ELECTRICAL SYMBOLS <br />LEGEND <br />10.29.10 ES03 <br />(SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) <br />SYMBOL <br />DESCRIPTION <br />O <br />FLUORESCENT / LED OR HID FIXTURE <br />/ <br />(WALL MOUNTED/CEILING MOUNTED) <br />0 _ <br />FLUORESCENT / LED FIXTURE <br />FLUORESCENT / LED FIXTURE, <br />e ' <br />NIGHT LIGHT <br />VOLUMETRIC LED FIXTURE <br />ENCLOSED FREEZER LIGHT <br />TRACK LIGHTING <br />/ ® <br />EXIT FIXTURE <br />/ <br />(WALL MOUNTED/CEILING MOUNTED) <br />D04 <br />EMERGENCY LIGHT <br />(WALL MOUNTED/CEILING MOUNTED) <br />SINGLE POLE SWITCH <br />$3 <br />3-WAY SWITCH <br />$4 <br />4-WAY SWITCH <br />$K <br />KEYED SWITCH <br />$D <br />DIMMER SWITCH <br />$VS <br />VARIABLE SPEED SWITCH <br />$M <br />MANUAL MOTOR SWITCH <br />SINGLE POLE OCCUPANCY <br />`IDS <br />SENSOR SWITCH <br />$OS2 <br />DOUBLE POLE OCCUPANCY <br />SENSOR SWITCH <br />CEILING MOUNTED OCCUPANCY <br />O(ED) <br />SENSOR SWITCH <br />RECEPTACLE,DUPLEX <br />RECEPTACLE, DUPLEX, <br />MOUNTED HORIZONTALLY <br />RECEPTACLE, GFI <br />© <br />RECEPTACLE, DUPLEX FLUSH FLOOR <br />RECEPTACLE, DUPLEX ISOLATED <br />GROUND FLUSH FLOOR <br />RECEPTACLE, DOUBLE DUPLEX <br />RECEPTACLE, DUPLEX <br />ISOLATED GROUND <br />RECEPTACLE, DOUBLE DUPLEX, <br />ISOLATED GROUND <br />RECEPTACLE, SIMPLEX TWIST LOCK, <br />L5-15R, LINO <br />RECEPTACLE, SIMPLEX TWIST LOCK, <br />ISOLATED GROUND, L5-15R, LINO <br />RECEPTACLE, DUPLEX TWIST LOCK, <br />L5-15R, LINO <br />RECEPTACLE, DUPLEX TWIST LOCK, <br />ISOLATED GROUND, L5-15R, LINO <br />RECEPTACLE, SPECIAL <br />RECEPTACLE, SIMPLEX <br />RECEPTACLE, PLUG -MOLD <br />O <br />JUNCTION BOX <br />(WALL MOUNTED/CEILING MOUNTED) <br />O <br />THERMOSTAT <br />(WALL MOUNTED/CEILING MOUNTED) <br />O <br />ALARM JUNCTION BOX, <br />(WALL MOUNTED/CEILING MOUNTED) <br />ALARM JUNCTION BOX, <br />® <br />FOR REMOTE TEST/RESET <br />(WALL MOUNTED/CEILING MOUNTED) <br />0 <br />EQUIPMENT CONNECTION POINT <br />(PROVIDED WITH EQUIPMENT) <br />Eh <br />NON -FUSED DISCONNECT <br />FUSED DISCONNECT <br />CIRCUIT, CONCEALED IN WALLS OR <br />CEILING, E INDICATES EXISTING <br />WIRING <br />CIRCUIT, CONCEALED IN SLAB FLOOR, <br />E INDICATES EXISTING WIRING <br />r— <br />CIRCUIT, EXPOSED, <br />E INDICATES EXISTING WIRING <br />H <br />CONDUIT SLEEVE <br />1� <br />FLUSH MOUNTED PANELBOARD <br />SURFACE MOUNTED PANELBOARD <br />�- - - — - - — <br />MANUFACTURED WIRING SYSTEM <br />- <br />TELEPHONE / DATA BOX FOR ISD <br />LOW VOLTAGE CABLE <br />BOX FOR OTHER <br />® <br />TELEPHONE, FLUSH FLOOR <br />0 <br />MOTOR <br />0 <br />TELEPOWER POLE <br />g <br />PUSH BUTTON <br />ElBUZZER <br />SAIL SWITCH <br />SS <br />JUNCTION BOX <br />SO <br />SMOKE DETECTOR <br />HORN/STROBE <br />DH <br />DOOR HOLD OPEN <br />ABBREVIATIONS <br />CF CEILING FAN <br />CO CHECK OUT <br />CW CASH/WRAP <br />EF EXHAUST FAN <br />ETR EXISTING TO REMAIN <br />G GROUND <br />GFI GROUND FAULT CIRCUIT INTERRUPTER <br />IG ISOLATED GROUND <br />REC REFRIGERATION ELECTRICAL CONTRACTOR <br />RC REFRIGERATION CONTRACTOR <br />RH RADIANT HEATER <br />Sc SECURITY CAMERA <br />TR TAMPER RESISTANT <br />UH UNIT HEATER <br />WH WATER HEATER <br />WP WEATHER PROOF COVERPLATE <br />WR WEATHER RESISTANT RECEPTACLE <br />REVISE TEMPERATURE <br />SETPOINT <br />OGP COOLER <br />0 <br />I <br />I <br />I <br />I <br />f --(2( -1 ) <br />1 <br />P) <br />1 0 <br />K20A-1 ) y <br />i <br />o I i 16.492 <br />4 <br />I ii I <br />I ii i <br />I ii I <br />EDC4 / <br />RELOCATE LIGHT SWITCH TO <br />WALL AND RECONNECT TO <br />EXISTING LIGHTING CIRCUIT <br />SEAFOOD INTERNAL HIGH POWER PLAN <br />1 /8" = 1'-0" <br />(: D 1 KEY PLAN <br />16.492 E.C. SHALL COORDINATE WITH GENERAL <br />1 <br />CONTRACTOR AND ARCHITECTURAL <br />TELEPOWER POLE(S): MOUNT JUNCTION BOX(ES) TO TOP <br />DEMOLITION PLANS THE EXTENT OF <br />SIDE OF BOTTOM CHORD OF BAR JOIST. INSTALL <br />ELECTRICAL DEMOLITION. REMOVE <br />FURNISHED PRE -WIRED POWER POLE AND TERMINATE <br />CONDUITS AND WIRES ALL THE WAY BACK TO <br />PROVIDED FLEXIBLE CONDUIT AND WIRING TO JUNCTION <br />ORIGINATING JUNCTION BOXES OR <br />BOX. PROVIDE UNISTRUT SUPPORTS AND HARDWARE. TO <br />PANELBOARDS. DEMOLITION SHALL NOT <br />SECURE TELEPOWER POLE PLUMB TO BUILDING <br />AFFECT ACTIVE CIRCUITS. LABEL <br />STRUCTURE. <br />DEMOLISHED CIRCUIT(S) IN PANELBOARDS <br />AS "SPARE". COORDINATE EXACT <br />2. PROVIDE LIQUID -TIGHT FLEXIBLE METAL CONDUIT AND <br />REQUIREMENTS WITH EXISTING CONDITIONS <br />WIRING FROM DISCONNECT SWITCH OR JUNCTION BOX TO <br />PRIOR TO BID. <br />EQUIPMENT KNOCKOUT OR ELECTRICAL CONNECTION <br />16.W04 120 VOLT GENERAL POWER CIRCUIT(S): <br />POINT. <br />FURNISH AND INSTALL NEW 20 AMP, 120 VOLT <br />3. WHERE EQUIPMENT NAMEPLATE PROTECTIVE DEVICE <br />CIRCUIT(S), OR AS SPECIFIED ON DRAWINGS. <br />RATING DIFFERS FROM SIZE PROVIDED, CHANGE OUT <br />FEED FROM NEAREST 120 VOLT PANEL, WITH <br />BRANCH CIRCUIT WIRING AND OVERCURRENT DEVICE TO <br />ADEQUATE SPACE AND AMPACITY. A. CIRCUIT <br />APPROPRIATE RATING PER NEC. <br />BREAKER FOR CIRCUITS INDICATED WITH <br />(GFI) SHALL BE GFCI TYPE FOR PERSONNEL <br />4. ELECTRONIC FIRE PROTECTION/SECURITY ALARM BOXES <br />PROTECTION. <br />AND CONDUITS SHOWN ON POWER PLANS SHALL BE <br />16.W07 208 VOLT GENERAL POWER CIRCUIT: <br />PROVIDED UNDER THIS CONTRACT. IN ADDITION, UNLESS <br />FURNISH AND INSTALL NEW 208 VOLT <br />NOTED OTHERWISE, THE FOLLOWING GENERAL NOTES <br />CIRCUIT, AS SPECIFIED ON DRAWINGS. FEED <br />APPLY: <br />FROM NEAREST 208 VOLT PANEL, WITH <br />A. ALL ALARM JUNCTION BOXES SHALL BE <br />ADEQUATE SPACE AND AMPACITY. <br />4"X4"X2-1/8" MINIMUM. <br />B. ALARM RACEWAYS SHALL BE 3/4" MINIMUM WITH <br />PULL WIRE AND INSULATING BUSHINGS AT END OF <br />VERTICAL RACEWAY RUN. <br />C- VERTICAL RACEWAYS FROM ALARM BOXES SHALL BE <br />EITHER CONCEALED INSIDE WALL OR SURFACE <br />MOUNTED (TO MATCH JUNCTION BOX MOUNTING). ALL <br />VERTICAL RUNS SHALL BE TURNED 90-DEGREES AT <br />TOP SIDE OF BOTTOM CHORD OF BAR JOIST AND <br />EXTENDED HORIZONTALLY TO A LOCATION ACCESSIBLE <br />BY VERTICAL FLOOR TYPE LIFT. <br />5. UPON COMPLETION OF ELECTRICAL INSTALLATION AND <br />PRIOR TO ENERGIZING CIRCUIT: <br />A. INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE. <br />B. PERFORM CONTINUITY TEST. <br />C- VERIFY PROPER PHASING CONNECTION TO ALL THREE <br />PHASE MOTOR LOADS. <br />20A WIRE SIZING SCHEDULE <br />ALL WIRE SIZES SHOWN ON PANEL SCHEDULES AND <br />PLANS ARE INTENDED TO BE MINIMUM ACCEPTABLE <br />WIRE SIZE. <br />THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE <br />WIRE FOR 20 AMP CIRCUITS (120 AND 277 VOLT). <br />LENGTHS (IN FEET) ARE INTENDED TO BE MAXIMUM. <br />FINAL CONNECTIONS: WHERE 20A BRANCH CIRCUITS <br />HAVE #8 AND LARGER WIRE CALLED OUT, #10AWG WIRE <br />MAY BE USED FOR THE FINAL CONNECTION (15- MAX.). <br />120 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />200 FT. <br />325 FT. <br />490 FT. <br />770 FT. <br />6-10 AMPS <br />100 FT. <br />160 FT. <br />245 FT. <br />385 FT. <br />11-15 AMPS <br />70 FT. <br />1 110 FT. <br />165 FT. <br />255 FT. <br />277 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />480 FT. <br />760 FT. <br />1170 FT. <br />1865 FT. <br />6-10 AMPS <br />240 FT. <br />380 FT. <br />585 FT. <br />930 FT. <br />11-15 AMPS <br />160 FT. <br />250 FT. <br />390 FT. <br />620 FT. <br />7 <br />08.31.12 EN08 <br />1 FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND <br />LABOR, FOR A COMPLETE INSTALLATION IN ALL RESPECTS, <br />READY FOR INTENDED USE AND IN STRICT ACCORDANCE WITH <br />NEC, NESC, STATE, AND LOCAL CODES, AND MANUFACTURER'S <br />RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS. <br />A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS <br />THE ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR <br />WALLS. <br />B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE. <br />C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE <br />OPERATIONS. COORDINATE ALL DISRUPTIONS WITH <br />WALMART CONSTRUCTION MANAGER AND STORE MANAGER. <br />D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESSES <br />BEFORE INSTALLING BOXES. FURNISH AND INSTALL <br />EXTENDED BOXES OR BOX EXTENDERS WHERE REQUIRED. <br />E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED <br />PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS <br />PROPERLY COVERED AND THAT ALL TRIM IS IN GOOD <br />CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. <br />2- PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: <br />A• FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE <br />STOPPING. <br />B. NEUTRALIZATION AREA: SEAL PER MECHANICAL DETAIL. <br />C. FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM <br />SEALANT. <br />D. EXTERIOR: REFER TO ARCHITECTURAL DOCUMENTS FOR <br />SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED <br />DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY <br />PENETRATIONS. <br />3. PROVIDE A SEPARATE EQUIPMENT GROUNDING CONDUCTOR <br />(SIZE PER NEC) IN PVC TYPE CONDUIT, POWER CIRCUITS, <br />ISOLATED GROUND CIRCUITS, OR AS SHOWN ON PLANS. <br />CONDUIT SHALL BE SIZED PER NEC BASED ON THWN 600 <br />VOLT COPPER SINGLE CONDUCTORS, PLUS THE EQUIPMENT <br />GROUNDING CONDUCTOR. <br />4. WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM <br />FINISHED FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED <br />OTHERWISE ON PLANS. COORDINATE THE STANDARD <br />MOUNTING HEIGHTS WITH MASONRY: <br />A. SWITCHES +46" <br />B. RECEPTACLES +20" <br />C. VOICE/DATA +20" <br />5. WIRING SHALL INCLUDE FINAL CONNECTION TO ALL EQUIPMENT <br />IN CONFORMANCE WITH EQUIPMENT SUPPLIER WIRING <br />DIAGRAMS. <br />6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE <br />PANELBOARD IDENTIFICATION SCHEDULES FOR PANELBOARDS <br />AFFECTED BY REMODEL. <br />7. NEW OVERCURRENT PROTECTIVE DEVICES INSTALLED IN <br />EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL <br />MATCH THE TYPE AND AIC RATING OF EXISTING OVERCURRENT <br />PROTECTIVE DEVICES. <br />8. BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG THHN <br />UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A <br />BRANCH CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 <br />AWG WIRE SHALL BE USED FOR THE FINAL CONNECTION <br />(15-FT MAXIMUM). <br />9. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND <br />DERATE CURRENT CARRYING CONDUCTORS PER NEC. <br />10. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE <br />SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. <br />UTILIZE ONLY THE TOP AND BOTTOM CHORDS FOR <br />SUPPORTING THE ELECTRICAL SYSTEM INSTALLATIONS. <br />11. DEVICES SHOWN ON COOLER/FREEZER PANELS SHALL BE <br />SURFACE MOUNTED UNLESS NOTED OTHERWISE. REFER TO <br />ARCHITECTURAL DOCUMENTS FOR CONDUIT INSTALLATION AND <br />SEALING REQUIREMENTS. <br />12. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM <br />AND BRANCH CIRCUITS NOTED BY LEGEND SHALL BE <br />INSTALLED UNDER SLAB. ALL OTHER FEEDER AND BRANCH <br />CIRCUITS SHALL BE INSTALLED OVERHEAD. PROVIDE EXTERIOR <br />COATED GRC BENDS ON ALL CONDUIT RUNS THAT HAVE 45 <br />DEGREE BENDS OR GREATER. REF SPECIFICATIONS. <br />13. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS <br />AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY <br />LOCAL CODES. <br />14. EXISTING ELECTRICAL AND ALARM: <br />A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS <br />EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING <br />EQUIPMENT, DEVICES, OR LIGHTING TO REMAIN, BUT NOT <br />SHOWN ON DRAWINGS, PROVIDE LABOR AND MATERIALS TO <br />REWORK CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING <br />OPERATION. <br />B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT <br />EXISTING UNDERGROUND SERVICES (ELECTRICAL, <br />TELEPHONE, PARKING LOT LIGHTING CIRCUITRY, ETC.) <br />PROVIDE ALL MATERIALS AND LABOR AS REQUIRED TO <br />REROUTE, SLEEVE, OR OTHERWISE REWORK THESE SERVICES <br />TO MAINTAIN THEIR EXISTING OPERATION. <br />C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES <br />DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM <br />AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO <br />THAT SYSTEMS REMAIN OPERATIONAL AT ALL TIMES. <br />D- DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE <br />NOTED. <br />15. EXISTING ELECTRICAL DEMOLITION: <br />A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL <br />EQUIPMENT CONDUIT, AND CONDUCTORS AS INDICATED ON <br />THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. <br />REMOVE ALL PANELBOARDS DISCONNECT SWITCHES BOXES <br />W <br />O <br />w W,r,� J(Ct I- <br />D 0 �WoF} <br />2 � F UJw �wu o. <br />n w z�-o0z n� <br />Lu <br />p F-O�FWowYZ LnF- <br />0 <br />aF F w OpoQwwo <br />�-o ��zoow <br />U- <br />uiw ro4�irawQW CO <br />of �zza,, ma>_ <br />t�� <br />z <br />�¢oQoul =->O �¢ <br />O <br />QwJ Qw �fn <,U OEHO=p <br />s-w DOzz xz� z <br />Z <br />MR' W : Qw U_OUQ <br />zcan� <br />p20,-,Z�Q,QO <br />rnx0 c> W <br />aW0ND Lu0 <br />a�U <br />womvo <br />W �2 F" Wa =goZwn <br />5cwZ�OU—�OwaDr <br />OQwWUW W�_ <br />t-��WrUov>aowL_jCCW¢��wr <br />tiro <br />M <br />co zzo <br />m <br />V0W <br />z <br />L0 <br />w <br />tM Q <br />Z <br />n 16 <br />� N <br />Q <br />� n <br />J <br />M � Q <br />U) <br />t N Ix <br />z <br />z <br />�m; <br />O <br />moo <br />U <br />US w <br />z <br />w <br />00 <br />2 <br />w <br />C)z <br />CD c:D <br />0 0 <br />_I <br />L <br />_ <br />w <br />L� <br />w <br />I, <br />� <br />0 <br />o <br />O <br />o <br />w <br />W <br />rn <br />M <br />o <br />!�2 <br />m <br />� <br />z <br />Z <br />W <br />O <br />~ <br />6 090 <br />^= <br />I..L <br />U) <br />W <br />N <br />w <br />m <br />z <br />m <br />O <br />ISSUE BLOCK <br />CHECKED BY: <br />SAG <br />DRAWN BY: <br />JOP <br />FILE NAME: <br />E1 <br />PROTO CYCLE: <br />07/03/18 <br />DOCUMENT DATE: <br />07/25/18 <br />RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH <br />WILL NOT BE REUSED. <br />B. SALES FLOOR: REMOVE UNUSED POWER DROP CONDUIT, <br />CONDUCTORS AND RELATED DEVICES SERVING SALES AREA <br />GONDOLAS BEING RELOCATED OR REMOVED. EXISTING <br />CONDUIT AND CONDUCTORS MAY BE REUSED FOR NEW �� �/� <br />POWER DROPS WHERE SIZE, RATING, AND CONDITION MEET g\� �1 <br />REQUIREMENTS INDICATED ON PLANS AND ALL U.L. \°`��®w,� <br />RATINGS. REMOVE ALL UNUSED CONDUIT AND . <br />CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER 6, V <br />FEASIBLE AND RELABEL DEMOLISHED CIRCUITS AS "SP, &.;B N 793319 t <br />PROVIDE HANDLE DEVICE TO LOCK "SPARE" CIRCUIT = s <br />B <br />BREAKER IN THE "OFF" POSITION. v171 ST E 0 .° <br />C. CONDUIT AND WIRING TO BE ABANDONED IN CEILING '�,°�.•'+� <br />SPACES AND OTHER NON-PUBLIC AREAS (I.E., THROUGH �llj�' �"'` ��'w� AUG 0 3 2918 <br />�_ <br />STOCKROOM AREA): CUT WIRING LOOSE AND REMOVE ��//��� � ��\ <br />FROM RACEWAY(S), LEAVING RACEWAY(S) IN PLACE. <br />CONDUIT TO BE ABANDONED IN WALLS OR FLOORS SHALL Randal C. Haase, P.E. <br />BE REMOVED BACK TO FINISHED SURFACE AND CAPPED <br />FL Li efiSe79#3i9 <br />INSIDE. REPAIR SURFACE(S) TO MATCH ADJACENT. <br />D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE <br />ABANDONED OR REMOVED SHALL REMAIN IN RESPECTIVE <br />PANELBOARD FOR FUTURE USE, UNLESS NOTED OTHERWISE <br />ON DRAWINGS. PROVIDE HANDLE DEVICE TO LOCK "SPARE" <br />CIRCUIT BREAKER IN THE "OFF" POSITION. <br />E. DEMOLISHED FLUORESCENT LIGHT FIXTURES: REFER TO <br />SELECTIVE SITE DEMOLITION SPECIFICATION FOR <br />DISPOSAL OF LIGHT FIXTURE. <br />F- BUILDING COMPONENTS ABANDONED BY THE SCOPE OF <br />WORK SHALL BE SECURED TO PREVENT FALLING, <br />LOOSENING, OR CREATING DAMAGE OF ANY KIND IN THE <br />FUTURE. <br />EXISTING CONDITIONS WERE TAKEN FROM <br />ORIGINAL DRAWINGS AND MAY NOT REFLECT <br />EXACT "AS -BUILT" CONDITIONS. CONTRACTOR <br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS <br />PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR <br />SHALL CAREFULLY COORDINATE NEW WORK AND <br />DEMOLITION WITH ALL OTHER DISCIPINES AND <br />EXISTING CONDITIONS. <br />NOTE: <br />RECEPTACLES, SWITCHES, DATA BOXES <br />AND THEIR CORRESPONDING COVER <br />PLATES SHALL BE WHITE NYLON. <br />EACH SUBCONTRATOR IS RESPONSIBLE FOR HAVING A <br />THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE <br />TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br />NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />THE WORK PROPERLY. NO ADDITIONAL <br />COMPENSATION SHALL BE ALLOWED BECAUSE OF <br />CONDITIONS THAT OCCUR DUE TO FAILURE TO <br />FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />ELECTRICAL <br />PLANS <br />SHEET: <br />El <br />