Laserfiche WebLink
} <br />m <br />City of Zephyrhills 5ec. 7.OG.04.03 Irrigation Design Standards <br />A. In -ground irrigation systems shall be utilized for new development including commercial development <br />and single and multi -family lots. Irrigation shall be provided for all proposed landscape material. <br />B. The Florida Irrigation Society (PIS) Standards, which is incorporated herein by reference, should be used <br />for all irrigation design and installation procedures, except where the requirements of this Ordinance <br />supersede the F15 standards. <br />C. An irrigation site plan, drawn at a readable scale, shall be submitted illustrating the proposed irrigation <br />zones, delineating micro -irrigation zones and areas utilizing all other irrigation techniques. The plan <br />should indicate the irrigation water source. Existing development with newly irrigated landscape and turf <br />areas shall not be required to submit an irrigation plan. <br />D. Where available, reclaimed wastewater shall be used for landscape irrigation and shall comply with the <br />requirements of this Section. <br />E. The irrigation system shall be designed to accommodate separate landscape plant zones based on <br />differing water requirements. Turf areas shall be on separate irrigation zones from other landscape plant <br />zones. <br />F. 5prinkler spacing shall not exceed fifty-five percent (55%) of the sprinklers' diameter of coverage. <br />G. Sprays and rotors shall have matching application rates within each irrigation zone. 5pray5 and rotors <br />shall not be combined on the same irrigation zone. <br />H. All irrigation systems shall be designed to avoid overspray, runoff or other similar conditions where water <br />flows onto or over adjacent property, non -irrigated areas, walkways, roadways, structures, or water <br />features. Narrow areas (four feet wide or less) shall be irrigated with micro -irrigation only. <br />I. Irrigation control equipment shall include an operable and functioning automatic irrigation controller <br />having program flexibility such as repeat cycles and multiple program capabilities. Automatic irrigation <br />controllers) shall have a battery back-up to retain the irrigation programs. Automatic control systems <br />shall be equipped with operable and functioning rain and wind sensor devices. These devices shall be <br />placed in areas where they can be exposed to natural rainfall and winds. As the technology improves, <br />moisture sensing devices to cut-off irrigation when ground conditions do not warrant watering are <br />encouraged. <br />I The irrigation system shall be maintained and managed to ensure efficient water use and to prevent <br />wasteful practices. These include, but are not limited to, resetting the automatic controller according to <br />season, cleaning irrigation filters, testing the rain and wind sensors, monitoring, adjusting and repairing <br />the irrigation equipment to ensure the efficiency of the system is maintained, replenishing mulch, utilizing <br />turf and landscape best management practices, including plant pruning and cutting grass around <br />sprinkler heads. <br />K. A registered landscape architect or irrigation contractor shall conduct a final field inspection of the <br />irrigation system. A certificate of compliance with the requirements of this article shall be provided to the <br />City of Zephyrhills and the property owner and an "as built" drawing of the irrigation system shall be <br />provided to the property owner and City of Zephyrhills prior to obtaining the certificate of occupancy <br />0 <br />NOTES: <br />I . THE DE51GN OF THE IRRIGATION <br />5Y5TEM FOR THIS, PROJECT 15 BASED <br />ON THE PRINCIPALS OF A <br />LOW -VOLUME, WATER CONSERVING, <br />AND WATER-W15E USAGE SYSTEM IN <br />FULL CONFORMANCE WITH THE <br />REQUIREMENTS AND STANDARDS 5ET <br />FORTH IN THE FLORIDA I RRI GATI O N <br />50CIETY MANUAL, 5TH EDITION, DATED <br />DECEMBER 1, 2005. <br />2. MATERIALS AND EQUIPMENT OF EQUAL <br />TO OR BETTER THAN MAY BE <br />5UB5TITUTED PROVIDED THE <br />RECOMMENDED MANUFACTURERS <br />SPECIFICATIONS ARE MET FOR <br />QUALITY, PERFORMANCE, INSTALLATION <br />AND WARRANTY, ETC. PROVIDED THE <br />DE51GN INTENT OF THE IRRIGATION <br />PLANS REMAIN IN FULL COMPLIANCE <br />WITH THE AFOREMENTIONED FLORIDA <br />IRRIGATION 50CIETY STANDARDS AND <br />5PECIFICATION5 <br />IRRIGATION SCHEDULE <br />SYMBOL MAN UFACTURER/MODEUDESCKIPTION <br />♦ e 0 & 0 Hunter PR05-OG-CV 5' strip -pray <br />ES La RCS a SS Turf Spray, G" popup, with check valve <br />S Hunter AFB <br />AFB Adju5table Flow Bubbler, 1 /2" F1PT, 5tainle55 steel screw <br />adIUu5tment. <br />SYMBOL MAN UFACTUKER/MODEUDEBCKIPTION <br />IS <br />Hunter ICV-A5 <br />Electric Remote Control Valve, plastic, with globe valve, <br />Accu-Bet pressure regulator. <br />© <br />Hunter PC-900 <br />Electromechanical Controller, 9 stations, outdoor model <br />® <br />Hunter RAIN-CLIK <br />Rain Sensor, with conduit Installation, mount a5 noted <br />FBTI <br />Wilkins 950XL 3/4" <br />Double Check Valve A55embly <br />❑M <br />Water Meter 3/4" <br />Irrigation Lateral Line: PVC Cla55 200 <br />Only lateral transition pipe sizes 3/4" and above are <br />Indicated on the plan, with all others being 1 /2" in size. <br />Irrigation Mainline: PVC Schedule 40 <br />...,,.... <br />Pipe 5leeve: PVC Schedule 40 <br />Typical pipe 5leeve for irrigation pipe. Pipe 51eeve 5IZe shall <br />be 2x pipe Size and allow for irrigation piping and their <br />related couplings to easily 511de through 5leeving material. <br />Extend sleeves 16 inches beyond edges of paving or <br />construction. <br />Valve Callout <br />Valve Number <br /># <br />#� Valve GPM <br /># <br /># Application Rate <br />Valve 51ze <br />QTY <br />46 <br />00 <br />QTY <br />G <br />1 <br />1,377 Lf. <br />507 Lf. <br />56 Lf. <br />.IV <br />E'I'• <br />48 HOURS BEFORE YOU DIG <br />CALL 5UNSt11NE <br />1-800-432-4770 <br />175 THE LAW IN FLORJDA <br />FL 5TATUE 553.851 (1 979) REQUIRES <br />MIN. OF 2 DAYS AND MAX. OF 5 DAY5 <br />NOTICE BEFORE YOU EXCAVATE, <br />FDOT MAINTENANCE YARD TO BE <br />CONTACTED 72 HOURS PRIOR TO <br />BEGINNING CONSTRUCTION. <br />¢W>—W-OZW <br />O Q T <br />N W O <br />CZ C7 a- O <br />_11 r cn z 2 <br />Z < cc <br />Lii CD <br />U Cc It Cr N Q <br />cn ❑ a a ❑ <br />a <br />W <br />N <br />2 <br />O <br />Z <br />Z <br />O <br />cc <br />U <br />LU <br />0 <br />LU <br />Q <br />0 <br />wl <br />d <br />W <br />Q OQ <br />N mZ <br />Z �� o liJ 06w o <br />LU LU Ir OIL <br />z w L9aoL6 <br />Z U ❑ Ir <br />LL_ cn W 0 <br />CC <br />W i.- CO <br />w Z M <br />m ❑ W - <br />❑� <br />O�� QQ o <br />> >_ U <br />8 ca <br />0 <br />Z <br />0 <br />0 <br />WQ <br />~o U)o <br />Cl 0 � <br />Q OJ M w <br />Oil wCID� <br />- CC) co 0 <br />W ED N <br />cc¢ � .0 <br />= r W N Q <br />CC)aZtic� <br />O <br />Maw _¢> <br />N a C'M d LL_ Q <br />o o Z W cn 0' w <br />ZZ0 WZC3 <br />U <br />wzZ � UF <br />LU Q W—> <br />cc:U�a0—nZ o C5 —1 <br />W Z Z Q < <br />J J Q Q Z <br />j W W <br />~ CL M <br />U U Q Z <br />U <br />LLQ <br />Q <br />~ JZ <br />W <br />W <br />— a <br />W <br />N <br />0 20' 40' 60' S <br />H <br />E <br />Scale: 111 = 20i T <br />IR1 <br />01 <br />Y <br />North <br />