My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36512 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36512 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 3:29:19 PM
Creation date
2/18/2025 3:56:15 PM
Metadata
Fields
Template:
Building Plans
Street #
36512
Location
Garden Wall Way
Contractor
Lennar
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />M <br />20C <br />15C <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.�� <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp <br />NOTE: ELECTRICAL MATERIAL AND <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UT <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring 8t accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped With a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range Is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FfF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f.Oh <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />P4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />�144/� <br />G J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />PANEL CENTER <br />10 J114 to fights d oudets <br />NEMA 1 10 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP 10 #10 t0 WH <br />01 G <br />ate to Range <br />10 1'6toHVAC <br />FIRST FLOOR ELECTRICAL PLAN - ELEV-B1 <br />SCALE: Y4"=1'-0" <br />M <br />C%-! <br />C= <br />N <br />N <br />c <br />m <br />Lib: <br />U_ <br />o <br />a r_ o <br />r_i <br />m <br />r C �•�- d <br />w d o to <br />3 at at <br />I: t <br />3 � <br />m a, Zj o <br />u m <br />c o <br />�) <br />ra <br />H E <br />c <br />� o <br />C1. u <br />Q <br />M <br />fV <br />N <br />1 <br />CV <br />0 <br />To the best of the Engineers knowledge. Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code <br />Residential <br />7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's <br />signature and seal. <br />W <br />14 <br />PV <br />;��;.L <br />Ste_ <br />,a <br />g' m <br />i <br />rA <br />r� N V 9a t�L <br />Z <br />0 <br />- rT a <br />t mC0 <br />W <br />,G00 <br />M`�' <br />� <br />w <br />W <br />Z <br />CP m <br />Cl) d <br />Z <br />N O U <br />W(D <br />to <br />❑❑ <br />Z <br />z <br />Cf)d <br />J <br />;7 <br />Y] <br />N <br />z <br />+� <br />'2 <br />Cn <br />0 <br />w <br />tz <br />UlLn <br />c <br />Q <br />�ITO <br />N <br />2 <br />Q <br />LLo <br />ao <br />aLL <br />0R, <br />p <br />U <br />k� <br />z® <br />as <br />c� <br />ao <br />U <br />Z <br />Z <br />co no <br />ado <br />o� <br />v' c <br />0 <br />ZJ <br />8 <br />a ° <br />zz <br />5° <br />g <br />zf <br />az <br />Ln <br />W <br />p <br />t <br />a <br />=1 <br />° <br />r <br />= <br />L <br />LID <br />QL <br />� <br />H <br />r <br />co <br />ro <br />.Y <br />M <br />r <br />m <br />V <br />c <br />L / <br />D M <br />COI <br />-� <br />C7 cV <br />N <br />C) <br />Q� <br />CMN <br />T_ N <br />Ln <br />M <br />Q <br />LO <br />CD <br />r <br />E <br />C_ <br />r- <br />M <br />o <br />z <br />E O <br />h <br />a <br />U <br />a p <br />JOB <br />NO: <br />23-00521 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />