Laserfiche WebLink
CONCRETE MASONRY UNITS E FOUNDATION & GENERAL CODES <br />01 FOUNDATIONS HAVE BEEN DESIGNED TO AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF. SHOULD <br />CONDITIONS VARY FROM THE ASSUMED, THE ARCHITECT SHALL BE NOTIFIED BEFORE CONTINUATION OF <br />WORK. <br />01. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL APPLICABLE CODES AND MUST NOTIFY <br />ARCHITECT OF DISCREPANCIES INDICATED BY THESE DOCUMENTS FOUND DURING BIDDING AND PRIOR TO <br />PROCEEDING WITH THE WORK. <br />FLORIDA BUILDING CODE - BULIDING 2007 W/ APPLICABLE SUPPLEMENTS <br />FLORIDA FIRE PREVENTION CODE 2007 EDITION <br />FORUME <br />01. ALL CONCRETE MASONRY UNITS SHALL BE HOLLOW LOAD BEARING UNITS CONFORMING TO ASTM C90, GRADE <br />N, TYPE I, WITH MINIMUM COMPRESSIVE STRENGTH OF UNITS =1,900 PSI ON NET AREA, WITH ASSUMED <br />DESIGN COMPRESSIVE STRENGTH, F'M =1,500 PSI. UNITS MAY BE FABRICATED EITHER WITH NORMAL WEIGHT <br />AGGREGATE (C33) OR WITH LIGHTWEIGHT AGGREGATE (C331). <br />02. ALL UNITS SHALL BE PLACED IN RUNNING BOND. <br />03. MORTAR SHALL BE TYPE M OR S. MIX 1 PART PORTLAND CEMENT,1/4 TO 1/2 PART HYDRATED LIME AND 2-1/4 <br />TO 3 PARTS SAND, MIXED ON SITE. <br />04. STORE ALL UNITS OFF GROUND TO PREVENT CONTAMINATION, COVER MATERIALS TO PROTECT FROM THE <br />ELEMENTS. <br />05. NO AIR -ENTRAINING ADMIXTURES OR ANTIFREEZE COMPOUNDS, SUCH AS CALCIUM CHLORIDE SHALL BE <br />ADDED TO MORTAR. <br />06. ALL WALLS OR PILASTERS SUPPORTING STEEL AT BEARING PLATES SHALL BE GROUTED SOLID FOR FOUR <br />COURSES IN DEPTH FOR A WIDTH OF 32". <br />07. DO NOT BACKFILL AGAINST FOUNDATION WALLS UNTIL MORTAR HAS ATTAINED MAXIMUM STRENGTH. WHERE <br />BACKFILL IS PLACED AGAINST FOUNDATION WALLS BEFORE FLOOR CONSTRUCTION IS IN PLACE, PROVIDE <br />TEMPORARY BRACING. <br />08. THE FIRST BLOCK COURSE ON FOOTING SHALL BE FILLED SOLID WITH CONCRETE, UNLESS NOTED OTHERWISE <br />IN DRAWINGS. <br />09. VERTICAL CONTROL JOINTS SHALL BE PLACED SUCH THAT THE RATIO OF JOINT SPACING (L) DIVIDED BY WALL <br />HEIGHT (H) DOES NOT EXCEED 3.0. IN NO CASE SHALL SPACING EXCEED 50 FEET. CONTROL JOINTS SHALL BE <br />CONSTRUCTED USING SASH BLOCKS AND DUR-O-WALL PREFORMED REGULAR RAPID CONTROL JOINT (OR <br />EQUAL OF EXTRUDED RUBBER). WALL REINFORCING SHALL BE DISCONTINUOUS AT JOINTS. VERTICAL JOINTS <br />SHALL BE LOCATED AS FOLLOWS: <br />A. CHANGES IN WALL HEIGHT. <br />B. AT CONSTRUCTION JOINTS IN FOUNDATION, IN ROOF AND IN FLOORS. <br />C. AT CHASES AND RECESSES FOR PIPING, COLUMNS, FIXTURES, ETC. <br />D. AT ABUTMENT OF WALL AND COLUMNS. <br />E. AT RETURN ANGLES IN'L','T' AND'U' SHAPED STRUCTURES. <br />F. AT ONE OR BOTH SIDES OF WALL OPENING. <br />10. CMU WALLS SHALL BE REINFORCED WITH TRUSS TYPE REINFORCING OF 9 GAGE ASTM A82 WIRE, GALVANIZED <br />, AT 16" ON CENTER (VERTICALLY), AND AT THE FIRST AND SECOND BED JOINTS ABOVE AND BELOW WALL <br />OPENINGS. <br />11. ALL MASONRY WALLS SHALL BE