Laserfiche WebLink
m� <br />E <br />C <br />a <br />a <br />N <br />NOTES: <br />1. DISTANCE BETWEEN LATERAL ROWS AND EMITTER SPACING <br />TO BE BASED ON SOIL TYPE, PLANT MATERIALS AND <br />CHANGES IN ELEVATION. <br />2. LENGTH OF LONGEST DRIPLINE LATERAL SHOULD NOT <br />EXCEED THE MAXIMUM SPACING SHOWN IN THE <br />ACCOMPANYING TABLE. <br />3. WHEN USING 17MM INSERT FITTINGS WITH DESIGN PRESSURE <br />OVER 5OPSI, IT IS RECOMMENDED THAT STAINLESS STEEL <br />CL P <br />AM S BE INSTALLED ON EACH FITTING. <br />NOTE: <br />1. ALLOW A MINIMUM OF 6-INCHES OF DRIPLINE <br />TUBING IN VALVE BOX IN ORDER TO DIRECT <br />FLUSHED WATER OUTSIDE VALVE BOX. <br />O PVC EXHAUST HEADER <br />O PVC SCH 40 TEE OR EL (TYPICAL) <br />OBARB X MALE FITTING: <br />RAIN BIRD XFF-MA FITTING (TYPICAL) <br />OFLUSH POINT (TYPICAL) <br />4 SEE RAIN BIRD DETAIL "XFD FLUSH <br />POINT" <br />O PERIMETER OF AREA <br />PERIMETER DRIPLINE PIPE TO BE <br />© INSTALLED 2%4" FROM PERIMETER <br />OF AREA <br />O PVC SUPPLY PIPE FROM RAIN BIRD <br />CONTROL ZONE KIT (SIZED TO MEET <br />LATERAL FLOW DEMAND) <br />INSET A <br />O PVC SUPPLY MANIFOLD <br />O CONNECTION FROM SUPPLY MANIFOLD TO <br />DRIPLINE (TYPICAL)- SEE INSET A <br />ON -SURFACE DRIPLINE: <br />10 RAIN BIRD XF SERIES DRIPLINE(TYPICAL) <br />POTABLE: XFD DRIPLINE <br />NON -POTABLE: XFDP DRIPLINE <br />BARB X FEMALE FITTING: <br />11 RAIN BIRD XFD-TFA-075 FITTING <br />12 3/4" PVC NIPPLE, LENGTH AS NECESSARY <br />13 RAINBIRD TDS-050 TIE DOWN STAKE, <br />STAGGER T APART ALONG DRIP LINE <br />AND AT AND AT FITTINGS. (TYPICAL) <br />XFD Dripline Maximum Lateral Lengths (Feet) <br />Inlet Pressure psi <br />12" Spacing <br />18" Spacing <br />24" Spacing <br />Nominal Flow (gph) <br />Nominal Flow (gph) <br />Nominal Flow (gph) <br />0.6 <br />0.9 <br />0.6 <br />0.9 <br />0.6 <br />0.9 <br />15 <br />273 <br />155 <br />314 <br />250 <br />424 <br />322 <br />20 <br />318 <br />169 <br />353 <br />294 <br />508 <br />368 <br />30 <br />360 <br />230 <br />413 <br />350 <br />586 <br />414 <br />40 <br />395 <br />255 <br />465 <br />402 <br />652 <br />474 <br />50 <br />1 417 <br />1 285 <br />1 528 <br />1 420 <br />1 720 <br />488 <br />60 <br />1 460 <br />1 290 <br />1 596 <br />1 455 1 <br />780 <br />1 514 <br />XFD ON -SURFACE DRIPLINE - CENTER FEED LAYOUT <br />1O TOP OF MULCH LAYER <br />FLUSH CAP FOR EASY FIT <br />OCOMPRESSION FITTINGS: <br />POTABLE:RAIN