Laserfiche WebLink
REFRIGERATED CASE SCHEDULE <br />SHEET NOTES <br />DEMO O NOTES <br />CASE LENGTH OR <br />FINAL <br />FSE NO. <br />QTY <br />DOOR NO <br />DESCRIPTION <br />MANUFACTURER <br />MODEL <br />SUPPLIED BY <br />INSTALLED BY <br />CONNECT <br />NOTES <br />1. THE QUANTITIES (COUNT) OF ITEMS <br />PURCHASED BY OWNER AS SCHEDULED ON <br />THIS "OWNER SUPPLIED MATERIALS AND <br />RD8022.145 <br />1 <br />3DR <br />REACH -IN (SELF-CONTAINED) <br />HUSSMANN <br />RFL <br />OWNER <br />RC <br />RC <br />5 <br />1. <br />SALES FLOOR TO BE ACCESSIBLE TO CUSTOMERS <br />RD8022.145 <br />1 <br />4DR <br />REACH -IN (SELF-CONTAINED) <br />HUSSMANN <br />RFL <br />OWNER <br />RC <br />RC <br />5 <br />OWNER SUPPLIED ITEMS" SCHEDULES, MAY <br />DURING NON -CONSTRUCTION HOURS. REMOVE <br />M I SC GROCERY EQUIPMENT LEGEND <br />QUANT TY REQUIR D TO COMPLETE THE REPRESENT THE <br />WIDTH CUSTOMER CURCULATION OR CCESSNSTRUCTION FENCING AND DUST WALLS INTERFERING <br />WITH <br />SCOPE OF WORK INCLUDED IN THE CONTRACT <br />DOCUMENTS. ACTUAL QUANTITY (COUNT) OF <br />2. <br />DEMOLITION INCLUDES BUT IS NOT LIMITED TO ITEMS <br />SHOWN DASHED. <br />NO. <br />QTY. <br />DESCRIPTION <br />NOTES <br />OWNER SUPPLIED ITEMS SHALL BE <br />DETERMINED THROUGH A THOROUGH REVIEW <br />3. <br />REMOVE ALL DOORS SHOWN DASHED. REFER TO DOOR <br />SCHEDULE FOR DOOR AND FRAME REPLACEMENT. <br />R5003.000 <br />1 <br />WALK-IN PANELS <br />- <br />AND ACCOUNTING OF THE CONTRACT <br />4. <br />COORDINATE REMOVAL AND DISPOSAL OF EXISTING <br />EQUIPMENT NOTES <br />DRAWINGS. <br />FIXTURES WITH MECHANICAL SERVICES CONSTRUCTION <br />MANAGER. <br />5. FINISHES FOR OWNER SUPPLIED EQUIPMENT ARE SPECIFIED PER BID ALIGNMENT BETWEEN OWNER AND OEM <br />2. REFERENCE APPENDIX A IN THE <br />5. <br />REMOVAL OF GONDOLAS AND/OR RACKING AS INDICATED <br />SPECIFICATIONS TO DETERMINE WHO IS <br />ON FXS SHEETS WILL BE PERFORMED BY OTHERS. <br />ABBREVIATION KEY <br />RESPONSIBLE FOR THE INSTALLATION OF <br />OWNER FURNISHED PRODUCTS. <br />ES EQUIPMENT SUPPLIER <br />RC <br />REFRIGERATION CONTRACTOR, REF SPEC 15600 <br />GC GENERAL CONTRACTOR <br />WM <br />WALMART <br />INTERIOR NON -LOAD BEARING PARTITION HEADER SCHEDULE <br />HEADER <br />LENGTH <br />HEADER <br />MEMBERS <br />HEADER <br />TRACKS <br />JAMB <br />STUDS <br />UP TO 4'-0" <br />2 C3 5/8x1 1 /4"x20 GA <br />2 C3 5/8x20 GA <br />2 C3 5/8x1 1 /4"x20 GA <br />UP TO 1 U-0" <br />2 C6x1 5/8"x18 GA <br />2 C6x18 GA <br />2 C6x1 5/8"x18 GA <br />14'-0" <br />2 C8x1 5/8"x18 GA <br />2 C6x18 GA <br />2 C6x1 5/8"x18 GA <br />18'-0" <br />2 C8x1 5/8"x16 GA <br />2 C6x16 GA <br />2 C6x1 5/8"x16 GA <br />20'-0" <br />2 C10x1 5/8"x16 GA <br />2 C6x16 GA <br />2 C6x1 5/8"x16 GA <br />24'-0" <br />(2) C12x1 5/8"x16 GA <br />(2) C6x16 GA <br />(2) C6x1 5/8"x16 GA <br />NOTES: <br />1. MAX WALL HEIGHT ABOVE HEADER ASSEMBLY IS 14'-9". <br />2. SPLICING OF HEADER AND JAMB MEMBERS IS NOT PERMITTED. <br />3. MAX SPAN FOR OPENINGS TO RECEIVE INFILL BELOW THE HEADER IS 19'4'. <br />4. JAMBS NOT TO DECK ARE TO BE BRACED IN ACCORDANCE WITH THE PARTITION <br />BRACING DETAILS. 