GASKET & WEATHERSEAL <br />ROOFTO UNI �. <br />)RAIN PAN A <br />1i" HOLE DRILLED IN CAP FOR CLEAN <br />OUT AND VENTING OF DRAIN PIPING. <br />ROUTE AS SHOWN ON <br />FLOOR PLAN. <br />X <br />DUCT <br />X=3"MIN. P-TRAP <br />FACTORY CURB <br />• <br />PIPE SIZE AS REQUIRED <br />SEE DRAWINGS <br />DECK PLATE, RIGID 18 <br />GA, STAINLESS STEEL, <br />MIRO INDUSTRIES MODEL <br />DP-12-SS, SIZE 12" SQ. <br />PILLOW BLOCK PIPE STAND <br />OF POLYCARBONATE RESIN <br />MATERIAL, MIRO INDUSTRIES <br />MODEL 3-R <br />PILLOW BLOCK PIPE <br />STAND ---- <br />PLAN <br />ROOF INSULATION <br />ROOF DECK <br />COUNTERFLASHING <br />STRIP. <br />DECK PLATE <br />i i l i i i <br />ROOFING MATERIAL <br />ELEVATION <br />CENTER DECK PLATE BELOW <br />PIPE STAND <br />DRAINAGE PORTS ON TWO <br />SIDES OF PIPE STAND BASE <br />PROVIDE ALUMINUM PIPE <br />STRAPS, FASTEN TO PIPE <br />STAND WITH STAIN STEEL <br />SCREWS <br />PIPE SHALL REST FIRMLY ON <br />PIPE STAND WITHOUT GAPS <br />PIPE STANDS ARE STACKABLE <br />FOR PROPER ELEVATION OF <br />VARIOUS SIZE PIPE TO <br />MAINTAIN LEVEL PIPING, NO <br />SHIMS OR BLOCKS ARE <br />ALLOWED <br />SUPPORT SPACING FOR PIPE SUPPORTS SHALL BE 4'-0" ON CENTER. <br />PLACE DECK PLATES ON ROOFING, SET PIPE STAND FREE ON DECK <br />PLATES. STACK PIPE STAND WHERE REQUIRED TO ELEVATE PIPING. <br />Q <br />0 <br />LO <br />0 <br />co <br />x <br />0 <br />X <br />0 <br />Y <br />N <br />L <br />O <br />co <br />-I <br />a. <br />co <br />T <br />r <br />co <br />0 <br />N- <br />N <br />m. <br />0 <br />N <br />M <br />T <br />U') <br />0 <br />0 <br />Q <br />U <br />H <br />E <br />LL <br />V) <br />ca <br />M <br />ti <br />ROOFTOP UNIT <br />GASKET AND SILICONE <br />SEALING <br />BASE RAIL ON UNIT - <br />PRESSURE -TREATED <br />WOOD NAILER STRIP - <br />CURB HEIGHT = 8" MIN <br />FACTORY CURB: NRCA APPROVED, <br />18 GAGE, SQUARE WITHIN 1/8" <br />ON DIAGONAL MEASUREMENT, WITH <br />A MINIMUM OF 8" ABOVE TOP OF <br />nnnr <br />CURB SET DIRECTLY ON STEEL - <br />3i8"x6" LAG BOLTS THROUGH UNIT <br />RUNNER, WOOD NAILER AND CURB <br />FRAME. PROVIDE 3 PER LONG <br />SIDE AND 2 PER SHORT SIDE. <br />- -COUNTER FLASHING STRIP <br />--1" RIGID INSULATION <br />_-3" CANT STRIP <br />';';' ROOF INSULATION <br />METAL DECKING <br />BOLT SETS: 1/2", (2) PER SIDE, <br />THRU BASE OF CURB AND FRAME <br />1700 LBS. TENSION, 2200 LBS. <br />HEAR CAPACITY.) <br />STRUCTURAL SUPPORT FRAME <br />FOR UNIT & DECKING AT FULL <br />PERIMETER OF FACTORY CURB <br />1. MECHANICAL SUBCONTRACTOR SHALL FURNISH ROOF OPENING SIZES & LOCATIONS, <br />FOR STRUCTURAL SUPPORT FRAMING BY GENERAL CONTRACTOR. <br />2. CURB SHALL BE MANUFACTURED WITH SLOPING BASE TO MATCH ROOF PITCH AND <br />LEVEL TOP. <br />3. ALTERNATE METHODS OF TIE -DOWN FOR ROOF TOP EQUIPMENT SHALL BE APPROVED <br />BY THE STRUCTURAL ENGINEER PRIOR TO COMMENCEMENT OF WORK OR EQUIPMENT <br />ORDER. <br />4. SYSTEM SHALL BE CAPABLE OF WITHSTANDING WIND FORCE IN ACCORDANCE WITH <br />THE 2010 FLORIDA BUILDING CODE AND OTHER APPLICABLE CODES. (TIE -DOWN SYSTEM <br />HAS BEEN DESIGNED FOR 146 MPH WIND FORCE MINIMUM), <br />HANGER SUPPORTS: <br />8'O.C. = 0-35" DUCTS <br />6'O.C. = 36-59" DUCTS <br />SIZES HO <br />ARE F <br />ARE <br />• <br />SPIN -IN FITTING: <br />WITH SCOOP AND <br />DAMPER, EXCEPT <br />IN GYP, BOARD <br />CEILINGS, DAMPER <br />IN NECK <br />I <br />L_ <br />MINIMUM RADIUS EQUAL <br />TO THE FLEX DUCT <br />DIAMETER <br />SADDLE: 22 GAGE <br />HANGER STRAP: 1.5", 22 GAGE <br />ON 5' MAX. SPACING (TYPICAL) <br />ROUND "SNAPLOCK" SHEET METAL <br />FOR RUN -OUTS GREATER THAN 6', <br />WITH 2" WRAP INSULATION <br />FLEXIBLE DUCT: <br />INSULATED, MAXIMUM <br />6', DO NOT SAG OR <br />KINK <br />WRAP INSULATION ABOVE CEILING DIFFUSER <br />CEILING DIFFUSER <br />NOTES: <br />1• HANGER SUPPORTS SHALL BE AS NOTED ABOVE FOR DUCTS UP TO 24", AND WITH TRAPEZE <br />HANGERS FOR DUCTS 25" AND ABOVE. <br />2. ELBOWS SHALL BE SQUARE NECK (SAME IN AND OUT DIMENSION) WITH 2" DOUBLE THICKNESS <br />TURNING VANES. <br />3. OFFSETS SHALL NOT EXCEED 30 DEGREE ANGLE, AND SHALL NOT REDUCE THE FREE AREA <br />OF THE DUCT. <br />4. TRANSITIONS SHALL NOT EXCEED 1:3 RATIO (4" TRANSITION PER FOOT SINGLE SIDED <br />TRANSITION, AND 8" PER FOOT DOUBLE SIDED TRANSITION), <br />5. RECTANGULAR BRANCH CONNECTIONS SHALL BE 45 DEGREE ENTRY TYPE, WITH METAL SLEEVE <br />& CLINCH LOCK CONNECTION. ENTRY LENGTH SHALL BE 25% OF BRANCH DUCT WIDTH. <br />6. ROUND BRANCH DUCT CONNECTIONS SHALL BE WITH "FLEXMASTER" FLDE SPIN -IN FITTINGS, <br />WITH SCOOP, DAMPER AND HANDLE. <br />7. FLEXIBLE ROUND DUCT SHALL INCLUDE: HELIX COIL FLEXIBLE DUCTING, A 1-1/2" BLANKET <br />INSULATION WITH MINIMUM 6.0 R VALUE, AND A ALUMINUM FOIL OUTER VAPOR BARRIER, <br />AND BE UL-181 APPROVED, 25 OR LESS FLAME SPREAD AND 50 OR LESS SMOKE DEVELOPED. <br />EQUAL TO "FLEXMASTER" TYPE 3M. <br />CONCEALED FIBERGLASS DUCT DETAIL <br />SCALE: NONE <br />RTU SCHEDULE <br />MARK <br />--- <br />RTU-1 <br />RTU-2 <br />MANUFACTURER <br />--- <br />TRANE <br />TRANE <br />MODEL <br />--- <br />TSC092 <br />TSC072 <br />SUPPLY AIR <br />CFM <br />3000 <br />2400 <br />OUTSIDE AIR <br />CFM <br />250 <br />200 <br />CAPACITY <br />TONS <br />7.5 <br />6.0 <br />TOTAL COOLING <br />MBH <br />92.0 <br />72.0 <br />SENSIBLE COOLING <br />MBH <br />79.0 <br />61.0 <br />EXTERNAL STATIC PRESSURE <br />IN H2O <br />0.8 <br />0.8 <br />ELECTRIC HEAT (208V) <br />KW/STEP <br />20.3/2 <br />20.3/2 <br />EVAPORATOR FAN <br />BHP/FLA <br />1.5/3.6 <br />1.5/5.0 <br />COMPRESSOR <br />NO/RLA <br />2/14.5 <br />1/22.4 <br />CONDENSING FAN <br />NO/FLA <br />1/4.0 <br />1/3.85 <br />ELECTRICAL DATA <br />V/PH/HZ <br />208/3/60 <br />208/3/60 <br />MCA <br />AMPS <br />74.9 <br />76.6 <br />FUSE/MOCP <br />AMPS <br />80 <br />80 <br />EFFICIENCY <br />SEER/EER <br />--/11.2 <br />--/11.2 <br />WEIGHT <br />LBS, <br />1800 <br />1400 <br />NOTES <br />--- <br />1-16 <br />1-16 <br />NOTES <br />1. TRAP CONDENSATE DRAIN AT UNIT (FULL SIZE OF OPENING) MIN. 3" WATER <br />SEAL AND EXTEND AS SHOWN. <br />2. ALL UNITS SHALL BE SUPPLIED WITH COMPLETE TEMPERATURE CONTROLS AND <br />AUTOMATIC CHANGEOVER. <br />3. ALL CAPACITIES AT A.R.I. CONDITIONS. <br />4. PROVIDE WITH FACTORY FABRICATED EXTENDED HEIGHT INSULATED ROOF CURB <br />WITH SLOPED BASE TO MATCH ROOF PITCH AND SET TOP LEVEL. <br />5. ALL OUTSIDE AIR INTAKES SHALL HAVE MOTORIZED VOLUME DAMPERS. <br />6. PROVIDE SINGLE POINT POWER CONNECTION. <br />7. PROVIDE DUCT TRANSITIONS FROM THE SUPPLY AND RETURN DUCT OPENINGS TO <br />THE DUCT SIZES SHOWN ON THE DRAWINGS. <br />8. HVAC CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL ELECTRICAL <br />COSTS WHICH MAY RESULT FROM SUBSTITUTED EQUIPMENT. <br />9. PERMANENTLY IDENTIFY ALL SYSTEMS WITH THE ROOF TOP UNIT DESIGNATION <br />AND SPACE NUMBER SERVED, <br />10. INSTALL FILTERS IN UNIT PRIOR TO STARTUP AND PROVIDE NEW SET OF <br />FILTERS AT COMPLETION OF CONSTRUCTION PRIOR TO TEST AND BALANCE. <br />11. ELECTRICAL POWER AND CONTROL CONDUITS SHALL RISE UP INSIDE THE CURB <br />OF THE RTU. <br />12. DISCONNECT SWITCH SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. <br />13. CONVENIENCE OUTLET SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. <br />14. APPROVED ALTERNATE MANUFACTURERS: CARRIER AND YORK/JCI <br />15. PROVIDE SUPPLY AIR SMOKE DETECTOR. <br />16. PROVIDE WITH HINGED ACCESS DOORS. <br />FAN SCHEDULE <br />MARK <br />--- <br />EF-1 & 2 <br />EF-3 <br />MANUFACTURER <br />--- <br />GREENHECK <br />GREENHECK <br />MODEL <br />--- <br />SP-All0 <br />SP-A200 <br />SERVICE <br />--- <br />RESTROOMS <br />FILE ROOM <br />AIR QUANTITY <br />CFM <br />75 <br />150 <br />EXTERNAL STATIC PRESSURE <br />IN H2O <br />0.375 <br />0.375 <br />FAN TYPE <br />--- <br />CENTRIFUGAL <br />CENTRIFUGAL <br />MAXIMUM FAN SPEED <br />RPM <br />950 <br />850 <br />DRIVE <br />--- <br />DIRECT <br />DIRECT <br />MOTOR <br />HP(W) <br />49 W <br />48 W <br />ELECTRICAL <br />V/PH/HZ <br />115/1/60 <br />115/1/60 <br />CONTROLS <br />--- <br />W/ LIGHTS <br />W/ LIGHTS <br />SONES <br />--- <br />1.2 <br />3.2 <br />WEIGHT <br />LBS. <br />15 <br />25 <br />NOTES <br />--- <br />1 THRU 5 <br />1 THRU 5 <br />NOTES <br />1. PROVIDE FACTORY MOUNTED DISCONNECT SWITCH. <br />2. PROVIDE WITH