My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38422-38646 Valley Oaks
Zephyrhills
>
Building Department
>
Building Plans
>
38422-38646 Valley Oaks
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 3:36:29 PM
Creation date
2/18/2025 3:57:46 PM
Metadata
Fields
Template:
Building Plans
Street #
38422-38646
Location
Valley Oaks
Contractor
Adkins Electric
Building Plans - Permit #
11172-11175
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND/CATALOG NUMBERS <br />SMOKE DETECTOR, PHOTOELECTRIC TYPE <br />VISUAL INDICATING APPLIANCE <br />L�J <br />[�E <br />AUDIO/VISUAL INDICATING APPLIANCE <br />Ms <br />MINI SOUNDER <br />i <br />MINI SOUNDER WITH STROBE <br />❑E <br />MANUAL PULL STATION <br />FFA`C_P1 <br />ADDRESSIBLE FIRE ALARM CONTROL PANEL <br />AA <br />FIRE ALARM ANNUNCIATOR PANEL <br />F-M-M-1 <br />MONITOR MODULE <br />®M <br />CONTROL MODULE <br />S <br />MINI HORN/SMOKE DETECTOR (PHOTOELECTRIC) <br />FE-01-1 <br />END OF LINE RESISTOR <br />0 HEAT DETECTOR <br />a SPRINKLER SYSTEM FLOW SWITCH, NOT BY FIRE ALARM <br />CONTRACTOR <br />SPRINKLER SYSTEM VALVE TAMPER SWITCH, NOT BY <br />FIRE ALARM CONTRACTOR <br />L C <br />Please be advised ft review of plans submitted is a <br />Glremy review b assist the contractor in compliance with <br />applicable fie safety codes. This review is not intended <br />to be a final approval of the submitted plans. It is the <br />contractor's sole responsibility to ensure that the plans are in <br />complete compaance with all applicable NFPA codes and <br />local ordinmces. In the event that further examination or <br />site inspection reveals areas of non-compliance, it shall be <br />the contractor's sob responsibility, at their sole expense to <br />bring those areas in compliance. The City assumes no <br />responsibility for the contractor's failure to be in compliance <br />with all applicable WFPA Codes and local ordinances. <br />ILMMITfEI2 PIL.ANfS) 1tK' VE BEEN RFMEWEM <br />3Y ZEPHYRHI L FIR4MARS'S OFFICE <br />Date: <br />COMMUNITY BUILDING/BUILDING TYPE 1 <br />FIRE LITE 9200 <br />TO SHUNT TRIP - <br />CIRCUIT BREAKER <br />OF ELEVATOR <br />POWER CKT. <br />ELEVATOR <br />MACHINE B <br />ROOM <br />TOP OF ELEVATOR SHAFT <br />WARNING LIGHT ACTIVATION <br />BY MACHINE ROOM SMOKE <br />DETECTOR (TYPICAL) <br />ELEVATOR PIT <br />�Ibl <br />2ND. FLOOR <br />Tom/ <br />1 ST. FLOOR <br />._@WARNING LIGHT <br />�J"DO NOT USE ELEVATOR" <br />FIRE ALARM FLOOR ZONE <br />FIRE ALARM FLOOR ZONE <br />FIRE ALARM DETAIL FOR ELEVATOR <br />FULLY SPRINKLED BUILDING <br />NO SCALE <br />NOTES: <br />1. DERIVE POWER FOR FLASHING WARNING LIGHT FROM VISUAL ALARM CIRCUIT IN FIRE ALARM CONTROL PANEL. <br />2. COORDINATE HEAT DETECTOR LOCATIONS WITH SPRINKLERS. DETECTORS SHALL BE LOCATED WITHIN 24" OF EACH SPRINKLER HEAD. <br />3. INITIATION OF ELEVATOR LOBBY, TOP OF SHAFT, OR MACHINE ROOM SMOKE DETECTOR LOOP SHALL PLACE <br />ELEVATOR CONTROL INTO PHASE 1 RECALL MODE & RETURN ELEVATOR TO DESIGNATED SAFE