3 5/8" JAMBS BEYOND 13'-4" ARE TO BE BRACED ABOVE THE <br />OPENING AND SUCH THAT THE MAXIMUM UNBRACED LENGTH IS NOT EXCEEDED. <br />5. FRAMING MEMBERS ARE NOT SIZED FOR VERTICAL LOAD OTHER THAN THAT OF <br />THE PORTION OF WALL ABOVE THE OPENING. <br />METAL STUD REF <br />PLANS AND SECTIONS______-L <br />(1) #10 TEK SCREW AT <br />EACH VERTICAL STUD <br />20 GA BOTTOM TRACK <br />TOP TRACK REF <br />SCHED <br />STUD HEADERS REF <br />SCHED <br />FINISH AS INDICATED <br />BOTTOM TRACK REF <br />SCHED <br />FASTEN HEADER ASSEMBLY <br />WITH (1) #10 TEK SCREW AT <br />VARIES <br />EACH FLANGE AND 12" OC FOR <br />THE LENGTH OF THE HEADER <br />SECTION -A <br />DOUBLE MTL STUD <br />AT JAMBS REF SCHED <br />#10 TEK SCREWS AT <br />16" O.C. VERT. <br />16 GA TRACK WITH (3) #10 <br />TEK SCREWS EACH SIDE <br />TO HEADER AND (6) #10 <br />TEK SCREWS TO JAMB --- <br />HEADER <br />ASSEMBLY <br />REFSCHED <br />(2) #10 TEK SCREWS <br />AT 24" OC VERT <br />SECTION-B <br />(1)#10TEK i+I i+ <br />r--ter--� <br />SCREW EACH I it II l <br />SIDE. SPACE 1 + 1� <br />AT 24" OC. I II II II I <br />(2) #10 TEK SCREWS <br />EACH SIDE AT JAMBS <br />16 GA DEEP LEG <br />DEFLECTION TRACK. REF <br />PARTITION DETAILS. <br />C6" x 1 5/8" x 18 GAUGE EACH <br />SIDE OF JAMB. FASTEN TO <br />TRACK WITH (2) #10 TEK <br />SCREWS EACH SIDE. DO <br />NOT ATTACH TO JAMB. <br />DETAIL-C <br />ATTACH TO SLAB 20 GAUGE <br />WITH (2) 0.145 DIA. CONT. STUD <br />PAF'S AT BASE OF TRACK <br />JAMB <br />4 a - <- < - <br />•'a -- <br />a <br />•a• �n - <br />rda n • - <br />(1) #10 TEK SCREW (2) 0.145 DIA. <br />EACH FLANGE OF PAF'S AT 24" <br />EACH STUD OC <br />DETAIL-D <br />HEADER CONNECTION DETAIL <br />1 1 /2" = 1'-0" <br />VESTED STUD <br />-IEADER WITH <br />3YP. BD. <br />3EF 4-A1 <br />VESTED STUD <br />DOLUMNS WITH <br />3YP. BD. AND <br />CORNER GUARDS <br />ADJACENT <br />COOLER ETR <br />z <br />O <br />P <br />0 <br />w <br />U) <br />- - - - - - - - - - <br />DETAIL I I I I <br />I + i _ I + I <br />C I Ir-T ,I I <br />I I I <br />+�I I�+� <br />+ <br />+ <br />METAL STUD <br />HEADER REF SCHED <br />16 GA TRACK WITH (3) #10 TEK <br />SCREWS EACH SIDE TO HEADER <br />AND (6) #10 TEK SCREWS TO JAMB <br />METAL STUD JAMB I <br />REF SCHED <br />16 GA TRACK TO TOP <br />OF HEADER------- <br />r <br />a 4 <br />SECTION B <br />925 PICKUP <br />,.,�„ �,.,�.. SHEET NOTES <br />FII WALL SH <br />REPAIR DAMAGED WALL FINISHES TO MATCH ADJACENT. <br />REPAIR/REPLACE DAMAGED FRP PANELS TO MATCH EXISTING <br />1. ALL EQUIPMENT SHOWN DASHED TO BE PROVIDED BY <br />WALMART UNO. <br />INSTALL NEW BASE TO MATCH EXISTING ON NEW AND <br />REPLACED