Laserfiche WebLink
40l=III Ih mii 111E I.:���-11 ••r � JittiWi4�J._. L1.i4A= j...a . li.. _ 1. � _ <br />GENERAL NOTES <br />1. ALL APPLICABLE PERMITS SHALL BE OBTAINED PRIOR TO STARTING WORK. <br />2. WORK SHALL COMPLY WITH ALL APPLICABLE CODES. <br />3. RECORD DRAWINGS (AS -BUILT) SHALL BE ACCURATELY MAINTAINED AND <br />FORWARDED TO THE APPROPRIATE PARTY UPON COMPLETION OF PROJECT. <br />4. POWER (120VAC) TO ALL FIRE ALARM AND SECURITY PANELS SHALL BE <br />SUPPLIED FROM DEDICATED, UNSWITCHED AND CLEARLY IDENTIFIABLE <br />SOURCES. <br />5. ALL DOORS WHICH ARE CONTROLLED BY ELECTRONIC LOCKING DEVICES <br />SHALL BE CONFIGURED TO MEET ALL CODES. <br />6. ALL DEVICES EITHER INSTALLED WITHIN THE SCOPE OF THIS PROJECT OR <br />EFFECTED BY THIS PROJECT SHALL BE TESTED. <br />7. ALL CABLE SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS <br />INSTALLED. <br />8. ALL WORK SHALL BE PERFORMED IN A PROFESSIONAL MANNER. <br />9. AREAS EFFECTED BY THE SCOPE OF THIS PROJECT SHALL BE KEPT CLEAN <br />AND TRASH REMOVED DAILY. <br />QTY. <br />1 <br />1 <br />2 <br />2 <br />1 <br />IN <br />QTY. <br />1 <br />4 <br />QTY. <br />1 <br />1 <br />28 <br />QTY. <br />1 <br />1 <br />1 <br />2 <br />0 <br />2 <br />12 <br />2 <br />0 <br />QTY. <br />3 <br />1 <br />1 <br />2 <br />0 <br />RIONICS COVER SHEET <br />- NOT ALL DEVICES DISPLAYED ON THIS LEGEND APPEAR ON DRAWINGS - <br />INTRUSION (BURGLAR) ALARM (ES) DEVICES <br />SYMBOL <br />DEVICE DESCRIPTION <br />© <br />BURGLAR ALARM CONTROL PANEL <br />FK_Pj <br />KEYPAD (ALPHANUMERIC) USE 18-04 OAS Cable <br />❑O <br />SIREN/SOUNDER / EXTERIOR HORN/STROBE ALARM NOTIFICATION USE 18-04 OAS Cable <br />Oc <br />DOOR CONTACT <br />MOTION DETECTOR (Wide angle) <br />0 <br />WIRELESS REPEATER <br />ACCESS CONTROL (ES) DEVICES <br />SYMBOL <br />DEVICE DESCRIPTION <br />Fc-Ac-P-1 <br />_ <br />ACCESS CONTROL PANEL <br />rK-1 <br />KEYPAD USE 18-04 OAS & 18-04 OAS DIRECT BURIAL Cable <br />Oxx <br />GATE OVERIDE SWITCH <br />BACKGROUND MUSIC (BM) DEVICES <br />SYMBOL <br />DEVICE DESCRIPTION <br />AMP 1 <br />60 WATT AMPLIFIER WITH AM/FM/CD WITH AUX INPUT AND PAGING <br />F-MI-cl <br />DESK TOP MICROPHONE <br />OOa CM <br />SWAY SPEAKER, CEILING MOUNTED USE 18-02 OAS Cable <br />CLOSED CIRCUIT TELEVISION (ES) DEVICES <br />SYMBOL <br />DEVICE DESCRIPTION <br />NVR <br />NETWORK VIDEO RECORDER <br />FP-o-El <br />POE NETWORK SWITCH - PORT AMOUNT AS NOTED <br />uPs <br />UNINTERRUPTED POWER SUPPLY / BATTERY BACK UP <br />o <br />CCTV MONITOR <br />•" <br />CAMERA (FIXED) USE 24-4P C5E Cable <br />��Dual <br />CAMERA (Dual Lens) USE 24-4P C5E Cable <br />OMD <br />CAMERA (MINI -DOME) (Vari = VARIFOCAL LENS) USE 24-4P C5E Cable <br />Q <br />120VAC/20A DEDICATED UNSWITCHED DUPLEX RECEPTACLE (BY OTHER) <br />wAP <br />WIRELESS ACCESS POINT (POC TO CUSTOMER PROVIDED WAP) <br />CABLING <br />PART # <br />DEVICE DESCRIPTION <br />414104 <br />18-02 <br />OAS <br />STIR <br />CMR Org Stp <br />(Background Music) <br />1000FT <br />BOX <br />414302 <br />18-04 <br />OAS <br />STIR <br />CMR Blu Stp <br />(Access)(Intrusion) <br />1000FT <br />BOX <br />71431 CVNQ <br />18-04 <br />OAS <br />STIR <br />DB TC Quad <br />(Access DB) <br />1000FT <br />BOX <br />8665610-10 <br />24-4P <br />UNS <br />SOL <br />CMR C5E Wht Jkt (CCTV) <br />1000FT <br />BOX <br />665610-110DB <br />24-4P <br />UNS <br />SOL <br />PE C5E Blk <br />DB (CCTV DB) <br />1000FT <br />BOX <br />NOTE: DB = DIRECT BURIAL CABLE <br />SHEET NAMING CONVENTION <br />SHEET SHEET DESCRIPTION <br />CS 1 .01 <br />COVER SHEET(S) & NOTES <br />ES <br />ELECTRONIC SECURITY SYSTEMS <br />FA - <br />FIRE ALARM SYSTEMS <br />1.01 <br />FLOOR PLANS / DEVICE LOCATION DRAWINGS <br />2.01 <br />RISER DIAGRAM DRAWINGS <br />3.01 <br />PRODUCT TYPICAL DRAWINGS <br />4.01 <br />DEVICE DETAIL DRAWINGS <br />5.01 <br />POWER CALCULATION SHEETS <br />6.01 <br />PRODUCT DATA SHEETS <br />7.01 <br />SEQUENCE OF OPERATIONS MATRIX & GRAPHIC ANNUNCIATOR <br />IDENTIFIERS <br />TYPE <br />DEVICE DESCRIPTION <br />RNx <br />xxxx <br />POINT <br />OF PROTECTION IDENTIFIER / TYPE REFERENCE <br />0P1-3.2 <br />POWER <br />SUPPLY #1 / CIRCUIT 3 / SECOND DEVICE IN LINE <br />001-003 <br />LOOP #1 / DEVICE #3 <br />CABLE <br />ID - SEE "CABLE LEGEND" FOR MORE INFORMATION <br />A,B,c <br />A-1.0 <br />SHEET <br />ID - SHEET DETAIL "A", "B", "C" / SHEET # FA-1.01 <br />CABLE LEGEND <br />ID AWG COND SHIELD CLASS* <br />A <br />18 <br />2 <br />N <br />FPLP <br />B <br />C <br />18 <br />18 <br />2 <br />4 <br />Y <br />N <br />FPLP <br />FPLP <br />D <br />16 <br />2 <br />N <br />FPLP <br />E <br />16 <br />2 <br />Y <br />FPLP <br />F <br />16 <br />4 <br />N <br />FPLP <br />G <br />14 <br />2 <br />N <br />FPLP <br />H <br />14 <br />4 <br />N <br />FPLP <br />1 <br />12 <br />2 <br />N <br />FPLP <br />J <br />12 <br />4 <br />N <br />FPLP <br />K <br />24 <br />2 <br />Y <br />CL2P <br />L <br />22 <br />2 <br />N <br />CL2P <br />M <br />22 <br />4 <br />N <br />CL2P <br />N <br />22 <br />4 <br />Y <br />CL2P <br />0 <br />22 <br />4 <br />Y** <br />CL2P <br />P <br />22 <br />10 <br />N <br />CL2P <br />Q <br />18 <br />2 <br />N <br />CL2P <br />R <br />18 <br />2 <br />Y <br />CL2P <br />S <br />18 <br />4 <br />N <br />CL2P <br />T <br />18 <br />4 <br />Y <br />CL2P <br />U <br />18 <br />6 <br />Y <br />CL2P <br />V <br />18 <br />8 <br />Y <br />CL2P <br />* SEE GENERAL NOTE #7 <br />SHEET INDEX <br />ID AWG COND SHIELD CLASS* <br />W <br />18 <br />10 <br />N <br />CL2P <br />Z <br />18 <br />12 <br />Y <br />CL2P <br />Y <br />16 <br />2 <br />N <br />CL2P <br />Z <br />16 <br />2 <br />Y <br />CL2P <br />AA <br />16 <br />4 <br />N <br />CL2P <br />BB <br />16 <br />4 <br />Y** <br />CL2P <br />CC <br />16/19 <br />4 <br />N <br />CL2P <br />DID <br />14 <br />2 <br />N <br />CL2P <br />EE <br />14 <br />1 <br />N <br />CL2 <br />FF <br />RG59 <br />N <br />CL2P <br />GG <br />RG59 & 18/2 <br />N <br />CL2P <br />HH <br />RG6 <br />N <br />CL2P <br />II <br />CAT5e <br />N <br />CL2P <br />JJ <br />CAT6 <br />N <br />CL2P <br />KK <br />PATCH -CABLE <br />COPPER <br />LL <br />62.5/125um <br />MULTI MODE <br />MM <br />9/125um <br />SINGLE MODE <br />NN <br />PATCH -CABLE <br />FIBER-OPTIC <br />00 <br />PP <br />QQ <br />RR <br />** 2 PAIR - EACH PAIR WITH <br />INDIVIDUAL SHIELD <br />SHEET DESCRIPTION <br />CS1.01 <br />COVER SHEET, LEGENDS AND GENERAL NOTES <br />SEC1.01 <br />SITE SECURITY PLAN <br />SEC1.02 <br />FIRST FLOOR PLAN <br />SEC2.01 <br />SECOND FLOOR SECURITY PLAN <br />SEC3.01 <br />THIRD FLOOR SECURITY PLAN <br />aid <br />z °d <br />A9 U <br />T <br />U. <br />N coo <br />o - oQ <br />� �J 3:�r QU< <br />z <br />1�5 <br />`i_� <br />5lq <br />Y� <br />ATTENTION: <br />THESE DRAWINGS MAY CONTAIN CONFIDENTIAL <br />INFORMATION AND SHOULD NOT BE DISTRIBUTED <br />DRAWING ACCEPTANCE: <br />IT IS THE RESPONSIBILITY OF THE LOCAL <br />Rionics SALES & SERVICE OFFICE (SSO) TO <br />REVIEW THE CONTENT OF THESE DRAWINGS <br />FOR ACCURACY AND COMPLIANCE WITH LOCAL <br />AND STATE CODES PRIOR TO RELEASING THEM <br />TO THE FIELD. <br />RECORD DRAWINGS: <br />ALL WORK PERFORMED IN THE FIELD SHALL BE <br />ACCURATELY RECORDED ON THESE DRAWINGS <br />AND RETURNED TO THE MAIN OFFICE CAD <br />DEPARTMENT AT: <br />RIONICS, LLC <br />2700 BRASELTON HWY. STE# 10-388 <br />DACULA, GA, 30019 <br />ATTN: AS-BUILTS <br />NICET REVIEW PERFORMED BY: <br />NAME: <br />SIGNATURE: <br />NICET #: <br />RELEASE / REVISION LOG <br />NO. DATE INT. DESCRIPTION <br />R <br />k <br />WnF <br />Q <br />CC <br />C <br />y <br />0 <br />N <br />0 <br />J <br />� <br />c <br />_CDco <br />�$ <br />, <br />a N <br />CO co <br />o�alev <br />a if iWk <br />4. <br />C O Al <br />�ZaL. <br />y <br />J <br />LL <br />PROJECT NORTH <br />0 <br />CUSTOMER <br />Flagship General Contractor, LLC. <br />Zephyrhills Self Storage <br />7519 Gall Boulevard <br />Zephyrhills, FL 33541 <br />DRAWN BY CHECKED BY RELEASE <br />SL GJ <br />SHEET TITLE <br />Rionics <br />COVER <br />SHEET <br />This design including specifications, drawings, and design concepts is the property of Rionics, LLC., and is furnished on a confidential basis, with the expressed understanding that it will not be sold, transfered, copied, or used to the detriment of Rionics without written permission. The recipient further agrees not to disclose the contents to any other party except for the specific purpose contracted for with Rionics. Rionics makes no representations as to the operability or accuracy of any systems, subsystems, assemblies, or other information contained herein unless specifically identified for Construction. <br />DATE I REF <br />4/1/24 1 - <br />SCALE SHEET <br />AS NOTED <br />CS-01 <br />