AUTOMATIC BACKDRAFT DAMPER. <br />3. PROVIDE WALL CAP WITH BIRD SCREEN. <br />4. PROVIDE WITH SOLID STATE SPEED CONTROLLER. <br />5. APPROVED ALTERNATE MANUFACTURER: COOK. <br />BUILDING DESIGN TEMPERATURES <br />DESIGN AREA <br />SUMMER DESIGN <br />WINTER DESIGN <br />OUTSIDE <br />INSIDE <br />OUTSIDE <br />INSIDE <br />DB <br />WB <br />DB <br />WB <br />DB <br />DB <br />WB <br />BUILDING <br />93 <br />77 <br />75 <br />64 <br />40 <br />70 <br />55 <br />OUTSIDE AIR CALCULATION SCHEDULE <br />SPACE <br />OCCUPANCY <br />OCCUPANCY <br />REQUIREMENT <br />GROSS/NET <br />AREA (sq.ft.) <br />AREA <br />REQUIREMENTS <br />REQUIRED CFM <br />PROVIDED CFM <br />NOTES <br />SALES <br />20 PEOPLE <br />7.5 CFM/PERSON <br />3,800/1,950 <br />0.12 CFM/sq.ft. <br />384 <br />400 <br />1 THRU 2 <br />STORAGE <br />--7 <br />7.5 CFM/PERSON <br />160 <br />0.12 CFM/sq.ft, <br />20 <br />50 <br />1 THRU 2 <br />NOTES <br />1. THE OUTSIDE AIR WAS CALCULATED USING NET OCCUPIABLE SPACE. <br />2. OUTSIDE AIR CALCULATIONS BASED ON ASHRAE 62.1-2007 <br />AIR DISTRIBUTION SCHEDULE <br />MARK <br />MANUFACTURER <br />MODEL <br />TYPE <br />MATERIAL <br />NOTES <br />CD1 <br />PRICE <br />ASCD <br />CEILING DIFFUSER, LAY -IN <br />ALUMINUM <br />1-6 <br />RG1 <br />PRICE <br />630 <br />RETURN GRILLE, LAY -IN <br />ALUMINUM <br />1, 2, 3, 5, 6 <br />TG1 <br />PRICE <br />630 <br />TRANSFER GRILLE, LAY -IN <br />ALUMINUM <br />1, 2, 6 <br />NOTES <br />1. NOISE CRITERIA NOT TO EXCEED 25. <br />2. CONTRACTOR TO COORDINATE BORDER WITH CEILING TYPE. <br />3. REFER TO FLOOR PLAN FOR CFM. <br />4. AIR DEVICES ARE 4-WAY THROW (UNLESS NOTED OTHERWISE ON DRAWING). <br />5. PROVIDE MANUAL VOLUME DAMPER AT MAIN TRUNK TAKEOFF FOR BALANCING. <br />6. APPROVED ALTERNATE MANUFACTURERS: TITUS AND METAL AIRE <br />Job Number: 65173 <br />Colwill Engineering <br />Consulting Engineers, Inc. <br />Engineering Business No. 9021 <br />4750 East Adamo Drive Tampa, Florida 33605 <br />Tel: 813-241-2525 Fax: 813-241-2424 <br />© 2013 ALL RIGHTS RESERVED <br />♦�`�,`EP H' R. <br />8186 <br />:cc► <br />Off. -7P2: <br />���� F •, O R 1 G� ♦♦� <br />Ai E, .�`�♦ <br />Joseph R. Stolz, <br />P.E. No.58186 <br />Revisions: <br />Date Description <br />0 <br />O M <br />M <br />�d <br />0 <br />Wo <br />�x <br />U <br />U <br />U <br />W <br />w <br />� <br />A <br />Z <br />W <br />a <br />It <br />M <br />o <br />a <br />a <br />H <br />H <br />a <br />w <br />� <br />0 <br />� <br />O <br />0 <br />Q <br />0 <br />a <br />x <br />a <br />w <br />Job Number: <br />12049.01 <br />File name: <br />Issued Date: <br />07.17.13 <br />Drawn by: <br />DC/LO <br />Checked by: <br />JS <br />SHEET NAME <br />MECHANICAL <br />SCHEDULES& <br />DETAILS <br />SHEET NUMBER <br />M-2.0 <br />