ADEQUATELY BRACED DURING CONSTRUCTION TO RESIST WIND LOADS OF 25 <br />PSF. NOTE THAT FLOOR AND ROOF DIAPHRAGMS WILL PROVIDE ULTIMATE STABILITY FOR WALLS. UNTIL <br />THESE ARE IN PLACE, MASONRY WALLS SHALL NOT BE BUILT HIGHER THAN 10 TIMES THEIR THICKNESS <br />WITHOUT BRACING. <br />a� <br />U <br />U) <br />a <br />u; <br />0 <br />o) <br />0 <br />0 <br />N <br />a <br />0 <br />0 <br />a <br />3 <br />o� <br />02 ALL FOOTINGS SHALL BE PLACED DIRECTLY ON VIRGIN SOIL, OR CERTIFIED COMPACTED FILL. <br />03 CONCRETE FOR FOUNDATIONS: <br />A 28 DAY COMPRESSIVE STRENGTH FOR CONCRETE SHALL BE AS FOLLOWS: <br />FOOTINGS 3000 PSI <br />SLAB ON GRADE 3000 PSI <br />WALLS 3500 PSI <br />B MAXIMUM CONCRETE SLUMP SHALL BE 4". <br />C SLAB ON GRADE SHALL BE 5" THICK WITH WWF 6 x 6 -W1.4 x W1.4. SLAB SHALL BE FINISHED IN <br />ACCORDANCE WITH ACI STANDARD 302 FOR CLASS 2 FLOORS. IN LIEU OF WWF, SLAB ON GRADE MAY <br />CONSIST OF FIBER REINFORCED CONCRETE ACI 544.2R-89. <br />D ALL CONCRETE SHALL BE MIXED, TRANSPORTED AND PLACED IN ACCORDANCE WITH ACI STANDARDS <br />318, 304 AND 301. <br />E ALL REINFORCING BARS SHALL BE OF BILLET STEEL CONFORMING TO ASTM A615, GRADE 60. <br />F ALL WELDED WIRE MESH SHALL CONFORM TO ASTM A185. <br />G ALL VERTICAL SURFACES OF CONCRETE SHALL BE FORMED FOR WALLS AND FOOTINGS. <br />H REINFORCING STEEL SHALL BE PLACED TO PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER: <br />SLAB ON GRADE 1-1/2" <br />WALLS 2" <br />FOOTINGS 3" <br />1 GRADE BEAMS SHALL BE FORMED ON SIDES. <br />04 ALL FILL SHALL BE PLACED IN 8 INCH LOOSE LIFTS (MAXIMUM) COMPACTED WITH VIBRATORY ROLLERS. FILL <br />MATERIAL SHALL BE TESTED BY MODIFIED PROCTOR DENSITY METHOD (ASTM D1557) AND MUST QUALIFY AS <br />SELECT, WITH LESS THAN 10% PASSING THROUGH THE NO, 200 SIEVE. SOIL SHALL BE PLACED WITH MOISTURE <br />CONTENT AND ENERGY TO PROVIDE 98% OF MAXIMUM DRY DENSITY BELOW SLABS ON GRADE, AND SOIL <br />SHALL BE COMPACTED TO 98% 12" AND 24" BELOW STRIP FOOTINGS AND COLUMN FOOTINGS, RESPECTIVELY. <br />IN PLACE DENSITY TESTS SHALL BE TAKEN FOR EACH 2,000 S.F. IN EACH LIFT. FOR ACCEPTANCE OF SOIL, <br />AVERAGE OF DENSITY TESTS MUST EXCEED THE SPECIFIED COMPACTION. NO TESTS SHALL BE PERMITTED <br />TO FALL BELOW 90% COMPACTION. <br />05 ALL EXTERIOR FOOTINGS SHALL BE PLACED A MINIMUM OF 2'-0" BELOW FINAL GRADE WHEN BEARING ON SOIL, <br />UNLESS NOTED OTHERWISE ON THE FOUNDATION DRAWINGS. <br />06 WHERE NECESSARY, FOOTING STEPS SHALL BE CONSTRUCTED AT MAXIMUM SLOPE OF 1 VERTICAL TO 2 <br />HORIZONTAL. <br />07 WHERE ROCK OUTCROPPINGS ARE ENCOUNTERED IN A BUILDING FOUNDATION BEARING ON SOIL, SUCH <br />OUTCROPPING OR INTERFERENCE SHALL BE REMOVED TO A DEPTH 12 INCHES BELOW BOTTOM OF FOOTING <br />AND REPLACED WITH CLEAN GRANULAR MATERIAL CONTAINING LESS THAN 5% SILT, COMPACTED TO 95% <br />DENSITY PER MODIFIED PROCTOR METHOD. MAINTAIN A MINIMUM COVER OF V-6" TO BOTTOM OF CONCRETE <br />08 WHERE SOLID