BIRD MDCFCAP <br />NON -POTABLE: RAIN BIRD MDCFPCAP <br />OEASY FIT COUPLING: <br />RAIN BIRD MDCFCOUP <br />OSUBTERRANEAN EMITTER BOX: <br />RAIN BIRD SEB 7XB <br />O RAIN BIRD XF BLANK TUBING <br />FINISH GRADE <br />7O PVC EXHAUST HEADER <br />® PVC SCH 40 TEE OR EL <br />OBARB X MALE FITTING: <br />RAIN BIRD XFF-MA FITTING (TYPICAL) <br />ON -SURFACE DRIPLINE: <br />ORAIN BIRD XF SERIES DRIPLINE <br />10 POTABLE: XFD DRIPLINE <br />NON -POTABLE: XFDP DRIPLINE <br />O3-INCH MINIMUM DEPTH OF <br />11 3/4" WASHED GRAVEL <br />12 BRICK (1 OF 2) <br />XFD ON -SURFACE DRIPLINE FLUSH POINT <br />CAP ENDS &STAKE <br />THE STUB -UP <br />RECORD MEASUREMENTS <br />FROM TWO REFERENCE <br />POINTS TO THE MARK <br />INSTALLED STUB -UP BACK OF <br />CURB <br />_d <br />TAPE END INNER PIPE <br />OF SLEEVE <br />STUB -UP <br />SCHAO SOLVENT -WELD PVC <br />(REQUIREMENTS VARY - CHECK <br />LOCAL CODES FIRST) <br />ROUGH IN SLEEVING DETAIL <br />DRIP TUBING NOTES <br />1. INSTALL DRIP TUBING AT GRADE AND COVER WITH MULCH. TYPICAL SPACING FOR DRIP <br />TUBING IS 12" TO 18" ON CENTER. SPACING TO BE DETERMINED BY PLANT LAYOUT. REFER <br />TO LANDSCAPE PLAN. ANCHOR TUBING EVERY 10' WITH 12" LONG PLASTIC TUBING <br />STAKES. INSTALL FLUSH VALVE ASSEMBLIES AT ALL TUBING "DEAD ENDS". INSTALL <br />AIRIVACUUM RELIEF VALVES AT "HIGH POINTS" OF EVERY SECTION. <br />2. GRID LAYOUT SHALL BE USED ON THIS PROJECT. USE CENTER GRID LAYOUT WHERE <br />POSSIBLE. <br />3. WHEN SLEEVING DRIPLINE, USE BLANK DRIPLINE IN SLEEVE. SLEEVE SHALL BE 2X <br />DRIPLINE DIAMETER. NO EMITTER DRIPLINE SHALL BE PLACED IN SLEEVE. <br />4. THE LENGTH OF ANY DRIPLINE LATERAL SHALL NOT BE LONGER THAN: <br />12" EMITTERS Coil 0.9 GPH <br />a) @ 15 PSI = 155 FEET <br />b) @ 25 PSI = 169 FEET <br />c) @ 35 PSI = 230 FEET <br />d) @ 45 PSI = 255 FEET <br />LATERAL DISTANCE DOUBLED WHEN CENTER FEED LAYOUT USED (SEE CENTER FEED <br />LAYOUT DETAIL. <br />5. MANUAL FLUSH VALVE SHALL BE USED & PLACED WITH A 6" X 6" SUMP. VALVES SHALL BE <br />OPENED EVERY WATERING DAY FOR 2 WEEKS AND THEN A MINIMUM OF 2 TIMES A YEAR <br />TO CLEAR DRIPLINE OF DEBRIS. <br />6. AIR/VACUUM RELIEF SHALL BE INSTALLED WHEN THE CHANGE IN SLOPE OCCURS 3% OR <br />GREATER. <br />7. STAPLES SHALL BE USED AT 5' O.C. AND 2 STAPLES 'X'ED OVER EACH OTHER WITH ANY <br />CHANGE IN DIRECTION, ELBOWS, OR CROSSES. <br />8. SUPPLY, EXHAUST HEADERS AND DRIPLINE SHALL BE PLACED 2"- 4" FROM PLANTS AND <br />PAVEMENT EDGES. <br />9. BLANK DRIPLINE SHALL BE USED FOR ALL SUPPLY AND EXHAUST HEADERS, UNLESS <br />OTHERWISE NOTED ON PLANS. <br />10. PRIOR TO COVERING DRIPLINE, DRIPLINE CIRCUIT WILL BE PRESSURIZED AND TESTED <br />FOR PROPER OPERATION. <br />11. DRIP LINE LATERALS SHALL BE LAID IN THE LONGEST RUN, WHETHER IT BE THE WIDTH OR <br />LENGTH OF THE ZONE. <br />O MULCH <br />O FINISH GRADE <br />O3 OPERATION INDICATOR <br />RAIN BIRD MODEL: OPERIND <br />4 <br />ON -SURFACE DRIPLINE: <br />RAIN BIRD XF SERIES DRIPLINE <br />POTABLE: XFD SERIES <br />NON -POTABLE: XFDP SERIES <br />NOTE: <br />1. INSERT BARB TRANSFER FITTING DIRECTLY INTO DRIPLINE TUBING. <br />2. VAN NOZZLE MAY BE SET TO CLOSED, OR IF IT IS DESIRED TO <br />SEE SPRAY FROM THE NOZZLE, SET THE ARC TO Y4 PATTERN. <br />N-SURFACE DRIPLINE OPERATIONAL INDICATOR <br />10 <br />2"-4" <br />NOTES: <br />1. PLACE TIE DOWN STAKES EVERY THREE FEET IN SAND, <br />FOUR FEET IN LOAM, AND FIVE FEET IN CLAY. <br />2. AT FITTINGS WHERE THERE IS A CHANGE OF DIRECTION <br />SUCH AS TEES OR ELBOWS, USE TIE -DOWN STAKES ON <br />EACH LEG OF THE CHANGE OF DIRECTION. <br />3. SAVE YOUR HANDS. USE THE RAIN BIRD FITTINS-TOOL XF <br />INSERTION TOOL FOR FITTING ASSEMBLY. <br />ON -SURFACE DRIPLINE: <br />ORAIN BIRD XF SERIES DRIPLINE <br />POTABLE: XFD DRIPLINE <br />NON -POTABLE: XFDP DRIPLINE <br />O INLINE DRIP EMITTER OUTLET, SEE PLANS FOR <br />DRIPLINE OUTLET SPACING. <br />OBARB TEE 17x17xl7mm <br />RAIN BIRD XFF-TEE <br />OBARB COUPLING 17xl7mm <br />RAIN BIRD XFF-COUP <br />OBARB ELBOW 17xl7mm <br />RAIN BIRD XFF-ELBOW <br />BARB MALE ADAPTER <br />17mm X 1/2" MPT <br />O RAIN BIRD XFF-MA-050 <br />17mm X 3/4" MPT <br />RAIN BIRD XFF-MA-075 <br />O7 PVC TEE SxSxT <br />® PVC LATERAL SUPPLY HEADER <br />OTIE DOWN STAKE: <br />RAIN BIRD TDS-050 WITH BEND (TYPICAL) <br />10 MULCH <br />11 FINISH GRADE <br />12 RAIN BIRD XF SERIES BLANK TUBING LENGTH AS <br />REQUIRED <br />XFD ON -SURFACE DRIPLINE RISER ASSEMBLY <br />MAIN LINE AND 6" 6" 6" <br />CONTROL WIRE <br />12" 6" 12,E <br />PLY & <br />MIN. MIN. - -i IN. IN. <br />P.V.C. LATERAL DRIP <br />ZONE <br />WIRECONWITHIN <br />EXHAUST <br />DETAIL NOTES: HEADERS <br />1. ALL P.V.C. PIPING SHALL BE SNAKED IN TRENCHES. <br />2. ALL WIRING TO BE BUNDLED AND TAPED AT 20' INTERVALS. <br />3. ALL MAIN SUPPLY LINES TO BE INSTALLED AS PER <br />MANUFACTURER'S SPECIFICATIONS. <br />4. PROVIDE PIPE AND WIRE SLEEVES UNDER ALL PAVED SURFACES. <br />WIRE SHALL BE WITHIN SEPARATE 2" ELECTRICAL CHASE. <br />5. CONTRACTOR TO COMPLY WITH ALL LOCAL CODES AND <br />ORDINANCES IN REFERENCE TO THE INSTALLATION OF PVC PIPING <br />6. TIE A LOOSE 20' LOOP IN WIRING AT ALL CHANGES OF DIRECTION <br />GREATER THAN 30° UNTIE ALL LOOPS AFTER ALL CONNECTIONS <br />HAVE BEEN COMPLETED <br />7. INSTALL #14-1 TRACKING WIRE NEXT TO MAINLINE <br />TRENCHING DETAIL <br />SPRINKLERS IN LOW-LYING AREAS SHALL HAVE CHECK VALVES <br />INSTALLED 4" OFF CURB OR WALK <br />/114t\PY1111\11ffll1 111\IIII11/i Ii/\II it 1l01011 M/In <br />FINISH GRADE <br />6" PRS SPRAY HEAD <br />SCH. 40 PVC STREET ELL <br />SCH. 40 PVC FITTING <br />ON LATERAL LINE <br />PVC IPS FLEX PIPE <br />12" MIN. <br />6" POP-UP SPRAY HEAD DETAIL <br />PLANT MATERIAL <br />0 FINISH GRADE <br />03 MICRO -SPRAY POP-UP: <br />RAIN BIRD XERI-POP XP-120OX <br />® 1/2" POLYETHYLENE TUBING: <br />RAIN BIRD XF SERIES TUBING OR <br />RAIN BIRD XT-700 XERI-TUBE OR <br />RAIN BIRD XBS BLACK STRIPE TUBING <br />(� 1/4" SELF -PIERCING BARB CONNECTOR: <br />RAIN BIRD SPB-025 <br />© 1/4" DISTRIBUTION TUBING: <br />RAIN BIRD XQ TUBING <br />(LENGTH AS REQUIRED) <br />BIRD XERI-POP CAN UTILIZE THE FOLLOWING <br />=S: <br />J SQUARE NOZZLES (FORMERLY XPCN) <br />SERIES MPR NOZZLES (ALL <br />3URATIONS) <br />SERIES PLASTIC BUBBLERS <br />o SERIES MPR NOZZLES (8H, 8T AND 8Q) <br />XERI-POP MICRO SPRAY <br />NOTE <br />EARTH GROUND TO BE A <br />MINIMUM OF 8' AWAY FROM <br />DUAL-S AND AT A RIGHT ANGLE <br />TO THE TWO WIRE PATH <br />NOTE: All ICD 100 <br />DECODERS SHALL HAVE <br />THE FOLLOWING <br />ADDRESS AND <br />CORRESPONDING COLOR <br />ADDRESS 1 = Black <br />ICD-100 DECODER <br />TWO -WIRE DECODER CONTROL SYSTEM NOTES <br />O ID WIRE PATH TWISTED TO <br />NEXT DECODER <br />ODBY (2) <br />OTWO BLACK WIRES TO <br />SOLENOID/UP TO 15OFT <br />® ICD-100 DECODER <br />O DBRY-6 (3) <br />© JACKETED ID WIRE PATH <br />FROM CONTROLLER ALLOW 5 <br />ft SLACK PER DECODER 1/2 ON <br />EITHER SIDE OF DECODER <br />O] TO EARTH GROUND <br />INSTALLED PER ASIC <br />GUIDELINES. 