Laserfiche WebLink
— t I <br />— — ' II I IL_r 1 a 2i __' +r I I I — — I 1 —11 1 1— <br />® WOOD STRUCTURAL PANEL (PLYWOOD) MFOUNDATION ® GENERAL CODES I <br />U <br />a <br />Cr) <br />N <br />0 <br />a <br />N <br />0 <br />a� <br />0 <br />3 <br />a <br />co <br />L0 <br />N <br />E <br />g <br />0 <br />U <br />0 <br />a <br />rl- <br />co <br />LO <br />N <br />Un <br />Cn <br />01 PLYWOOD USED FOR ROOF SHEATHING SHALL BE 5/8" APA RATED SHEATHING, EXP. 1, APA IDENTIFICATION 01 FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF. SHOULD <br />INDEX 32/16, OR BETTER. CONDITIONS VARY FROM THE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF <br />WORK, <br />02 PLYWOOD SHALL BE NAILED TO JOISTS AS PER ROOF FASTENING ZONE PLAN. <br />02 ALL FOOTINGS SHALL BE PLACED DIRECTLY ON VIRGIN SOIL, OR CERTIFIED COMPACTED FILL. <br />03 USE PLYCLIPS OR OTHER EDGE SUPPORTS FOR ALL PLYWOOD SHEATHING. <br />03 CONCRETE FOR FOUNDATIONS: <br />04 PLACE FACE GRAIN IN DIRECTION OF SPAN (TRANSVERSE TO JOIST OR TRUSS SPAN). A 28 DAY COMPRESSIVE STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS: <br />FOOTINGS 3000 PSI <br />05 LEAVE 1/16" SPACE AT ALL. PLYWOOD PANEL END JOINTS AND 1/8" SPACE AT ALL PANEL EDGE JOINTS. SLAB ON GRADE 3000 PSI <br />WALLS 3500 PSI <br />B MAXIMUM CONCRETE SLUMP SHALL BE 4". <br />C SLAB ON GRADE SHALL BE 5" THICK WITH WWF 6 x 6 -W1.4 x W1.4. SLAB SHALL BE FINISHED IN <br />MICROLLAM@ OR PARALLAM® BEAMS ACCORDANCE WITH ACI STANDARD 302 FOR CLASS 2 FLOORS. IN LIEU OF WWF, SLAB ON GRADE MAY <br />01 MICROLLAM@ OR PARALLAMO BEAMS ARE INDICATED ON DRAWINGS AS:LVL OR PSL. CONSIST OF FIBER REINFORCED CONCRETE ACI 544.2R-89. <br />D ALL CONCRETE SHALL BE MIXED, TRANSPORTED AND PLACED IN ACCORDANCE WITH ACI STANDARDS <br />02 MICROLLAMO BEAMS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: 318, 304 AND 301. <br />E _ 1.9 X 10"6 PSI E ALL REINFORCING BARS SHALL BE OF BILLET STEEL CONFORMING TO ASTM A615, GRADE 60. <br />FB — 2,600 PSI F ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185. <br />FT = 1,555 PSI G ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS AND FOOTINGS. <br />FC = 750 PSI H REINFORCING STEEL SHALL BE PACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER: <br />FC, PARALLEL = 2,510 PSI SLAB ON GRADE 1-1/2" <br />FV = 285 PSI WALLS 2" <br />FOOTINGS 3" <br />03 BEAMS MUST BE LATERALLY SUPPORTED AT TOP. I GRADE BEAMS SHALL BE FORMED ON SIDES. <br />04 MINIMUM BEARING LENGTH SHALL BE MINIMUM OF 1-1/2" AT ENDS AND 3-1/2" AT INTERMEDIATE SUPPORTS. 04 ALL FILL SHALL BE PLACED IN 8 INCH LOOSE LIFTS (MAXIMUM) COMPACTED WITH VIBRATORY ROLLERS. FILL <br />MATERIAL SHALL BE TESTED BY MODIFIED PROCTOR DENSITY METHOD (ASTM D1557) AND MUST QUALIFY AS <br />05 MULTIPLE MEMBERS SHALL BE FASTENED TOGETHER IN ACCORDANCE WITH MANUFACTURER'S SELECT, WITH LESS THAN 10% PASSING THROUGH THE NO.200 SIEVE. SOIL SHALL BE PLACED WITH MOISTURE <br />SPECIFICATIONS. CONTENT AND ENERGY TO PROVIDE 98% OF MAXIMUM DRY DENSITY BELOW SLABS ON GRADE, AND SOIL <br />SHALL BE COMPACTED TO 98 /012 AND 24 BELOW STRIP FOOTINGS AND COLUMN FOOTINGS, RESPECTIVELY. <br />IN PLACE DENSITY TESTS SHALL BE TAKEN FOR EACH 2,000 S.F. IN EACH LIFT. FOR ACCEPTANCE OF SOIL, <br />® TRUSSES AVERAGE OF DENSITY TESTS MUST EXCEED THE SPECIFIED COMPACTION. NO TESTS SHALL BE PERMITTED <br />01 SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL OF ALL WOOD TRUSSES. TO FALL BELOW 90% COMPACTION. <br />02 SHOP DRAWINGS SHALL SHOW CHORD AND WEB SIZES, STRENGTHS, STIFFENERS (AS REQUIRED), BEARING 05 ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 