UNFRACTURED ROCK IS ENCOUNTERED FOR A WALL LENGTH OF AT LEAST 25 FEET, WALLS MAY <br />BE POURED WITHOUT FOOTINGS BY TRENCHING 6 INCHES INTO THE ROCK AND PINNING THE WALL TO ROCK <br />WITH #6 x T-0" LONG DOWELS AT 2'-8" ON CENTER, GROUTED INTO ROCK, EXTENDING 1'-6" INTO ROCK. NO <br />FROST PROVISIONS ARE REQUIRED FOR THIS DETAIL. PROVIDE CONTROL JOINT IN WALL AT ANY TRANSITION <br />BETWEEN ROCK BEARING AND SOIL BEARING CONDITIONS. <br />09 EXCAVATIONS SHALL BE DEWATERED TO A DEPTH OF AT LEAST 2 TO 3 FEET BELOW THE BOTTOM OF THE <br />EXCAVATIONS TO ALLOW INSTALLATION OF FOOTINGS IN DRY ATMOSPHERE. <br />10 DIFFERENTIAL BACKFILL AGAINST FOUNDATION WALLS SHALL NOT EXCEED FOUR FEET UNTIL TOP BRACING <br />OR FRAMEWORK HAS BEEN IN PLACE FOR A MINIMUM OF THREE DAYS. CANTILEVERED RETAINING WALLS MAY <br />BE BACK -FILLED WITHIN 14 DAYS OF CONCRETE PLACEMENT, BUT IN NO CASE SHALL DIFFERENTIAL OF <br />BACKFILL, BETWEEN OPPOSITE SIDES OF THE WALL, EXCEED THE FINAL DESIGN DIFFERENTIAL. <br />11 ALL BOTTOM OF FOOTING ELEVATIONS ARE SUBJECT TO CHANGE UPON INSPECTION OF SOIL CONDITION. <br />ELEVATION OF ADJACENT FOOTINGS SHALL VARY ON A SLOPE NOT STEEPER THAN ONE VERTICAL TO TWO <br />HORIZONTAL. <br />12 THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHERE BOTTOM OF FOOTING ELEVATION IS CHANGED AND <br />OBTAIN REVISED DESIGN OF THE FOUNDATION AND RETAINING WALLS AS REQUIRED. <br />13 A MINIMUM 6-MIL POLYETHYLENE VAPOR BARRIER BETWEEN THE BOTTOM OF THE FLOOR SLAB AND THE TOP <br />OF THE COMPACTED SUBGRADE SHALL BE INSTALLED. <br />LUMBER <br />01. ALL NEW LUMBER SHALL BE VISUALLY GRADED LUMBER, SOUTHERN YELLOW PINE NO.2 OR BETTER WITH <br />MINIMUM E=1,600,000 PSI IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION 2005 (NDS) FOR WOOD <br />CONSTRUCTION. <br />02. EXCEPT AS UPGRADED ON PLANS OR DETAILS, ALL LUMBER SHALL BE NAILED IN ACCORDANCE WITH THE <br />NAILING SCHEDULE IN TABLE 2304.9.1 OF CHAPTER 23 OF THE 2007 FBC. <br />02. DRAWINGS ARE DEVELOPED TO ILLUSTRATE SIZE, ASSEMBLY, RELATIONSHIP, QUANTITY, AND IDENTIFICATION <br />OF BUILDING COMPONENTS. DOCUMENTS WORK IN CONJUNCTION WITH SPECIFICATIONS REGARDING EXACT <br />REQUIREMENTS OF PRODUCTS, INSTALLATION QUALITY, STANDARD EXECUTION OF WORK, AND <br />CLASSIFICATIONS. <br />03. ALL TRADES MUST REVIEW ALL CONSTRUCTION DOCUMENTS AND ARE RESPONSIBLE FOR ALL WORK <br />ASSOCIATED WITH THEIR TRADES IN THESE DOCUMENTS. DO NOT BASE SCOPE OF WORK ONLY ON A REVIEW <br />OF THE SHEETS TYPICALLY ASSOCIATED WITH THE TRADE'S SCOPE OF WORK. <br />04, DO NOT SCALE DRAWINGS. USE ONLY WRITTEN DIMENSIONS. <br />05. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS, SHALL VERIFY EXISTING <br />TOPOGRAPHY AND GRADE ELEVATIONS, AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO <br />PROCEEDING WITH THE PROJECT. <br />06. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE CONTROL OVER CONSTRUCTION MEANS, <br />METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING ALL SAFETY PRECAUTIONS AND <br />PROGRAMS, AND FOR COORDINATING ALL PORTIONS OF THE WORK. <br />ACCESSIBILITY <br />IN ADDITION TO CODES LISTED ABOVE, ACCESS TO AND THROUGH THIS AMENITY IS <br />DESIGNED TO CONFORM TO THE FAIR HOUSING ACT OF 1988 AND AMENDMENTS AND <br />FLORIDA ACCESSIBILITY CODE. <br />IIIIIIIIIIIIIIISUMMARY <br />BUILDING TYPE NO. OF BLDGS. A/C AREA NON A/C AREA TOTAL AREA <br />POOL TRELLIS 1 128 SF 128 SF <br />CODE COMPLIANCE <br />OCCUPANCY TYPE U UTILITY <br />CONSTRUCTION TYPE V-B <br />AREA & HEIGHT LIMITATION (FBC-B TABLE 503): REQUIRED/ALLOWED PROPOSED <br />MEAN HEIGHT 40' 11'-8" <br />MAXIMUM NUMBER OF FLOORS 1 STORY 1 STORY <br />MAXIMUM AREA 5,500 SF 128 SF <br />07. ADDRESSES: APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR THE BUILDINGS SO THAT THE FIRE PROTECTION (FBC-B TABLES 601 & 602): <br />NUMBERS OR ADDRESS IS PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROADWAY. THE NUMBERS <br />SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE DETERMINED BY THE OWNER. INTERIOR BEARING WALLS <br />INTERIOR NON -BEARING WALLS <br />08. DIMENSIONS SHOWN ARE TO FACE OF CONCRETE MASONRY UNITS, FACE OF STUD, MASONRY OPENING, OR COLUMNS <br />ROUGH OPENING AT STUD WALLS. BEAMS, GIRDERS & TRUSSES <br />FLOOR/CEILING ASSEMBLY <br />09. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND SUBMITTING PRODUCT APPROVAL SHEETS AND DATA ROORCEILING ASSEMBLY <br />TO THE BUILDING DEPARTMENT IN THE FORM THE BUILDING DEPARTMENT REQUIRES FOR ANY PRODUCT EXTERIOR BEARING WALLS <br />SELECTION THAT IS CHANGED BY THE OWNER AND/OR THE CONTRACTOR FROM THE PRODUCT ORIGINALLY EXTERIOR NON -BEARING WALLS <br />SPECIFIED AND SUBMITTED BY THE ARCHITECT. THE CONTRACTOR MUST FIRST SUBMIT THE NEW PRODUCT <br />DATA TO THE ARCHITECT FOR REVIEW AND APPROVAL BEFORE SUBMITTING THE REQUIRED PRODUCT <br />APPROVAL SHEETS AND DATA TO THE BUILDING DEPARTMENT. <br />MSITE WORK <br />01. SOIL BEARING VALUES. FOUNDATION DESIGNS ARE BASED ON AN ESTIMATED SOIL BEARING VALUE OR <br />ACTUAL VALUE AS SPECIFIED BY A GEOTECHNICAL ENGINEER AND NOTED ON THE DRAWINGS. FOUNDATIONS <br />AND SLABS ARE DESIGNED TO UNIFORMLY BEAR ON WELL COMPACTED, WELL DRAINED NON -EXPANSIVE <br />SOILS. A CERTIFIED SOILS ENGINEER SHALL REVIEW FOUNDATION DESIGNS, BUILDING LOADS, AND COMPARE <br />WITH SUBSURFACE SOIL INVESTIGATION RECOMMENDATIONS. SHOULD ON -SITE OBSERVATIONS SHOW THAT <br />FOOTINGS SHOWN HERE ARE NOT SATISFACTORY, THE ARCHITECT SHALL BE CONTACTED IMMEDIATELY FOR <br />REVISED DESIGNS. <br />02. THE CONTRACTOR SHALL PROVIDE ALL OF THE FOLLOWING SITE REQUIRED ITEMS, BUT NOT LIMITED TO: SITE <br />UTILITIES, SLEEVES, CONDUIT, PULL BOXES, STRUCTURAL BASES, FOOTINGS, ETC. DESCRIBED OR REQUIRED <br />AS PART OF A COMPLETE SYSTEM ON CIVIL ENGINEERING, LANDSCAPE, SWIMMING POOL, ARCHITECTURAL, <br />STRUCTURAL, MECHANICAL, ELECTRICAL OR PLUMBING DRAWINGS. COORDINATE