1 PER 8 <br />DECODERS OR EVERY 500ft. <br />1. THE DECODERS MAY BE LABELED AND PROGRAMMED AT THE CONTROLLER PRIOR TO INSTALLATION. <br />2. DO NOT CREATE DUPLICATE STATION ADDRESSES FOR DECODERS. <br />3. THE TWO WIRE CABLE SHALL BE A SOLID -CORE, COLOR -CODED, TWISTED -PAIR CABLE. <br />4. GROUND ONE DECODER AT THE END OF THE WIRE PATH AND ONE DECODER GROUNDED EVERY 500, <br />OR 8TH DECODER WHICHEVER IS SHORTER. <br />5. BOTH THE CONTROLLER AND DECODER ARE TO BE GROUNDED TO GROUND RODS OR PLATES WITH <br />LESS THAN 10 OHMS RESISTANCE. <br />6. ALL TWO -WIRE SYSTEM COMPONENTS ARE TO BE INSTALLED PER THE HUNTER ACC DECODER <br />SPECIFICATIONS. <br />7. ALL CONNECTIONS AND SPLICES IN THE TWO -WIRE PATH MUST BE MADE WITH DBRY-6 OR EQUAL <br />WATERPROOF CONNECTORS. <br />8. ALL T-SPLICES MUST BE MADE IN VALVE BOXES WITH DBRY-6 OR EQUAL WATERPROOF CONNECTIONS. <br />9. FROM THE DECODER OUTPUTS TO INDIVIDUAL SOLENOIDS, USE STANDARD IRRIGATION WIRE SIZED <br />FOR THE LENGTH OF THE RUN. <br />10. WIRING FROM THE DECODER TO THE SOLENOID SHOULD NOT EXCEED 150 FT. <br />11. WHEN DOUBLING SOLENOIDS ON A DECODER OUTPUT, WIRE THE SOLENOIDS IN PARALLEL RATHER <br />THAN IN SERIES. <br />GENERAL IRRIGATION NOTES <br />1. ALL MAINLINES TO HAVE A MINIMUM OF 18" OF COVER. (CLASS 200 PVC PIPE). <br />2. ALL LATERAL AND SUB -MAIN PIPE TO HAVE A MINIMUM OF 12" OF COVER (CLASS 200 PVC PIPE). <br />3. NO ROCKS, BOULDER, OR OTHER EXTRANEOUS MATERIALS TO BE USED IN BACKFILLING OF TRENCH. <br />4. ALL PIPE TO BE INSTALLED AS PER MANUFACTURERS' SPECIFICATIONS. <br />5. ALL THREADED JOINTS TO BE COATED WITH TEFLON TAPE OR LIQUID TEFLON. <br />6. ALL LINES TO BE THOROUGHLY FLUSHED BEFORE INSTALLATION OF SPRINKLER HEADS. <br />7. SPRINKLER AND RELATED EQUIPMENT TO BE INSTALLED AS PER DETAILS. <br />8. ALL ELECTRICAL JOINTS TO BE MADE USING WATERPROOF CONNECTIONS AS SHOWN ON DETAILS. <br />9. ALL EQUIPMENT NOT SPECIFIED IN THE LEGEND SHALL BE DETERMINED AND FURNISHED BY THE CONTRACTOR. <br />10. NO ELECTRICAL CONNECTIONS SHALL BE MADE IN THE FIELD EXCEPT AT A VALVE CONTROL BOX OR ANOTHER <br />VALVE BOX SPECIFICALLY FOR CONNECTIONS. <br />11. ANY DISCREPANCY BETWEEN THIS SHEET AND OTHERS IN THIS SET MUST BE REFERRED TO THE IRRIGATION <br />CONSULTANT BY THE CONTRACTOR FOR CLARIFICATION BEFORE PRECEDING WITH THE WORK. <br />12, CONTRACTOR TO BE RESPONSIBLE FOR PROPER COVERAGE OF AREAS TO BE WATERED. Le ADJUST HEADS WITH <br />INSUFFICIENT COVERAGE DUE TO BLOCKAGE BY EXISTING OR PROPOSED SITE FEATURES. <br />13. CONTRACTOR TO REFER TO LANDSCAPE PLAN TO KEEP SPRINKLER EQUIPMENT AND ACCESSORY MATERIAL <br />FROM INTERFERING WITH PROPER PLANTING, Le VERIFY ROOT BALL SIZE FOR PLANTING <br />14. CONTRACTOR SHALL PROVIDE