2'-0" BELOW FINAL GRADE WHEN BEARING ON SOIL, <br />DETAILS, BRIDGING, BRACING, ERECTION NOTES AND DESIGN CALCULATIONS. TRUSSES SHALL BE DESIGNED UNLESS NOTED OTHERWISE ON THE FOUNDATION DRAWINGS. <br />TO MEET THE DESIGN LOADS SHOWN ON THE STRUCTURAL NOTES AND PLANS. MAXIMUM LIVE LOAD <br />DEFLECTION SHALL BE LESS THAN 1/240 OF THE SPAN. MAXIMUM DEFLECTION UNDER FULL DESIGN LOAD 06 WHERE NECESSARY, FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 VERTICAL TO 2 <br />SHALL BE LIMITED TO V180 OF THE SPAN. HORIZONTAL. <br />03 ALL SHOP DRAWINGS, ERECTION DRAWINGS AND CALCULATIONS SHALL BEAR THE SEAL AND SIGNATURE OF A 07 WHERE ROCK OUTCROPPINGS ARE ENCOUNTERED IN A BUILDING FOUNDATION BEARING ON SOIL, SUCH <br />PROFESSIONAL ENGINEER LICENSED IN THE STATE OF THIS PROJECT. OUTCROPPING OR INTERFERENCE SHALL BE REMOVED TO A DEPTH 12 INCHES BELOW BOTTOM OF FOOTING <br />AND REPLACED WITH CLEAN GRANULAR MATERIAL CONTAINING LESS THAN 5% SILT, COMPACTED TO 95% <br />04 LATERAL BRACING OF WEB MEMBERS SHALL INCLUDE A DIAGONAL BRACE (2" THICK NOMINAL) AT SPACING DENSITY PER MODIFIED PROCTOR METHOD. MAINTAIN A MINIMUM COVER OF 1'-6" TO BOTTOM OF CONCRETE. <br />NOT TO EXCEED 20 FEET. ALL END BAYS SHALL BE DIAGONALLY BRACED. <br />08 WHERE SOLID UNFRACTURED ROCK IS ENCOUNTERED FOR A WALL LENGTH OF AT LEAST 25 FEET, WALLS MAY <br />05 BOTTOM CHORDS OF WOOD TRI'SSES SHALL BE CONTINUALLY BRACED AT A SPACING NOT TO EXCEED 10 BE POURED WITHOUT FOOTINGS BY TRENCHING 6 INCHES INTO THE ROCK AND PINNING THE WALL TO ROCK <br />FEET, LOCATED AT OR NEAR A PANEL POINT. DIAGONAL BRIDGING SHALL BE INSTALLED AT END BAYS AND IN WITH #6 x 3-0" LONG DOWELS AT 2'-8" ON CENTER, GROUTED INTO ROCK, EXTENDING V-6" INTO ROCK. NO <br />INTERMEDIATE BAYS AT 20 FEET SPACING. FROST PROVISIONS ARE REQUIRED FOR THIS DETAIL. PROVIDE CONTROL JOINT IN WALL AT ANY TRANSITION <br />BETWEEN ROCK BEARING AND SOIL BEARING CONDITIONS. <br />06 THE TRUSS ERECTOR IS RESPONSIBLE FOR PROPER TRUSS HANDLING AND FOR TEMPORARY BRACING. <br />ERECTION BRACING SHALL BE APPLIED AS EACH TRUSS IS PLACED IN POSITION. CARE MUST BE TAKEN TO 09 EXCAVATIONS SHALL BE DEWATERED TO A DEPTH OF AT LEAST 2 TO 3 FEET BELOW THE BOTTOM OF THE <br />STABILIZE THE FIRST TRUSS AND DIAGONAL BRACING IS NECESSARY TO AVOID PROGRESSIVE COLLAPSE. EXCAVATIONS TO ALLOW INSTALLATION OF FOOTINGS IN DRY ATMOSPHERE. <br />10 DIFFERENTIAL BACKFILL AGAINST FOUNDATION WALLS SHALL NOT EXCEED FOUR FEET UNTIL TOP BRACING <br />OR FRAMEWORK HAS BEEN IN PLACE FOR A MINIMUM OF THREE DAYS. CANTILEVERED RETAINING WALLS MAY <br />BE BACK -FILLED WITHIN 14 DAYS OF CONCRETE PLACEMENT, BUT IN NO CASE SHALL DIFFERENTIAL OF <br />BACKFILL, BETWEEN OPPOSITE SIDES OF THE WALL, EXCEED THE FINAL DESIGN DIFFERENTIAL. <br />11 ALL BOTTOM OF FOOTING ELEVATIONS ARE SUBJECT TO CHANGE UPON INSPECTION OF SOIL CONDITION. <br />ELEVATION OF ADJACENT FOOTINGS SHALL VARY ON A SLOPE NOT STEEPER THAN ONE VERTICAL TO TWO <br />HORIZONTAL. <br />12 THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE BOTTOM OF FOOTING ELEVATION IS CHANGED AND <br />OBTAIN REVISED DESIGN OF THE FOUNDATION AND RETAINING WALLS AS REQUIRED. <br />13 A MINIMUM 6-MIL POLYETHYLENE VAPOR BARRIER BETWEEN THE BOTTOM OF THE FLOOR SLAB AND THE TOP <br />OF THE COMPACTED SUBGRADE SHALL BE INSTALLED. <br />E LUMBER <br />01 ALL NEW LUMBER SHALL BE VISUALLY GRADED LUMBER, SOUTHERN YELLOW PINE NO.2 OR BETTER WITH <br />MAXIMUM MOISTURE CONTENT OF 19% AND MINIMUM E=1,600,000 PSI IN ACCORDANCE WITH THE NATIONAL <br />DESIGN SPECIFICATION (NDS) FOR WOOD CONSTRUCTION. <br />02 ALL LUMBER SHALL