCOPE OF WORK WITH APPROXIMATELY 35 DROPS. (DRAWING A6)
<br />9. EXTERIOR LIGHTING - BY OWNER
<br />10. INTERIOR LIGHTING - BY OWNER
<br />A. REPLACE ALL LAMPS WITH RURAL KING PROVIDED LED LAMPS. BYPASS BALLASTS VIA WIRING MODIFICATION.
<br />B. REMOVE ALL AUTO (MOTION) SENSORS
<br />C. INSTALL NEW LIGHT SWITCHES TO CONTROL ENTIRE SALES FLOOR FROM ONE AREA AT FRONT ENTRANCE OF STORE.
<br />D. INSTALL NEW LIGHT SWITCHES TO CONTROL ALL AREAS OF WAREHOUSE FROM ONE SPOT NEAR ENTRANCE OF WAREHOUSE.
<br />11. ALL HVAC SYSTEMS BY OWNER
<br />12. GC TO INSTALL LOCK BOXES AROUND THERMOSTATS AND GIVE STORE MANAGER THE KEYS AND ALL KEYS TO BUILDING WHEN
<br />CORES COMPLETED.
<br />I MECHANICAL NOTES I
<br />1. EXHAUST FAN
<br />A. INSTALL NEW 18" EXHAUST FAN WITH 1 HR TIMER SWITCH WITH TRU WALL MOUNT IF ON PERIMETER WALL AND BACKDRAF17 DAMPER.
<br />2. FIRE SPRINKLER SYSTEM
<br />A. AN FLORIDA LICENSED SPRINKLER CONTRACTOR SHALL HYDROTEST AND VERIFY THAT THE INSPECTION CERTIFICATES ARE CURRENT
<br />PRIOR TO THE OPENING OF THE STORE.
<br />OWNER PROVIDED ITEMS
<br />1. CHECKING AND SERVICE COUNTERS ADA APPROVED. (DRAWING A3)
<br />2. BALER INCLUDING THE INSTALLATION.
<br />3. SALES FLOOR LIGHTING FIXTURES AND LAMPS, EXCEPT FOR SURFACE MOUNTED FIXTURES IN OFFICES AND REST/ROOMS.
<br />OWNER'S NATIONAL ACCOUNTS
<br />1. DOOR HARDWARE POST LOCK
<br />2. FRONT ENTRY DOOR RECORD
<br />3. HVAC YORK (IF APPLICABLE)
<br />4. BALER PTR BALER AND COMPACTOR CO.
<br />DOOR SCHEDULE
<br />MECHANICAL & ELECTRICAL NOTES
<br />mmlddftAdo"
<br />Rural Kigg
<br />Anwicsys Fam & Ham Store
<br />�ggggD0�66UB
<br />®�° RURAL KING
<br />°®
<br />` G �� : ZEPHYRHILLS STORE
<br />No,571; 7422 GALL BOULEVARD
<br />® 4 ZEPHYRHILLS, FLORIDA 33541
<br />aTc o� ...�. ALLEY ENGINEERING�.
<br />°® 0� `° ®�° AEC C 0 R P 0 R A T 1 0 N
<br />a
<br />g NAe©�x�.,
<br />p ®9ae®gig®aeo 3848 EAST FULTON AVENUE DECATUR, IWNOIS 62521
<br />FEB - FEB 2 $Zoe% (217) 428-0566 FAX (217) 428-984.4
<br />DRWG BY: CHWD BY: PROJ. N0: DRWG NO:
<br />T6si
<br />-PRELIMINARY IWX
<br />
|