FRP PANELS <br />2. ALL STEEL RACKS TO BE FURNISHED BY WALMART AND <br />ANCHORED BY CONTRACTOR. REFER TO RACK <br />ANCHORAGE PLAN FOR STEEL RACK AND/OR GONDOLA <br />REPAIR ALL DAMAGED WALL TILE. <br />SHELVING FIXTURE ANCHORING REQUIREMENTS. <br />3. REPAIR BOLT HOLES AND SPALLS RESULTING FROM <br />NEW DOUBLE STUD COLUMNS AND HEADER AT NEW <br />OPENING WRAP WITH FINISHES TO MATCH ADJACENT <br />MERCHANDISE FIXTURE AND OR STORAGE RACK <br />WALLS. <br />RELOCATION OR REMOVAL. REF SPEC 03905. FILL ALL <br />BOLT HOLES AND SPALLS RESULTING FROM FIXTURE <br />AND OR STORAGE RACK RELOCATION OR REMOVAL IN <br />FLOOR <br />NON CUSTOMER ACCESSIBLE AREAS WITH NON SHRINK <br />GROUT. <br />CONCRETE FLOORS ETR. <br />4. STUD WALL DIMENSIONS ARE TO THE FACE OF THE <br />STUDS. <br />QUARRY TILE AND EPDXY REPAIR/REPLACE AS REQUIRED <br />TO MATCH EXISTING <br />5. WALLS AND INFILL OF EXISTING OPENINGS ARE TO <br />- <br />MATCH THE CONSTRUCTION AND FINISHES OF <br />ADJACENT EXISTING WALLS. <br />TRANSITION BETWEEN EXISTING FLOORING WITH 6" R050 <br />6. PROPER INSTALLATION OF JOINT SEALANTS IS CRITICAL <br />INTERLOCKING RAMP THRESHOLD AS REQUIRED IF MORE <br />TO MEETING WALMART QUALITY ASSURANCE <br />THAN ONE FLOORING TYPE EXISTS. REPAIR CONCRETE AS <br />STANDARDS. PROVIDE SEALANTS IN ACCORDANCE <br />REQUIRED AT LOCATIONS OF DEMOLISHED WALLS AND <br />WITH DRAWINGS AND SPECIFICATIONS. REFERENCE <br />FIXTURES IN ACCORDANCE WITH SECTION 03905. <br />SECTION 07900 FOR SEALANT SCHEDULE. <br />COORDINATE WITH VENDOR. <br />7. ALL JOINTS BETWEEN DISSIMILAR MATERIALS SHALL BE <br />SEALED AS REQUIRED FOR A COMPLETE AND PROPER <br />CEILING <br />INSTALLATION, REGARDLESS OF WHETHER SHOWN ON <br />THE DRAWINGS OR INDICATED IN THE SPECIFICATIONS, <br />EXISTING CEILING TILE TO REMAIN. REPLACE ANY <br />DAMAGED CEILING TILE TO MATCH EXISTING AND CLEAN <br />SUCH JOINTS NOT SHOWN OR SCHEDULED SHALL BE <br />CEILING GRID, AIR GRILLES/DIFFUSERS, SECURITY GLOBES <br />SEALED WITH SEALANTS CONSISTENT WITH SPECIFIED <br />AND SPRINKLER HEADS. CLEAN LIGHT LENSES, UNO. <br />MATERIALS OR AS RECOMMENDED BY THE <br />REPLACE ANY DAMAGED ITEMS AS REQUIRED. <br />MANUFACTURER FOR THE SPECIFIC APPLICATION. <br />ICE CREAM <br />FREEZER <br />-------------- <br />------------ <br />------------------ <br />M EAT <br />COOLER <br />OGP DOLLIES, TYP <br />------------------- <br />----------------- <br />O ' <br />O <br />m _ <br />U.................. <br />O <br />01 <br />MEAT HOLDING <br />REMOVEDOOR <br />AND FRAME <br />� <br />°�.yi �.,' <br />EXISTING OGP MEAT HOLDING <br />DOLLLIES TO COOLER REMOVE EXISTING <br />REMAIN <br />RACKS <br />rr <br />ij <br />li �� li i' lil <br />r II <br />\ _...:._....�_ <br />@ I <br />\I L_-F_ <br />cr <br />N�w II I: RD8022.145 <br />\ w p ' MERCHANDISE <br />\\ L J p g II REACH -IN <br />UIE <br />U) I - V I RELOCATED OGP CASE <br />DOLLIES <br />ALUM. CORNER <br />GUARD <br />REMOVE I\ so'. <br />EXISTING RACKS: \\ <br />�\ ... <br />CD <br />NEW DOUBLE <br />EXISTING OGP -� i ;: STUD COLUMNS ;,, <br />WALL AND DOOR <br />8. ROUTE ALL UTILITY SERVICE LINES (PIPES AND CONDUIT) WITHIN <br />STUD WALLS WHEREVER POSSIBLE. ON COOLER/FREEZER PANELS IN <br />FOOD PREPARE AS WHERE UTILITIES MUST BE EXPOSED, <br />CONTRACTOR TO HAVE THE OPTION OF THE FOLLOWING: <br />A. SURFACE MOUNT UTILITIES WITH NON -CORROSIVE ANCHORS; <br />SEAL BOTH SIDES OF PIPE/CONDUIT TO PANEL <br />CONTINUOUSLY WITH SEALANT. <br />B. INSTALL UTILITIES 1/2" OFF FACE OF PANEL TO ALLOW FOR <br />CLEANING; USE ONLY NON -CORROSIVE ANCHORS; APPLY <br />CONTINUOUS SEALANT ALONG EDGES AND JOINTS. <br />C. COVER UTILITIES WITH 20 GAUGE STAINLESS STEEL BENT <br />PLATES MOUNTED TO WALL WITH NON -CORROSIVE <br />ANCHORS; APPLY CONTINUOUS SEALANT ALONG EDGES AND <br />JOINTS. <br />9. RELOCATION AND SETUP OF GONDOLA AND/OR RACKING AS <br />INDICATED ON THIS SHEET WILL BE PERFORMED BY G.C. <br />10. REMOVAL OF GONDOLAS AND/OR RACKING AS INDICATED ON THIS <br />SHEET WILL BE PERFORMED BY G.C. <br />11. LOCATE ALL 44" DEEP RACKS 6" FROM WALLS AND COLUMNS LINO. <br />12. LOCATE ALL RACKS LESS THAN 44" DEEP 3" FROM ALL WALLS AND <br />COLUMNS UNO. <br />13. INSTALL ALUMINUM CORNER GUARDS AT ALL OUTSIDE CORNERS <br />WITH WAINSCOT. LOCATIONS SHOWN IN PLAN AND ELEVATION ARE <br />NOT INDICATIVE OF ALL LOCATIONS WHERE CORNER GUARDS ARE <br />TO BE INSTALLED. <br />CARTS TO REMAIN <br />EXISTING MANAGERS <br />STATION TO REMAIN <br />EXISTING PRINTER AND <br />STAND TO REMAIN <br />N OT N NO N <br />LONNCO <br />NCO Ntf)O <br />1 y �� <br />226 <br />0 c; viN <br />V o cA ca . . <br />- <br />_ � 0U <br />O�� <br />N z <br />T <br />m N <br />0 <br />w <br />m <br />H <br />�� <br />¢x <br />ww¢ To< T ¢ <br />w <br />U) <br />OJ <br />Dx¢ Owriwq <br />D <br />LL¢ <br />o <br />ZUUwxQ <br />HOCFa�¢- <br />o <br />d W <br />ffiN <br />cwo m: U O ¢ nl <br />- W w Z <br />� m H <br />Ow <br />a¢ <br />cJn<F¢a~oowox <br />Z <br />¢� <br />Ocnw�Xwm¢j¢~ <br />p <br />0 <br />�cn <br />w��-wxzaw <br />z�oF¢-5 CC <br />J <br />oOw}cn,0n¢UZ <br />0mDw <br />wO zozoz¢�ww <br />F- <br />LOz <br />w�MZO <br />w0061LU00 <br />F0LLo�mmawoaU) Uom <br />U) <br />F_ <br />z <br />Q <br />U) <br />z <br />0 <br />0 <br />0 <br />U) <br />N <br />O O o <br />C=) o cr <br />00 0 <br />LL <br />o <br />o <br />uV 0 <br />J z <br />Jw 00 <br />� � T <br />F- <br />W w <br />m <br />Nz <br />m <br />O <br />ISSUE BLOCK <br />CHECKED BY: <br />TTH <br />DRAWN BY: <br />EB <br />PROTO CYCLE: <br />07/17/18 <br />[DOCUMENT DATE: <br />07/31/18 <br />i m <br />FLOOR <br />PLANS AND <br />DETAILS <br />INTERIOR ELEVATION <br />1 /4" = V-0" <br />PICKUP DEMO PLAN <br />1 /8" = V-0" <br />PICKUP FLOOR PLAN <br />1 /8" = V-0" <br />SHEET: <br />A 1 <br />