BEAR VISIBLE GRADE STAMPING. <br />03 ALL JOISTS BEARING ON MASONRY SHALL BE FIRECUT WITH MINIMUM BEARING LENGTH OF FOUR INCHES, <br />04 EXCEPT AS UPGRADED ON PLANS OR DETAILS, ALL LUMBER SHALL BE NAILED IN ACCORDANCE WITH THE <br />NAILING SCHEDULE IN TABLE 2304.9.1 OF CHAPTER 23 OF THE 2007 FBC. <br />05 JOISTS SHALL BE FASTENED TO STEEL GIRDERS BY EITHER OF TWO ACCEPTABLE METHODS AS FOLLOWS <br />EXCEPT AS NOTED AT'TIMBER CONNECTIONS' BELOW: <br />!) A CONTINUOUS 2 x 6 NAILER PLATE SHALL BE BOLTED TO THE TOP FLANGE OF STEEL WITH 1/2 DIA, <br />STAINLESS STEEL BOLTS AT 4'-0" ON CENTER, ON ALTERNATE SIDES OF WEB. JOIST SHALL BE TOENAILED <br />TO PLATE WITH 3 8d NAILS PER JOIST. JOISTS FRAMING FROM OPPOSITE SIDES SHALL LAP AT LEAST SIX <br />INCHES, AND BE SPIKED TOGETHER AND BLOCKED. <br />II) A CONTINUOUS 2 x 4 NAILER PLATE SHALL BE BOLTED ABOVE THE BOTTOM FLANGE OF STEEL MEMBER <br />WITH 1/2 INCH DIAM. BOLTS AT 4'-0" ON CENTER. JOISTS SHALL BE NOTCHED ON TOP TO PROVIDE <br />CLEARANCE OF TOP FLANGE AND TO PROVIDE A SPACE OF AT LEAST 3/4" BETWEEN STEEL AND SUBFLOOR. <br />MAXIMUM DEPTH OF NOTCH SHALL BE 1/4 THE DEPTH OF JOIST. 20 GAGE METAL TIE OR WOOD SCAB SHALL <br />BE USED TO FASTEN OPPOSITE JOISTS TO ON ANOTHER. <br />01 <br />CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY <br />FLORIDA BUILDING CODE - BUILDING 2007 W/ APPLICABLE SUPPLEMENTS <br />ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO <br />FLORIDA FIRE PREVENTION CODE 2007 EDITION <br />PROCEEDING WITH THE WORK. <br />02 <br />DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION <br />® ACCESSIBILITY <br />OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS REGARDING EXACT <br />REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND <br />IN ADDITION TO CODES LISTED ABOVE, ACCESS TO AND THROUGH THIS AMENITY IS <br />CLASSIFICATIONS. <br />DESIGNED TO CONFORM TO THE FAIR HOUSING ACT OF 1988 AND AMENDMENTS AND <br />FLORIDA ACCESSIBILITY CODE. <br />03 <br />ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK <br />ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A REVIEW <br />® SUMMARY <br />OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. <br />BUILDING TYPE NO. OF BLDGS. A/C AREA NON A/C AREA TOTAL AREA <br />SHADE STRUCTURE 2 587 SF 587 SF <br />04 <br />DO NOT SCALE DRAWINGS. USE ONLY PRINTED DIMENSIONS. <br />® CODE COMPLIANCE <br />05 <br />THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING <br />TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO <br />OCCUPANCY TYPE U UTILITY <br />PROCEEDING WITH THE PROJECT. <br />CONSTRUCTION TYPE V-B <br />AREA & HEIGHT LIMITATION (FBC-B TABLE 503): REQUIRED/ALLOWED PROPOSED <br />06 <br />THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS AND <br />MEAN HEIGHT 40' 12'-6" <br />PROGRAMS, AND FOR COORDINATING ALL PORTIONS OF THE WORK. <br />MAXIMUM NUMBER OF FLOORS 1 STORY 1 STORY <br />MAXIMUM AREA 5,500 SF 587 SF <br />07 <br />ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT THE <br />NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE NUMBERS <br />FIRE PROTECTION (FBC-B TABLES 601 & 6021 <br />SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY THE OWNER. <br />INTERIOR BEARING WALLS 0 HR 0 HR <br />08 <br />DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, OR <br />INTERIOR NON -BEARING WALLS 0 HR 0 HR <br />ROUGH OPENING AT STUD WALLS. <br />COLUMNS 0 HR 0 HR <br />BEAMS, GIRDERS & TRUSSES 0 HR 0 HR <br />09 <br />THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND DATA <br />FLOOR/CEILING ASSEMBLY 0 HR 0 HR <br />TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY PRODUCT <br />ROOF/CEILING ASSEMBLY 0 HR 0 HR <br />SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT ORIGINALLY <br />EXTERIOR BEARING WALLS 0 HR 0 HR <br />SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE NEW PRODUCT <br />EXTERIOR NON -BEARING WALLS 0 HR 0 HR <br />DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED PRODUCT <br />APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT. <br />0 <br />GENERAL - SITE WORK <br />01 <br />SOIL BEARING VALUES. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR <br />ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS <br />AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE <br />SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE <br />WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT <br />FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR <br />REVISED DESIGNS. <br />02 <br />THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE <br />UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED <br />AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL, <br />STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY <br />COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL <br />CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY. <br />03 <br />REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES, <br />FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC. <br />04 <br />REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL <br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES, <br />ETC. <br />05 <br />CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL <br />NOT BE LESS THAN 6 INCHES, (U.N.O.) <br />06 <br />NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT <br />PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE <br />SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. <br />E <br />GENERAL - STRUCTURAL <br />01 <br />THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL <br />CHAPTERS OF THE 2007 FLORIDA BUILDING CODE (FBC). ALL WORK SHALL BE PERFORMED IN ACCORDANCE <br />WITH THIS CODE AND ALL LOCAL REQUIREMENTS. <br />02 <br />DESIGN LOADS: <br />A. SEE DESIGN CRITERIA ON STRUCTURAL DRAWING. <br />B. FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS. <br />C. WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />D. COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />03 <br />ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING <br />DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE STRUCTURAL <br />ENGINEER PRIOR TO CONSTRUCTION OF WORK. <br />04 <br />THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND VERIFY <br />ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION, NOTIFY THE <br />ARCHITECT / ENGINEER OF ANY DISCREPANCIES. <br />05 <br />IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY <br />CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE <br />MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT / ENGINEER. <br />FORUME <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />1 fax: 407.830.4143 <br />i <br />AA0002731 <br />i www.forumarchitecture.com <br />i <br />Meetinghouse <br />at Zephyrhills <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />\. <br />N <br />O <br />Wcc <br />Q <br />1 <br />d <br />11/10/10 Bid & <br />Set 1 <br />_I <br />T DISTRIBUTIONS: <br />SHEET REVISIONS: <br />JT <br />i PROJECT NO. 09-2587 <br />z <br />Shuffleboard Court & <br />W <br />Shade Structure <br />General Notes <br />& Code Compliance <br />° <br />W <br />F_ <br />0 <br />A19.71 <br />I <br />0 <br />LL <br />