FULLY WITH ALL UTILITY <br />COMPANIES TO DETERMINE WHAT COMPONENTS ARE PROVIDED BY THE UTILITY COMPANIES. THE GENERAL <br />CONTRACTOR IS RESPONSIBLE FOR ALL ITEMS NOT SUPPLIED BY THE UTILITY COMPANY. <br />03. REFER TO CIVIL ENGINEERS SITE PLAN AND DETAILS FOR ACTUAL BUILDING LOCATIONS, FINISHED GRADES, <br />FLOOR ELEVATIONS, UTILITIES, DRAINAGE, ETC. <br />04. REFER TO LANDSCAPE ARCHITECT AND/OR POOL DESIGNER'S PLANS FOR LANDSCAPING, FENCES, POOL <br />DESIGN, IRRIGATION, EXTERIOR FURNISHINGS, TRAFFIC CONTROL, AND OTHER DECORATIVE LIGHT FIXTURES, <br />ETC. <br />05. CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL GRADE ON THE EXTERIOR OF BUILDING SHALL <br />NOT BE LESS THAN 6 INCHES, (U.N.O.) <br />06. NOTICE OF TERMITE PROTECTION. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT <br />PROVIDER AND NEED FOR REINSPECTION AND TREATMENT CONTRACT RENEWAL SHALL BE PROVIDED. THE <br />SIGN SHALL BE POSTED NEAR THE WATER HEATER OR ELECTRICAL PANEL. <br />0 GENERAL - STRUCTURAL <br />01. THESE STRUCTURAL PLANS HAVE BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL <br />CHAPTERS OF THE 2007 FLORIDA BUILDING CODE. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH <br />THIS CODE AND ALL LOCAL REQUIREMENTS. <br />02. DESIGN LOADS: <br />A. SEE DESIGN CRITERIA ON STRUCTURAL DRAWING. <br />B. FLOOR LIVE LOADS HAVE BEEN REDUCED IN ACCORDANCE WITH CODE FOR GIRDERS AND COLUMNS. <br />C. WIND LOAD: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />D. COMPONENTS AND CLADDING: SEE REQUIRED DESIGN WIND PRESSURES ON STRUCTURAL DRAWINGS. <br />03. ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING <br />DRAWINGS. CONFLICTS IN DIMENSION AND INTERFERENCE SHALL BE DIRECTED TO THE STRUCTURAL <br />ENGINEER PRIOR TO CONSTRUCTION OF WORK. <br />04. THE CONTRACTOR SHALL CHECK THE BUILDING LOCATIONS WITH REGARD TO PROPERTY LINE AND VERIFY <br />ALL EXISTING CONDITIONS PRIOR TO EXCAVATION AND SHOP DRAWING PREPARATION. NOTIFY THE <br />ARCHITECT 1 ENGINEER OF ANY DISCREPANCIES. <br />05. IN CASE OF CONTRADICTION BETWEEN THE DRAWINGS, THE SPECIFICATIONS AND THE CODES, OR IF ANY <br />CHANGE IS REQUIRED, THE CONTRACTOR SHALL INFORM THE ENGINEER IMMEDIATELY. NO CHANGE SHALL BE <br />MADE WITHOUT WRITTEN APPROVAL OF THE ARCHITECT / ENGINEER. <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />0 HR <br />10 <br />ARCHITECTURE & <br />INTERIOR DESIGN, INC. <br />PLANNING I ARCHITECTURE I INTERIOR DESIGN <br />745 orienta avenue, suite 1121 <br />altamonte springs, fl 32701 <br />phone: 407.830.1400 <br />fax: 407.830.4143 <br />AA0002731 <br />www.forumarchitecture.com <br />Meetinghouse <br />at Zephyrhills <br />Senior <br />Apartments <br />City of Zephyrhills, FL <br />U <br />M� <br />m� <br />ms <br />U� <br />w� <br />Q <br />0 <br />SAT DISTRIBUTIONS: <br />EDITED BY: JT <br />PROJECT NO. 09-2587 <br />Pool Trellis <br />General Notes & <br />Code Compliance <br />A19,51 <br />