PLACE. <br />LEGEND <br />3A SMOKE DETECTOR(S) AND 135 DEG F FIXED TEMPERATURE HEAT DETECTOR(S) LOCATED IN ELEVATOR MACHINE ROOM. <br />OB SHUNT TRIP CONTACT LOCATED IN HEAT DETECTOR TO SHUNT TRIP POWER TO ELEVATOR UPON ACTIVATION OF HEAT DETECTOR. <br />O SMOKE DETECTOR LOCATED IN ELEVATOR LOBBY. <br />3p FLASHING WARNING LIGHTS LOCATED ADJACENT TO ELEVATOR CALL BUTTON AT PRIMARY & ALTERNATE ACCESS LEVELS <br />EO SMOKE DETECTOR(S) AND 135 DEGREE F FIXED TEMPERATURE HEAT DETECTOR(S) LOCATED AT TOP OF SHAFT. SMOKE DETECTOR <br />SHALL NOT BE INSTALLED IN AN UNSPRINKLERED HOISTWAY UNLESS IT IS FOR ACTIVATION OF HOISTWAY SMOKE RELIEF EQUIPMENT. <br />FIRE LITE MS5 <br />BUILDING TYPE 3 � i I- I BUILDING TYPE 2 <br />FIRELITE MMF-300 <br />ADDRESSABLE MONITOR <br />MODULES TO MONITOR <br />ALARM, TROUBLE AND <br />SUPERVISORY CONTACTS <br />ON PANEL. (TYPICAL) <br />FIRELITE 1300 ISOLATOR <br />MODULE. (TYPICAL) <br />FIRE LITE MS5 <br />FIRE ALARM SYSTEM COMMUNICATIONS DIAGRAM <br />NO SCALE <br />FIRE ALARM CONTROL PANEL - COMMUNITY BUILDING/BLDG TYPE <br />DEVICE <br />QTY <br />STAND-BY CURRENT <br />AMPS <br />TOTAL STAND-BY <br />CURRENT AMPS <br />ALARM CURRENT <br />AMPS <br />TOTAL ALARM <br />CURRENT AMPS <br />FACP <br />1 <br />0.1000000 <br />0.10000 <br />0.460000C <br />0.460000 <br />REMOTE ANNUNCIATOR <br />1 <br />0.2700000 <br />0.27000 <br />0.270000C <br />0.270000 <br />MINI SOUNDER <br />MINI SOUNDER W STROBE <br />84 <br />0.0000000 <br />0.00000 <br />0.018000C <br />1.512000 <br />19 <br />0.000000C <br />0.0000C <br />0.177000C <br />3.363000 <br />SMOKE DETECTOR AND BASE <br />5 <br />0.010000C <br />0.000600C <br />0.000000 <br />0.0500C <br />0.055000C <br />0.008000C <br />0. 11 0000 <br />0.275000 <br />0.096000 <br />2.640000 <br />PULL STATION <br />12 <br />0.0072C <br />O.0000C <br />HORN STROBE <br />24 <br />MONITOR MODULE <br />2 <br />0.006000 <br />0.0120(.0.060000C <br />0.120000 <br />HEAT DETECTOR AND BASE <br />2 <br />0.002000q <br />0.0040q <br />0.0080000 <br />0.016000 <br />STROBE 15cd <br />2 <br />0.000000 <br />0.0000 <br />0.0550000 <br />0.110000 <br />TOTAL 0.44320 TOTAL 8.86200 <br />BATTERY CALCULATIONS <br />Required Standby Time <br />Non -Alarm Load Am s 0.44 A x 24 Hours = I 10.64 AH <br />Required Alarm Time <br />5 Minutes <br />Alarm Load (Amps) 8.86 A x 0.084 = 0.74 AH <br />Standby and Alarm Load Subtota 11.38 AH <br />Derating Factor x 1.2 <br />Total Ampere Hours Requirec 13.66 AH <br />FIRE ALARM CONTROL PANEL - BLDG TYPE 2 <br />DEVICE <br />QTY <br />STAND-BY CURRENT <br />AMPS <br />TOTAL STAND-BY <br />CURRENT AMPS <br />ALARM CURRENT <br />AMPS <br />TOTAL ALARM <br />CURRENT AMPS <br />FACP <br />MINI SOUNDER <br />1 <br />0.100000C <br />0.000000C <br />0.10000 <br />0.00000 <br />0.460000C <br />0.460000 _ <br />2.052000 <br />114 <br />0.018000C <br />MINI SOUNDER W STROBE <br />5 <br />O.000000C <br />0.00000 <br />0.177000C <br />0.885000 <br />SMOKE DETECTOR AND BASE <br />5 <br />0.010000C <br />0.0500C <br />0.055000C <br />0.275000 <br />PULL STATION <br />10 <br />0.000600C <br />0.0060C <br />0.008000C <br />0.080000 <br />HORN STROBE <br />MONITOR MODULE <br />HEAT DETECTOR AND BASE <br />12 <br />0.000000C <br />0.0000C <br />0.110000C <br />1.320000 <br />2 <br />0.006000C <br />0.01 20C <br />0.060000C <br />0.120000 <br />2 <br />0.002000q <br />000400 <br />0.00800oq <br />0.016000 <br />TOTAL 0.17200 <br />TOTAL <br />5.20800 <br />BATTERY CALCULATIONS <br />Non -Alarm Load (Amps) r 0.17 A x <br />Alarm Load (Amps) I 5.21 A x <br />Required Standby Time <br />24 Hours_ _ <br />Required Alarm Time <br />5 Minutes - <br />0.084 = <br />Standby and Alarm Load Subti <br />Derating Fa( <br />Total Ampere Hours Requ <br />4.13 AH <br />0.44 AH <br />4.57 AH <br />x 1.2 <br />5.48 AH <br />FIRE ALARM CONTROL PANEL - BLDG TYPE 3 <br />DEVICE QTY STAND-BY CURRENT TOTAL STAND-BY ALARM CURRENT TOTAL ALARM <br />AMPS CURRENT AMPS AMPS CURRENT AMPS <br />FACP <br />1 <br />0.1000000 <br />0.10000 <br />0.4600000 <br />0.460000 <br />MINI SOUNDER <br />88 <br />0.0000000 <br />0.0000 <br />0.0180000 <br />1.584000 <br />MINI SOUNDER W STROBE <br />8 <br />0.0000000 <br />0.0000 <br />- <br />0.1770000 <br />1.416000 <br />SMOKE DETECTOR AND BASE <br />5 <br />0.010000 <br />0.0500 <br />0.055000C <br />0.275000 <br />PULL STATION <br />10 <br />0.000600 <br />0.0060 <br />0.008000C <br />0.080000 <br />HORN STROBE <br />12 <br />0.000000 <br />_ <br />0.0000 <br />0. 11 0000 <br />1.320000 <br />MONITOR MODULE <br />2 <br />0.006000 <br />0.0120C.0.060000 <br />0.120000 <br />HEAL DETECTOR AND BASE <br />2 <br />0.002000 <br />0.0040 <br />0.008000 <br />0.016000 <br />IOIAL 0.1/200 IOIAL 5.2/100 <br />BATTERY CALCULATIONS <br />Required Standby Time <br />T 4.13 AH <br />Non -Alarm Load (Amps) 0.17 A <br />x 24 Hours <br />Required Alarm Time <br />5 Minutes <br />Alarm Load (Amps) 5.27 A <br />x 0.084 <br />= <br />0.44 AH <br />Standby and Alarm Load Subtota <br />4.57 AH <br />Derating Factor <br />x 1.2 <br />Total Ampere Hours Requirec <br />5.48 AH <br />BUILDING TYPE 3 <br />I FIRE LITE MS5 <br />4,('Vrn <br />(Veir� r4-f1 <br />M',W fi��2�Le <br />S✓ <br />LZ Ud i/� "Oa <br />�bU Ua[ 4- <br />3�� �� valbe Oak <br />38S ] b �&"f-y "I'_' <br />� fM43 � ll1772 1// <br />'40 �"' cb;' i�o <br />0 Mrot.0 fZ�12 <br />David Hunter &Associates, Inc. <br />12291 Sumter Square Drive West <br />Jacksonville, Florida 32218 <br />Tel: 904.662.2445 <br />Fax: 904.751.1205 <br />EB #00009882 DHA Number: D010021 <br />0 <br />O <br />LL_ <br />J <br />W z <br />LU <br />N <br />ILL <br />0 <br />c <br />0 <br />.y <br />G� <br />m <br />Cn <br />rn <br />a� <br />a <br />0 <br />0 <br />.y <br />CD <br />Cr. <br />h <br />Cn <br />Li <br />Drawn By <br />D. H. <br />Checked By <br />E. Y. <br />Job Number <br />D010021 <br />FIRE ALARM <br />LEGEND <br />RISER <br />AND <br />CALCULATIONS <br />FA-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.