My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Advance Water Treatment Upgrade
Zephyrhills
>
Building Department
>
Building Plans
>
Advance Water Treatment Upgrade
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 4:44:02 PM
Creation date
2/18/2025 3:27:00 PM
Metadata
Fields
Template:
Building Plans
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOTTED: 3/25/2020 03:17 PM DAVID <br />® Jones Edmunds <br />Cr) <br />31 <br />Q <br />C•i <br />O <br />N <br />to <br />CV <br />0 <br />0 <br />W <br />Q <br />00 <br />co <br />1 <br />cp <br />S11 <br />T/ FLOOR EL, <br />SEE "Co DWGS <br />PREPARED <br />SUBGRADE BELOW <br />CAST -IN -PLACE SLAB <br />711 N ORANGE AVE, STE A <br />WINTER PARK, FL 32789 <br />PH: 321.972.4989 <br />W EK I VA WEIWA PRO.I. NO.18-169 <br />FL ENG BUSINESS NO.319M <br />ENGINEERING <br />20'-0" <br />OPENINGS <br />COORD <br />W/ MANUF <br />TYP <br />EQUIP A <br />MCC <br />PAD, TYP S16 <br />ROOM T/ FLOOR EL <br />102 SEE "C" DWGS <br />PRECAST BUILDING <br />SLAB SET ON 8" SLAB <br />REINF W/ #4AT8', EW, <br />W/ 2" COVER TO TOP <br />OPENINGS <br />COORD <br />W/ MANUF <br />MCC BUILDING <br />PLAN <br />1/4" =1'-0" <br />SEE NOTE 3 FOR INTERIOR <br />WALL INSULATION AND <br />FINISHING <br />T/ FLOOR EL, <br />SEE "C" DWGS <br />GRAPHIC SCALE <br />o i l a s <br />SCALE IN FEET <br />SEE NOTE 3 FOR <br />INTERIOR WALL <br />INSULATION AND <br />FINISHING <br />CONDUIT CAST -IN TO <br />WALL AS NEEDED PER <br />BUILDING MANUF <br />NOTES: <br />1. TOTAL OF TWO (2) 4A 60B-C HALOTRON 1 FIRE EXTINGUISHERS SHALL BE PROVIDED <br />AT EACH DOOR- <br />2. COORDINATE ALL OPENINGS WITH OTHER DISCIPLINES. <br />3. WALLS AND CEILING SHALL BE INSULATED W/ RIGID BOARD INSULATION PROVIDING A <br />MINIMUM R VALUE OF R 21 FOR CEILING AND R-11 FOR WALLS. THE WALLS AND <br />CEILING SHALL BE FURRED WITH LIGHT GAUGE STEEL wr FURRING AT 16" O.C. <br />MAXIMUM SPACING AND COVERED WITH 51W GYPSUM BOARD. GYPSUM BOARD SHALL <br />BE PREPARED FOR PAINTING (MUD AND TAPE). <br />4. PROVIDE FULLY ADHERED 6" VINYL BASE TRIM (COLOR SELECTED BY OWNER) <br />AROUND ENTIRE PERIMETER WALLS. <br />5. DX INDICATES DOOR MARK, SEE SCHEDULE ON SHEET S12. <br />Q <br />O <br />SET PRECAST SLAB IN BED OF 00o <br />MORTAR OR GROUT TO <br />ACHIEVE UNIFORM BEARING r— —7 <br />SECTION 1 <br />1Y2'=1'-0' S11 <br />DESU01 D.MORRIS <br />oRPM D.MORRIS <br />LX DATE REVISIONS BY APPRD. CHEgcED J.SOBCZAK <br />B THKXEND SLAB <br />jfi <br />nesE mnJou <br />CERTIFICATE OF AUTHORIZATION *1841 <br />730 NE WALDO ROAD, GAINESVILLE, FLORIDA 32641 / (3S2) 377-5821 <br />324 S HYDE PARK AVE, SUITE 250, TAMPA, FLORIDA 33606 / (813) 258-0703 <br />NORTH <br />ELEVATION <br />1/4" =1'4r <br />2' SLOPE r SLOPE <br />EAST <br />ELEVATION <br />WASTEWATER TREATMENT FACILITY <br />ADVANCED WATER TREATMENT UPGRADE <br />CITY OF ZEPHYRHILLS, FLORIDA <br />s <br />C <br />C <br />MCC BUILDING <br />PLAN, SECTION AND ELEVATIONS <br />SOUTH <br />ELEVATION <br />2" SLOPE <br />1/4" =1'-O" <br />DRIP CAP 2" SLOPE <br />WEST <br />ELEVATION <br />1/4" =1'-0" <br />DAVID S. MORRIS <br />P.E. #74717 <br />WALL MOUNTED <br />A/C UNIT PER <br />SPECIFICATIONS <br />PROW W. DAM <br />26110-025-01 MARCH 2O20 <br />ow W. DWG W. <br />S11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.