EXPANSION COILS AT EACH WIRE CONNECTION IN A VALVE BOX (WRAP AROUND <br />3/4" PIPE 12 TIMES. <br />15. SPRINKLERS IN LOW-LYING AREAS SHALL HAVE CHECK VALVES <br />16. ALL SPRINKLERS TO BE MOUNTED ON FLEX PIPE - REFER TO DETAILS. <br />17. INSTALL DRIP LINE TUBING AND NON -PRESSURE LATERAL LEAD LINE PIPING IN LANDSCAPE AREAS AND <br />ADJACENT TO SELECTED PLANT MATERIAL AS SHOWN IN DETAILS. <br />18. CONTRACTOR SHALL UTILIZE VALVE I.D. TAGS ON ALL REMOTE CONTROL VALVES. <br />19. CONTRACTOR SHALL INSTALL MANUFACTURERS' RECOMMENDATION ON FAULT GROUND AND LIGHTNING <br />PROTECTION. <br />20. ALL MATERIAL TO BE SUPPLIED BY CONTRACTOR TO OWNER: <br />A. TWO WRENCHES FOR DISASSEMBLING AND ADJUSTING EACH TYPE OF SPRINKLER HEAD AND VALVE <br />SUPPLIED. <br />26. SYSTEM IS DIAGRAMMATIC TO IMPROVE CLARITY. ALL MAINLINE PIPING, ELECTRIC VALVES AND WIRING ARE TO <br />BE INSTALLED IN LANDSCAPED AREAS AND REFERENCE THE LANDSCAPE PLAN PRIOR TO THE INSTALLATION OF <br />PIPING TO AVOID CONTACT WITH PLANT MATERIALS EXISTING OR NEW. <br />27. CONTRACTOR TO ADD EXTENSION RISER TO POP-UP HEADS WHEN NEEDED TO PROVIDE PROPER COVERAGE. <br />28. CONTRACTOR SHALL INSTALL SPRINKLER EQUIPMENT 12" FROM FOUNDATIONS, ALSO INSTALL SPRINKLERS 4" <br />FROM CURBS OR WALKS. <br />29. PRIOR TO BID IRRIGATION CONTRACTOR SHALL VERIFY RIGHT-OF-WAY AND BACKFLOW REQUIREMENTS NO <br />LATER THAN FIVE DAYS BEFORE BID SUBMITTALS. CONTRACTOR SHALL NOTIFY CONSULTANT OF ANY CHANGES <br />FROM PLANS OR SPECIFICATIONS. <br />30. IRRIGATION CONTRACTOR SHALL PROVIDE THE OWNER AND LANDSCAPE ARCHITECT WITH A REPRODUCIBLE <br />CROSS MEASURED AS -BUILT DRAWING OF THE INSTALLED IRRIGATION SYSTEM IN AUTOCAD 2010 FORMAT <br />BEFORE FINAL ACCEPTANCE. <br />31. A 1-YEAR WARRANTY PERIOD SHALL BE PROVIDED FOR SYSTEM AFTER SUBSTANTIAL COMPLETION IS ACCEPTED. <br />START UP AND ADJUSTING OF SYSTEM IN SPRING TIME SHALL BE INCLUDED IN WARRANTY. <br />32. PRIOR TO BID, CONTRACTOR SHALL VERIFY THAT ALL MATERIAL, INSTALLATION PARAMETERS AND OPERATIONS <br />CONFORM TO ALL APPLICABLE CODES AND ORDINANCES NO LATER THAN FIVE DAYS BEFORE BID SUBMITTALS. <br />CONTRACTOR SHALL NOTIFY IRRIGATION CONSULTANT/DESIGNER OF ANY CHANGES REQUIRED DUE TO <br />CURRENT CODE OR ORDINANCE DISCREPANCIES. IF CONTRACTOR DOES NOT COMPLY TO THIS NOTIFICATION, <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY INSTALLATION CHANGE AND REDESIGN COSTS <br />FOR NON-COMPLIANCE. <br />33. UNLESS OTHERWISE NOTED, THE CONTRACTOR MUST COMPLETE TWO PRESSURE TESTS OF THE IRRIGATION <br />SYSTEM MAINLINE(BOTH TO SHOW NO DROP IN PRESSURE DURING DURATION OF THE TEST). <br />A. 2-HOUR PRESSURE TEST AT 1.5 TIMES THE SYSTEM STATIC PRESSURE <br />B. 24-HOUR PRESSURE TEST AT THE SYSTEM STATIC PRESSURE <br />34. IRRIGATION INSTALLATION CONTRACTOR SHALL PROVIDE THE OWNER WITH A COLOR -CODED ZONE DIAGRAM <br />PLAN, 8-1/2"X1 1"LAMINATED SHEET(S) TO IDENTIFY CONTROLLER STATION TO THE CONTROL VALVE NUMBER FOR <br />EACH CONTROLLER. CHART IS TO BE LOCATED IN AN ADHESIVE POUCH ATTACHED TO THE INSIDE OF <br />CONTROLLER(S). <br />35. THE CONTROLLER(S) SHALL SCHEDULE PROGRAM "A" TO A REGULAR RUN-TIME SETTINGS FOR AFTER THE <br />ESTABLISHMENT PERIOD OF THE PLANT MATERIAL. PROGRAM "B" SHALL BE USED DURING THE ESTABLISHMENT <br />PERIOD AND TURNED OFF AFTER THE 30-60 DAYS OF PLANT INSTALLATION. <br />36. THE IRRIGATION CONTRACTOR WILL READ ALL SPECIFICATIONS AND REVIEW ALL DETAILS AND EXAMINE THESE <br />PLANS CAREFULLY PRIOR TO BIDDING THIS PROJECT. FAILURE TO READ THIS INFORMATION IS NOT AN <br />ACCEPTABLE REASON IF THE JOB IS UNDERBID. <br />37. THE PLAN MAY NOT INCLUDE ALL MATERIALS. THIS DOESN'T RELIEVE THE CONTRACTOR FROM BEING <br />RESPONSIBLE TO PROVIDE A COMPLETE SYSTEM IN PERFECT WORKING ORDER. <br />IRRIGATION SYSTEM PERFORMANCE NOTES <br />1. IRRIGATION SYSTEM IS DESIGNED TO OPERATE OFF AN EXISTING DEEP WELL PUMP SYSTEM PROVIDING A MINIMUM <br />FLOW OF 40 GPM AND A MINIMUM PRESSURE OF 45 PSI. <br />CONTRACTOR MUST CONTACT THE LANDSCAPE ARCHITECT PRIOR TO THE COMMENCEMENT OF ANY <br />CONSTRUCTION IF THE AVAILABLE FLOW AND PRESSURE DEVIATES MORE THEN 5% OR WILL AFFECT THE <br />PERFORMANCE OF THE SYSTEM. <br />MINIMUM PRESSURE REQUIREMENTS - 45 PSI AT THE POINT OF CONNECTION <br />A. 30 PSI AT THE BASE OF THE POP-UP SPRAY HEADS <br />2. HEAD LAYOUT IS BASED ON BASE INFORMATION PROVIDED. HEADS SHALL BE ADJUSTED TO ACCOMMODATE FIELD <br />VARIATIONS WHILE MAINTAINING 100% COVERAGE AND MINIMIZING OVER -SPRAY ONTO PAVED AREAS AND <br />BUILDINGS. <br />3. Y" PIPE SHALL NOT BE USED FOR LATERAL PIPING <br />4. WITH A WELL AS A WATER SOURCE THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING WATER <br />SAMPLES FROM THE WELL AT THE IRRIGATION CONTRACTORS EXPENSE, HE SHALL HAVE A CERTIFIED LAB <br />ANALYZE THE WATER QUALITY. THE IRRIGATION CONTRACTOR SHALL REPORT TO THE LANDSCAPE ARCHITECT OR <br />OWNER'S PROJECT MANAGER, ANY POTENTIAL ISSUES THAT MAY AFFECT THE HEALTH OF THE PLANT MATERIAL <br />OR POTENTIAL STAINING TO SIDEWALKS AND BUILDINGS. REPORTING SHALL OCCUR BEFORE THE SYSTEM IS IN <br />OPERATION. FAILURE TO REPORT SHALL PLACE LIABILITY ON THE IRRIGATION CONTRACTOR. <br />1O FINISH GRADE/TOP OF MULCH <br />2O JUMBO VALVE BOX WITH PURPLE COVER: <br />RAIN BIRD VBJMBPL <br />3O 30-INCH LINEAR LENGTH OF WIRE, COILED <br />4O WATERPROOF CONNECTION: <br />RAIN BIRD DB SERIES <br />O 1 1/2" PESB-R VALVE (INCLUDED IN XCZ-150-LCDR <br />KIT) <br />O 1 1/2" SCH 40 ADAPTER (MALE X FEMALE) <br />INCLUDED IN XCZ-150-LCDR KIT <br />O 1 1/2" FILTER - RAIN BIRD LARGE CAPACITY DISC <br />FILTER (INCLUDED IN XCZ-150-LCDR KIT) <br />Og 1 1/2" HIGH FLOW PRESSURE REGULATOR <br />(INCLUDED IN XCZ-150-LCDR KIT) <br />O LATERAL PIPE <br />10 PVC SCH 80 NIPPLE 1 1/2" <br />11 PVC SCH 40 ELBOW <br />12 PVC SCH 80 NIPPLE (2" LENGTH, HIDDEN) AND <br />PVC 40 ELBOW <br />13 PVC SCH 40 TEE OR ELBOW <br />14 MAINLINE PIPE <br />15 3" MINIMUM DEPTH OF 3/4" WASHED GRAVEL <br />RAIN BIRD XCZ-150-LCDCR 1.5" COMMERCIAL CONTROL ZONE KIT IN JUMBO VALVE BOX <br />1O 30" LINEAR LENGTH OF WIRE, <br />COILED <br />O2 WATERPROOF CONNECTION <br />RAIN BIRD SPLICE-1 (1 OF 2) <br />OID TAG: RAIN BIRD VID SERIES <br />OREMOTE CONTROL VALVE: <br />RAIN BIRD PESB <br />OVALVE BOX WITH COVER <br />RAIN BIRD VB-STDP <br />OFINISH GRADE/TOP OF MULCH <br />OPVC SCH 80 NIPPLE (CLOSE) <br />O8 PVC SCH 40 ELL <br />Og PVC SCH 80 NIPPLE <br />(LENGTH AS REQUIRED) <br />10 BRICK (1 OF 4) <br />11 PVC MAINLINE PIPE <br />12 SCH 80 NIPPLE (2" LENGTH, <br />HIDDEN) AND SCH 40 ELL <br />13 PVC SCH 40 TEE OR ELL <br />14 PVC SCH 40 MALE ADAPTER <br />15 PVC LATERAL LINE <br />16 3" MINIMUM DEPTH OF <br />WASHED GRAVEL <br />ELECTRIC REMOTE CONTROL VALVE - PESB SERIES <br />Z <br />P <br />a <br />�2 <br />U <br />w01 <br />Z <br />aw>-cn-Ozcn <br />Z <br />Q <br />C5 <br />cN� 14 <br />Lu <br />QO <br />o <br />2: <br />44z CD <br />r; <br />V <br />r;O <br />2 O <br />d <br />a <br />a <br />o <br />�Q ..........•: C <br />zir <br />J Ilgi <br />Or 40 <br />yj <br />w01559 �y m <br />:Q �1 n <br />CC 1 0 2 z � <br />a011 <br />J In <br />� M 00 <br />W M CIO <br />O Ce PQT <br />0 <br />C, Z o 0 v- <br />LU <br />W <br />0 z <br />M 2 <br />M Q <br />M LLLLJ..II <br />U <br />S <br />H <br />E <br />E <br />T 12 <br />N <br />0 <br />